PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Similar documents
OPTOFLEX G62,5/125: rubber cables with fiber optic

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Global data. Electrical parameters

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

Crane Cables General Catalogue

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CABLES FOR A MOVING WORLD TRATOS VDE MTO. for Mining and Tunnelling Applications. May 2014 Tt 18-14

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

Solutions for the mining industry. Special cables for highest demands in the mining sector

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

PANZERFLEX TUNNELFLEX C A B L E S

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Cables for cable carriers and reels SYSTEMS IN MOTION

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Connecting globally. TFCrane

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

DNV-GL HH CE RoHS-II conform

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

Data sheet chainflex CF6

Data sheet chainflex CF10

Photo: HELUKABEL. Trailing Cables G 1

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Flexible power and control cables

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

ÖLFLEX CLASSIC 110 CY

Data sheet chainflex CF5

Industry Cables Special cables for industrial applications General Catalogue

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

Data sheet chainflex CF240

Data sheet chainflex CF8821

Data sheet chainflex CF140.UL

HYDROFIRM(T) KTW/W270/ACS S1BB-F and S1BBH2-F 0,6/1 kv Drinking Water Application

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

Micro Fibre Indoor Cable Multi-core (Up to 96 Fibres) Applications. Features

Data sheet chainflex CF210.UL

Data sheet chainflex CFSOFT1

Data sheet chainflex CF340

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

ENERGY. Solar Cables

CRANE, CONVEYOR, LIFT & REELING CABLES

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Power & Control Cable IEC

Power & Control Cable IEC

Data sheet chainflex CF9

ÖLFLEX CLASSIC 115 CY

Power & Control Cable IEC

20 HUBER+SUHNER RADOX SOLAR

Data sheet chainflex CF886

Data sheet chainflex CF130.UL

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

50µm µlinx Avionics Cable

14 HH EAC/CTP CE RoHS-II conform

Data sheet chainflex CF330.D

Technical attributes

ÖLFLEX CLASSIC 110 H Info Benefits

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF881

CF270.UL.D.

Data sheet chainflex CF310.UL

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Data sheet chainflex CF886

Cables for Railway Technology

Caledonian Medium Voltage Cables

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

High Voltage Copper, Smooth Aluminum Shield/Sheath

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

CF11.LC / CF11.LC.D CF14.CAT5

Harnessing the wind of change. Our cables supply societies with renewable energy.

Telephone Cables Fire Warning Cables

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Submarine Power Cables

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

TRATOS OIL&GAS NEK606

Power & Control Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Data sheet chainflex CF300.UL.D

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Datasheet Outside Plant Cable

Fiber Optic, Breakout cable, tight buffered, 900 microns

Mini Breakout Distribution Cable Multi-core ( Fibres)

Unarmoured Single-Core Cables to BS6883

MIC Unitized Plenum Cables, Fibers

Data sheet chainflex CF885.PE

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Transcription:

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes of direction within one plane, running over rollers). Mainly for mobile equipment, e.g. fast-moving container cranes, cranes, large mobile equipment and excavators. Global data Brand PROTOLON(FL) LWL Type designation (N)TSFLCGEWOEU Standard Based on DIN VDE 0250-813 Preparation of requires special skills and use of elaborate tools. It is therefore recoended that performance of this work is entrusted to our customer service (Factory assembly). Please provide the connection dimensions. Design features Electrolytic copper tinned, finely stranded, class F (refer also to DIN VDE 0295) Insulation PROTOLON Special compound based on high-quality EPR (at least 3GI3); improved mechanical and electrical characteristics Electrical field control Inner semiconductive layer of EPR, outer semiconductive layer of modified EPR, removable in warm condition Core identification Natural coloured insulation with black semiconductive layer Optical Fiber Fibre core diameter: 62.5, 50 or 9μm; diameter across the cladding: 125μm; diameter over the coating: 250μm. Design available with 6,12, 18 or 24 fibres. Fibre class: G50/125μm G62,5/125μm E9/125μm Type: Graded-index fibre Graded-index fibre Monomode fibre - Attenuation at 850 nm: <2,8 db/km <3,3 db/km - - Attenuation at 1310 nm: <0,8 db/km <0,9 db/km <0,4 db/km - Attenuation at 1550 nm: - - <0,3 db/km - Bandwidth at 850 nm: >400 MHz >400 MHz - - Bandwidth at 1300 nm: >1200 MHz >600 MHz - - Numerical aperture: 0,2 ± 0,02 0,275 ± 0,02 0,14 ± 0,02 1300 nm: 1550 nm: Fiber coding Fiber covering Core arrangement Sheath system Marking Specially developed color code for identification of the individual fibres Hollow core with filling compound, Basic material: ETFE, Compound: 7YI 1, Natural color Parallel core arrangement; earth conductor splitted and concentrically distributed around each core. Optical Element: six tubes, laid up around a central support element, with one, two or three optical fibers in each. PROTOFIRM Special compound based on CR, quality at least 5GM5, red colour PROTOLON (FL) LWL (N)TSFLCGEWOEU (number of cores)x(cross-section) (rated voltage) (year of manufacture) (serial number) Electrical parameters Rated voltage 3.6/6 kv permissible operating voltage AC 4.2/7.2 kv permissible operating voltage DC 5.4/10.8 kv AC test voltage 11 kv Data transmission Special design with for trouble free data transmission at high data rates Carrying Capacity description Acc. to DIN VDE 0298, Part 4 Higher values are permissible in specific cases (please consult the manufacturer). PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Chemical parameters Resistance to oil Acc. to DIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10 Weather resistance Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture Water resistance Acc. to HD 2216 Thermal parameters permissible temperature at conductor 90 C short circuit temperature of the conductor 250 C Ambient temperature for fixed installation min -50 C ; max +80 C Ambient temperature in fully flexible operation min -35 C ; max +80 C Mechanical parameters tensile load on the conductor 15 N/² Torsional stress Not allowed bending radius Acc. to DIN VDE 0298, Part 3. (Recoendation: applied cable diameter D = 1.5 x height of the flat distance with S-type directional changes 20 x D (cable diameter) Travel speed - Gantry (reeling operation): up to 120 m/min Additional tests Reversed bending test, reeling test PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6

Number of cores x cross section Part number MLFB Number diameter Bending radius free moving min. Weight (ca.) kg/km Permissible tensile force N resistance at 20 C Ω/km carrying capacity, reeled in 1 layer (3) A Short Circuit (conductor) ka 3x35+4x25/4E 3x50+4x25/4E 3x70+4x35/4E 3x95+4x50/4E 5DK3... 8.3 24.5 27.5 83.5 88.5 413 3700 1575 0.57 130 5.01 20015923 5DK3035 9.8 23.9 25.9 79.1 84.1 389 3890 2250 0.39 162 7.15 5DK3... 11.4 28.7 31.7 97.7 102.7 476 5590 3150 0.28 200 10.01 5DK3... 13.3 30.6 33.6 105.3 110.3 504 6720 4275 0.21 241 13.59 (3) Nominal current carrying capacity for rubber cables reeled in 1 layer, at 30 C ambient temperature (see also technical appendixes). Design with 12, 18 or 24 fibers and/or G50 or E9 types available upon request. PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 6/10 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes of direction within one plane, running over rollers). Mainly for mobile equipment, e.g. fast-moving container cranes, cranes, large mobile equipment and excavators. Global data Brand PROTOLON(FL) LWL Type designation (N)TSFLCGEWOEU Standard Based on DIN VDE 0250-813 Preparation of requires special skills and use of elaborate tools. It is therefore recoended that performance of this work is entrusted to our customer service (Factory assembly). Please provide the connection dimensions. Design features Electrolytic copper tinned, finely stranded, class F (refer also to DIN VDE 0295) Insulation PROTOLON Special compound based on high-quality EPR (at least 3GI3); improved mechanical and electrical characteristics Electrical field control Inner semiconductive layer of EPR, outer semiconductive layer of modified EPR, removable in warm condition Core identification Natural coloured insulation with black semiconductive layer Optical Fiber Fibre core diameter: 62.5, 50 or 9μm; diameter across the cladding: 125μm; diameter over the coating: 250μm. Design available with 6,12, 18 or 24 fibres. Fibre class: G50/125μm G62,5/125μm E9/125μm Type: Graded-index fibre Graded-index fibre Monomode fibre - Attenuation at 850 nm: <2,8 db/km <3,3 db/km - - Attenuation at 1310 nm: <0,8 db/km <0,9 db/km <0,4 db/km - Attenuation at 1550 nm: - - <0,3 db/km - Bandwidth at 850 nm: >400 MHz >400 MHz - - Bandwidth at 1300 nm: >1200 MHz >600 MHz - - Numerical aperture: 0,2 ± 0,02 0,275 ± 0,02 0,14 ± 0,02 1300 nm: 1550 nm: Fiber coding Fiber covering Core arrangement Sheath system Marking Specially developed color code for identification of the individual fibres Hollow core with filling compound, Basic material: ETFE, Compound: 7YI 1, Natural color Parallel core arrangement; earth conductor splitted and concentrically distributed around each core. Optical Element: six tubes, laid up around a central support element, with one, two or three optical fibers in each. PROTOFIRM Special compound based on CR, quality at least 5GM5, red colour PROTOLON (FL) LWL (N)TSFLCGEWOEU (number of cores)x(cross-section) (rated voltage) (year of manufacture) (serial number) Electrical parameters Rated voltage 6/10 kv permissible operating voltage AC 6.9/12 kv permissible operating voltage DC 9/18 kv AC test voltage 17 kv Data transmission Special design with for trouble free data transmission at high data rates Carrying Capacity description Acc. to DIN VDE 0298, Part 4 Higher values are permissible in specific cases (please consult the manufacturer). PROTOLON(FL)-LWL (N)TSFLCGEWOEU 6/10

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 6/10 kv: medium voltage flat reeling cable with Chemical parameters Resistance to oil Acc. to DIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10 Weather resistance Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture Water resistance Acc. to HD 2216 Thermal parameters permissible temperature at conductor 90 C short circuit temperature of the conductor 250 C Ambient temperature for fixed installation min -50 C ; max +80 C Ambient temperature in fully flexible operation min -35 C ; max +80 C Mechanical parameters tensile load on the conductor 15 N/² Torsional stress Not allowed bending radius Acc. to DIN VDE 0298, Part 3. (Recoendation: applied cable diameter D = 1.5 x height of the flat distance with S-type directional changes 20 x D (cable diameter) Travel speed - Gantry (reeling operation): up to 120 m/min Additional tests Reversed bending test, reeling test PROTOLON(FL)-LWL (N)TSFLCGEWOEU 6/10

Number of cores x cross section Part number MLFB Number diameter Bending radius free moving min. Weight (ca.) kg/km Permissible tensile force N resistance at 20 C Ω/km carrying capacity, reeled in 1 layer (3) A Short Circuit (conductor) ka 3x35+4x25/4E 3x50+4x25/4E 3x70+4x35/4E 3x95+4x50/4E 5DK4254 8.3 25.3 28.3 86.7 91.7 425 3910 1575 0.57 130 5.01 20024635 5DK4253 9.8 27.8 30.8 94.1 99.1 462 4810 2250 0.39 162 7.15 5DK4... 11.4 29.5 32.5 100.9 105.9 488 5800 3150 0.28 200 10.01 20165662 5DK4... 13.3 31.4 34.4 108.5 113.5 516 6940 4275 0.21 241 13.59 (3) Nominal current carrying capacity for rubber cables reeled in 1 layer, at 30 C ambient temperature (see also technical appendixes). Design with 12, 18 or 24 fibers and/or G50 or E9 types available upon request. PROTOLON(FL)-LWL (N)TSFLCGEWOEU 6/10

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 8,7/15 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes of direction within one plane, running over rollers). Mainly for mobile equipment, e.g. fast-moving container cranes, cranes, large mobile equipment and excavators. Global data Brand PROTOLON(FL) LWL Type designation (N)TSFLCGEWOEU Standard Based on DIN VDE 0250-813 Preparation of requires special skills and use of elaborate tools. It is therefore recoended that performance of this work is entrusted to our customer service (Factory assembly). Please provide the connection dimensions. Design features Electrolytic copper tinned, finely stranded, class F (refer also to DIN VDE 0295) Insulation PROTOLON Special compound based on high-quality EPR (at least 3GI3); improved mechanical and electrical characteristics Electrical field control Inner semiconductive layer of EPR, outer semiconductive layer of modified EPR, removable in warm condition Core identification Natural coloured insulation with black semiconductive layer Optical Fiber Fibre core diameter: 62.5, 50 or 9μm; diameter across the cladding: 125μm; diameter over the coating: 250μm. Design available with 6,12, 18 or 24 fibres. Fibre class: G50/125μm G62,5/125μm E9/125μm Type: Graded-index fibre Graded-index fibre Monomode fibre - Attenuation at 850 nm: <2,8 db/km <3,3 db/km - - Attenuation at 1310 nm: <0,8 db/km <0,9 db/km <0,4 db/km - Attenuation at 1550 nm: - - <0,3 db/km - Bandwidth at 850 nm: >400 MHz >400 MHz - - Bandwidth at 1300 nm: >1200 MHz >600 MHz - - Numerical aperture: 0,2 ± 0,02 0,275 ± 0,02 0,14 ± 0,02 1300 nm: 1550 nm: Fiber coding Fiber covering Core arrangement Sheath system Marking Specially developed color code for identification of the individual fibres Hollow core with filling compound, Basic material: ETFE, Compound: 7YI 1, Natural color Parallel core arrangement; earth conductor splitted and concentrically distributed around each core. Optical Element: six tubes, laid up around a central support element, with one, two or three optical fibers in each. PROTOFIRM Special compound based on CR, quality at least 5GM5, red colour PROTOLON (FL) LWL (N)TSFLCGEWOEU (number of cores)x(cross-section) (rated voltage) (year of manufacture) (serial number) Electrical parameters Rated voltage 8.7/15 kv permissible operating voltage AC 10.4/18 kv permissible operating voltage DC 13.5/27 kv AC test voltage 24 kv Data transmission Special design with for trouble free data transmission at high data rates Carrying Capacity description Acc. to DIN VDE 0298, Part 4 Higher values are permissible in specific cases (please consult the manufacturer). PROTOLON(FL)-LWL (N)TSFLCGEWOEU 8,7/15

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 8,7/15 kv: medium voltage flat reeling cable with Chemical parameters Resistance to oil Acc. to DIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10 Weather resistance Unrestricted use outdoors and indoors, resistant to ozone, UV and moisture Water resistance Acc. to HD 2216 Thermal parameters permissible temperature at conductor 90 C short circuit temperature of the conductor 250 C Ambient temperature for fixed installation min -50 C ; max +80 C Ambient temperature in fully flexible operation min -35 C ; max +80 C Mechanical parameters tensile load on the conductor 15 N/² Torsional stress Not allowed bending radius Acc. to DIN VDE 0298, Part 3. (Recoendation: applied cable diameter D = 1.5 x height of the flat distance with S-type directional changes 20 x D (cable diameter) Travel speed - Gantry (reeling operation): up to 120 m/min Additional tests Reversed bending test, reeling test PROTOLON(FL)-LWL (N)TSFLCGEWOEU 8,7/15

Number of cores x cross section Part number MLFB Number diameter Bending radius free moving min. Weight (ca.) kg/km Permissible tensile force N resistance at 20 C Ω/km carrying capacity, reeled in 1 layer (3) A Short Circuit (conductor) ka 3x35+4x25/4E 3x50+4x25/4E 3x70+4x35/4E 20004696 5DK5435 8.3 29.3 32.3 96.9 101.9 485 4630 1575 0.57 138 5.01 20168452 5DK5... 9.8 30 33 102.9 107.9 495 5400 2250 0.39 172 7.15 5DK5... 11.4 31.7 33.7 109.7 114.7 506 6460 3150 0.28 212 10.01 (3) Nominal current carrying capacity for rubber cables reeled in 1 layer, at 30 C ambient temperature (see also technical appendixes). Design with 12, 18 or 24 fibers and/or G50 or E9 types available upon request. PROTOLON(FL)-LWL (N)TSFLCGEWOEU 8,7/15