Type 3320, Service Manual. Serviceanleitung Service Manuel

Similar documents
Type 3360, Service Manual. Serviceanleitung Service Manuel

Type 2000, 2002, 2012

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 6213 EV, 6281 EV

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 2060, 2061, 2063, 2064, Accessories. Zubehör Accessoires

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Pneumatic Control Unit. Operating Instructions

Type Pneumatic Control Unit. Operating Instructions

Type 8798 Remote Sensor. Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type 3232, 3233, 3233 K, 3234, 3235, 3239

Type 2730, 2731, 2731 K DN Operating Instructions. Bedienungsanleitung Manuel d utilisation

BVS 13 ATEX E039X Type 8685 / Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type Control Head. Operating Instructions

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. With decentralized peripheral system ET200S (Siemens)

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type ASNU

WATERFLUX 3070 Quick Start

Pressure relief valve

Assembly and Maintenance Manual Type RSBW

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. with I/O System 750 (Wago)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instruction

Type 3280, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2-way motor valve 2-Wege-Motorventil Vanne motorisée 2 voies

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

OPTIFLUX 2000 Quick Start

Assembly instructions

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Original Operating Manual

Operating Instructions (from serial number 3000)

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Operating & Maintenance Manual For Steam Conditioning Valve

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Siemens Drives & PLCs

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A

Installation, Operation, and Maintenance Manual

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

EcoPump HP Pneumatic Horizontal Piston Pump

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Swing Piston Compressors and Vacuum Pumps

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Fisher 657 Diaphragm Actuator Sizes and 87

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

TIDALFLUX 2300 F Quick Start

Mini slide EGSC-BS-KF. Operating instructions b [ ]

Double piston rotary drive DRQD-6/... / b [ ] (en) Operating instructions

Diaphragm Vacuum Pumps and Compressors

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Service Handbook HD /97

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Technical Manual Electrical Power Supply System T4002

Diaphragm Valves Type 15

Operating instructions Accu Jet

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Throttling Pendulum Gate O-ring Replacement Procedure Rev. A, May 2012

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Electrical linear actuator with safety function MC100FSR/24

Installation, Operation, and Maintenance Manual

Pneumatic Swivel Unit SRU 20-60

ONYX VALVE CO MODEL DAC-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Elektric actuator MC50/24-C

Features. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.

Swiveling gripper finger GFS 16-40

Operating Instructions

IB PowlVac ITE-HK Remote Racking Device

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Installation and Operation Manual

Transcription:

Electromotive 2/2-way valve Elektromotorisches 2/2-Wege-Ventil Vanne électromotorisée à 2/2 voies Service Manual Serviceanleitung Service Manuel

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

Inhalt 1 THE SERVICE INSTRUCTIONS...5 1.1 Symbols...5 1.2 Definition of the term device...5 2 BASIC SAFETY INSTRUCTIONS...6 3 GENERAL INFORMATION...8 3.1 Contact addresses...8 3.2 Warranty...8 3.3 Information on the Internet...8 3.4 Auxiliary materials...8 4 OVERVIEW OF SPARE PARTS...9 4.1 Replacement part sets for Type 3320...9 4.2 Replacement part sets for Type 3321...9 4.3 Spare parts for Types 3320 and 3321...10 5 CHANGING THE SWIVEL PLATE SET...11 5.1 Removing the actuator...11 5.2 Change swivel plate set...15 5.3 Installing the actuator...16 5.4 Running X.TUNE...17 6 CHANGING THE SEAL SET...18 6.1 Remove swivel plate...18 6.2 Changing the packing gland...19 6.3 Install swivel plate...22 7 CHANGING THE VALVE SET...23 7.1 Changing the valve set...23 8 CHANGING THE ENERGY PACK...25 8.1 Removing the dummy cover...25 3

8.2 Removing LED and storage module...26 8.3 Removing actuator cover...26 8.4 Replacing the SAFEPOS energy-pack...26 9 ACCESSORIES, SPARE PARTS...28 10 PACKAGING, TRANSPORT...28 11 STORAGE...28 12 DISPOSAL...28 4

The service instructions 1 THE SERVICE INSTRUCTIONS The service instructions describe the procedure for changing spare parts of the process valves of Types 3320 and 3321. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. The service instructions contain important safety information. Failure to observe these instructions may result in hazardous situations. The service instructions must be read and understood. 1.1 Symbols DANGER! Warns of an immediate danger. Failure to observe the warning will result in fatal or serious injuries. WARNING! Warns of a potentially dangerous situation. Failure to observe the warning may result in serious injuries or death. CAUTION! Warns of a possible danger. Failure to observe this warning may result in a moderate or minor injury. NOTE! Warns of damage to property! Failure to observe the warning may result in damage to the device or the equipment. indicates important additional information, tips and recommendations. refers to information in these operating instructions or in other documentation. designates instructions for risk prevention. designates a procedure which you must carry out. indicates a result. 1.2 Definition of the term device In these instructions, the term device always refers to the Types 3320 and 3321. 5

Basic safety instructions 2 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during the assembly, operation, and maintenance. local safety regulations the operator is responsible for observing these regulations, also in relation to the installation personnel. Risk of injury from high pressure. Before working on the system or device, switch off the pressure and vent or drain lines. If switched on for a prolonged time, risk of burns or fire due to hot device surface. Keep the device away from highly flammable substances and media and do not touch with bare hands. Risk of crushing due to mechanically moving parts. Perform installation and maintenance work only in the isolated state. Devices with SAFEPOS energypack: Completely drain SAFEPOS energy-pack. Wait until LED illuminated ring goes out; the LED status must not be in LED off mode. Keep clear of the openings in the valve body. Danger due to an uncontrolled process in the event of a power failure. If devices do not have the optional SAFEPOS energy-pack, the valve remains in an undefined position in the event of a power failure. If the valve position is relevant as regards safety in the event of a power failure: Use only those devices which have the SAFEPOS energy-pack (optional energy pack). In the SAFEPOS select a valve position which is safe for the process. General hazardous situations. To prevent injuries: Do not make any internal or external changes on the device and do not subject it to mechanical stress. Only feed media specified in the data sheet into the media connections. Secure to prevent unintentional actuation. Only trained technicians may perform installation and maintenance work. The valves must be installed in accordance with the regulations applicable in the country. After an interruption in the power supply, ensure that the process is restarted in a controlled manner. Observe sequence! 1. Apply supply voltage. 2. Charge the device with medium. Observe the general rules of technology. Install the valves must in accordance with the regulations applicable in the country. 6

Basic safety instructions NOTE! Electrostatically sensitive components and modules. The device contains electronic components which react sensitively to electrostatic discharge (ESD). Contact with electrostatically charged persons or objects are hazardous to these components. In the worst case scenario, they will be destroyed immediately or will fail after start-up. Observe the requirements in accordance with EN 61340-5-1 to minimize or avoid the possibility of damage caused by a sudden electrostatic discharge. Do not touch electronic components while the supply voltage is switched on. 7

General information 3 GENERAL INFORMATION 3.1 Contact addresses Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 Email: info@buerkert.com International Contact addresses can be found on the final pages of the printed operating instructions. And also on the Internet at: www.burkert.com 3.2 Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 3.3 Information on the Internet Operating instructions and data sheets for Types 3320 and 3321 can be found on the Internet at: www.burkert.com 3.4 Auxiliary materials The following auxiliary materials are recommended in these instructions for carrying out repairs: Type of auxiliary material Auxiliary material Manufacturer s specifications Sealer and anti-seize agents Silicone grease OKS 1110-3 OKS Schmierstoffe GmbH www.oks-germany.com Lubrication paste Klüber paste UH1 96-402 Klüber Lubrication München www.klueber.de 8

Overview of spare parts 4 OVERVIEW OF SPARE PARTS 4.1 Replacement part sets for Type 3320 The following replacement part sets are available for Type 3320: Swivel plate set consisting of: graphite seal, swivel plate and dowel pin Seal set for the packing gland consisting of: individual parts of the packing gland, graphite seal and lubricant Spindle guide for the packing gland consisting of: spindle guide, graphite seal and lubricant Item. Description 1 Graphite seal 4 2 Swivel plate 3 Dowel pin Swivel plate set Valve set 1 5 4 Seal set for packing gland 3 5 Spindle guide for packing gland 2 Fig. 1: Replacement part sets for type 3320 4.2 Replacement part sets for Type 3321 The following replacement part sets are available for Type 3321: Swivel plate set consisting of: graphite seal, swivel plate and dowel pin Valve set consisting of: graphite seal, swivel plate, dowel pin and valve seat Seal set for the packing gland consisting of: individual parts of the packing gland, graphite seal and lubricant Spindle guide for the packing gland consisting of: spindle guide, graphite seal and lubricant 9

Overview of spare parts Item. Description 1 Graphite seal 5 2 Swivel plate 3 Dowel pin Swivel plate set Valve set 1 6 4 Valve seat 3 5 Seal set for packing gland 2 6 Spindle guide for packing gland 4 Fig. 2: Replacement part sets for type 3321 4.3 Spare parts for Types 3320 and 3321 SAFEPOS energy-pack. Optionally there is an energy pack for the device. If the supply voltage fails, the energy pack supplies the actuator with the required energy to move the valve into the required position which can be adjusted via the menu. SAFEPOS energy-pack Fig. 3: SAFEPOS energy-pack 10

Changing the Swivel plate set 5 CHANGING THE SWIVEL PLATE SET Before the swivel plate set can be changed, the actuator must be removed from the valve body. 5.1 Removing the actuator DANGER! Risk of injury from high pressure. Before working on the system or device, switch off the pressure and vent or drain lines. WARNING! Risk of injury if the wrong tools are used. It is dangerous to use unsuitable tools for installation work as the device may be damaged. To remove the actuator from the valve body, use an open-end wrench, never a pipe wrench. When removing the actuator from the valve body, ensure that the valve is in the open position. The valve position must be detected on the mechanical position indicator (as illustrated in Fig. 1 ). The control valve can be manually opened in 2 ways: electrically or mechanically. Mechanical position indicator Valve completely open Actuator Actuator base Valve completely closed Body connection Valve body Fig. 4: Mechanical position indicator 5.1.1 Opening valve electrically Depending on the device version, the valve is manually and electrically opened on the display or by pressing 2 buttons which are located on the LED and storage module under the dummy cover. To actuate the valve, the device must be in MANUAL operating state. The 2 buttons for opening and closing the valve are located under the dummy cover. 11

Changing the Swivel plate set DIP switches Release dummy cover DIP 4 ON Fig. 5: Setting MANUAL operating state Rotate the dummy cover counter-clockwise by 90 and remove from the actuator housing. Set DIP switch 4 to ON. The device is the MANUAL operating state. Press OPEN button until the valve is completely open. The valve position must be detected on the mechanical position indicator (see Fig. 4 ). OPEN button for opening the valve CLOSE button for closing the valve Fig. 6: Electrical manual control for devices without display module Clamp the valve body into a holding fixture. Place a suitable open-end wrench on the body connection. Do not unscrew the body connection with a tool which may damage the body connection. Unscrew the actuator off the valve body. 12

Changing the Swivel plate set 5.1.2 Opening valve mechanically When the supply voltage is not applied, e.g. during installation or in the event of a power failure, the valve can be opened with the mechanical manual control. NOTE! The mechanical manual control may be used in a de-energized state only, otherwise the device may be damaged. Rotate dummy cover counter-clockwise by 90 and remove from the actuator housing. Release dummy cover Fig. 7: Removing dummy cover from the actuator housing NOTE! Damage to the manual control by exceeding the tightening torque. If the tightening torque is exceeded on reaching the valve end position, the mechanical manual control will be damaged. Do not exceed the maximum tightening torque of 2 Nm. To adjust the valve, use an Allen key with 4 mm width across flats. The mechanical position indicator must detect when the valve reaches the end positions (see Fig. 4 ). Applying a gentle pressure, couple the mechanical manual control and simultaneously turn the Allen key counter-clockwise (see Fig. 8 ). Maximum tightening torque 2 Nm! 13

Changing the Swivel plate set Mechanical Manual Control Open valve Turn Close valve Press and rotate Fig. 8: Mechanical manual control After reaching the required valve position, remove the Allen key. The valve position must be detected on the mechanical position indicator (see Fig. 4 ). Clamp the valve body into a holding fixture. Place a suitable open-end wrench on the body connection. Do not unscrew the body connection with a tool which may damage the body connection. Unscrew the actuator off the valve body. 14

Changing the Swivel plate set 5.2 Change swivel plate set Support swivel plate on the cylindrical part using a prism. Knock out dowel pin using a suitable pin punch (see Tab. 1 ). Spindle diameter [mm] Pin punch Connection size Valve body DN [ [mm] 10 3 10,15, 20, 25, 32 and 40 14 5 50 Tab. 1: Spindle diameter with reference to DN Remove swivel plate. Graphite seal Spindle Dowel pin Swivel plate Fig. 9: Changing the swivel plate set NOTE! Important information for the problem-free and safe functioning of the device: The sealing surface and control contour of the swivel plate cannot be damaged. Place new swivel plate on the spindle. Align holes in the swivel plate with holes in the spindle. Support swivel plate on the cylindrical part using a prism. Position dowel pin and carefully knock in using a hammer. Center the dowel pin relative to the spindle axis. 15

Changing the Swivel plate set 5.3 Installing the actuator When installing the actuator, ensure that the valve is in the open position. Replace graphite seal. Straight seat valve Angle seat valve Graphite seal Fig. 10: Graphite seal WARNING! Danger if unsuitable lubricants are used. Unsuitable lubricant may contaminate the medium. In oxygen applications there is a risk of an explosion. Only use approved lubricants for specific applications, such as oxygen applications or analytical applications. Grease the external thread of the body connection (e.g. with Klüber paste UH1 96-402 from Klüber). Place a suitable open-end wrench on the body connection. Do not screw on the body connection with a tool which may damage the body connection. Screw actuator onto the valve body. Observe tightening torque (see Tab. 2 ). Connection size valve body DN [mm] Tightening torques Nm] 13, 15 45 ±3 20 50 ±3 25 60 ±3 32 40 65 ±3 50 70 ±3 65 100 ±3 Tab. 2: Tightening torques for valve body / body connection 16

Changing the Swivel plate set 5.4 Running X.TUNE After installing the actuator, run the X.TUNE function. When the X.TUNE function is run, the position controller is adjusted to the physical stroke of the actuating element used. NOTE! Do not run X.TUNE without a mandatory requirement. It is not necessary to rerun the X.TUNE function already run at the factory unless the valve body has been changed. In this case the position controller must be readjusted to the actuating element. WARNING! Danger due to uncontrolled process after running the X.TUNE function. If the X.TUNE is run under medium pressure, the controller will be incorrectly adjusted. This will result in an uncontrolled process. Never run the X.TUNE under medium pressure. Secure system against unintentional activation. 5.4.1 Adjustment using the buttons in the device The 2 buttons for running the X.TUNE are located under the dummy cover. Release dummy cover CLOSE button OPEN button Fig. 11: Adjustment of the position controller using the buttons in the device To release the dummy cover, rotate counter-clockwise by 90. Remove actuator housing. Run X.TUNE function: Do not run the X.TUNE unless it is absolutely essential. Simultaneously hold down the OPEN and CLOSE buttons for 5 s. The rapidly flashing LEDs indicate that the X.TUNE is running. When X.TUNE is complete, the LEDs have their previous status (continuous light for AUTOMATIC operating state, flashing for MANUAL operating state). 17

Changing the seal set 6 Changing the seal set Before the seal set can be replaced, the actuator must be removed from the valve body and the swivel plate must be removed. DANGER! Risk of injury from discharge of medium and release of pressure. It is dangerous to remove a device which is under pressure due to the sudden release of pressure or discharge of medium. Before removing a device, switch off the pressure. Deaerate lines. WARNING! Risk of injury if the wrong tools are used. It is dangerous to use unsuitable tools for installation work as the device may be damaged. To remove the actuator from the valve body, use an open-end wrench, never a pipe wrench. To replace the packing gland, use a special installation wrench, modified socket wrench or open-end wrench. Observe specified tightening torques. Observe exact description for removing the actuator in chapter 5.1 Removing the actuator. 6.1 Remove swivel plate WARNING! Risk of crushing by mechanically moved parts. Switch off supply voltage. For devices with SAFEPOS energy-pack: Completely drain SAFEPOS energy-pack. Wait until LED illuminated ring goes out; for this purpose, the LED illuminated display must not be in LED Off mode. Do not reach into the openings of the valve body. Knock out dowel pin using a suitable pin punch (see Tab. 1 ) Remove swivel plate. NOTE! Important for fault-free and reliable function of the device: Do not damage sealing surface or control contour of the swivel plate. 18

Changing the seal set 6.2 Changing the packing gland WARNING! Risk of injury from ejected parts. When the spindle opening is exposed, the individual parts of the packing gland are pressed out at an undefined speed when the relief bore is pressurized. Before pressurizing with compressed air, safeguard the ambient area of the discharge opening (e.g. place spindle on a firm base). Caution! Not all individual parts of the packing gland are pressed out by pressurizing with compressed air. Usually the upper gaskets remain in the packing gland tube. Replace the pressed out individual parts only. Place the open-end wrench on the body connection. Unscrew spindle guide with the aid of a modified socket wrench. A modified socket wrench is not included in the spare part set, but can be ordered separately. Order number of the modified socket wrench can be found in the operating instructions on the Internet at: www.buerkert.de. If you have any queries, please contact your Bürkert sales office. Relief bore Seal set for packing gland 3 Spindle guide Fig. 12: Spindle guide for the packing gland Place spindle on a firm base. NOTE! Individual parts of the packing gland can remain inserted in the threaded part of the packing gland tube. The individual parts are then ready to hand: 1. Before pressurizing the relief bore: Move the spindle with the aid of the mechanical manual control (see chapter 5.1.2 ) into the upper position. 2. After pressurizing the relief bore: Move the spindle with the aid of the mechanical manual control into the lower position. 19

Changing the seal set Pressurize relief bore with approx. 6 bar compressed air. WARNING! Danger if unsuitable lubricants are used. Unsuitable lubricant may contaminate the medium. In oxygen applications there is a risk of an explosion. Only use approved lubricants for specific applications, such as oxygen applications or analytical applications. Grease gaskets of the new packing gland package with the supplied lubricant. Place the individual parts on the spindle in the prescribed direction and sequence. Push packing gland into the packing gland tube. Upper gaskets Pushing direction for packing gland parts Upper pressure ring(s) Pressure spring Lower pressure ring Lower gaskets Spindle diameter 10 mm Spindle diameter 14 mm Tab. 3: Seal set for the packing gland Grease spindle guide thread with Klüber paste UH1 96-402. Screw in spindle guide. Observe tightening torque (see Tab. 4 ). Spindle diameter [mm] Connection size Valve body DN [mm] Tightening torques [Nm] 10 10, 15, 20, 25, 32 and 40 6 14 50 15 Tab. 4: Spindle guide tightening torques 20

Changing the seal set 6.2.1 Changing the packing gland for the connection size 10/15 (DN4-15) and vacuum version Before the packing gland can be changed, the actuator must be removed from the valve body and the swivel plate must be removed. An exact description for removing the actuator and the swivel plate can be found in chapters 5.1 Removing the actuator and 6.1 Remove swivel plate. Clamp the body connection in a holding device. Loosen 4 screws on the actuator base. Actuator housing Actuator base Screws Fig. 13: Removing actuator housing from the actuator base Remove actuator housing from the actuator base. Clamp the actuator base in a holding device. Unscrew spindle guide. Example tool for pressing out the packing gland package Individual parts of the packing gland package Fig. 14: Pressing out individual parts of the packing gland Using a suitable tool (e.g. screwdriver), carefully press out the packing gland package. Do not damage top of guide. 21

Changing the seal set WARNING! Danger if unsuitable lubricants are used. Unsuitable lubricant may contaminate the medium. In oxygen applications there is a risk of an explosion. Only use approved lubricants for specific applications, such as oxygen applications or analytical applications. Grease gaskets of the new packing gland package with the supplied lubricant. Insert required individual parts of the new packing gland package in the correct sequence (see Tab. 3 ). Grease spindle guide thread. Screw in spindle guide. Observe tightening torque (see Tab. 4 ). Place actuator base on the actuator housing. Tighten 4 screws crosswise. Observe tightening torque of 5 Nm. 6.3 Install swivel plate Place swivel plate on the spindle. Align holes in the swivel plate with holes in the spindle. Support swivel plate on the cylindrical part using a prism. Position dowel pin and carefully knock in using a hammer. Center the dowel pin relative to the spindle axis. Grease the thread of the valve body. Renew graphite seal. Clamp valve body in a holding device. Screw actuator into the valve body. Observe tightening torques (see Tab. 2 ). Observe exact description for installing the actuator in chapter 5.3. 22

Changing the valve set 7 CHANGING THE VALVE SET Before the valve set can be changed, the actuator must be removed from the valve body. Observe exact description for removing the valve set in chapter 5.1 Removing the actuator. 7.1 Changing the valve set Select a suitable tool insert and screw it into the installation tool. An assembly tool is not included in the valve set, but can be ordered separately. Order number of the assembly tool can be found in the operating instructions on the Internet at: www.buerkert.de. If you have any queries, please contact your Bürkert sales office. Unscrew the valve seat using the installation tool and a wrench. Clean the thread and sealing surface in the valve body using compressed air. Place the new valve seat on the installation tool. Installation tool Tool insert (according to nominal widths of the seat) Valve seat Fig. 15: Replacing the valve seat WARNING! Danger if unsuitable lubricants are used. Unsuitable lubricant may contaminate the medium. In oxygen applications there is a risk of an explosion. Only use approved lubricants for specific applications, such as oxygen applications or analytical applications. Grease the valve seat thread with a lubricant (e.g. with Klüber paste UH1 95-402 from Klüber). Manually screw the fitted valve seat into the valve body thread. 23

Changing the valve set Screw in valve seat tight using torque wrench. Observe tightening torque (see Tab. 5 ). Seat DN Screw connection Connection size valve body DN [mm] Tightening torques Uncoated seats [Nm] Coated seats [Nm] Tolerance [Nm] 4...15 10, 15 25 20 +3 20 20 35 28 +3 25 25 50 40 +5 32 32 80 65 +5 40 40 100 85 +8 50 50 120 120 +8 Tab. 5: Tightening torques for valve seat installation Grease valve body thread. Replace graphite seal. Clamp the valve body into a holding fixture. Screw actuator into the valve body. Observe tightening torques (see Tab. 2 ). Observe exact description for installing the actuator in chapter 5.3 Installing the actuator. 24

Changing the energy pack 8 CHANGING THE ENERGY PACK CAUTION! Risk of injury due to electric shock. Before removing the SAFEPOS energy-pack, switch off the supply voltage. Completely drain SAFEPOS energy-pack. Wait until the LED illuminated ring goes out; the LED status must not be in LED off mode. Setting the LED mode is described in the operating instructions at www.buerkert.com. The SAFEPOS energy-pack is located in the actuator housing. To replace it, remove the following parts from the actuator: Display module or dummy cover LED and storage module Actuator cover 8.1 Removing the dummy cover Rotate the dummy cover counter-clockwise by 90 and remove from the actuator housing. Release dummy cover Fig. 16: Removing dummy cover from the actuator housing 25

Changing the energy pack 8.2 Removing LED and storage module Fastening screws Metal housing of the LED and storage module Fig. 17: Removing LED and storage module Remove the 2 fastening screws (hexagon head key, width across flats 3 mm). Take hold of the LED and storage module on both sides of the metal housing and lift out. 8.3 Removing actuator cover Fastening screws Actuator cover Fig. 18: Removing actuator cover Loosen the 4 fastening screws (T25 hexagonal socket round screws). The screws are integrated in the actuator cover to prevent them from falling out. Remove actuator cover. 8.4 Replacing the SAFEPOS energy-pack NOTE! Recommendation: Before removing the SAFEPOS energy-pack, switch off the supply voltage. Loosen locking screw (T10 hexagonal socket round screw). Completely pull out SAFEPOS energy-pack on the bracket. 26

Changing the energy pack SAFEPOS energy-pack Locking screw (T10 hexagonal socket round screw) Fig. 19: Removing the SAFEPOS energy-pack Take SAFEPOS energy-pack out of the transport packaging. Insert SAFEPOS energy-pack into the two guiding grooves and push in all the way. Guiding groove Guiding groove Fig. 20: Inserting the SAFEPOS energy-pack Tighten locking screw (T10 hexagonal socket round screw). Apply supply voltage. 27

Accessories, spare parts 9 ACCESSORIES, SPARE PARTS CAUTION! Risk of injury and/or damage due to the use of incorrect parts. Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use original accessories and original spare parts from Bürkert only. The order numbers of the particular spare parts can be found in the operating instructions on the Internet at: www.buerkert.de 10 PACKAGING, TRANSPORT NOTE! Transport damage. Inadequately protected devices may be damaged during transportation. Protect the device against moisture and dirt in shock-resistant packaging during transportation. Prevent the temperature from exceeding or dropping below the permitted storage temperature. 11 STORAGE NOTE! Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature: -40...+70 C. 12 DISPOSAL NOTE! Damage to the environment caused by parts contaminated with media. Dispose of the device and packaging in an environmentally friendly manner! Observe applicable disposal and environmental regulations. 28 Beachten Sie die nationalen Abfallbeseitigungsvorschriften.

www.burkert.com