Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Similar documents
Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Digital Inverter 4 series

High Wall Type ( 2 Series )

Vertical Air Handling Unit type

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

INVERTER DUCTED SYSTEMS

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

SERVICE MANUAL OUTDOOR UNIT. No. OB386

Technical Service Manual

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

MSP Duct S Specifications

Split-Sky Air FAYP-B Wall Mounted Unit

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Engineering Data Book

Outdoor Units R-410A ARX-GV1B

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct (V shape evaporator)

Service manual MIV V4+ Indoor units

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Engineering Data Book

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

SERVICE MANUAL OUTDOOR UNIT. No. OB387

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

Engineering Data Book

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Version Modification Date Remark

CHILLED WATER FAN-COIL UNITS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

Engineering Data Book

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Split-Sky Air RMX-JZ Super Multi Plus

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

AIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

Compact Four-way Cassette Type

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

DESIGN & TECHNICAL MANUAL

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

DC Inverter 10.0 / 12.5 / 14.0 kw

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Outdoor Units, 50Hz, R410A

R410A INDOOR UNIT 1. WALL MOUNTED TYPE : AS A07LCC AS A09LCC AS A12LCC AS A14LCC AS A18LCC D1D_AS007E/

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

AHN 064 to 304 EHN/CHN 064 to 304

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

CEILING CONCEALED LOSSNAY LGH-25RX3

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

Concealed Ducted Split Series R22

CEILING CONCEALED LOSSNAY LGH-80RX3

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

CEILING CONCEALED LOSSNAY LGH-50RX3

D M S 760 C01 A A 1 1

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Four-way Cassette Type

VHIA High-Static Ducted Indoor Units - 60HZ

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

technical data air conditioning systems MXS-B Multi Application Split Sky Air

14 EXPLODED DIAGRAM/PARTS LIST. SMMS-i OUTDOOR UNIT MMY-MAP0804HT8P, MMY-MAP1004HT8P, MMY-MAP1204HT8P

GENERAL ELECTRIC FAN COIL UNITS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Transcription:

E0--2 High Static Duct 8, 0HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E

Contents Specifications.............................................................. 2 2 Dimension................................................................. Wiring Diagram............................................................. 4 4 Refrigerating Cycle Diagram.................................................. Sensible Capacity Table...................................................... 6 6 Part Load Performance...................................................... Sound Characteristics (NC Curve)............................................. 9 8 Fan Characteristics........................................................ 0 9 Capacity Correction........................................................ EN

Specifications -. Indoor Unit (Concealed Duct High Static Pressure Type) Model Indoor unit RAV-SM2242DT-E RAV-SM2802DT-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E capacity (min.-max.) (kw) 20.0 (9.8-22.4) 2.0 (9.8-2.0) capacity (min.-max.) (kw) 22.4 (9.8-2.0) 2.0 (9.8-.) Power supply (V) 0Hz / ph / 220-240V Indoor unit Running current (A).2-4.8.2-4.8 Power consumption (kw).2.2 Power factor (%) 9 9 Power supply (V) 0Hz / N~ / 80-4V Running current (A) 9.8-9.00 2.-.29 Outdoor unit Power consumption (kw) 6.08.6 Power factor (%) 94 94 Power consumption (kw).20 (.26-9.09) 8. (.6-2.6) Total EER 2.8 2.6 Electrical characteristics Indoor unit Outdoor unit Energy efficiency class * D D Power supply (V) 0Hz / ph / 220-240V Running current (A).2-4.8.2-4.8 Power consumption (kw).2.2 Power factor (%) 9 9 Power supply (V) 0Hz / N~ / 80-4V Running current (A) 8.68-.9.6-0.40 Power consumption (kw)..0 Power factor (%) 94 94 Power consumption (kw) 6.49 (2.-.4) 8. (2.-.0) Total COP.4. Energy efficiency class * B C Maximum current Indoor unit (A).0.0 Outdoor unit (A) 8.0 20.0 Appearance Main unit Zinc hot dipping steel plate Main unit Height (mm) 40 40 Outer dimension Width (mm) 80 80 Depth (mm) 20 20 Total weight Main unit (kg) 60 60 Heat exchanger Finned tube Fan Centrifugal fan Centrifugal fan Standard air flow at Pa/ (at Mid tap) (m/h) 600 4200 Fan unit Fan Speed Motor (W) 0 0 External static pressure (H/M/L) (Pa) 96//68.6 96//68.6 Air filter None (Local procure) None (Local procure) Controller (Sold Separately) RBC-AMT2E, AS2E2 Sound pressure level H/M/L (db A) 4 Sound power level H/M/L (db A) 4 Gas side (mm) 28.6 28.6 Connecting pipe Liquid side (mm) 2. 2. Drain port (mm) 2 (VP2) 2 EN

2 Dimension RAV-SM2242DT-E, RAV-SM2802DT-E / RAV-SM2242DT-TR, RAV-SM2802DT-TR (Unit:mm) Space required for installation and serving Check port 600 200 or more 200 000 or more Service space Service space Hole for hanging bolt (4-2 92) 20 20 20 20 288 (Hanging bolt mounting pitch) 28 20 200 0 0 40 (Hanging bolt mounting pitch) 00 260 80 * Refrigerant pipe connecting port (Gas side Brazed) 90 Refrigerant pipe connecting port * (Liquid side Ø2. Flared) Electric parts box Power supply/communication piping port (Ø26) (Under electric parts box) 6 Air discharge port 22 Screw hole for duct mounting (0-M6) Drain pipe connecting port (V2) 46 Taper screw for R,2.4 pipes 6 624 698 4 406 29 90 20 20 20 20 Air suction port Screw hole for duct mounting (0-M6) * Diameter of pipe connecting port Diameter of connecting pipe Liquid side Gas side Liquid side Gas side Ø2. Ø22.2 Ø2. Ø28.6 The diameter of connecting gas side on the indoor unit is 22.2, and therefore please use the accessory joint for installation. <Installation Notice>. Be sure to set a check port at the right of air discharge port. 2. Set to slope the drain piping downward at /00 and be sure to set a drain trap on its way as shown below figure.. Please avoid the installation on the place where oil disperses or is shrouded by oil smoke, such as kitchen or mechanical factory. 4. Indoor unit does not have air filter its inside. So be sure to set an air filter (local arrangements) in the position maintained easily such as a suction grills. (If there is no air filter, dusts are blocked in the air heat exchanger and it may cause failure or water leak in air-conditioner.). Please hang the main unit horizontally. Attention Be sure to set the plug and to make it to be able to cleaning, because garbage in drain piping piles up easily in drain trap. Check panel Plug (Check and cleaning port) 0 00 or more or more EN

Wiring Diagram RAV-SM2242DT-E, RAV-SM2802DT-E / RAV-SM2242DT-TR, RAV-SM2802DT-TR (Option) L 2 2 L2 8 BLK Indoor Unit #20 #20 Earth FASTON FASTON Screw Outdoor Unit Earth Screw 4F spark killer L N Power Supply 80-4V N~0Hz 4F2 8 spark killer 8 BLK ACIN 6 CN09 (YEL) CN06(BLK) F F2 F 2 #8 FASTON CN04(GRY) Fuse T.0A 20V T0A,20V T0A,20V T0A,20V FAN 9 9 CN08() DP CN068 (BLU) RY004 2 2 4 2 4 RC A B CN0 2 4 () 2 4 CN040 2 (BLU) 2 6 4F 4F2 4F2 A B LM CN0 (GRN) 2 CN0 CN066() CN04(BLU) CN00() CN04() () U U4 Option Remote Controller RY00 H M L UL BLK BLK RY006 RY00 ORN RY002 DP TCC-LINK Adapter TCC-LINK Adapter (Option) RY00 4 CN00 () FS 2 4 6 CN0 2 4 6 () ORN TR TA 2 2 CN04 (YEL) TCJ 2 2 CN02 () CN06(YEL) 2 4 46 2 2 4 6 2 4 6 6 2 FAN OPTION DRIVE CN02 2 2 4 4 6 6 (YEL) Sub P.C.Board MCC-20 TC 2 2 CN0 (BLK) Control P.C. Board for Indoor Unit Power supply circuit MCC-40 CN02 () 6 4 CN060() 4F CN080 (GRN) 2 PNL CN0 () EXCT 2 CN00 FILTER () 2 ORN RC RC RC BLK GRY 49F Indoor Unit Earth Screw Fan motor inside wiring diagram Motor over heating protection switch YEL BLU ORN R(L) S(N) Indoor Fan Power Supply 220-240V~ 0Hz MCC-26 COLOR IDENTIFICATION : :TE YEL:YELLOW BLU:BLUE BLK:BLACK GRY:GRAY PNK:PINK ORN:ORANGE GRN:GREEN BRW:BROWN CN00 () GRY 2 4 4P 2 4 () GRY FAN FM Terminal No. A F F2 F F4 YEL BLU ORN Fan motor wiring GRY 24 2 4 GRY 4P (BLU) FAN2 FM2 A F F2 F F4 YEL BLU ORN Static pressure Pa (mmag) GRY 2 2 4 4P 4 () GRY FAN FM A F F2 F F4 YEL BLU ORN Note F YEL 69 () F 2 BLU (4) Setting from factory F ORN 96 (20) Symbol Part Name Symbol Part Name FM~ Fan Motor RY002 Drain Control Relay RC Running Capacitor RY00 Louver Control Relay TR Transformer DP Drain Pump Motor TA Indoor temp sensor F~ Fuse for Fan Motor TC, TCJ Temp sensor 4F, 4F2 Fan Motor Control Relay RY00~00 Fan Motor Control Relay. indicates the terminal block. Letter at inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring at site.. indicates the control P.C board. 4. When installing the drain pump connect the froat switch connector to CN00 connector.. A position is connected to terminal block when change to static pressure. Exchange the lead wire of arrow ( ) position after check the terminal number as figure and lead wire s color of fan motor. 4 EN

4 Refrigerating Cycle Diagram RAV-SM2242DT-E(TR), SM2802DT-E(TR) Distributor (Strainer incorporated) Indoor unit TCJ sensor TC sensor Air heat exchanger Refrigerant pipe at liquid side ØB Refrigerant pipe at gas side ØA To outdoor unit To outdoor unit Dimension table Outer diameter of refrigerant pipe Indoor unit Gas side ØA Liquid side ØB SM224, SM280 type 28.6 2. EN

Sensible Capacity Table Duct High Static Pressure Type Sensible Heat Capacity : RAV-SM2242DT-E(TR) / RAV-SM2802DT-E(TR) unit size 2242 outdoor air temp. CDB 4.0CWB 20.0CDB.0CWB 2.CDB 6.0CWB 2.0CDB indoor air temp..0cwb 24.CDB 8.0CWB 26.0CDB 9.0CWB 2.0CDB 20.0CWB 28.0CDB 22.0CWB 0.0CDB 24.0CWB 2.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 0.0 20.8 6. 2.9.0 2.0.8 2.8 8. 24.6 9. 2.4 9. 26. 20.2 2.6 2.4 28.9 22.4 2.0 20..9 2. 6. 22.6. 2.4 8.2 24.2 8.8 24.9 9. 2.6 9.9 2. 2. 28.4 22.0 4.0 20..6 2.2 6.4 22.2.2 2.0.8 2.8 8. 24. 9.0 2.2 9. 26. 20. 2.9 2.6 6.0 9.8. 20.8 6. 2.8 6.9 22.6. 2.4 8. 24. 8. 24.8 9.2 26.2 20. 2.4 2. 8.0 9.4. 20.4.8 2.4 6.6 22.2.2 2.0.8 2.6 8. 24. 8.9 2. 20.0 26.9 20.9 20.0 9. 4.8 20..6 2. 6. 2.8 6.9 22.. 2.2 8.0 2.9 8. 2. 9.6 26.4 20. 2.0 8.9 4.6 9.9.4 20.9 6.2 2.6 6.8 22.. 2.0.8 2. 8. 2.0 9.4 26.2 20. 2.0 8. 4.4 9.. 20..9 2.2 6.4 2.9.0 22.6. 2.2 8.0 24.6 9. 2. 9.9 2.0 8.2 4. 9. 4.8 20..6 20.8 6. 2. 6. 22..2 22.8. 24. 8. 2.2 9.6 2.0.8.8 8.8 4.6 9.. 20.4.8 2. 6.4 2. 6.8 22.. 2. 8. 24. 9.2 29.0..6 8.4 4. 9..0 20.0. 20. 6.0 2. 6. 2.9.0 2.2 8.0 24.2 8.8.0.. 8.0 4.0 8.9 4. 9.6.2 20.. 20.9 6.2 2. 6.6 22..6 2.8 8.4.0 6.8.0.. 8. 4.4 9.2 4.9 9.8.4 20.4.8 2.0 6. 22.. 2. 8.0.0 6.4 2...4 8. 4. 8.8 4.6 9.4. 20.0. 20.6 6.0 2.8 6.9 22.8..0 6. 2. 6.9..8.8 8.4 4. 9.0 4. 9.6.2 20..6 2. 6. 22.. 9.0. 2.2 6. 2.8.4. 8.0.9 8.6 4.4 9. 4.8 9.. 20.9 6.2 2.8 6.9 unit size 2802 outdoor air temp. CDB 4.0CWB 20.0CDB.0CWB 2.CDB 6.0CWB 2.0CDB indoor air temp..0cwb 24.CDB 8.0CWB 26.0CDB 9.0CWB 2.0CDB 20.0CWB 28.0CDB 22.0CWB 0.0CDB 24.0CWB 2.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 0.0 2.9 8.0 2.2 9.0 26.4 9.9 2.4 20.6 28. 2. 29.2 22.0 0.0 22.6.8 2.9.2 2.0 2.0 2.. 24.8 8. 26.0 9.6 26.9 20. 2.8 2.0 28. 2.6 29. 22.2.2 2. 2. 24.6 4.0 2..4 24. 8. 2.6 9. 26. 9.9 2.4 20.6 28.2 2.2 29.0 2.8 0. 2. 2. 24.2 6.0 22.. 2.9 8.0 2. 8.9 26.0 9.6 26.9 20. 2. 20.9 28. 2.4 0. 22.. 2.8 8.0 22. 6.8 2.. 24. 8.6 2. 9.2 26.4 9.9 2.2 20. 28.0 2. 29.6 22..0 2. 20.0 2.9 6. 2..4 24.2 8.2 2. 8.9 2.9 9. 26. 20. 2. 20. 29. 2.9 0.4 22.9 2.0 2. 6.4 22.9.2 24.0 8. 24.8 8. 2. 9.4 26.4 9.9 2.2 20. 28.8 2. 0. 22. 2.0 2. 6. 22.4 6.9 2.. 24.4 8.4 2.2 9.0 26.0 9.6 26. 20. 28. 2. 29.6 22. 2.0 20.9.8 22.0 6.6 2..4 2.9 8.0 24. 8.6 2. 9.2 26.2 9. 2. 20.9 29.0 2.9 2.0 20.. 2.6 6. 22.6. 2.. 24. 8. 2.0 8.8 2. 9. 2.2 20. 28.4 2.4 29.0 20.. 2.2.9 22.2 6. 2.0. 2.8.9 24. 8.4 2.2 9.0 26. 20. 2.9 2.0.0 9. 4.8 20..6 2.8 6.4 22..0 2..6 24.0 8. 24. 8.6 26. 9. 2. 20.6.0 9. 4. 20.. 2. 6. 22. 6.6 22.8.2 2.. 24.2 8.2 2.6 9. 26.8 20.2.0 8.9 4.2 9.9.0 20.9. 2.6 6. 22. 6.8 2.0. 2..8 2. 8.9 26.2 9..0 8..9 9. 4. 20.4.4 2..9 2.9 6. 22..0 2.2.4 24. 8. 2.6 9. 9.0 8..6 9.0 4. 20.0.0 20..6 2.4 6. 22.0 6.6 22.6. 24.0 8. 2. 8.9 TC: Total Capacity [kw] SHC: Sensible Heat Capacity [kw] 6 EN

6 Part Load Performance 6-. Indoor unit: RAV-SM2242DT-E(TR) Outdoor unit: RAV-SM2244AT8-E Power Power Capacity Capacity consumption consumption Q (W) Q (W) W (W) W (W) MINIMUM 9800 260 9800 20 RATING 20000 200 22400 6490 Outdoor temperature ( C) 46 40 0 2 20 Outdoor temperature ( C) 0 2 0 0 20 *: Protection operation Load (%) 00 90 80 0 60 0 40 0 20 0 Q 880 880 40 20 080 8820 8640 8640 8640 8640 W 60 00 90 480 940 00 90 90 90 90 Q 8920 00 40 240 0 9460 920 920 920 920 W 0 620 40 400 640 2860 00 00 00 00 Q 20000 8000 6000 4000 2000 0000 9800 9800 9800 9800 W 200 609 082 489 9 266 260 260 260 260 Q 2080 890 6860 460 260 040 00 00 00 00 W 660 640 40 880 40 240 020 020 020 020 Q 2240 990 0 00 280 00 080 080 080 080 W 660 200 40 90 2900 2280 290 290 290 290 Q 2220 20900 880 620 90 60 80 80 80 80 W 60 40 990 290 2660 2090 260 260 260 260 Load (%) 00 90 80 0 60 0 40 0 20 0 Q 200 240 260 890 620 0 820 820 820 820 W 60 6020 4980 4060 220 2480 280 280 280 280 Q 240 22080 9620 0 420 2260 00 00 00 00 W 680 0 420 80 00 20 2690 2690 2690 2690 Q 22400 2060 920 680 440 200 9800 9800 9800 9800 W 6490 460 420 680 2920 220 20 20 20 20 Q 20900 880 620 460 240 040 940 940 940 940 W 6290 290 480 0 280 280 2490 2490 2490 2490 Q 80 680 4980 0 240 960 890 890 890 890 W 980 00 40 90 2690 200 20 20 20 20 Q 460 60 00 0240 880 0 6400 6400 6400 6400 W 20 440 00 00 290 840 200 200 200 200 Q 460 60 00 0240 880 0 6400 6400 6400 6400 W 20 440 00 00 290 840 200 200 200 200 Q 0 280 000 960 820 6880 6020 6020 6020 6020 W 0 440 90 2920 220 90 2040 2040 2040 2040 Q 2600 40 0080 8820 60 600 0 0 0 0 W 4940 460 440 2800 2220 0 960 960 960 960 Q 0620 960 8490 40 60 0 460 460 460 460 W 4660 920 240 2640 200 60 840 840 840 840 Q 8690 820 690 6080 20 40 800 800 800 800 W 480 690 00 2480 90 20 0 0 0 0 EN

6-2. Indoor unit: RAV-SM2802DT-E(TR) Outdoor unit: RAV-SM2804AT8-E Power Power Capacity Capacity consumption consumption Q (W) Q (W) W (W) W (W) MINIMUM 9800 60 9800 20 RATING 2000 80 2000 80 Outdoor temperature ( C) 46 40 0 2 20 Outdoor temperature ( C) 0 2 0 0 20 *: Protection operation Load (%) 00 90 80 0 60 0 40 0 20 0 Q 600 600 600 4200 20 040 8640 8640 8640 8640 W 60 60 60 200 4000 2980 90 90 90 90 Q 260 980 40 20 00 0880 920 920 920 920 W 990 620 600 4800 690 20 60 60 60 60 Q 2000 2000 8400 600 800 00 9800 9800 9800 9800 W 80 09 682 440 440 264 60 60 60 60 Q 24240 2820 990 690 40 220 00 00 00 00 W 80 680 20 440 90 280 0 0 0 0 Q 2460 2290 200 820 280 20 080 080 080 080 W 490 6080 4860 80 2940 290 2880 2880 2880 2880 Q 2600 2400 260 8690 6020 0 80 80 80 80 W 680 0 4460 0 200 200 2640 2640 2640 2640 Load (%) 00 90 80 0 60 0 40 0 20 0 Q 260 2900 2600 2290 940 6280 020 820 820 820 W 8990 60 6260 090 400 20 2460 280 280 280 Q 290 2660 260 2000 40 480 80 00 00 00 W 820 0 940 480 840 2960 20 2690 2690 2690 Q 2000 2400 2600 8900 6200 00 0800 9800 9800 9800 W 80 6860 680 4620 60 280 220 20 20 20 Q 290 2260 200 60 0 2600 0080 940 940 940 W 900 660 00 4480 60 240 260 2490 2490 2490 Q 220 200 8060 800 40 290 900 890 890 890 W 0 620 240 4260 80 260 2060 20 20 20 Q 60 80 400 240 080 8820 00 6400 6400 6400 W 660 620 460 80 00 220 80 200 200 200 Q 60 80 400 240 080 8820 00 6400 6400 6400 W 660 620 460 80 00 220 80 200 200 200 Q 680 4920 260 600 990 8290 660 6020 6020 6020 W 640 40 40 60 290 220 0 2040 2040 2040 Q 80 60 20 060 90 90 600 0 0 0 W 6200 220 420 20 290 20 00 960 960 960 Q 2800 20 0240 8960 680 6400 20 460 460 460 W 80 4920 4080 20 260 200 600 840 840 840 Q 0480 940 880 0 6290 240 490 800 800 800 W 00 460 80 20 2480 90 0 0 0 0 8 EN

Sound Characteristics (NC Curve) Model name Measuring location Sound pressure level (db) H Under from unit. m (JIS Standard) RAV-SM2242DT-E Supply static duct Suction static duct 4.6 m.0 m. m RAV-SM2802DT-E RAV-SM2242DT-E RAV-SM2802DT-E 90 90 Octave band sound pressure level (db) 80 0 60 0 40 0 20 NC-0 NC-60 NC-0 NC-40 NC-0 NC-20 Octave band sound pressure level (db) 80 0 60 0 40 0 20 NC-0 NC-60 NC-0 NC-40 NC-0 NC-20 0 6 2 20 00 000 2000 4000 8000 0 6 2 20 00 000 2000 4000 8000 Octave band frequency (Hz) Octave band frequency (Hz) EN 9

8 Fan Characteristics 8 RAV-SM2242DT-E Standard air volume : 600m /h. Current of fan motor (A) 6. 6. High static pressure tap (0Hz) Medium static pressure tap (0Hz) 4. 4 Low static pressure tap External static pressure (Pa) 00 20 200 0 00 High static pressure tap (0Hz) 0 Low static pressure tap (0Hz) 2880 000 200 400 600 800 4000 4200 420 Medium static pressure tap (0Hz) Lower limit of air volume Air volume (m /h) Upper limit of air volume 8. RAV-SM2802DT-E Standard air volume : 4200m /h 8 Current of fan motor (A). 6. 6. 4. Low static pressure tap High static pressure tap (0Hz) Medium static pressure tap (0Hz) 4 0 External static pressure (Pa) 00 20 200 0 00 High static pressure tap (0Hz) 0 Low static pressure tap (0Hz) 60 600 4000 4400 4800 040 Medium static pressure tap (0Hz) Lower limit of air volume Air volume (m /h) Upper limit of air volume 0 EN

9 Capacity Correction Connecting pipe length and lift difference between indoor units vs. capacity correction value 0 20 Height of Outdoor unit H(m) 0 0 0 00% 99% 98% 9% 96% 9% 94% 9% 92% 9% 90% 89% 88% 8% 86% 20 8% 0 0 20 0 40 0 60 0 Pipe length (m) 0 20 Height of Outdoor unit H(m) 0 0 0 00% 99% 98% 9% 96% 9% 94% 9% 20 0 0 20 0 40 0 60 Pipe length (m) 0 EN

2-, TAKANAWA -CHOME, MINATO-KU, TOKYO, 08-004, JAPAN Copyright 200 TOSHIBA CARRIER CORPORATION, ALL Rights Reserved.