Switching Power Supply

Similar documents
Switching Power Supply

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Inductive Proximity Sensor

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

24-hour/Weekly Time Switch H2F

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Hinged Safety Door Switch

Model Number Structure

Inductive Proximity Sensor

Power Controller. (see note 1) 10 sec

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Model Number Structure

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Model Number Structure

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Switch Mode Power Supply S8VS

S8VK-S (30/60/120/240/480-W Models)

E2K-L. Liquid Level Sensor. Applications. Ordering Information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Safety-door Switch. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Model Number Structure

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Ordering Information. Text PCB Power Relay G5LE

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Model Number Structure

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Manual Reset Limit Switch

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

A22NK. Key-type Selector Switches

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Digital display Pressure range ON/OFF output Linear output Model

Model Number Structure

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Differential Pressure Sensor

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Analog Input Terminal

Transistor Remote Modules

Cylindrical Proximity Sensor

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

H3DS-X - Solid State Two-Wire Timer

PS5R-S. Switching Power Supplies

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Inductive Proximity Sensor

Ordering Information. Text Surface-Mounting Signal Relay G6K

Subminiature Basic Switch

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Small Limit Switch D4V

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Analog Output Terminal

Model Pressure range ON/OFF output Linear output

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Ordering Information. DC Backup Block for S8TS S8T-DCBU-01. DC Backup Block (See note 1.) Bus Line Connector. Basic Block. Battery Holder.

Tactile Switch (Hinged Type)

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

General Purpose Relay

G3PE-Single-phase. Solid State Relays for Heaters

Model Number Structure

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Mechanical Key Switch

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

LS200 Series Instruction Manual

Transcription:

Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels with 100 mm depth. Ordering Information Power ratings Output voltage Output current Model 3 W 5 V 0.6 A -7305 12 V 0.25 A -7312 15 V 0.2 A -7315 24 V 0.13 A -7324 7.5 W 5 V 1.5 A -7705 12 V 0.6 A -7712 15 V 0.5 A -7715 24 V 0.3 A -7724 ±12 V 0.3 A (+12 V)/0.2 A ( 12 V) -7727 ±15 V 0.2 A (+15V)/0.2A ( 15 V) -7728 Model Number Legend: - 1 2 3 1.Input Voltage 7: 12 to 24 VDC 2. Power Ratings 3: 3 W 7: 7.5 W 3. Output Voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 27: ±12 V 28: ±15 V 1

Specifications Ratings/Characteristics Efficiency (typical) Life expectancy Item Input Voltage 10.2 to 27.6 VDC DC input 3 W Single output 7.5 W 60% to 73% (Varies with specifications.) 8 yrs. min. (Used at 40 C at the rated input with a 50% load. Current (with rated I/O) 0.6 A max. 1.2 A max. Noise filter Yes Dual Output 7.5 W Output Voltage adjustment range ±5% ±5% Not possible (See note 1) Additional function Ripple Input variation influence 2% (p-p) max 0.5% max. (10.2 to 27.6 VDC input, 100% load) Load variation influence 1.5% max. 1.5% max. : 1.5% max. : 3% max. Temperature variation influence Overload protection 0.05%/ C max. 105% min. of rated load current (typical), drop type, automatic reset Other Ambient temperature Operating: See the derating curve in the Engineering Data section Storage: 25 C to 65 C Note: Ambient humidity Operating: 25% to 85% Storage: 20% to 90% Dielectric strength Insulation resistance 1,500 VAC, 50/60Hz for 1 min (between all inputs and outputs/gr terminal) 100 MΩ min. at 500 VDC (between all outputs and inputs/gr terminal) Vibration resistance Malfunction: 10 to 55 Hz, 0.375-mm single amplitude each in X, Y, and Z directions for 2 hours. Shock resistance Screw tightening torque 0.74 N m max. (See note 2) Output indicator Approved standards Weight Malfunction: 294 m/s 2, 3 times each in ±X, ±Y, and ±Z directions Yes (green) UL 508, CSA E.B.1402C 150 g max. 1. The settings for the output voltage must be within the following range: : ±1% of the rated value : ±5% of the rated value 2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 2

Engineering Data Derating Curve Load (%) (B) (A) Note: The derating curve depends on the mounting direction of the Power Supply (A) (B) Standard (vertical) Mounting Position Horizontal Mounting Position Ambient temperature ( C) Overload Protection The power supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcurrent. When the output current rises above a set value (105% of the rated output current), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Rated voltage output. It operates at 105% min. of the rated current of output when output is producing the rated output, but this condition varies depending on output status. output has an independent short-circuit protection feature. Inrush Current, Startup Time, Hold Time AC input voltage Input ON Input OFF Output voltage (V) AC input current Inrush current on input application 90% 96.5% Output voltage 100 ms (max.) startup time 20 ms (min.) hold time 0 50 100 Output current (%) Dual Output Models output is provided with an overload protection that protects the load and the power supply by detecting total load value of and 3

Operation Single Output Fuse (3 A) Noise filter Rectifier Drive overload protection circuit Detector Photocoupler Dual Outputs Fuse (3 A) Noise filter Rectifier 3-terminal REG Drive overload protection circuit Rectifier Detector Photocoupler 4

Dimensions Note: All units are in millimeters unless otherwise indicated. -73 (3 W) -77 (7.5 W) 37.5 9.8 65 4 Mounting Holes Mounting bracket (provided with the model) 75 61 35 Six, M3.5 Note: 4.6 (Sliding 7 max.) 7.3 (See note 1) L (see note 2) 27 M4 or 4.5 dia. 1. A distance of 7.3 mm is required between the model and the mounting surface when the mounting bracket provided with the model is used. 2. If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Installation Terminal Arrangement Single Output Models Dual Output Models 6 1 1 1-7724 4 4 5 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. Note: A fuse is inserted to side. 3. Ground Terminal: Connect a ground line to this terminal. 4. Output LED Indicator: Lights while a DC output is ON (for the Dual Output Models, this indicator is lit when the DC output is ON). 5. V.ADJ Adjuster: Adjusts the output voltage. 6. NC Terminals: Vacant terminals. 2 3 2 3 5

Precautions Mounting To improve and maintain the reliability of the power supply over a long period of time, adequate consideration must be given to heat radiation. The power supply is designed to radiate heat by means of natural air-flow. Therefore, mount the power supply so that air flow takes place around the power supply. Generating Output Voltage (±) An output of ± can be generated by using two power supplies as shown, because the power supply produces a floating output. Air When mounting two or more power supplies side-by-side, allow at least 10 mm spacing between them, as shown in the following diagram. Forced air-cooling is recommended. 10 mm min. When connecting the power supplies in series with an operation amplifier, connect diodes to the output terminals (as shown by the dotted lines in the figure). Contact your OMRON representative for details on connecting diodes. Serial or Parallel Operation No serial or parallel operation is available. The positive and negative output terminals of a Dual Output Model cannot be connected in series to operate. To mount the power supply on a track, hook portion (A) of the power supply to the track and press the power supply to fit in portion (B). To dismount, pull down portion (C) with a screwdriver and pull out the power supply. Input Terminals Do not connect the input line to the other terminals of the power supply or the power supply will be damaged. The input terminals of DC input models have polarity. If the input polarities are reversed, the power supply will be damaged. Minimum Output Current The minimum output current of the -7727 and -7728 is restricted by the output voltage and control method. Note: All the outputs of the -7727 and -7728 are controlled by the output. If the output current falls to 10% or less of the rated output, the output voltage may drop. Track stopper 30 mm min. 6

7

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M044-E1-3A OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189 Printed in Japan 0101-0.5C 8