DiaMaxATR High-Throughput Single Reflection Diamond ATR

Similar documents
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

Sure Coat 90 Degree Spray Extension

Centrifuge Operator / Service Manual

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

Agilent 210/218 - Isocratic Pump

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE

Installing the Integral Platen Blow Off Valve

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

BX-308 BAM-1020 SERVICE TOOL KIT MANUAL

Agilent 210/218 - Binary Pump

Genesys 20 Calibration and Maintenance

INSTALLATION AND OPERATING INSTRUCTIONS

TS1251 PRESSURE DISPENSER USER'S MANUAL

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

Changing the Printer Paper Monthly

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

EVOS M5000 Imaging System

High Power, RF Excited EUV Flow Light Source EUV X LHP500FL Operating Manual

INSTALLATION INSTRUCTIONS PARTS LIST. SUPPLIES REQUIRED Isopropyl alcohol Shop towel Masking tape Tape measure. Door visor (front left) INSTALLATION

Page 1. File: Motolight caliper one-piece Date: 8/14/2006

Fisher 657 Diaphragm Actuator Sizes and 87

ASX / OUTLANDER SPORT SHIFT KNOB MZ525507EX INSTALLATION AND HANDLING INSTRUCTIONS

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

CGD8800X CGD8800X220 Combustible Gas Detector

INSTALLATION INSTRUCTIONS

TOSHIBA Thermal Printer B-SX6T/SX8T SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Asepsis 21 Delivery Unit

Encore Manual Powder Spray Gun Trigger Switch Replacement

Lefty, SuperMax, Olaf Solo Air Assembly Upgrade

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

Bulb Renewal OVERVIEW

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

DL/DS Series Diaphragm Valve

I N ST R UC T I ON MODEL 6801 MEAT SAW MODEL 6801 ML Previous models covered by this manual: 6801 ML

Installation Instructions for the EVO3 Height-Adjustable Ultimate Short Shifter

XLR-8 60 Extended Rack Autosampler

Rollstar Shade Installation Instructions

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

VW Shift Paddle Kit Installation Instructions

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

CHEMINSTRUMENTS HOT ROLL LAMINATOR MODEL HL-100, HL-101 OPERATING INSTRUCTIONS

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

ASSEMBLY INSTRUCTIONS / OWNERS MANUAL AIR BIKE AB-1

Installation Instructions HURST COMPETITION AND BILLET/PLUS SHIFTER Mustang w/5-speed Manual Transmission (GT only)

Bulb Renewal TOP ACCESS COVER

Artisan Scientific QUALITY INSTRUMENTATION GUARANTEED

Performance Tech Support 1(800)

INSTALLATION AND OPERATING INSTRUCTIONS

MM PISTON PUMP

PEARL DRUM PEDAL. Instruction Manual

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

Installation Instructions For Motor Control Center (MCC) Units

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

Maintenance Adjustments

250L Cartridge Dual Seal

Installation Instructions

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

Halogen NiMH. Evolution USER GUIDE

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

Titan Safe Owner s Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE CONDITIONING HEATED SYSTEM

Agilent SD-1 Purification System ml/min

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

Installation & Programming Manual. Quick Reference

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION

Techcon Systems TS5000 Series Rotary Valve

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Assembly Instructions

SERVICE LETTER Transmittal Sheet HC-SL

LED Pinspot 2. Snapshot. User Manual

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

BRF 700 Fan Bike. * This item is for consumer use only and it is not meant for commercial use.

StepWave ion guide: cleaning instructions addendum

Eldex Universal Fraction Collector Operator s Manual

CorkSport ort Mazda 3 Adjustable Shifter Mazdaspeed 3, Mazda 3 6-speed and Mazda3 SkyActiv 6-speed

Meinzer II TM. Testing Sieve Shaker

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Hill 90C/Air90C Table

BRF 700 BRF 701. Fan Bike OWNER S MANUAL. * This item is for consumer use only and it is not meant for commercial use.

LMT Lens/Optics Cleaning Procedure. Lens Cleaning Procedure

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Toyota Prius Interior Light Upgrade

NOTE: DISCONNECT MAIN POWER LOCK OUT AND TAG BEFORE PERFORMING ANY PROCEDURES IN THIS SECTION.

Easy Tool Retracting System SR2159

Transcription:

www.harricksci.com DiaMaxATR High-Throughput Single Reflection Diamond ATR USER S MANUAL HARRICK SCIENTIFIC PRODUCTS, INC. 141 Tompkins Ave, 2 nd floor Pleasantville, NY 10570 (800) 248-3847 FAX (914) 747-7209

TABLE OF CONTENTS General Information Unpacking... 1 Technical Support... 1 Feedback... 1 About the DiaMaxATR... 2 Installation and Alignment Open Beam Spectrum... 3 Getting Ready... 3 Purge Installation... 4 Installation... 5 Alignment... 6 Throughput... 9 Operation Cleaning the ATR Crystal... 10 Background Spectrum... 10 Solid Samples... 10 Powders... 11 Liquids and Pastes... 11 Using the Optional Equipment Volatiles Cover... 12 Temperature Controlled Liquid Cells... 12 Installation... 12 Fluid/Electrical Connections... 14 Replacing the Heaters... 15 Replacing the Thermocouple... 15 Heated Stage... 16 Installation... 16 Fluid/Electrical Connections... 17 Replacing the Heater... 18 Replacing the Thermocouple... 18 Appendix A Mounting the Harrick Rail Plate... 19 Appendix B Validation... 20 Appendix C Replacing the Sampling Plate... 22 Appendix D Optional and Replacement Parts... 24 MVD-M

GENERAL INFORMATION UNPACKING Before proceeding to installation of the accessory, make sure that all of the parts on the included Checklist are present. See Appendix E. If any parts are missing or damaged, contact Harrick Scientific immediately. TECHNICAL SUPPORT For additional information please contact our Technical Support Center at 800-248-3847 between 9 a.m. and 5 p.m. EST; or e-mail your questions to: techsupport@harricksci.com FEEDBACK Your comments and suggestions are welcome. Please send them to: Harrick Scientific Products, Inc. PO Box 277 141 Tompkins Ave, 2 nd floor Pleasantville, NY 10570 Phone: 800-248-3847; Fax: 914-747-7209 E-mail: info@harricksci.com Web: www.harricksci.com 1 of 24

ABOUT THE DiaMaxATR The DiaMaxATR is a high performance single reflection diamond ATR, compatible with most FTIR spectrometers. The accessory has a fixed 45 incident angle and the supplied high performance diamond is suitable for use from 4000 cm -1 to 550 cm -1, with limited signal-to-noise in the region of the diamond lattice bands around 2000 cm -1. The DiaMaxATR features a convenient horizontal sampling surface and a user removable sampling plate for ease of cleaning. For solid sampling, it includes a built-in pressure applicator with slip-clutch to provide good contact between the sample and the ATR crystal. The pressure applicator swings out of the way to enable unobstructed access to the sampling surface. The DiaMaxATR is enclosed and includes a fitting for purge line. Available options include a force sensor with digital display for precise control of the force applied to compress solids against the ATR crystal in addition to flow and temperature controlled liquid cells. Liquids, pastes and slurries are analyzed by simply covering the sampling area with the sample. Liquids can be placed on the crystal with an eyedropper or syringe. Pastes can be simply smeared over the sampling surface. Powders and other solids are analyzed by placing a small amount of the sample on the sampling surface and applying pressure. 2 of 24

INSTALLATION AND ALIGNMENT OPEN BEAM SPECTRUM Prior to installation, collect an open beam background spectrum (no accessory in the sample compartment). This spectrum should be used later to verify the throughput. GETTING READY Before installing the DiaMaxATR, familiarize yourself with the accessory and its various components by referring to the drawing found below. The accessory includes a purgeable chassis with a high performance diamond ATR sampling plate installed. Slip Clutch Pressure Arm ATR Sampling Plate Purge Collar (2) Mirror Controls Access Knob (2) Purge Fitting Figure 1. The DiaMaxATR 3 of 24

INSTALLATION AND ALIGNMENT PURGE INSTALLATION PURGE SLEEVES Loosen the thumbscrews and push the purge sleeves in to retract them (Figure 2). Thumbscrew Purge Sleeve Figure 2 Purge Sleeve PURGE LINE For quicker purging or if the spectrometer has windows on the beam ports, connect an additional purge line to the fitting on the front of the DiaMaxATR, shown in Figure 3. Purge Line Figure 3 Purge Line 4 of 24

INSTALLATION AND ALIGNMENT INSTALLING THE DiaMaxATR RAIL MOUNTING If your spectrometer is equipped with rails: Install the accessory onto the rails. NOTE: If you received the Harrick rail plate with your DiaMaxATR, first mount the supplied rails directly onto the floor of the sample compartment (see Appendix A). Move the DiaMaxATR along the rails until the spectrometer focal point is in the center of the accessory. Lock the DiaMaxATR in place by tightening the locking mechanism knob. Extend the purge sleeves until they firmly contact the sides of the sample compartment. Lock the purge sleeves in place with the thumbscrews. FIXED FLOOR MOUNTING Install the DiaMaxATR onto the floor of the sample compartment using the base plate provided. Extend the purge sleeves to the walls of the spectrometer and tighten the thumbscrews on the purge collars. 5 of 24

INSTALLATION AND ALIGNMENT ALIGNMENT This accessory has been pre-aligned prior to shipment. Only minor adjustments should be required to optimize the performance to your spectrometer: Once the accessory is installed, set the spectrometer to measure the energy on the detector. Rotate the mirror control access knobs a quarter of a turn, so the holes are vertical instead of horizontal. Mirror Control Access Knob (2) Closed Open Figure 4 Accessing the mirror adjustments NOTE: Make sure that the ATR Sampling Plate has been correctly installed. The plate should be pushed down as far as it will go. Feed the supplied 3/32 ball driver through the lower hole in the left knob and engage it on the screw inside. Make minute adjustments to maximize the energy on the detector. Remove the ball driver and insert it in the upper hole in the left knob. Adjust to maximize the energy. Repeat this procedure with the two adjustments on the right. Continue adjusting both sets until no significant gain in energy is achieved. CAUTION: The two turn adjustments are continuous, without stops. Stop adjusting if resistance is felt or damage may occur. 6 of 24

INSTALLATION AND ALIGNMENT If the accessory has been locked in place, it must be unlocked before adjusting the height of the accessory. Feed the supplied 3/32 ball driver through the locking screw access hole on the left side of the accessory (see Figure 5) and engage it in the screw below. Turn the screw counterclockwise to release the locking mechanism. Locking Screw Access Figure 5 Unlocking To adjust the height of the accessory, feed the supplied 3/32 ball driver through the height adjustment control access hole on the right side of the accessory (see Figure 6) and engage it in the screw below. Height Adjustment Control Access Figure 6 Height adjustment 7 of 24

INSTALLATION AND ALIGNMENT Then turn the ball driver to make minute height adjustments to maximize the energy on the detector. Turning the driver clockwise will elevate the accessory. Counter-clockwise turning will lower it. Be sure to apply slight downward pressure on the accessory when lowering it. Confirm that the signal is still maximized with regard to the mirror adjustments. Repeat as necessary until no significant gain in energy is achieved. Rotate the mirror control access knobs counterclockwise, a quarter of a turn, so the holes are horizontal instead of vertical, closing the accessory for purge LOCKING Once the accessory has been installed and aligned, it should be secured in place. To lock the accessory, feed the supplied 3/32 ball driver through the height adjustment control access hole on the left side of the accessory (see Figure 7) and engage it in the screw below. Rotate the ball driver clockwise to tighten the screw and lock the accessory in position. Locking Screw Access Figure 7 Locking CAUTION: The accessory must be unlocked before removal or height adjustment. 8 of 24

THROUGHPUT To confirm the performance of your accessory, it should be tested before first use and at regular intervals thereafter. VERIFYING THE THROUGHPUT Make sure that the specified background spectrum is the previously collected open beam background spectrum. This background spectrum should be obtained with the accessory removed from the dovetail and temporarily set aside. Clean the ATR element. See the Operation section for details. With the accessory and its sampling plate installed, collect a transmittance spectrum. NOTE: Make sure that the ATR sampling plate has been correctly installed. The plate should be pushed down as far as it will go. Transmittance [%] 0 5 10 15 20 25 30 35 40 Transmittance [%] 0 5 10 15 20 25 30 35 40 4000 3500 3000 2500 2000 1500 Wavenumber cm-1 1000 500 4000 3500 3000 2500 2000 1500 Wavenumber cm-1 1000 500 FIR Diamond Figure 8 Throughput. High Performance Diamond Record the percent transmittance at 2700 cm -1. The throughput should be at least 15% with the high performance diamond installed. The spectra should resemble those shown above in Figure 8. 9 of 24

OPERATION CLEANING THE CRYSTAL NOTE: The sampling surface of the ATR element is the small rectangle located in the center of the top of the sampling plate. The sampling surface of the ATR crystal should be cleaned before each use. To clean the sampling surface of the crystal, wipe with a cotton swab or lens tissue dampened with a low residue solvent. Use very light pressure while wiping. Methyl ethyl ketone (MEK), isopropyl alcohol or acetone is recommended. BACKGROUND SPECTRUM Collect the background single beam spectrum with the accessory in the sample compartment. SOLID SAMPLES Raise the pressure head by turning the pressure applicator knob counterclockwise. Place the sample face down on the center of the ATR crystal. APPLYING PRESSURE Turn the built-in slip clutch (Figure 9) clockwise until adequate pressure is applied. Pressure is sufficient when the absorption band intensity no longer significantly changes with increased pressure or when the slip clutch begins to slip and the guide lines on the slip clutch base no longer move. Pressure Applicator Knob/Slip Clutch Slip Clutch Base Pressure Arm Guide Line ATR Crystal Figure 9 Pressure Applicator Knob 10 of 24

OPERATION SAMPLE SPECTRUM Record the sample spectrum. Loosen the pressure applicator. Remove the sample. Clean the crystal prior to running the next sample. POWDERS Place a small amount (covering at least a 2 mm diameter area) of the sample on the center of the crystal. Apply pressure carefully so the powder is not displaced from the center of the crystal. Record the sample spectrum. NOTE: To avoid spilling powder in the spectrometer, carefully remove the solid sampling plate and clean it outside the spectrometer. Wipe the sample off the crystal with a damp cloth. Clean the crystal. LIQUIDS AND PASTES Raise the pressure applicator about 1/8 away from the surface of the sampling plate. Swing the pressure applicator out of the way. Place a small amount (covering at least a 2 mm diameter area) of the sample on the center of the crystal. CAUTION: If the liquid sample is volatile, the use of the optional liquid cell is recommended The liquid cell can be filled with a Luer-Lok syringe in a glove box or other enclosed environment. NOTE: For liquid and paste analysis, no pressure is needed. Record the sample spectrum. Wipe the sample off the crystal. Clean the crystal. 11 of 24

USING THE OPTIONAL EQUIPMENT USING THE VOLATILES COVER Place a few drops of the volatile sample on the center of the crystal. Place the cover slide over the sample. Record the sample spectrum. Clean the crystal and the cover slide. Figure 10 Volatiles Cover TEMPERATURE CONTROLLED LIQUID CELLS The DiaMaxATR has optional heated and flow cells for operation up to 200C. The liquid cells are equipped with a cooling conduit for near-ambient or low temperature operation and are assembled with either Luer or Swagelok fittings. INSTALLATION Clean the ATR crystal prior to installation of the cell. Turn the pressure applicator knob counterclockwise to raise the pressure applicator well above the sampling plate. Loosen the arm locking knob and swing the pressure applicator out of the way, either to the left or right Arm Locking Knob Pressure Applicator Knob/Slip Clutch Sampling Plate Threaded Holes (2) Before After Figure 11 Swinging the pressure applicator to the side 12 of 24

USING THE OPTIONAL EQUIPMENT Make sure the o-ring and o-ring groove is clean and free of dust. Insert the o-ring into the recess in the bottom of the cell. Locate the cell over the sampling plate, so the two screws align with the threaded holes and the barbed fittings face forward. O-Ring Figure 12. O-ring installation Thread and tighten the screws to secure the cell to the accessory. Fittings, Luer or Swagelock (2) Mounting Screws (2) Barbed Fittings (2) Thermocouple Heater Wires Figure 13 Liquid cell with Swagelok Fittings affixed to the DiaMaxATR. 13 of 24

USING THE OPTIONAL EQUIPMENT FLUID / ELECTRICAL CONNECTIONS If heating is desired, connect the thermocouple and the heater to a suitable temperature controller. If cooling or operation near-ambient is desired, use 1/4 tubing to connect the two cooling ports to a thermostated chiller. User a hose clamp to secure the tubing to the barbed fittings. To use the cell equipped with Luer fittings, remove the Luer plugs if they are installed. Fill a Luer Lock syringe with ~0.3 ml of liquid. Engage the Luer Lock on the fitting on the cell and inject the liquid. For volatile samples, reinstall the Luer plugs to prevent evaporation. CAUTION: Do not install the Luer plugs unless the cell is being operated at near-ambient temperature. Do not touch the hot surfaces during above-ambient operation. Do not operate above 200C. To use the cell equipped with Swagelok fittings, connect the supplied 1/8 Swagelok nuts to appropriate adapters and tubing to flow liquid through the cell. NOTES: Purging is recommended during operation at elevated temperatures. Be careful when removing the heated liquid cells, since the o-ring may stick to the sampling plate. 14 of 24

USING THE OPTIONAL EQUIPMENT REPLACING THE HEATERS To replace the heaters, use a 0.050 hex driver to loosen the two set screws. Using a 1/16 hex driver, loosen the clamping screw just enough to unclamp the ground wire and side it out. Then slide the heaters out. If a heater sticks, insert a rod into the knockout hole on the opposite side of the cell from the heater and push the heater out. Reverse this procedure to install the new heater, taking care to route the thermocouple wire under the clamp when securing the clamping screw as needed. Clamp Clamping Screw Thermocouple Fitting Set Screws (2) REPLACING THE THERMOCOUPLE Figure 14 Replacing the Temperature Controllable Liquid Cell heaters and thermocouple. Use a 1/16 hex driver to loosen the clamping screw and remove the thermocouple wire from under the clamp. Then unscrew the thermocouple fitting. Remove the two ferrules and nut from the thermocouple. Slide the nut onto the replacement thermocouple, followed by the two ferrules in the order shown below. Then feed the end of the thermocouple into its hole, as far as it will go. Slide the nut down to engage the thread and tighten. Then route the thermocouple wire through the clamp and tighten the clamping screw. Nut Ferrules (2) Thermocouple Figure 14 Ferrule Orientation 15 of 24

USING THE OPTIONAL EQUIPMENT HEATED STAGE The DiaMaxATR has an optional heated stage for operation up to 200C. The heated stage is equipped with a cooling conduit for near-ambient or low temperature operation. INSTALLATION Clean the ATR crystal prior to installation of the cell. Turn the pressure applicator knob counterclockwise to Arm Locking Knob raise the pressure applicator above the sampling plate. Loosen the arm locking knob and swing the pressure applicator out of the way, either to the left or right. Locate the heated stage mounting over the sampling plate as shown below and tighten the thumbscrews to secure it in place. Pressure Applicator Knob/Slip Clutch Threaded Holes (2) Sampling Plate Before After Figure 15 Swinging the pressure applicator to the side Thumbscrews (2) Figure 16 Affixing the heated stage mounting bracket 16 of 24

USING THE OPTIONAL EQUIPMENT INSTALLATION If an ambient temperature single beam background spectrum is desired, collect it. Clean the underside of the pressure pad on the heated stage. Place the sample on top of the ATR crystal. Align the two holes in the heated stage over the pins and lower the heated stage into position. Swing the pressure applicator back into position. Pressure Pad Heated Stage FLUID / ELECTRICAL CONNECTIONS Figure 17 Affixing the heated stage mounting bracket If heating is desired, connect the thermocouple and the heater to a suitable temperature controller. If cooling or operation near-ambient is desired, use 1/4 tubing to connect the two cooling ports to a thermostated chiller. Use a hose clamp to secure the tubing to the barbed fittings. CAUTION: Do not use the force sensor to measure the force applied when operating at elevated temperatures. The force sensor can withstand the specified maximum operating temperature but does not display the correct applied force. Do not touch the hot surfaces during above-ambient operation. Do not operate above 200C. NOTE: Purging is recommended during operation at elevated temperatures. 17 of 24

USING THE OPTIONAL EQUIPMENT REPLACING THE HEATERS To replace the heaters, use a 1/16 hex driver to unscrew the three screws that secure the PTFE insulator to the heated block. Separate the PTFE insulator from the heated block. To replace the heaters, use a 0.050 hex driver to loosen the two set screws that secure the heaters in place. Then slide the heaters out. Reverse this procedure to install the new heaters and to reinstall the PTFE insulator. Mounting Screws Thermocouple Fitting PTFE Insulator Figure 18 Replacing the Heated Stage heaters and thermocouple. REPLACING THE THERMOCOUPLE Unscrew the thermocouple fitting. Then remove the two ferrules and nut from the thermocouple. Slide the nut onto the replacement thermocouple, followed by the two ferrules. Then feed the end of the thermocouple into its hole, as far as it will go. Slide the nut down to engage the thread and tighten. Nut Ferrules (2) Thermocouple Figure 14 Ferrule Orientation 18 of 24

APPENDIX A MOUNTING THE HARRICK RAIL PLATE Harrick Rail Plate To install the supplied rail plate onto the floor of the sample compartment of your spectrometer: Remove any existing sample holders from the floor of the spectrometer. Install the rail plate in the orientation indicated in Figure 12. See Table 1 for the appropriate screws/holes for your spectrometer. BACK Accessory Mounting Plate C B D A C A C B D FRONT Figure 19 Screw and Pin Positions for Rail Plate FTIR Manufacturer Model Holes AGILENT/VARIAN/DIGILAB All models(di4, DI6, DI8) A THERMO-MATTSON Polaris, Galaxy, RS Infinity, Genesis, Satellite (MA2, B MA3) PERKIN ELMER Spectrum 1, 65, 100, 400, Frontier, Optica (P10, C P11) THERMO-NICOLET Nexus, Avatar, Magna, Impact, 380, 4700, 5700, 6700, is50, 8700 (NI6, NI8) D Table 1 Screw and Pin Positions for Rail Plate 19 of 24

APPENDIX B VALIDATION For applications requiring higher photometric accuracy, a validation procedure on a specific liquid sample is recommended. An example, using water, is shown here. Collect a background spectrum with the accessory in the sample compartment. Place a few drops of a liquid sample to cover most of the ATR crystal. Collect a sample spectrum. Convert the spectrum into absorbance. Absorbance Units 0.0 0.1 0.2 0.3 0.4 0.5 4000 3500 3000 2500 2000 Wavenumber cm-1 1500 1000 500 Figure 20 Absorbance of Water. Choose two peaks at different ends of the spectrum. Write down the wavenumbers and absorbance values at these peaks. Every time the validation procedure is performed, the data should be within the noise level of those recorded the first time. On the next page, a table is provided to record these values. 20 of 24

USING THE OPTIONAL EQUIPMENT LIQUID SAMPLE USED WAVENUMBER (cm -1 ) ABSORBANCE VALUE 21 of 24

APPENDIX C REPLACING THE SAMPLING PLATE REMOVING THE SAMPLING PLATE To remove the sampling plate for cleaning or replacement: Turn the pressure applicator knob counterclockwise to raise the pressure applicator well above the sampling plate. Loosen the arm locking knob and swing the pressure applicator out of the way, either to the left or right. Then use the access slots to grab the sampling plate from underneath and lift it up off the accessory. Arm Locking Knob Pressure Applicator Knob/Slip Clutch Access Slot (2) Before After Figure 21 Swinging the pressure applicator to the side 22 of 24

APPENDIX C INSTALLING A SAMPLING PLATE To reinstall the sampling plate after cleaning or install a replacement: Make sure the pressure applicator is raised well above the sampling plate and that it has been swung out of the way, either to the left or right. Orient the sampling plate so its slot faces the front of the accessory. Lower the plate so it locates on the pin in the recess for the plate. Push down on the plate to seat it firmly in place. Slot Figure 22 Orienting the sampling plate 23 of 24

APPENDIX D OPTIONAL AND REPLACEMENT PARTS Replacement High Performance Diamond sampling plate... MVD-ATR-WC FIR Diamond sampling plate... MVD-ATR-W Volatiles cover... FAS-XCS Temperature controllable liquid cell with Luer fittings... MVD-FSL-3 Temperature controllable liquid cell with Swagelok fittings... MVD-FSS-3 Viton o-ring for the liquid cell... ORV-010 Kalrez o-ring for the liquid cell... ORK-010 Temperature controllable solid sampling adapter... MVD-SSP-3 K-type thermocouple... 008-144 24 V Heater Assembly for the temperature controlled cells and heated stage... UQA-HTR Temperature Controller Kit (110V)... ATK-024-3 Temperature Controller Kit (220/240V... ATK-024-4 24 of 24

Manual Part No. MVD-M-01 2017 Harrick Scientific Products, Inc.