OPERATING INSTRUCTIONS

Similar documents
PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL

Operating and Installation Instructions Pulsation Damper P Series for Pumps of the BIOCOR Series

SAUTER TVO Version /2014 GB

Introduction Designation system. 2. Operation in explosion-proof areas Technical data Performance curves... 4

Operating and Installation Instructions. ought to be studied before installing the pump. Introduction Operation in explosion proof areas...

Operation and Installation Instructions AH 20/32 S. Metal High-Pressure Diaphragm Pumps AH 20 S AH 32 S

Sandfiltration kit + Swimmey pump

Explosion-Protected Pressure Switches

MKT Series AUDIPACK. AUDIPACK Industriestraat GT Moerkapelle The Netherlands

User Manual. PBA428 Weighing platform

Operating Instructions

485 - NC NO/DA DN

Operating manual FP-2. Index

Operating Instructions

Crane fork KGM/KGA and KGQ/KGL

HD-X2. Operating Instructions. Ref. No H /1232

D 40 ALUMINIUM (CLAMPED)

BR 31a Rack-and-pinion Actuator,

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

INSTRUCTION MANUAL Air operated double diaphragm pumps Ver Models: DMF 10 DMF 20

Model DA05 Model DA07 Model DA10

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

D 25 POLYPROPYLENE (BOLTED)

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

PNEUMATICALLY ACTUATED 2-WAY

Beton Trowel nv INSTRUCTION MANUAL SLAB SAW BTCS500 - GEBABEBB BBRUBEBB BNP FORTIS: ING: BE BE

ADVANCED FLUID MANAGEMENT SOLUTIONS. Sturdy and reliable industrial and diaphragm pumps. 5 YEARS ANNI DI GARANZIA WARRANTY.

DulcoFlex Peristaltic Pump: DFB13B

ECD 16,8. Art.-No.: Operating Instructions Battery-powered Drill/Screwdriver with Adjustable Torque

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS AMP-22 MODEL

OPERATION MANUAL 1 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM

SAFETY MANUAL READ FIRST!

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

User manual / 230 V. Electronically controlled motor, constant torque with intermediate reverse

Spare part lists Futur

TriScroll TM 300 Series Dry Scroll Vacuum Pump

Operation & Service Manual

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

PNEUMATIC-DRIVEN PUMP Series 3414

N CX 5500 DAT Operating and Instruction manual

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

motor driven metering pumps

Dumper OPERATOR S MANUAL

OPERATION MANUAL 2 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

INDUSTRIAL DYEING PUMPS

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

AMC3/AMS3 OPERATING INSTRUCTIONS PULSATION DAMPER AMC3/AMS3 OPERATING INSTRUCTIONS

motor driven metering pumps

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

DulcoFlex Peristaltic Pump DFC 50

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

PE & PTFE Diaphragm Pumps

DIAPHRAGM LIQUID PUMP NF 1.30

HS-2/HS-3/HSR/DSD-500/DSD-600

motor driven metering pumps

OPERATION INSTRUCTION

INSTRUCTION MANUAL. Filter Press Pumps TF Cast Metal series. Aluminium Grey Iron Stainless Steel. Model No. Serial No

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

POTATO DIGGER WITH OSCILLATING SIEVES DM 100

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

DulcoFlex Peristaltic Pumps: DFB010 DFB013 DFB016 DFB019 DFB022

Solenoid valve VDHT standard BSP (British Standard Pipe)

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 %

VALFONTA USE, INSTALLATION AND MAINTENANCE MANUAL PNEUMATIC CONTROL VALVE MODEL C1

Analytical Diaphragm Pump Series MP MP06, MP12

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Product Engineering Guide

Dumper 1001, 1501, 2001 OPERATOR S MANUAL

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Air Powered Double Diaphragm Pumps. Polypropylene Pumps. Made In Japan

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Operating Instruction

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

Pressure switch hex 27

Betriebsanleitung Operating Instructions. Diaphragm Pump

Phantom 4 RTK. Quick Stark Guide V1.0

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

PE & PTFE Diaphragm Pumps

Metallic Air Operated Double Diaphragm Pumps. EU product Made in Italy

Gerotor pump, fixed displacement volume

A408 GB. Pneumatic oil and diesel pumps 1:1

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Pump Kits. More than just pumps

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

CPM-I-D60 Constant-Pressure Modulating Inlet Valve

Special Radial piston pumps Type SRK-ATEX

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

Solenoid Operator 0516 / 1216

Operating and maintenance instructions

ELADOS EMP IV E00 Diaphragm Pump type

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

DulcoFlex Peristaltic Pump DFDa70

Instruction Manual. Ex-Time 40 / 50

Transcription:

OPERATING INSTRUCTIONS CE Pulsation Dampeners PD 25-METALLIC PD 25-NON METALLIC NAUTIC Active Pulsation Dampeners.

Preparing instructions The NAUTIC active pulsation dampeners represent the latest generation of active pulsation dampeners. They are also specially designed to be used together with TULIP Air Operated Double Diaphragm pumps in the Non-Metallic versions. A general aspect to be considered is, that a pulsation dampener can decrease the total capacity of the system depending on the point of operation. Before putting a NAUTIC pulsation dampener into operation, make sure, that the materials of construction are resistant to the lquid to be pumped. To check this, the exact dampener code is required This code, as well as the serial number, can be found in the following key.be known that these data are noted on the identification plates on the damper itself. Model numberfication key. PD C 25 PE E P Material of dampener head: P - PE Diaphragm material E EPDM B Buna-N G Geolast TW Teflon Vulcanised Wetted material (in contact with the liquid) PE Polyethylene PT PTFE A Aluminium S Stainless Steel AISI 316 SH St.St.AISI 316-Hygienic Dampener nominal connection size:10: 3/8, 15: 1/2", 25: 1, 40: 1 1/2", 50: 2 Conductive version (ATEX) Pulsation Dampener. Air supply connection female: PD 10-15: R 1/8, PD 25-50: R 1/4" Max. operating pressure: 8 bar Max. operating temperature: for dampener housing in PE 70oC, for dampener housing in PTFE size PD 10: 100ºC, for the other sizes 120ºC (with dampener head in PE conductive 80ºC) Maximum viscosity liquid: 5.000 cps at 20ºC For inflammable liquids as well as for applications in explosion protected areas, only dampeners made of conductive polymer materials (code C) may be used. It is not necessary to ground the dampener separately, as the dampener is connected conductively to the pump, which is conductive and has be grounded itself. In general, pump and dampener are dispatched completely mounted. They can be packed in separate boxes, on customers wish. If so, the dampener has to be screwed into the thread at the top of non-metallic discharge port carefully, but only until the damper is in contact with the pump. Exceeded tightening may damage the thread. Besides, a correct positioning of the O-ring within the groove has to be ensured. Assembling instructions The Nautic dampener can easily be mounted to a pump at any time as near as possible to the discharge port. Page 01 Liquid Out Before connecting the pump, take the red blind plugs out

Air In of air inlet which is located on the top of the dampener head. For correct operation, the dampener absolutely needs an airsupply of itselves, which has to be taken from the air-supply of the pump. Pump and pulsation dampener have to be connected to the same air pressure. No stop or regulating valve may be placed between pump and dampener. The driving air has to be oilfree, dry and clean. Together with the pump an empty dampener has to be driven slowly. The dampers are self-regulating for all changing operating conditions. Liquid In The dampenercan be installed in all suitable poses without any influence of the dampening. Examples for installation. On pressure side of any pumpmodel.! CAUTION * Before putting the pulsation dampener into operation as well as after some hours of operating, the housing bolts [42] have to be tightened carefully, as the elements of construction tend to "settle". Fixing the bolts is necessary as well after longer periods of stoppage, at extreme temperature variations, transport and after dismantling. * Pressure tests of the plant a pump and a dampener are included it may only be carried out with the aggregate (pump and dampener) disconnected from the pressure on both ports or by using the pressure the aggregate develops while operating The load of a pressure in the plant may damage the pump and the pulsation dampener. * Before starting to disassemble the pump, take care that pump and dampener have been emptied and rinsed. Further both have to be cut off from any energy on the air and product side. If pump and dampener is being deported from the plant, a reference about the delivered liquid has to be attached * Please respect the relevant additional security advices, if the pump and the dampener have been used for aggressive dangerous or toxic liquids. * Before putting the pump and the dampener back into operation, the tightness of both has to be checked Disassembly instructions Unscrew housing bolts [42] carefully. After that, all parts can be removed. Screw the diaphragm [40] off the actuator shaft [39]. A re-assembly of used piston rings [37] is impossible; they have to be replaced including the O-rings underneath. To assemble new piston rings [37] carefully shape them like kidneys with locking ring pliers and insert the rings into the grooves; completely press the rings into the grooves smoothly using some round tool. 3D-Drawing Page 02

Spare part list, pulsation dampener serial PD 25. Page 03 Item Quantity Description Material Part Nr. 1 1 Liquid Chamber PE 100/PD185PE PE Conductive 100/PD185PEC PTFE 100/PD185PT PTFE Conductive 100/PD185PTC

Aluminium 100/PD185A St.Steel 100/PD185S 2 1 Air Chamber PE 100/PD186PE PE Conductive 100/PD186PEC 3 1 Diaphragm Elastomerlist 100/183xxx 4 1 Outer Diaphragmplate PP 100/181P PVDF 100/181K Aluminium 100/181A St.Steel 100/181S 5 1 Inner Diaphragmplate Steel 100/181C 6 1 Actuator Shaft 100/PD116 7 3 O-Ring Bearing Buna-N 100/E103A 8 1 Air Exhaust Muffler PE 100/PDM 9 1 Pin PE 100/PDP 10 8 Bolt M8 x 130 St.Steel 100/PD186B 11 8 Washer 8 St.Steel 100/PD186W 12 8 Nut with Flange M8 St.Steel 100/PD186N 13 1 Sealing O-Ring Elastomerlist 100190xxx 14 16 Dust Cover PE 100/PD186BC Pulsation Dampener 1 inch Dimensions Inches Metric mm. A 8,0 202 B 7,2 182 C 9,4 240 D 1" Male 1" Male E 1/4" Female 1/4" Female Pulsation Dampener assembly drawing PD 25 Page 04

Page 05 EC-DECLARATION OF CONFORMITY FOR MACHINERY directive, 94/9/EC ATEX). DECLARACIÓN CE DE CONFORMIDAD PARA LAS MAQUINAS (Directiva 98/37/EG, Anexo II, letra A) DÉCLARATION CE DE CONFORMITÉ POUR LES MACHINES (98/37/EG,Annexe II, point A) KONFORMITÄTSERKLÄRUNGEN FÜR MASCHINEN (EG-Richtlinie 98/37/EG, Anhang II, Buchstabe A) DICHIARAZIONE DI CONFORMITÀ CE PER LE MACCHINE (Direttiva 98/37/EG, Allegato II, Punto A) EG-VERKLARING VAN OVEREENSTEMMING VOO MACHINES (Richtlijnen 98/37/EG, Bijlage II, onder A) DECLARAÇAO CE DE CONFORMIDADE PARA AS MÁQUINAS (Directiva Máquinas 98/37/EG, Anexo II, Alínea A) PROHLÁŠENÍ EU O SHODĚ PRO STROJE ( směrnice 98/37/EG, příloha II, písmeno A)

PROHLÁŠENÍ EU O SHODĚ PRO STROJE ( směrnice 98/37/EG, příloha II, písmeno A) TULIP PUMPS B.V. Herewith declares that: declara que: déclare que: erklärt hiermit dass: dichiariamo che: Verklaart dat: declara que: prohlašuje, že: Air operated Diaphragm Pumps and Pulsation Dampeners Aire operada Diafragma Bombas Air Opéra Diaphragm Pompe Luft Getriebener Membran Pumpen und Pulsation Dämpers. Pomped Diaframma Azionate ad Aria Lucht Gedreven Membraan Pompen en Pulsatiedempers. Ar Operada Diafragma Bombas Vzduchová membránová čerpadla Models: TE53-M52-TE132-T240-T538-T985/Metalic Version M10-M25-M52-M55-M125-T200-T400/Non Metalic Version PD10-PD15-PD25-PD40-PD50-PD65 in Non Metalic and Metallic Version II 2 G Eex c IIB T 4 (For Zone I) Models: TEP53-TEP132-T240-T538-T985/Non Metalic Version PD10-PD15-PD25-PD40-PD50-PD65 in Non Metalic and Metallic Version II 3 G Eex c IIB T 4 (For Zone 2) are in compliance with the Machinery Directive (98/37/EG, and directive, 94/9/EC ATEX). Está en conformidad con la directiva para las maquinas (98/37/EG, con inclusión de 94/9/EC ATEX). Est en conformité avec la Directive pur les machines (98/37/EG /CEE, modifée par, 94/9/EC ATEX). Konform ist mit den einschlägigen Bestimmungen der EG-Maschinenrichtlinie (89/392/EWG, einschliesslich Änderungen, 94/9/EC ATEX). È in conformità alla Direttiva-CE Macchine (98/37/EG, incl. 94/9/EC ATEX). In overeenstemming is met de Machinerichtlijn 98/37/EG, waarin opgenomen, 94/9/EC ATEX). Está em conformidade com a Directiva Máquinas (98/37/EG, incl. De 94/9/EC ATEX). Jsou v souladu se směrnicí pro stroje (98/37/EG, s dodatky 94/9/EC ATEX). On Behalf of: Pieter Deurloo Ede, 10-08-2009 Managing Director TULIP PUMPS BV. Goorsteeg 120 6718 TB Ede. Holland. The final user of the mentioned product is responsible for classifying its area of use (zone) For Zone 1: Pumps made w ith casings and/or manifolds, centre sections & airvalve housings in conductive plastic and/or metal materials. For Zone 2: Pumps made w ith casings and/or manifolds, centre sections & airvalve housings in non-conductive plastic and/or metal materials. Zone 1-II 2 G:Surface equipment for using in areas w here gas, vapors or mists are occasionally present during normal operation.(en 1127-1 6.3 Zone 2-II 3 G:Surface equipment for using in areas w here the presence of gas, vapors or mists is unlikely, or rare and from short duration during operation. Eex c : Equipment w ith build-in safety features (EN 13463-5) Safety symbol in accordance w ith DIN 40012 Appendix A. T4 : Allow ed temperature class: Max.Liquid temp.: 65ºC. Max.Ambient temp.: 135ºC. II B : Page 06 Exclusion of follow ing halongenated solvents as: Hydrogen, Acetylene, Carbon disulphide, Methyl Chloride, Carbon Tetrachloride.