Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Similar documents
Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Digital Inverter 4 series

High Wall Type ( 2 Series )

Vertical Air Handling Unit type

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

INVERTER DUCTED SYSTEMS

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

SERVICE MANUAL OUTDOOR UNIT. No. OB386

Technical Service Manual

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Split-Sky Air FAYP-B Wall Mounted Unit

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

MSP Duct S Specifications

Engineering Data Book

Outdoor Units R-410A ARX-GV1B

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct (V shape evaporator)

Service manual MIV V4+ Indoor units

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Engineering Data Book

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

SERVICE MANUAL OUTDOOR UNIT. No. OB387

Engineering Data Book

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Version Modification Date Remark

CHILLED WATER FAN-COIL UNITS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

Engineering Data Book

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Split-Sky Air RMX-JZ Super Multi Plus

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

AIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

Compact Four-way Cassette Type

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

DESIGN & TECHNICAL MANUAL

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Outdoor Units, 50Hz, R410A

DC Inverter 10.0 / 12.5 / 14.0 kw

R410A INDOOR UNIT 1. WALL MOUNTED TYPE : AS A07LCC AS A09LCC AS A12LCC AS A14LCC AS A18LCC D1D_AS007E/

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

AHN 064 to 304 EHN/CHN 064 to 304

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

CEILING CONCEALED LOSSNAY LGH-25RX3

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

Concealed Ducted Split Series R22

CEILING CONCEALED LOSSNAY LGH-80RX3

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

CEILING CONCEALED LOSSNAY LGH-50RX3

D M S 760 C01 A A 1 1

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

Four-way Cassette Type

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

VHIA High-Static Ducted Indoor Units - 60HZ

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

technical data air conditioning systems MXS-B Multi Application Split Sky Air

GENERAL ELECTRIC FAN COIL UNITS

14 EXPLODED DIAGRAM/PARTS LIST. SMMS-i OUTDOOR UNIT MMY-MAP0804HT8P, MMY-MAP1004HT8P, MMY-MAP1204HT8P

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

FFQN-C, FCRN-E, FFRN-C

Transcription:

E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E

Contents 1 Specifications.............................................................. 2 2 Dimension................................................................. Wiring Diagram............................................................. 4 4 Refrigerating Cycle Diagram.................................................. Sensible Capacity Table...................................................... 6 6 Part Load Performance...................................................... Sound Characteristics (NC Curve)............................................. 9 8 Fan Characteristics........................................................ 10 EN 1

1 Specifications 1-1. Indoor Unit (Concealed Duct High Static Pressure Type) Model Indoor unit RAV-SM2242DT-E RAV-SM2802DT-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Cooling capacity (min.-max.) (kw) 20.0 (9.8-22.4) 2.0 (9.8-2.0) Heating capacity (min.-max.) (kw) 22.4 (9.8-2.0) 2.0 (9.8-1.) Electrical characteristics Cooling Heating Indoor unit Outdoor unit Total Indoor unit Outdoor unit Total Power supply (V) 0Hz / 1ph / 220-240V Running current (A).2-4.81.2-4.81 Power consumption (kw) 1.12 1.12 Power factor (%) 9 9 Power supply (V) 0Hz / N~ / 80-41V Running current (A) 9.8-9.00 12.-11.29 Power consumption (kw) 6.08.6 Power factor (%) 94 94 Power consumption (kw).20 (.26-9.09) 8. (.6-12.6) EER 2.8 2.6 Energy efficiency class * D D Power supply (V) 0Hz / 1ph / 220-240V Running current (A).2-4.81.2-4.81 Power consumption (kw) 1.12 1.12 Power factor (%) 9 9 Power supply (V) 0Hz / N~ / 80-41V Running current (A) 8.68-.9 11.6-10.40 Power consumption (kw)..0 Power factor (%) 94 94 Power consumption (kw) 6.49 (2.-.4) 8.1 (2.-11.01) COP.4.1 Energy efficiency class * B C Indoor unit (A) 1.0 1.0 Maximum current Outdoor unit (A) 18.0 20.0 Appearance Main unit Zinc hot dipping steel plate Main unit Height (mm) 40 40 Outer dimension Width (mm) 180 180 Depth (mm) 120 120 Total weight Main unit (kg) 160 160 Heat exchanger Finned tube Fan Centrifugal fan Centrifugal fan Standard air flow at 1Pa/ (at Mid tap) (m/h) 600 4200 Fan unit Fan Speed 1 1 Motor (W) 0 0 External static pressure (H/M/L) (Pa) 196/1/68.6 196/1/68.6 Air filter None (Local procure) None (Local procure) Controller (Sold Separately) RBC-AMT2E, AS21E2 Sound pressure level H/M/L (db A) 4 Sound power level H/M/L (db A) 4 Connecting pipe Gas side (mm) 28.6 28.6 Liquid side (mm) 12. 12. Drain port (mm) 2 (VP2) 2 EN

2 Dimension RAV-SM2242DT-E, RAV-SM2802DT-E / RAV-SM2242DT-TR, RAV-SM2802DT-TR (Unit:mm) Space required for installation and serving Check port 600 200 or more 200 1000 or more Service space Service space Hole for hanging bolt (4-12 92) 20 20 20 20 1288 (Hanging bolt mounting pitch) 128 120 200 0 10 40 (Hanging bolt mounting pitch) 100 1260 180 * Refrigerant pipe connecting port (Gas side Brazed) 190 Refrigerant pipe connecting port * (Liquid side Ø12. Flared) Electric parts box Power supply/communication piping port (Ø26) (Under electric parts box) 6 Air discharge port 22 Screw hole for duct mounting (10-M6) Drain pipe connecting port (V2) 46 Taper screw for R1,2.4 pipes 6 1 624 698 4 406 29 190 20 20 20 20 Air suction port Screw hole for duct mounting (10-M6) * Diameter of pipe connecting port Diameter of connecting pipe Liquid side Gas side Liquid side Gas side Ø12. Ø22.2 Ø12. Ø28.6 The diameter of connecting gas side on the indoor unit is 22.2, and therefore please use the accessory joint for installation. <Installation Notice> 1. Be sure to set a check port at the right of air discharge port. 2. Set to slope the drain piping downward at 1/100 and be sure to set a drain trap on its way as shown below figure.. Please avoid the installation on the place where oil disperses or is shrouded by oil smoke, such as kitchen or mechanical factory. 4. Indoor unit does not have air filter its inside. So be sure to set an air filter (local arrangements) in the position maintained easily such as a suction grills. (If there is no air filter, dusts are blocked in the air heat exchanger and it may cause failure or water leak in air-conditioner.). Please hang the main unit horizontally. Attention Be sure to set the plug and to make it to be able to cleaning, because garbage in drain piping piles up easily in drain trap. Check panel Plug (Check and cleaning port) 0 100 or more or more EN

Wiring Diagram RAV-SM2242DT-E, RAV-SM2802DT-E / RAV-SM2242DT-TR, RAV-SM2802DT-TR (Option) 1 1 L1 2 2 L2 8 BLK Indoor Unit #20 #20 Earth FASTON FASTON Screw Outdoor Unit Earth Screw 4F1 spark killer L N Power Supply 80-41V N~0Hz 4F2 8 spark killer 8 BLK ACIN 6 1 CN09 (YEL) 1 1 CN06(BLK) F1 F2 F 1 1 2 #18 FASTON CN04(GRY) Fuse T.0A 20V T10A,20V T10A,20V T10A,20V FAN 9 9 1 CN08() 1 1 DP CN068 (BLU) RY004 1 2 1 12 4 1 2 4 RC A B A B CN011 2 4 () 1 2 4 CN040 1 2 (BLU) 1 2 6 LM CN0 1 1 (GRN) 1 2 CN0 CN066() CN041(BLU) CN00() CN04() () U U4 Option Remote Controller RY00 H M L UL BLK BLK RY006 RY00 ORN RY002 DP TCC-LINK Adapter TCC-LINK Adapter (Option) RY001 4F1 4F2 4F2 4 CN00 () FS 12 4 6 CN01 1246 () ORN TR TA 1 12 2 CN104 (YEL) 4 46 1 2 1 2 4 6 1 1 1 1 2 2 4 6 6 12 FAN OPTION DRIVE CN02 1 1 2 2 4 4 6 6 (YEL) Sub P.C.Board MCC-120 TCJ 1 2 1 2 CN102 () CN061(YEL) TC 12 1 2 CN101 (BLK) Control P.C. Board for Indoor Unit Power supply circuit MCC-140 CN02 () 6 4 CN060() 4F1 CN080 (GRN) 1 2 PNL CN0 1 () EXCT 2 CN00 1 FILTER () 2 ORN RC RC RC BLK GRY 49F Indoor Unit Earth Screw Fan motor inside wiring diagram Motor over heating protection switch YEL BLU ORN R(L) S(N) Indoor Fan Power Supply 220-240V~ 0Hz 1 CN100 1 () MCC-126 COLOR IDENTIFICATION : :TE YEL:YELLOW BLU:BLUE BLK:BLACK GRY:GRAY PNK:PINK ORN:ORANGE GRN:GREEN BRW:BROWN GRY 1 2 4 4P 1 2 4 () GRY FAN FM Terminal No. A F1 F2 F F4 YEL BLU ORN Fan motor wiring GRY 124 4P 1 2 4 (BLU) GRY FAN2 FM2 A F1 F2 F F4 YEL BLU ORN Static pressure Pa (mmag) GRY 1 2 4 4P 124 () GRY FAN1 FM1 A F1 F2 F F4 YEL BLU ORN Note F 1 YEL 69 () F 2 BLU 1 (14) Setting from factory F ORN 196 (20) Symbol Part Name Symbol Part Name FM1~ Fan Motor RY002 Drain Control Relay RC Running Capacitor RY001 Louver Control Relay TR Transformer DP Drain Pump Motor TA Indoor temp sensor F1~ Fuse for Fan Motor TC, TCJ Temp sensor 4F1, 4F2 Fan Motor Control Relay RY00~00 Fan Motor Control Relay 1. indicates the terminal block. Letter at inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring at site.. indicates the control P.C board. 4. When installing the drain pump connect the froat switch connector to CN00 connector.. A position is connected to terminal block when change to static pressure. Exchange the lead wire of arrow ( ) position after check the terminal number as figure and lead wire s color of fan motor. 4 EN

4 Refrigerating Cycle Diagram RAV-SM2242DT-E(TR), SM2802DT-E(TR) Distributor (Strainer incorporated) Indoor unit TCJ sensor TC sensor Air heat exchanger Refrigerant pipe at liquid side ØB Refrigerant pipe at gas side ØA To outdoor unit Heating Cooling To outdoor unit Dimension table Outer diameter of refrigerant pipe Indoor unit Gas side ØA Liquid side ØB SM224, SM280 type 28.6 12. EN

Sensible Capacity Table Duct High Static Pressure Type Sensible Heat Capacity : RAV-SM2242DT-E(TR) / RAV-SM2802DT-E(TR) unit size 2242 outdoor air temp. CDB 14.0CWB 20.0CDB 1.0CWB 21.CDB 16.0CWB 2.0CDB indoor air temp. 1.0CWB 24.CDB 18.0CWB 26.0CDB 19.0CWB 2.0CDB 20.0CWB 28.0CDB 22.0CWB 0.0CDB 24.0CWB 2.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10.0 20.8 16.1 21.9 1.0 2.0 1.8 2.8 18. 24.6 19.1 2.4 19. 26.1 20.2 2.6 21.4 28.9 22.4 12.0 20. 1.9 21. 16. 22.6 1. 2.4 18.2 24.2 18.8 24.9 19. 2.6 19.9 2.1 21.1 28.4 22.0 14.0 20.1 1.6 21.2 16.4 22.2 1.2 2.0 1.8 2.8 18. 24. 19.0 2.2 19. 26. 20. 2.9 21.6 16.0 19.8 1. 20.8 16.1 21.8 16.9 22.6 1. 2.4 18.1 24.1 18. 24.8 19.2 26.2 20. 2.4 21. 18.0 19.4 1.1 20.4 1.8 21.4 16.6 22.2 1.2 2.0 1.8 2.6 18. 24. 18.9 2. 20.0 26.9 20.9 20.0 19.1 14.8 20.1 1.6 21.1 16. 21.8 16.9 22. 1. 2.2 18.0 2.9 18. 2. 19.6 26.4 20. 21.0 18.9 14.6 19.9 1.4 20.9 16.2 21.6 16.8 22. 1. 2.0 1.8 2. 18. 2.0 19.4 26.2 20. 2.0 18. 14.4 19. 1.1 20. 1.9 21.2 16.4 21.9 1.0 22.6 1. 2.2 18.0 24.6 19.1 2. 19.9 2.0 18.2 14.1 19.1 14.8 20.1 1.6 20.8 16.1 21. 16. 22.1 1.2 22.8 1. 24.1 18. 2.2 19.6 2.0 1.8 1.8 18.8 14.6 19. 1. 20.4 1.8 21.1 16.4 21. 16.8 22. 1. 2. 18. 24. 19.2 29.0 1. 1.6 18.4 14. 19. 1.0 20.0 1. 20. 16.0 21. 16. 21.9 1.0 2.2 18.0 24.2 18.8 1.0 1.1 1. 18.0 14.0 18.9 14. 19.6 1.2 20. 1. 20.9 16.2 21. 16.6 22. 1.6 2.8 18.4.0 16.8 1.0 1. 1. 18. 14.4 19.2 14.9 19.8 1.4 20.4 1.8 21.0 16. 22. 1. 2. 18.0.0 16.4 12. 1. 1.4 18.1 14.1 18.8 14.6 19.4 1.1 20.0 1. 20.6 16.0 21.8 16.9 22.8 1..0 16.1 12. 16.9 1.1 1.8 1.8 18.4 14. 19.0 14. 19.6 1.2 20.1 1.6 21. 16. 22. 1. 9.0 1. 12.2 16. 12.8 1.4 1. 18.0 1.9 18.6 14.4 19.1 14.8 19. 1. 20.9 16.2 21.8 16.9 unit size 2802 outdoor air temp. CDB 14.0CWB 20.0CDB 1.0CWB 21.CDB 16.0CWB 2.0CDB indoor air temp. 1.0CWB 24.CDB 18.0CWB 26.0CDB 19.0CWB 2.0CDB 20.0CWB 28.0CDB 22.0CWB 0.0CDB 24.0CWB 2.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10.0 2.9 18.0 2.2 19.0 26.4 19.9 2.4 20.6 28. 21. 29.2 22.0 0.0 22.6 1.8 2.9.2 2.0 12.0 2. 1. 24.8 18. 26.0 19.6 26.9 20. 2.8 21.0 28. 21.6 29. 22.2 1.2 2. 2. 24.6 14.0 2.1 1.4 24. 18. 2.6 19. 26. 19.9 2.4 20.6 28.2 21.2 29.0 21.8 0. 2.1 2.1 24.2 16.0 22. 1.1 2.9 18.0 2.1 18.9 26.0 19.6 26.9 20. 2. 20.9 28. 21.4 0.1 22. 1. 2.8 18.0 22. 16.8 2. 1. 24. 18.6 2. 19.2 26.4 19.9 2.2 20. 28.0 21.1 29.6 22. 1.0 2. 20.0 21.9 16. 2.1 1.4 24.2 18.2 2.1 18.9 2.9 19. 26. 20.1 2. 20. 29.1 21.9 0.4 22.9 21.0 21. 16.4 22.9 1.2 24.0 18.1 24.8 18. 2. 19.4 26.4 19.9 2.2 20. 28.8 21. 0.1 22. 2.0 21. 16.1 22.4 16.9 2. 1. 24.4 18.4 2.2 19.0 26.0 19.6 26. 20.1 28. 21. 29.6 22. 2.0 20.9 1.8 22.0 16.6 2.1 1.4 2.9 18.0 24. 18.6 2. 19.2 26.2 19. 2. 20.9 29.0 21.9 2.0 20. 1. 21.6 16. 22.6 1.1 2. 1. 24. 18. 2.0 18.8 2. 19. 2.2 20. 28.4 21.4 29.0 20.1 1.1 21.2 1.9 22.2 16. 2.0 1. 2.8 1.9 24. 18.4 2.2 19.0 26. 20.1 2.9 21.0 1.0 19. 14.8 20. 1.6 21.8 16.4 22. 1.0 2. 1.6 24.0 18.1 24. 18.6 26.1 19. 2. 20.6.0 19. 14. 20. 1. 21. 16.1 22.1 16.6 22.8 1.2 2. 1. 24.2 18.2 2.6 19. 26.8 20.2.0 18.9 14.2 19.9 1.0 20.9 1. 21.6 16. 22. 16.8 2.0 1. 2. 1.8 2.1 18.9 26.2 19..0 18. 1.9 19. 14. 20.4 1.4 21.1 1.9 21.9 16. 22. 1.0 2.2 1.4 24. 18. 2.6 19. 9.0 18.1 1.6 19.0 14. 20.0 1.0 20. 1.6 21.4 16.1 22.0 16.6 22.6 1.1 24.0 18.1 2.1 18.9 TC: Total Capacity [kw] SHC: Sensible Heat Capacity [kw] 6 EN

6 Part Load Performance 6-1. Indoor unit: RAV-SM2244DT-E(TR) Outdoor unit: RAV-SM2244AT8-E Cooling Cooling Heating Power Power Capacity Capacity consumption consumption Q (W) Q (W) W (W) W (W) MINIMUM 9800 260 9800 20 RATING 20000 200 22400 6490 Outdoor temperature ( C) Heating 46 40 0 2 20 Outdoor temperature ( C) 1 10 2 0 10 1 20 *: Protection operation Load (%) 100 90 80 0 60 0 40 0 20 10 Q 1880 1880 14110 120 1080 8820 8640 8640 8640 8640 W 610 00 910 480 940 100 90 90 90 90 Q 18920 100 1140 1240 110 9460 920 920 920 920 W 0 620 40 400 640 2860 00 00 00 00 Q 20000 18000 16000 14000 12000 10000 9800 9800 9800 9800 W 200 609 082 4189 91 266 260 260 260 260 Q 21080 1890 16860 1460 1260 1040 100 100 100 100 W 660 640 410 880 140 240 020 020 020 020 Q 22140 1990 110 100 1280 1100 1080 1080 1080 1080 W 6160 200 40 90 2900 2280 290 290 290 290 Q 2220 20900 1880 1620 190 11610 1180 1180 1180 1180 W 60 40 990 290 2660 2090 260 260 260 260 Load (%) 100 90 80 0 60 0 40 0 20 10 Q 2010 2410 21610 18910 16210 110 11820 11820 11820 11820 W 160 6020 4980 4060 220 2480 280 280 280 280 Q 240 22080 19620 110 1420 12260 100 100 100 100 W 680 10 420 80 00 20 2690 2690 2690 2690 Q 22400 20160 1920 1680 1440 11200 9800 9800 9800 9800 W 6490 460 420 680 2920 220 20 20 20 20 Q 20900 18810 1620 1460 1240 1040 9140 9140 9140 9140 W 6290 290 480 0 280 2180 2490 2490 2490 2490 Q 180 1680 14980 1110 11240 960 8190 8190 8190 8190 W 980 00 410 90 2690 200 20 20 20 20 Q 1460 1160 1100 10240 880 10 6400 6400 6400 6400 W 20 440 00 010 290 1840 2100 2100 2100 2100 Q 1460 1160 1100 10240 880 10 6400 6400 6400 6400 W 20 440 00 010 290 1840 2100 2100 2100 2100 Q 10 1280 11000 960 820 6880 6020 6020 6020 6020 W 10 440 90 2920 220 190 2040 2040 2040 2040 Q 12600 1140 10080 8820 60 600 10 10 10 10 W 4940 4160 440 2800 2220 110 1960 1960 1960 1960 Q 10620 960 8490 40 60 10 460 460 460 460 W 4660 920 240 2640 2100 1610 1840 1840 1840 1840 Q 8690 820 690 6080 210 40 800 800 800 800 W 480 690 00 2480 190 120 10 10 10 10 EN

6-2. Indoor unit: RAV-SM2804DT-E(TR) Outdoor unit: RAV-SM2804AT8-E Cooling Cooling Heating Power Power Capacity Capacity consumption consumption Q (W) Q (W) W (W) W (W) MINIMUM 9800 60 9800 20 RATING 2000 80 2000 810 Outdoor temperature ( C) Heating 46 40 0 2 20 Outdoor temperature ( C) 1 10 2 0 10 1 20 *: Protection operation Load (%) 100 90 80 0 60 0 40 0 20 10 Q 16010 16010 16010 14200 1210 10140 8640 8640 8640 8640 W 610 610 610 200 4000 2980 910 910 910 910 Q 2160 1980 1410 120 100 10880 920 920 920 920 W 990 620 6100 4800 690 20 610 610 610 610 Q 2000 2000 18400 16100 1800 1100 9800 9800 9800 9800 W 80 09 682 440 440 264 60 60 60 60 Q 24240 21820 1990 1690 140 12120 100 100 100 100 W 8110 680 20 4140 190 280 110 110 110 110 Q 2460 22910 200 1820 1280 120 1080 1080 1080 1080 W 490 6080 4860 80 2940 2190 2880 2880 2880 2880 Q 2600 2400 2160 18690 16020 10 1180 1180 1180 1180 W 680 0 4460 10 200 2010 2640 2640 2640 2640 Load (%) 100 90 80 0 60 0 40 0 20 10 Q 260 2900 2600 2290 1940 16280 1020 11820 11820 11820 W 8990 60 6260 090 400 120 2460 280 280 280 Q 290 26610 260 2000 140 1480 1180 100 100 100 W 820 10 940 480 840 2960 20 2690 2690 2690 Q 2000 2400 21600 18900 16200 100 10800 9800 9800 9800 W 810 6860 680 4620 60 280 220 20 20 20 Q 2190 2260 2010 160 1110 12600 10080 9140 9140 9140 W 900 660 00 4480 60 240 2160 2490 2490 2490 Q 220 2010 18060 1800 140 11290 900 8190 8190 8190 W 10 620 240 4260 80 2610 2060 20 20 20 Q 160 180 14100 1240 1080 8820 00 6400 6400 6400 W 660 620 460 80 010 220 180 2100 2100 2100 Q 160 180 14100 1240 1080 8820 00 6400 6400 6400 W 660 620 460 80 010 220 180 2100 2100 2100 Q 1680 14920 1260 11600 990 8290 660 6020 6020 6020 W 640 40 410 60 2910 220 10 2040 2040 2040 Q 1180 160 1210 1060 9110 90 600 10 10 10 W 6200 220 420 20 290 210 100 1960 1960 1960 Q 12800 1120 10240 8960 680 6400 120 460 460 460 W 80 4920 4080 20 260 200 1600 1840 1840 1840 Q 10480 940 880 0 6290 240 4190 800 800 800 W 00 460 80 120 2480 1910 110 10 10 10 8 EN

Sound Characteristics (NC Curve) Model name Measuring location Sound pressure level (db) H Under from unit 1. m (JIS Standard) RAV-SM2242DT-E Supply static duct Suction static duct 4 1.6 m 1.0 m 1. m RAV-SM2442DT-E RAV-SM2242DT-E RAV-SM2442DT-E 90 90 Octave band sound pressure level (db) 80 0 60 0 40 0 20 NC-0 NC-60 NC-0 NC-40 NC-0 NC-20 Octave band sound pressure level (db) 80 0 60 0 40 0 20 NC-0 NC-60 NC-0 NC-40 NC-0 NC-20 10 6 12 20 00 1000 2000 4000 8000 10 6 12 20 00 1000 2000 4000 8000 Octave band frequency (Hz) Octave band frequency (Hz) EN 9

8 Fan Characteristics 8 RAV-SM2242DT-E Standard air volume : 600m /h. Current of fan motor (A) 6. 6. High static pressure tap (0Hz) Medium static pressure tap (0Hz) 4. 4 Low static pressure tap External static pressure (Pa) 00 20 200 10 100 High static pressure tap (0Hz) 0 Low static pressure tap (0Hz) 2880 000 200 400 600 800 4000 4200 420 Medium static pressure tap (0Hz) Lower limit of air volume Air volume (m /h) Upper limit of air volume 8. RAV-SM2802DT-E Standard air volume : 4200m /h 8 Current of fan motor (A). 6. 6. 4. Low static pressure tap High static pressure tap (0Hz) Medium static pressure tap (0Hz) 4 0 External static pressure (Pa) 00 20 200 10 100 High static pressure tap (0Hz) 0 Low static pressure tap (0Hz) 60 600 4000 4400 4800 040 Medium static pressure tap (0Hz) Lower limit of air volume Air volume (m /h) Upper limit of air volume 10 EN

2-1, TAKANAWA -CHOME, MINATO-KU, TOKYO, 108-004, JAPAN Copyright 2010 TOSHIBA CARRIER CORPORATION, ALL Rights Reserved.