Starts, stops and protects. Emotron TSA Softstarter

Similar documents
A softstarter beyond the ordinary

Your choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

We put all our energy into saving yours

Drainage control the easy way. Emotron DCM control unit

ABB Softstarter Benefits Charnchanok Thongprad

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

We put all our energy into saving yours

Softstarters from ABB. ABB Low Voltage Products. Controlling the elements

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Tough environments Smooth operations

Softstarters Softstarters

CTi Automation - Phone: Fax: Web:

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs


a revolution in soft start motor control The future of soft start motor control at your fingertips

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

Panorama. Softstarters The complete range

The PSE Softstarter Easy and Reliable with LCD display and torque control

The future of soft start motor control at your fingertips

HVW701 HVAC Drive with By-Pass

PSE The efficient range Description

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Application example of a motor controlled by MCD100 and protected by a circuit breaker

SX SERIES. Force & flow in harmony.»» IP54 compact size»»690 V power supply»»true application oriented inverter

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

High performance Vector Control. Ratings. System configuration

Softstarters. Catalogue. Type PSR. Catalogue 1SFC132003C0201 (1SFC132152F001)

Game changing soft starters

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

RVS-AX Instruction Manual

Features and Benefits. Control Features

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Variable speed drive or soft starter?

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

HVAC-R Drive Products

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

Catalog. Softstarters Type PSR, PSS, PSE, PST and PSTB

a revolution in soft start motor control The future of soft start motor control at your fingertips

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

ACS 1000, ACS 1000i. Medium voltage AC drives for control of induction motors from kw

Product brochure. Medium voltage AC drive ACS2000, kw, kv

CT430 - Soft Starters on Motor Applications

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

SSW07. Soft Starters. Applications. Standard Features

Distributed intelligence

ABB central inverters PVS to 1000 kw

ABB Softstarters The new PSS line from 3A to 515A

Unidrive M700 Class leading performance with onboard real-time Ethernet

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

Benefits. transmission devices (gearboxes, pulleys, gears, conveyers, etc) Soft-Star ters are static star ting switches, designed for the

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

Softstarters Type PSR, PSS, PSE, PST and PSTB

Frequency inverters overview

ABB drives for water and wastewater ACQ to 500 kw

BROCHURE. Low voltage AC drives ABB general purpose drives ACS580, 1 to 350 hp

Delta Products VFD CP2000 Bypass Control Packages.

Size for Size Best Value in the Industry

Technical Catalogue AC Drives

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SIRIUS Soft Starters Introduction

ABB central inverters PVS to 1000 kw

Powerdrive FX Ultra compact regenerative drive solution

RVS-DN Digital Reduced Voltage Motor Starter

DRIVE THE WATER CYCLE. January 10 TH 2013

RVS-DX Digital Reduced Voltage Motor Starter

MEDIUM VOLTAGE DRIVE STARTER TYPE MV-SVFD-ML1

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

ABB Drives ACS550-U1-059A-2, 20 HP, 3PH, 200 VAC, Wall Mount VFD

ROBICON W120 enclosed drive

Number 1 in efficiency

SOLSTART Instruction Manual

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Phone: Fax: Web:

pag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag.

Improves fan ef ciency

VASCO. Variable Speed Controller ENGLISH

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

TECHNICAL CATALOGUE AC DRIVES

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Softstarters Type PSTX30...PSTX370 User Manual short form 1SFC132082M9901

ABB central inverters PVS to 2000 kva

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Hydrovar and Packaged Hydrovar

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Drive IT ACS 1000i. Integrated Medium Voltage AC Drive

690+ Series Integrator

Transcription:

Starts, stops and protects Emotron TSA Softstarter

First in a new line of CG high performance softstarters Emotron TSA softstarters take motor control to a new level. Soft torque starting, intelligent load monitoring and smart stops are all included and accompanied by a robust and compact design. By developing the Emotron TSA range of electronic softstarters CG has taken a major step towards the ideal motor controller for applications where variable speed is not required. You simply get everything except variable speed! Robust and efficient Integrated by-pass with proven contactor technology To enable lowest possible energy consumption Emotron TSA softstarters are equipped with an integrated by-pass contactor. The Emotron TSA line hereby complements the well established fully solid-state softstarters Emotron MSF. The used types of by-pass contactors have been selected only after thorough evaluation of various contactor designs and how to best achieve a reliable and fault-tolerant design. The finally chosen solutions are able to handle repeated switching in harsh environment and fulfill the need for a safe and robust control. 3-phase torque control Most AC asynchronous or induction motors used in industry carry three electrical phases. Adjusting the motor torque is best done by controlling the current in all three phases. 3-phase control offers symmetrical and balanced currents without the drawbacks of additional energy losses, noise and vibration normally connected with 2-phase softstarters. Emotron TSA softstarters incorporate 3-phase control together with sophisticated algorithms for torque control. Conventional softstarters use a pre-defined voltage ramp to control the start. With Emotron TSA, the actual motor torque is continuously calculated and controlled according to the

application requirements. This torque control ensures an ultra-smooth start with constant acceleration. The torque control means the starting current is reduced even further by up to 30%. You can use smaller fuses and less expensive cables, and will thus benefit from lower installation and energy costs. The smooth starts also lead to less mechanical stress, improved process control and reduced maintenance costs. Controlled starts also with challenging loads Torque boost can be used to overcome initial torque peaks when starting, for example, a loaded crusher or mill. This will reduce mechanical stress as well as enhance efficiency in your process. Starting a fan which is rotating in the wrong direction due to a draught, will lead to high current peaks and mechanical stress and can result in blown fuses and breakdown. An Emotron TSA softstarter gradually slows the motor to a complete stop before starting it in the right direction. Damage is prevented and mechanical vibrations are eliminated. The starting direction can be fully controlled, for example of a tunnel fan if there is a fire when controlling the direction of the air flow is critical for safety reasons. Emotron TSA offers full control without the need for an external PLC, thanks to two inputs for start left/right and built-in control of forward/reverse contactors. You will benefit from simplified installation and reduced investment costs. Smart stops with built-in braking functionality The definition of a smart stop depends on your application. For a pump, the aim is to slowly decrease the flow to prevent mechanical stress on pipes and valves, while a saw often requires a quick stop for security or productivity reasons. The advanced braking techniques of Emotron TSA softstarters meets both challenges just as efficiently. When stopping a pump you can benefit from the same smart principle as when starting it a linear stop using the torque control. You no longer risk water hammer and there is no need for costly equipment such as motor-controlled valves. When a quick stop is needed, the brake functionality of Emotron TSA eliminates the need for expensive and space-consuming external brakes and saves you both investment and maintenance costs. The built-in vector brake is used for handling low braking torque loads. The built-in reverse current brake control efficiently handles high inertia loads in, for example, crusher or mill operation. It s also the solution for band saws and saw applications where extremely short braking times are required. 8 7 6 5 I/I N 4 3 2 1 2,000 1,000 Current 5 10 With an Emotron TSA the start current is up to 30% lower than with a conventional softstarter. Speed Emotron TSA with torque control Softstarter with voltage control Y/D start Direct on line (DOL) start 5 10 Emotron TSA offers efficient torque control that enables you to start more smoothly with constant acceleration. Speed DOL Y/D DOL start Y/D start Voltage/current control softstarter Voltage/current control softstarter Emotron TSA torque control softstarter Emotron TSA torquecontrol 5 10 15 The torque control ensures a linear stop that protects your pump from water hammer. No motor-controlled valves are required. Time 1,480 rpm Time Time

Slow speed and jog operation Apart from ramping up and down the speed between zero and rated motor speed, Emotron TSA softstarter offer low speed operation in both forward and reverse direction without additional hardware. Slow speed or jogging forward or backward can be useful for aligning a load or having the motor running at low speeds for test or service purposes. Examples of applications where such low speed or jog operation is valuable are loading/unloading of centrifuges or mixers or positioning of feeding conveyors. Coated boards When used in harsh environment the lifetime of electric equipment might be on risk due to exposure to airborne aggressive substances. To improve the ability of the softstarters to withstand tough conditions the Emotron TSA units have circuit boards with conformal coating according to IEC 61721-3-3, 3C3 as standard. Extended protection with thermal model To enable maximum utilization of your softstarter investment the Emotron TSA units are largely self-protecting against overload. A thermal model of the softstarter secures that maximum possible number of starts can be performed without failure or unnecessary shut-downs. Compact dimensions Emotron TSA softstarters are among the smallest in their class. Due to the space-efficient construction and somewhat unique by-pass design a compact, but yet user friendly design has been achieved.

Clever and Easy to use Easy to install and easy to use Installation is quick and cost-efficient, since no additional equipment is required. Everything you normally need is included in an Emotron TSA unit. A number of options let you customize the softstarter functionality. Multi-lingual control panel with single-function keys and copy function Designed for global application the Emotron TSA softstarters carry a multi-lingual display unit as standard. The control panel has a menu system with unique menu numbers and separate menu keys and start/stop keys.

Motor load monitoring with auto-set of alarm levels The Emotron TSA softstarter has a built-in load monitor that protects your machine and process against costly downtime, equipment damage and break-down. It reacts immediately if a crusher is jammed, a pump is running dry, a compressor is idling, or a fan is operating inefficiently due to a blocked filter. This is achieved by constant viewing of the motor shaft power. Any deviation from your selected load Load Overload stop Overload warning Normal load curve levels will result in a warning or a quick but smooth stop. The actual load can be remotely displayed via analogue or fieldbus communication output. The monitor can also be used to determine when a process is ready, for example, when the viscosity is right in a mixing process. You can rely on an efficient and reliable operation protected from damage and interruptions. Programmable logical and timer functions with Real Time Clock The Emotron TSA softstarter offers built-in programming blocks, such as logical functions, comparators and timers. This opens the way for customizing functionality according to your requirements. A Real Time Clock provides information about the actual date and time of the day. The real time information is used for time registration in the event log and to enable preprogrammed starting and stopping at certain date and time. Underload warning Underload stop Time Standard inputs/outputs include: 4 Digital in, 1AnaIog in, 3 Relay out, 2 Analog out and a motor PTC input. A built-in load monitor protects your process against damage and inefficiency by sending a warning or stopping the process at your chosen load levels.

Applications Pumps Fans Compressors Blowers Crushers Screens Mills Mixers Saws Options One communication module and up to two option boards can be mounted. Communication modules Profinet 1 or 2 ports - Industrial Ethernet communication Modbus/TCP Industrial Ethernet communication EtherCAT - Industrial Ethernet communication Profibus DP- Fieldbus communication DeviceNet - Fieldbus communication Serial communication via USB or RS485, (later also Bluetooth) with Modbus RTU. RS232 as standard. Option boards Extended digital I/O (3 + 3 sets I/O) PTC/PT-100 Motor protection (3 + 3 PT100) Other options External control panel, IP54 suitable for mounting on cabinet door Technical data Model Framesize P mot 400 V [kw] P mot 460 V [hp] I nom [A] Weight [kg] Dim. HxWxD [mm] All Emotron TSA models - size 1 to 4 EMOTRON TSA SOFTSTARTERS ARE AVAILABLE IN THE FOLLOWING RANGE: Supply voltages: 200 525 VAC, 3-phase 50/60 Hz 200 690 VAC, 3-phase 50/60 Hz Rated current: 16 1800 A Rated power: 5.5 1800 kw Control supply voltage: 100 240 V Ambient temperature: 0 55 C (40 C without derating) Protection class: IP20, NEMA Type 1 (Up to 800 A) IP00, NEMA Open type (1000 1800 A) Approvals: CE (UL, GOST R pending) TSA - 016 Normal duty (*) 7.5 10 16 5.5 TSA - 022 11 15 22 TSA - 030 1 15 20 30 TSA - 036 18.5 25 36 TSA - 042 22 30 42 TSA - 056 30 40 56 TSA - 070 37 50 70 5.7 TSA - 085 2 45 60 85 TSA - 100 55 75 100 TSA - 140 75 100 140 13 TSA - 170 3 90 125 170 TSA - 200 110 150 200 TSA - 240 132 200 240 19 TSA - 300 4 160 250 300 TSA - 360 200 300 360 TSA - 450 250 350 450 TSA - 560** 315 450 560 TSA - 630** 355 500 630 5 TSA - 710** 400 600 710 TSA - 820** 450 700 820 TSA - 1000** 560 800 1000 TSA - 1400** 6 800 1200 1400 TSA - 1800** 1000 1500 1800 Pending *Normal duty: Start curr = 3 x Inom, Start time = 15s for framesize 1 resp. 30s for framesizes 2-6, 10 starts/hour **Preliminary data 296x126x 188 323x196x 235 411x254x 260 Pending

CG Drives & Automation Mörsaregatan 12 Box 222 25 SE-250 24 Helsingborg Sweden T + 46 42 16 99 00 F +46 42 16 99 49 info.se@cgglobal.com www.cgglobal.com / www.emotron.com CG Drives & Automation 01-6026-01, 2014-04