Switching Power Supply

Similar documents
Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Switching Power Supply

Inductive Proximity Sensor

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Inductive Proximity Sensor

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Model Number Structure

LS200 Series Instruction Manual

Switch Mode Power Supply S8VS

Model Number Structure

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Power Controller. (see note 1) 10 sec

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Model Number Structure

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

S8VK-S (30/60/120/240/480-W Models)

Cylindrical Proximity Sensor

Model Number Structure

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Solid State Relays G3NA. Model Number Structure. Model Number Legend

24-hour/Weekly Time Switch H2F

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Hinged Safety Door Switch

Manual Reset Limit Switch

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2EZ-X2D1-N E2EZ-X2D2-N

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

H3DS-X - Solid State Two-Wire Timer

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

RWS50B RWS100B RWS150B RWS300B RWS600B

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Model Number Structure

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

PS6R 480W Switching Power Supply

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Analog Input Terminal

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

INDUSTRIAL POWER SUPPLIES SFL-SERIES

ZWD100PAF Series Instruction Manual

Subminiature Basic Switch

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

ZWD225PAF Series Instruction Manual

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Text PCB Power Relay G5LE

Model Number Structure

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

TDK-Lambda ZWS300BAF/A

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Safety-door Switch. Ordering Information

Power Supply Technical Information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

G3PE-Single-phase. Solid State Relays for Heaters

PS5R-S. Switching Power Supplies

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Technical Information Solid State Relays. Glossary. Solid State Relays

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Tactile Switch (Hinged Type)

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

Ordering Information. Text Surface-Mounting Signal Relay G6K

Analog Output Terminal

G3PE-Single-phase. Solid State Relays for Heaters

Transcription:

Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote sensing function incorporated (). Overcurrent and overvoltage protection functions protect the internal ry. is VDE, UL, and CSA approved. -P is VDE, UL and CSA approved. Parallel operation using more than one is possible (). Automatically selects either 0 to 1 VAC or 0 to 240 VAC (input voltages). Minimum -year service life and free-of-charge guarantee period for 3 years. Mounting bracket provided. Ideal for driving the motors of industrial machines, robots, optical equipment, and cash-exchanging machines (-P). 1

Ordering Information General industrial use Suitable for peak loads such as solenoids and motors (see page 4). Capacity 150 W 300 W Output voltage 24 VDC 1 W (240 W at peak point) 240 W (480 W at peak point) -1524-3024 -1224P -2424P 12 VDC -1512 _ Input voltage No. of outputs Power ratings Model Output (voltage/current) 12 V 24 V 0 to 1/0 to 240 VAC 1 150 W -1512 13.5 A --- (automatically selected) -1524 --- 7 A 300 W -3024 --- 14 A Model Number Legend: 1 W (240 W at peak point) 240 W (480 W at peak point) -1224P --- 5 A ( A at peak point) -2424P --- A ( A at peak point) - 1 2 3 1.Power Ratings 12: 1 W 15: 150 W 24: 240 W 30: 300 W 2. Output Voltage 12: 12 V 24: 24 V 3. Peak-load Corresponding P: Peak-load corresponding 2

Specifications Ratings/Characteristics Item -P 150 W 300 W 1 W (240W at peak point) Efficiency (typical) 75% to 80% (12 to 24 V) 83% to 85% Life expectancy yrs. min. (Used at 40 C at the rated input with a 50% load) Input Voltage (AC only) Switchable between 0 V (85 to 132 V) and 0 V (170 to 264 V) Frequency 47 to 0 Hz Current 0 V input 3.5 A max. 6.5 A max. 3.0 A max. (6.0 A at peak point) (with rated I/O) 0 V input 2.5 A max. 4 A max. 1.8 A max. (3.6 A at peak point) 240 W (480 W at peak point) 5.5 A max. (11 A at peak point) 3.3 A max. (6.6 A at peak point) Leakage current 0 V input 0.5 ma max. 1 ma max. 0.5 ma max. 0.5 ma max. (with rated I/O) 0 V input 1 ma max. 1 ma max. 1 ma max. 1 ma max. Inrush current 0 V input 25 A max. (with rated I/O) 0 V input 50 A max. Noise filter Output Voltage adjustment range ±% (adjustable with variable resistor (V.ADJ)) Additional function Ripple Input variation influence Load variation influence Temperature variation influence Rise time Yes 12 V: 240 mv (p-p) max. 24 V: 480 mv (p-p) max. 480 mv (p-p) max. 1% max. (85 to 132/170 to 264 VAC input, 0% load) 2% max. (rated input, 0% to 0% load) 0.08%/ C max. (0 C to 50 C, with rated input and output) 800 ms max. (output voltage rise to 90%, with rated input and output) Hold time ms min. Overload protection 5% min.()/2% min. (-P) of rated load current (typical), drop type, automatic reset Overvoltage protection 1% of rated output voltage (typical), shut-off type, reset by input reset Remote sensing Yes No Remote control Yes Other Ambient temperature Operating: See the derating curve in the Engineering Data section. Storage: C to 85 C Note: Ambient humidity Operating: 30% to 90% Storage: % to 95% Dielectric strength Insulation resistance Vibration resistance Shock resistance Output indicator Electromagnetic interference Approved standards 2 k VAC, 50/60 Hz for 1 min (between all inputs and outputs/housing) 500 VDC for 1 min (between all outputs and inputs/housing) 2.5 k VAC, 50/60 Hz for 1 min (between all inputs and outputs/housing) 0 MΩ min. at 500 VDC (between all outputs and inputs/housing) Malfunction: to 55 Hz, 0.75-mm double amplitude (approx. 4.5G) for 2 h each in X, Y, and Z directions Malfunction: 294 m/s 2 (30G), 3 times each in ±X, ±Y, and ±Z directions Yes (red) Conforms to FCC class A standards UL12, CSA E.B. 1402C, VDE0160, VDE0805, EN60950 (IEC950) Malfunction: 294 m/s 2 (30G), 3 times each in ±X, ±Y, and ±Z directions UL12, CSA E.B. 1402C, VDE0160, VDE0805, EN60950 (IEC950) Weight 1,650 g max. 2,850 g max. 1,800 g max. 3,250 g max. The input ry incorporates a surge absorber. Remove the short bar from the FG and ACG terminals before conducting a withstand voltage test or insulation resistance test. 3

Engineering Data Derating Curve 1 Load (%) 0 80 60 40 0 (1) 0 30 40 50 60 70 Ambient temperature ( C) (2) (4) (3) ÉÉÉÉÉ Note: A Standard (vertical) mounting position ÉÉÉÉÉÉ The derating curve depends on the mounting direction of the Power Supply. B Horizontal mounting position In the case of mounting method A. Natural air-cooling: (1) + (2) Forced air-cooling: (1) + (2) + (3) + (4) In the case of mounting method B. Natural air-cooling: (1) Forced air-cooling: (1) + (2) + (3) Inrush Current, Rise Time, Hold Time Input ON Input OFF AC input voltage Inrush current on input application AC input current 90% 95% Output voltage Rise time (800 ms max.) Hold time ( ms min.) Overload Protection The Power Supply is provided with an overload protection function that protects the load and the Power Supply from possible damage by overcurrent. When the output current rises above a set value (5% of the rated output current for, and 2% of the rated output current for -P), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. -P Output voltage (V) Rated voltage Output voltage (V) 0 50 0 Output current (%) 0 0 0 Load current (%) 4

Overvoltage Protection The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by overvoltage. When the output voltage rises above a set value (1% of the rated output voltage), the protection function is triggered, shutting off the output voltage. If this occurs, reset the by turning it off for seconds min. and then turning it on again. To reset the -P, turn off the -P for 60 seconds min. and then turn it on again. Note: Be sure to turn on the power supply after the cause of the overvoltage output is found and the problem is solved. Output voltage (V) Approx. % % Rated output voltage % Variable range Overvoltage operation 5

Operation Corresponding to Peak Load (-P) If the load current waveform of the -P is pulse-shaped, the rated capacity of the -P need not be as large as the peak load current. The -P corresponds to the peak load current twice as large as the rated capacity of the -P. This means that the -P is cost- and space-saving and an ideal power supply for peak loads such as motors and solenoids. Output current (%) 0 0 0 Time With a power supply corresponding to peak loads With a conventional power supply Peak-load Current (-P) A peak load current waveform must satisfy the following condition. I av I m = Load current (%) Ip Im a 0 (I p a) τ T τ T + a Time (s) I p : Peak current value (0% max.) [A] I av : Rated output current [A] I m : Mean load current [A] τ: Pulse width (5 s max.) of peak current [s] T: Cycle [s] a: Continuous load current [A] Note: If there is a current flow exceeding the peak current value, the overcurrent protection will work and output voltage will be lowered. If the mean load current continuously exceeds the rated output current, the output will be OFF. If this occurs, turn off the -P for 60 seconds min. and then turn it on again. Corresponding Waveform Examples Load current (%) 0 0 0 5 5 5 5 Time (s) Remote Sensing Function () This function corrects a voltage drop in the load wiring. When using the remote sensing function, remove the short bars from the remote sensing terminals as shown in the following diagram. Load Remote sensing connection (2-conductor shielded cable) Wire connecting to load Remove the short bars. + S S Note: 1. When the voltage drop in the load wiring is large, the overvoltage protection function might engage due to the increase in voltage to correct the voltage drop, so be sure to use high capacity wiring. 2. If the +S and +V or S and V terminals are left unconnected, the overvoltage protection function will engage and the output voltage will be cut off. Remote Control Function The remote control function makes it possible to turn on or off the output without turning the Power Supply on or off. Tr SW + RC RC Remove the short bar. Use the Tr with a V CE of V min. and I C of 5 ma min. The terminal voltage is 0.4 V max. when the output is turned on. 6

Block Diagram ACG FG AC(L) Input AC(N) Fuse (see note) Noise filter Inrush current protection 0/0 V Automatically selected Rectifier and smoothing Rectifier Smoothing Overvoltage detector Overload detector DC OUT Note: The fuse capacity must be 5 A at 150 W and 8 A at 300 W. Auxiliary power supply Driver Switch + S Remote sensing S Limiting Photocoupler + R.C. R.C. Remote control -P ACG FG AC(L) Input AC(N) Fuse (see note) Noise filter Inrush current protection 0/0 V Automatically selected Rectifier and smoothing Rectifier Smoothing Overvoltage detector Overload detector DC Output Note: The fuse capacity must be 8 A at 1 W and 15 A at 240 W. Driver Switch Auxiliary power supply Limiting Photocoupler + R.C. R.C. Remote control 7

Dimensions Note: All units are in millimeters unless otherwise indicated. -15 (150 W) -1224P (1 W) 74 Four, M4 mounting holes (6 mm deep on the opposite side) 230 160 50 1 80 M4 terminal screws Four, M4 mounting holes (6 mm deep) 7.5 Four, M3 mounting holes for the provided mounting bracket (3 mm deep including the opposite side) 35 25 max. 7.5 160 0 Four, M3 mounting holes for the provided mounting bracket (3 mm deep including the opposite side) -3024 (300 W) -2424P (240 W) 146 Four, M4 mounting holes (6 mm deep on the opposite side) 230 160 50 1 80 M4 terminal screws Four, M4 mounting holes (6 mm deep) 7.5 Four, M3 mounting holes for the provided mounting bracket (3 mm deep including the opposite side) 90 28 25 max. 7.5 160 0 Four, M3 mounting holes for the provided mounting bracket (3 mm deep including the opposite side) 8

Mounting Bracket Bottom-mounting 94 Four, M4 166 Four, M4 40 40 95 95 40 40 Side-mounting 40 95 40 40 95 40 140 140 230 Four, M4 230 Four, M4 Mounting Holes Note: Attach the mounting bracket to the Power Supply and secure it with two screws. Then mount the mounting bracket to the panel. Two, 3.2-dia. holes (for mounting the Power Supply) Two, 5-dia. mounting holes 60 40 15 9

Installation -15 (150 W) 4 3 5 1 6-3024 (300 W) 9 2 7 8 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 3. V.ADJ Adjuster: Adjusts the output voltage. 4. Output LED Indicator: Lights while a Direct Current output (+V, V) is ON. 5. Remote Sensing Terminals: Correct the voltage drop in the load lines. Shorted for normal operation. 6. Remote Control Terminals: Connected to an external device to enable remote control of the output while the input voltage is being applied. 7. ACG Terminal: The intermediate point of the input filter. Shorted to FG terminal for normal operation. 8. FG Terminal: Shorted to the housing, and connected to a ground line. 9. NC Terminals: Leave unconnected..short Bar 4 3 5 1 6 9 2 7 8-1224P (1 W) 4 3 1 5 9-2424P (240 W) 8 2 6 7 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 3. V.ADJ Adjuster: Adjusts the output voltage. 4. Output LED Indicator: Lights while a Direct Current output (+V, V) is ON. 5. Remote Control Terminals: Connected to an external device to enable remote control of the output while the input voltage is being applied. 6. ACG Terminal: The intermediate point of the input filter. Shorted to FG terminal for normal operation. 7. FG Terminal: Shorted to the housing, and connected to a ground line. 8. NC Terminals: Leave unconnected. 9. Short Bar 4 3 1 8 2 5 9 6 7

Precautions Mounting To improve and maintain the reliability of the Power Supply over a long period of time, adequate consideration must be given to heat radiation. The Power Supply is designed to radiate heat by means of natural air-flow. Therefore, mount the Power Supply so that air flow takes place around the Power Supply. When mounting the Power Supply, mounting it to a steel plate is recommended. When mounting two or more Power Supplies side-by-side, allow at least mm spacing between them, as shown in the following illustration. Forced air-cooling is recommended. mm min. Steel plate ÉÉÉÉÉÉÉÉÉÉ Air Generating Output Voltage (±) An output of ± can be generated by using two Power Supplies as shown, because the Power Supply produces a floating output. Input Load Input Load Series Operation The output of two Power Supplies can be combined in series to double the output voltage as shown below. Input Load Input Parallel Operation The Power Supplies can be combined in parallel to increase the output current. The -P Power Supplies cannot be combined in parallel. 11

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No.T001-E1-3 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-78/Fax: (81)75-344-7189 Printed in Japan 10-0.6C 12