Floodlight Series 6121

Similar documents
Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Floodlight LED Series 6525

Floodlight LED Series 6525

Compact Sheet-Steel Light Fittings Series 6114/1

Floodlight LED Series 6125

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight Series 6521/4

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Tubular Light Fitting with LED Series 6036

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Terminal Boxes Series 8125

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6402/2

LED Linear Luminaire Series EXLUX 6402

Plug and Socket Devices SolConeX 16 A Series 8570

Sheet-Steel Light Fittings Series 6014 / 6414

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Load disconnect switch Series 8146/5-V11

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Control Buttons / Switches for Panel Mounting Series 8003

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Tank Inspection Lights Series 6122

Terminal Boxes Series 8125

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Position Switches Series 8074/2

Position Switches Series 8070/2

Position Switches Series 8060/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Operating Instructions

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Compact Sheet-Steel Light Fittings Series 6114

7 Lighting Technology

Terminal Boxes Series 8252/1

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Pendant Light Fitting IEC

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Sheet Steel Emergency Light Fitting Series 6018

Control switch/load disconnect switch Series 8008

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Ex UPS standard Series 8265

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Metal Position Switch Series 8074

EWE. Ex de. Cooling fins

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Linear Luminaire for Fluorescent Lamps

Safety Switches Series 8537

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

EWE. Cooling fins. Ex de

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Linear fittings EVDL LED fitting - zones 21, & 22

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

K: bracket type. L: pole type

Control Buttons Series 8082

EXEL-L. Detail of the internal side. Transparent polycarbonate

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

EX-D ENCLOSURES AND DISTRIBUTIONS

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

Linear fluorescent luminaire LED V-CG-S

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Operating Instructions

Battery Boxes Series 8316

M-0. M-0... series control, monitoring and signalling devices. Ex e

FHL. Ex d. Body in aluminium

ABG Cable Glands Installation Procedure

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Linear fittings EVNL LED fitting - zones 2, & 22

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

PY, SPY; FSQC, FP; EPC; AP

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

Operating Instructions

CCAI, CCAIF, CCAIF..H

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

INSTRUCTION MANUAL (ATEX / IECEx)

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Transcription:

www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options halogen lamps (QT) 500 W halogen metal halide lamps (HIT) up to 400 W sodium vapour high pressure lamps (HST) up to 400 W ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x 18674E00 Explosion Protection Global (IECEx) Gas and dust IECEx BVS 14.0071X Ex de IIB + H 2 T* Gb Ex de IIC T* Gb Ex tb IIIC T* C Db * temperature classes and surface temperatures see technical data Europe (ATEX) Gas and dust Certifications and certificates Certificates Ship approval BVS 14 ATEX E 110 X E II 2 G Ex de IIB + H 2 T* Gb E II 2 G Ex de IIC T* Gb E II 2 D Ex tb IIIC T* C Db * temperature classes and surface temperatures see technical data IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR), India (PESO) BV only for 6121/1312-2151-...-...-..3-. and 6121/1312-2251-...-...-..3-. 150 W and 250 W HID, with spezialised bracket and armoured cable between lamp enclosure and ballast enclosure. WebCode 6121B /1

Selection Table Version Connection cable between enclosure and connection box Light aperture Lamps 1) Lamp wattage Order number Art. no. Weight Standard 220... 240 V AC/DC 0, 50, 60 Hz Standard 230 V Standard 240 V Offshore 220... 240 V AC/DC 0, 50, 60 Hz without standard standard without kg QT 500 W 6121/1312-1500-0101-102-514-2 226109 27.000 QT 500 W 6121/1322-1500-0101-102-514-2 226110 27.000 HIT / HST 150 W 6121/1312-2151-1111-111-514-2 221505 33.500 250 W 6121/1312-2251-1111-111-514-2 221506 34.500 400 W 6121/1312-2401-1111-111-514-2 221507 36.900 HIT / HST 150 W 6121/1322-2151-1111-111-514-2 221508 33.500 250 W 6121/1322-2251-1111-111-514-2 221509 34.500 400 W 6121/1322-2401-1111-111-514-2 221510 36.900 HIT / HST 150 W 6121/1312-2151-1111-111-614-2 221606 33.500 250 W 6121/1312-2251-1111-111-614-2 221607 34.500 400 W 6121/1312-2401-1111-111-614-2 221608 36.900 HIT / HST 150 W 6121/1322-2151-1111-111-614-2 221609 33.500 250 W 6121/1322-2251-1111-111-614-2 221610 34.500 400 W 6121/1322-2401-1111-111-614-2 221611 36.900 QT 500 W 6121/1312-1500-0101-102-513-1 221621 27.000 QT 500 W 6121/1322-1500-0101-102-513-1 221622 27.000 Offshore 230 V armoured HIT / HST 150 W 250 W 6121/1312-2151-1111-311-513-1 6121/1312-2251-1111-311-513-1 221521 221522 38.250 39.250 400 W 6121/1312-2401-1111-311-513-1 221576 41.250 HIT / HST 150 W 6121/1322-2151-1111-311-513-1 221577 38.250 250 W 6121/1322-2251-1111-311-513-1 221586 39.250 400 W 6121/1322-2401-1111-311-513-1 221605 41.250 Offshore armoured HIT / HST 150 W 6121/1312-2151-1111-311-613-1 221612 38.250 240 V 250 W 6121/1312-2251-1111-311-613-1 221613 39.250 400 W 6121/1312-2401-1111-311-613-1 221617 41.250 HIT / HST 150 W 6121/1322-2151-1111-311-613-1 221618 38.250 250 W 6121/1322-2251-1111-311-613-1 221619 39.250 400 W 6121/1322-2401-1111-311-613-1 221620 41.250 Order Number Supplement Connection terminal Terminal 3 x 4 mm 2 6121/1...-...-...1-...-...-. Terminal 3 x 6 mm 2 6121/1...-...-...2-...-...-. Cable glands 3 x M20 with 1 cable gland and 2 stopping 6121/1...-...-...-..1-...-. plugs (HIT / HST) 2 x M20 with 1 cable gland and 1 stopping plug (QT) 3 x M25 with 1 cable gland and 2 stopping plugs (HIT / HST) 2 x M25 with 1 cable gland and 1 stopping plug (QT) 6121/1...-...-...-..2-...-. 6121/1...-...-...-..3-...-. 6121/1...-...-...-..4-...-. /2

Note Technical Data Electrical data Lamps Variant Enclosure Bracket Standard single powder-coated sheet steel, single powder-coated Offshore double powder-coated stainless steel SS316L without powder-coating The luminaires are supplied without lamps. Please order them as accessories. 1) QT HIT HST QT IEC 60357 HIT IEC 61167 HST IEC 60662 Halogen lamps Metal halide lamps High-pressure sodium lamps Ballast QT without Rated operational voltage U e HIT / HST magnetical ballast Lamps QT HIT HST 500 W 150 W 250 W 400 W 150 W 250 W 400 W 230 (+/- 6%) V AC, 50 Hz x x x x x x x 240 (+/- 6%) V AC, 50 Hz x x x x x x 208 (+/- 6%) V AC, 60 Hz x x x x 220 (+/- 6%) V AC, 60 Hz x x x x x x x 240 (+/- 6%) V AC, 60 Hz x x x x x x /3

Technical Data Current consumption Lamp Lamp power Supply current in A 220... 230 V AC/DC 0, 50, 60Hz QT 500 W 2.17 Lamp Lamp power Compensated Power factor cos φ Supply current in A Inrush current in A Uncompensated Power factor cos φ Supply current in A Inrush current in A 230 V AC, 50 Hz HIT / HST 150 W 0.95 0.79 1.50 0.40 1.80 2.70 HIT / HST 250 W 0.92 1.30 2.00 0.40 3.00 4.20 HIT 400 W 0.93 2.00 2.40 0.43 4.20 5.80 HST 400 W 0.91 2.10 2.50 0.43 4.45 6.00 240 V AC, 50 Hz HIT / HST 150 W 0.96 0.76 1.50 0.40 1.80 2.70 HIT / HST 250 W 0.94 1.23 2.00 0.40 3.00 4.20 HIT 400 W 0.96 1.90 2.40 0.43 4.20 5.80 HST 400 W 0.92 2.00 2.50 0.43 4.45 6.00 208 V AC, 60 Hz HIT / HST 150 W 0.94 0,80 1.50 0.42 1.80 2.70 HIT 400 W 0.97 1,90 2.50 0.44 4.20 5.80 HST 400 W 0.96 2,30 2.80 0.44 4.45 6.00 220 V AC, 60 Hz HIT / HST 150 W 0.96 0.75 1.50 0.42 1.80 2.70 HIT / HST 250 W 0.90 1.50 2.00 0.40 3.00 4.20 HIT 400 W 0.98 1.80 2.40 0.44 4.20 5.80 HST 400 W 0.98 2.20 2.70 0.44 4.45 6.00 240 V AC, 60 Hz HIT / HST 150 W 0.97 0.68 1.50 0.42 1.80 2.70 HIT / HST 250 W 0.91 1.35 2.00 0.40 3.00 4.20 HIT 400 W 0.97 1.60 2.30 0.44 4.20 5.80 HST 400 W 0.98 2.00 2.60 0.44 4.45 6.00 /4

Technical Data Inrush current Energy efficiency class Connection cable between enclosure and connection box Ambient conditions Temperature class, max. surface temperature Ambient temperature, gas group max. light fittings per circuit breaker with the maximum network impedance of 1 Ohm: compensated uncompensated QT HIT/HST HIT/HST 500 W 150 W 250 W 400 W 150 W 250 W 400 W B10A 4 5 3 2 2 1 1 B16A 7 8 5 3 4 2 1 B20A 9 10 6 4 5 3 2 B25A 11 12 8 5 6 4 2 C10A 4 7 5 3 4 2 1 C16A 7 11 7 4 6 3 2 C20A 9 14 9 5 7 4 3 C25A 11 17 11 7 9 5 4 EEI A2 prewired with special ignition silicone cable - armoured or unarmoured Lamp Lamp power Temperature class max. surface temperature T a ( +50 C T a ( + C T a = +40 C T a = + C QT 500 W T3 T3 +158 C +178 C HIT / HST 150 W T4 T4 +86 C +106 C HIT / HST 250 W T4 T3 +120 C +140 C HIT / HST 400 W T3 T3 +152 C +172 C Lamp Lamp power Ambient temperature Gas group Note QT 500 W T a = -20... +60 C IIC T a = -60... +60 C IIB + H 2 HIT / HST 150 W, 250 W T a = -20... +60 C IIC T a = -60... +60 C IIB + H 2 lamp start at T a ) -35 C 400 W T a = -20... +60 C IIC T a = -60... +60 C IIB + H 2 lamp start at T a ) -35 C Mechanical data Degree of protection IP66 (IEC 60529) Protection class I Enclosure material seawater-resistant cast aluminium (AlSiMg) (LM25) Material cover lamp enclosure Brass powder-coated Colour Standard single powder-coated, Offshore double powder-coated, RAL 7032, other on request Bracket Standard: sheet steel, single powder coated Offshore: stainless steel SS316L (1.4404 or. V4A) without powder-coating Mounting / Installation Operating position Horizontal mounting Cable entry HIT / HST 3x M20x1.5 with 1 cable gland and 2 stopping plugs or 3x M25x1.5 with 1 cable gland and 2 stopping plugs QT 2x M20x1.5 with 1 cable gland and 1 stopping plug or 2x M25x1.5 with 1 cable gland and 1 stopping plug Connection L + N + PE, max. 4 mm 2 or max. 6mm 2 /5

Light distribution curve typical typical spot 200 300 400 600 400 800 500 1000 600 1200 30 15 0 15 30 cd/klm 72% C0 - C180 C90 - C270 30 15 0 15 30 cd/klm 77% C0 - C180 C90 - C270 16637E00 250 W HST 250 W HST spot 16638E00 for further light distribution curves, see www.stahl-ex.com Accessories and Spare Parts Designation Figure Description Art. no. Weight Socket key Socket key for opening and closing of lamp enclosure and connection enclosure kg 223778 0.350 16990E00 Halogen lamps QT 05355E00 Power Lamp holder Voltage current 500 W E40 230 V 10250 Im 108874 0.120 Halogen metal halide lamps HIT 05355E00 150 W E40 230 V 14500 Im 250 W E40 230 V 20000 Im 109130 0.135 109132 0.200 400 W E40 230 V 42000 Im 109134 0.135 High pressure sodium lamps HST 05355E00 150 W E40 230 V 17500 Im 250 W E40 230 V 33200 Im 109129 0.143 109131 0.149 400 W E40 230 V 56500 Im 109133 0.210 Ring bolt M10, direct mounting in insert nuts, 1 pair 118560 0.210 05378E00 Mounting bracket 18198E00 Mounting bracket with accessories Material: sheet steel, single powder-coated Mounting bracket with accessories Material: stainless steel V4A (1.4404; X2Cr-Ni-Mo17-12- 2; S31603) 251923 251922 /6

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Light visor Anti-glare grid with accessories 230041 2.300 Material: stainless steel V2A (1.4301; X5Cr-Ni18-10; S 30400) 16611E00 Impact protection grid Impact protection grid with accessories Material: stainless steel V2A (1.4301; X5Cr-Ni18-10; S 30400) 230045 0.500 Grease 16612E00 Special grease BLASOLUBE 300; 1 tin 105077 1.070 19599E00 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 6121/1 Floodlight, Halogen (QT) 6121/1 Floodlight, Halogen metal halide lamps (HIT), High pressure sodium lamps (HST) 540 [21,26] 520 [20,47] 370 [14,57] 285 [11,22] 486 [19,13] 452 [17, 80] 410 [16,14] 370 [14,57] 285 [11,22] 400 [15,75] 6 8 0 [2 6,77 ] 400 [15,75] 53 2 [2 0,94 ] 6 8 0 [2 6,77 ] 250 [9,84] 6121/13..-...-...-...-..3-. 6121/13..-...-...-...-..4-. 3 x ø 13 [ 3 x ø 0,51] 18558E00 250 [9,84] 3 x ø 13 [ 3 x ø 0,51] 18557E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /7