Approved for use as fixed fire extinguishing system for machinery spaces and cargo pump rooms.

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Approval Engineer: Nina Thorvaldsen Moberg Inger-Helene Hals Head of Section

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

This is to certify: Application : Certificate No: TAS000011V Revision No: 1. That the Lifting set for Offshore containers and Portable Offshore Units

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

VID Fire-Kill Marine and Offshore Product Catalogue Year 2015 Rev 1.

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

This is to certify: Application : Certificate No: TAS000011V. That the Lifting set for Offshore containers and Portable Offshore Units

GW M5 WATER MIST NOZZLE K-5, LOW PRESSURE, NON-AUTOMATIC

DNVGL-CP-0110 Edition March 2016

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

TYPE APPROVAL CERTIFICATE

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

Technical Information

DEPARTMENT OF MARINE SERVICES AND MERCHANT SHIPPING (ADOMS) REGULATORY AMENDMENTS ENTERING INTO FORCE DURING JANUARY 2017

DOCK AND SHIP TO SHIP HOSE

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Yellow Point WARNING NEVER EXCEED PUBLISHED WORKING LOAD LIMIT. Catalog No YP. Copyright 2017 YOKE Industrial Corp. All Rights Reserved.

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

CIRCULAR IMO FAQ on the sulphur limits in Emission Control Areas (ECAs)

Guideline No.: E-03(201610) E-03 MOTORS. Issued date: October 28,2016. China Classification Society

Shipping Guidance Notice 069. EU Monitoring, Reporting and Verification (MRV) regulations and IMO Data Collection Data Collection System (DCS)

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES. Comments on document FP 46/5/8. Submitted by Japan

Danish Fire Laboratories ApS

CLASS STATUS REPORT WADI HAM FUJAIRAH PORT AUTHORITY. Report date: IMO number: DNV GL number: 28722

Monitoring, reporting and verification of CO 2 emissions from ships - EU MRV regulation and obligations and the parallel IMO activities

HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)) APRIL 2008

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

TYPE APPROVAL CERTIFICATE

Examples of the application of Permanent Means of Access to Tankers

ST. VINCENT AND THE GRENADINES

INFORMATION BULLETIN No. 165

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

Part 6 Additional class notations Chapter 7 Environmental protection and pollution control

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE

AIR LUBRICATION SYSTEM INSTALLATION

Ballast Water Management

Part 1: Land Applications Machinery Spaces, Industrial Hazards, Combustion & Gas Turbine Enclosures, Light & Ordinary Hazards

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

This is to certify: Application : Certificate No: TAA00000FJ. That the Miscellaneous. with type designation(s) K-Bridge and K-Nav system platforms

Technical specification for NDC 40 NO Rescue Boat Davit

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

MSN 047 June 2014 MANX SHIPPING NOTICE DEPARTMENT OF ECONOMIC DEVELOPMENT

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2, THE FSS CODE AND RELATED FIRE TEST PROCEDURES

Information Notice (rev3) DEPARTMENT OF MARINE SERVICES AND MERCHANT SHIPPING (ADOMS) Ballast Water Management

Technical specification for NDA 40 NO Rescue Boat Davit

CONTROL OF OIL RESIDUES (SLUDGE) AND MARPOL ANNEX I

TYPE APPROVAL CERTIFICATE

ST. VINCENT AND THE GRENADINES

To: Owners, Technical Managers, Deputy Registrars, Fleet Managers, Surveyors, Recognised Organisations

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

Systems and Arrangement for Meeting Regulations in Emission Control Areas (ECA)

CLASS STATUS REPORT WADI SAHAM FUJAIRAH PORT AUTHORITY. Report date: IMO number: DNV GL number: 28725

Section 4 SURVEYS SPECIAL SHIP TYPES

NORTH AMERICAN ECA AND NEW FUEL SULFUR CONTENT REQUIREMENTS

LIST OF MANUALS,PLANS AND DRAWINGS REQUIRED ON BOARD. Class ARS. Leading Partner for New Horizons...

HAZARDOUS AREA CLASSIFICATION (APPLICATION OF SOLAS REGULATION II-1/45.11)

Report No.: Name of Ship: Plans referred during Initial Survey:

CHAPTER II-1 D. Construction subdivision and stability, machinery and electrical installations

Recommendation for petroleum fuel treatment systems for marine diesel engines

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

INFORMATION BULLETIN No. 165

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

Ballast Water Convention

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

USER INFORMATION, CURRENT RULE CHAPTERS AND INDEX

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

Main changes in BV Rules for Steel Ships

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.2 and 28.3)

ANNEX 8 RESOLUTION MEPC.102(48) Adopted on 11 October 2002 GUIDELINES FOR SURVEY AND CERTIFICATION OF ANTI-FOULING SYSTEMS ON SHIPS

Gearless / full scantling cellular container vsl with poop, forecastle and open top cargo hold

IMO REQUIREMENTS JULY 2018 TO MAY 2021

Annex-1: Summary of new IMO requirements from 1 January2017 Resolution New Ship Existing Ship Subject Remarks Ship type Size Compliance date

TECHNICAL ALERT No Rev.01

IMO REVIEW OF MEPC.1/CIRC.511 AND RELEVANT MARPOL ANNEX I AND ANNEX VI REQUIREMENTS. Comments on the Report of the Correspondence Group

PACIFIC MARINE SERVICES

NaviSafe nv. Emdenweg 11 Haven Antwerpen Belgium T F

"Exhaust Gas Scrubbers Abatement System as an Alternative under IMO MARPOL Annex VI''

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.2 and 28.3 and 30.2)

RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1997 TO AMEND THE INTERNATIONAL CONVENTION FOR THE

Transcription:

Certificate No: TAF00000D7 This is to certify: That the Waterbased Fixed Fire Extinguishing System with type designation(s) VID Fire-Kill K6 Pacific Fine Water Spray (ceiling), VID Fire-Kill K6 North Sea Fine Water Spray (ceiling), VID Fire-Kill K1 Biscay Water Mist (bilge), VID Fire-Kill F1 Tampa Water Mist (bilge)., VID Fire-Kill B1 Hudson (bilge), VID Fire-Kill B1 Bengal (bilge) Issued to Vid Fire-Kill ApS Svendborg, Denmark is found to comply with DNV GL statutory interpretations DNVGL-SI-0364 SOLAS interpretations DNV GL rules for classification Ships DNV GL offshore standards Application : Approved for use as fixed fire extinguishing system for machinery spaces and cargo pump rooms. Products approved by this certificate are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until 2021-08-10. Issued at Høvik on 2016-08-11 DNV GL local station: Fredericia for DNV GL Approval Engineer: Tomasz Werchowicz Petter Langnes Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 1 of 6 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Product description VID Fire-Kill K6 Pacific Fine Water Spray (ceiling), VID Fire-Kill K6 North Sea Fine Water Spray (ceiling), VID Fire-Kill K1 Biscay Water Mist (bilge), VID Fire-Kill F1 Tampa Fine Water Spray (bilge), VID Fire-Kill B1 Hudson (bilge) and VID Fire-Kill B1 Bengal (bilge) are a dry pipe water mist system, composed of nozzles, stainless steel piping, section valves, strainers and electrically driven pumps. Only the nozzles are type approved by this certificate. The system is to be designed in accordance with IMO MSC/Circ. 1165 Revised Guidelines for the Approval of Equivalent Water Based Fire-Extinguishing Systems for Machinery Spaces and Cargo Pump Rooms as amended by MSC.1/Circ.1269 and MSC.1/Circ.1386. Pumps, pipes, couplings, valves and other systems components are subject to case by case approval The nozzles are manufactured by Vid Fire-Kill Aps, Svendborg, Denmark. Application/Limitation The nozzles are to be installed to the following specifications: Volume and height of protected spaces (K6 Pacific) Maximum ceiling height of protected space 1) : Maximum volume of protected space 2) : 3842 m 3 The system is to be designed with one layer of ceiling mounted nozzles and one layer of bilge nozzles. Areas under platforms and other similar obstruction shall be protected by additional nozzles. For areas of limited height, nozzles with lower installation height (shorter spacing and less flow) are recommended used. 1) Standard casings need in general not to be considered when assessing this height limitation. 2) This will in general be accepted as the maximum net volume for any protected space (corresponding to a typical gross volume of 4520 m 3 ). This volume shall include bilges, casings, etc. Volume and height of protected spaces (K6 North Sea) Maximum ceiling height of protected space 1) : Maximum volume of protected space 2) : 2862 m 3 The system is to be designed with one layer of ceiling mounted nozzles and one layer of bilge nozzles. Areas under platforms and other similar obstruction shall be protected by additional nozzles. For areas of limited height, nozzles with lower installation height (shorter spacing and less flow) are recommended used. 1) Standard casings need in general not to be considered when assessing this height limitation. 2) Volume can be increased to 5036 m 3 (height remain at ) based on IMO MSC.1/Circ.1385. This volume shall include bilges, casings, etc. Ceiling mounted nozzles (K6 Pacific) 3.0 x 3.0 m 1.5 m Maximum coverage area per nozzle (average): 9.0 m 2 Maximum ceiling height of nozzles: Minimum pressure at nozzles: 8.0 bar Nozzles type: VID F-K K6 Nozzle orientation: Downwards The spray nozzles shall normally be installed approximately 0.1-0.2 m below deck. Where the spray nozzles are located less than 3 m above the protected object, a narrower nozzle spacing than 3 x 3 m or the use of spray nozzles intended for lower installation height should be considered. Arrangement to be approved case-by-case. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 2 of 6

Ceiling mounted nozzles (K6 North Sea) 3.0 x 3.0 m 1.5 m Maximum coverage area per nozzle (average): 9.0 m 2 Maximum ceiling height of nozzles: Minimum pressure at nozzles: 9.0 bar Nozzles type: VID F-K K6 Nozzle orientation: Downwards The spray nozzles shall normally be installed approximately 0.1-0.2 m below deck. Where the spray nozzles are located less than 3 m above the protected object, a narrower nozzle spacing than 3 x 3 m or the use of spray nozzles intended for lower installation height should be considered. Arrangement to be approved case-by-case. Bilge nozzles (K1 Biscay) 1.7 x 0.5 m 0.85 m Maximum coverage area per nozzle (average): 0.43 m 2 Height of nozzle above tank top/floor level: 0.37 0.45 m 1) 11.0 bar VID F-K K1 1) The bilge plate was located at 0.75 m in the fire test. Installations on vessels with bilges and nozzle higher or lower than these figures will be considered case by case. 2) Spacing between nozzles pointing the same direction is 0.5 m along the distribution pipe and 1.7 m between distribution pipes. Nozzles of two adjacent rows shall be installed pointing against each other. The nozzles along a row (distribution pipe) are installed with alternating pointing directions, thus with half spacing between them (0.25 m). The manufacturer s pre-fabricated N-pipe should be used as distribution pipe (consisting of a PN16 Stainless Steel pipe with prefabricated holes and threading for mounting of the K1 nozzles). Bilge nozzles (F1 Tampa) 1.75 x 0.75 m 0.85 m Maximum coverage area per nozzle (average): 0.66 m 2 Height of nozzle above tank top/floor level: 0.35 0.37 m 1) 11.0 bar VID F-K F1 1) The bilge plate was located at 1.1 m in the fire test. Installations on vessels with bilges and nozzle higher or lower than these figures will be considered case by case. 2) Spacing between nozzles pointing the same direction is 0.75 m along the distribution pipe and 1.75 m between distribution pipes. Nozzles of two adjacent rows shall be installed pointing against each other. The nozzles along a row (distribution pipe) are installed with alternating pointing directions, thus with half spacing between them (0.375 m). The manufacturer s pre-fabricated N-pipe should be used as distribution pipe (consisting of a PN16 Stainless Steel pipe with prefabricated holes and threading for mounting of the F1 nozzles). Bilge nozzles (B1 Hudson) 1.5 x 4.0 m Maximum coverage area per nozzle (average): 6.0 m 2 Height of nozzle above tank top/floor level: 0.30 0.60 m 1) 10.5 bar B1 1) The bilge plate was located at 1.0 m in the fire test. Installations on vessels with bilges and nozzle higher or lower than these figures will be considered case by case. 2) Spacing between nozzles pointing the same direction is 1.5 m along the distribution pipe and 4.0 m between distribution pipes. Nozzles of two adjacent rows shall be installed pointing against each other. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 3 of 6

3) Approved STHAMEX AFFF foam concetrate (or equivalent) is to be applied with 1% admixture to water after 7 minutes of activating the system. Bilge nozzles (B1 Bengal) 1.5 x 4.0 m Maximum coverage area per nozzle (average): 6.0 m 2 Height of nozzle above tank top/floor level: 0.30 0.50 m 1) 6 bar B1 1) The bilge plate was located at 1.1 m in the fire test. Installations on vessels with bilges and nozzle higher or lower than these figures will be considered case by case. 2) Spacing between nozzles pointing the same direction is 1.5 m along the distribution pipe and 4.0 m between distribution pipes. Nozzles of two adjacent rows shall be installed pointing against each other. 3) Approved FOMTEC AFFF foam concetrate (or equivalent) is to be applied with 1% admixture to water after system activation. Nozzle information Nozzle VID F-K K6 *) (Pacific) VID F-K K6 *) (North Sea) VID F-K K1 **) (Biscay) VID F-K F1 **) (Tampa) Application k-factor [lpm/bar 1/2 ] Flow at operating pressure [lpm] Operating pressure [bar] Drawing no. Ceiling 5.6 15.84 8.0 100714-836 Rev.C Ceiling 5.6 16.80 9.0 100714-836 Rev.C Bilge 0.9 2.98 11.0 100303-807 Rev.B Bilge 1.1 3.7 11.0 120216-1043 dated 03.03.2010, 120216-1044 dated 27.06.2011 Bilge 2.8 9.1 10.5 71203-478B Rev. B VID F-K B1 ***) (Hudson) VID F-K B1 ***) Bilge 2.8 6.85 6.0 71203-478B (Bengal) *) The nozzle is made of Naval brass + NiSn / AISI 316, and have a maximum rated pressure of 16 bar. **) The nozzle is made of Naval brass + NiSn / AISI 316 + AISI 303 housing, and have a maximum rated pressure of 16 bar. ***) The nozzle is made of Naval brass / SS316 and have a maximum rated pressure of 16 bar. For all applications: A. The pumps or pump unit and the pressure tank are to be delivered with DNV GL product certificate. Other system components are to be certified or inspected in accordance with DNV GL Rules. B. The back up pump arrangement is to be approved on a case by case basis. C. The pump unit and section valves shall be installed in a room having ambient temperature between +4 degree C and +45 degree C. D. Pipes, couplings and other components are regarded as Class III piping. E. For nozzles F1 and K1 piping and piping components shall be made of stainless steel or equivalent material. For nozzles K6 and B1 piping and piping components can be made of of galvanised steel or equivalent material. F. For nozzles F1 and K1 only fresh water shall be used in the system. For nozzles K6 and B1 only water complying with maker s specification shall be used in the system. This includes testing and flushing operations. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 4 of 6

The following items are to be approved and filed by the flag administration for each project: - System arrangement plans including routing of pipes, location of nozzles, section valves, release stations, pump unit with back-up capacity and water supply. - Documentation of power supply and control system. - Specification of pipes, section valves, electrical motors, pumps and associated components. - Pressure drop calculations and water mist capacity calculations. - Design, installation, operation and maintenance manual. Other documents: - Pumps or pump unit are to be delivered with DNV GL product certificates. - Documentation for other components (according to EN 3.1B and EN 2.2, as applicable) shall be submitted to the site representative of DNV GL. Installation testing: - System to be cleaned in accordance with the maker s specification, installation, operation and maintenance manual. - Water to be sampled from the sprinkler tank, the pump unit and from a representative number of sections and tested for the relevant contaminations identified by maker s specification - All sections should be tested with full flow of water through the nozzles. - Manual release of all section valves and start of pumps shall be carried out. - Alarms inside protected space and at a manned control stations and switchover to emergency power shall be tested. - Other tests as required by DNV GL Rules (pressure testing of piping, etc.) and according to maker's manual shall be carried out. Periodical testing: - The periodocal testing shall comply with instructions from flag administration, DNV GL Statutory Interpretations and maker s maintenance manual. - Water to be sampled annually from sprinkler tank, pump unit and from a representative number of sections and tested for the relevant contaminations identified by maker s specification. - Not less than 5 sprinkler heads shall be tested annually(not the same section each year). Further testing will be required in case of failure(s). Type Approval documentation Certification in accordance with Class Programme DNVGL-CP-0338, October 2015. Fire Performance Testing: - Test report No. 110315-52 dated 21 March 2011, - Test report No. 110630-55 dated 18 August 2012, - Test report No. 111025-59 dated 28 October 2011, - Test report No. 120308-65 dated 19 March 2012, - Test report No. 71205-016 dated 31 March 2008, - Test report No. 140229-136 dated 30 April 2014, all from Danish Fire Laboratories (DFL), Svendborg, Denmark. Component Testing: - Test report No. 110414-1 dated 15 April 2011, - Test report No. 110414-2 dated 24 August 2011, - Test report No. 111004-7 dated 28 October 2011, - Test report No. 120424-8 dated 30 April 2012, - Test report No. 090109-2 dated 15 April 2011, - Test report No. 141028-148 dated 3 December 2014, all from Danish Fire Laboratories (DFL), Svendborg, Denmark. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 5 of 6

Drawings from manufacturer: - 100714-836 Rev.C dated 20 April 2012, - 100303-807 Rev.B dated 03 March 2010, - 120216-1043 dated 03 March 2010, - 120216-1044 dated 27 June 2011, - 71203-478E Rev.E dated 3 December 2014, - 100714-839 Rev.G dated 28 November 2014. Tests carried out Fire performance testing according to IMO MSC/Circ.1165. Component testing according to IMO MSC/Circ.1165, as amended by MSC.1/Circ.1269 Appendix A. Marking of product The nozzles and other main component in the system are to be marked with type designation. Periodical assessment DNV GL s surveyor is to be given permission to perform Periodical Assessments at any time during the validity of this certificate and at least every second year. The arrangement is to be in accordance with procedure described in Class Programme DNVGL-CP-0338, Section 4. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 6 of 6