Multileaf damper with actuator

Similar documents
Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

For installation into ductwork

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type Pneumatic actuators

Type Pneumatic actuators

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Parts and characteristics

TYPE EK-EU SMOKE CONTROL DAMPER

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Pressure relief dampers

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Fan - Powered Terminal Unit Series Flow

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type VSD35. Nominal length up to 1500 mm: one spigot

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Marine Fire and Gas Dampers

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Ventilation grilles for installation into walls, sills or rectangular

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

TROX Prisliste Spjæld Riste Lyddæmpere K3-00

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Ceiling swirl diffusers

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

VOLUME CONTROL / REGULATING DAMPERS

INDEX. Chapter3. air master. Linear Bar Grilles

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

INDEX. Chapter1 6. air master. Volume Control Dampers

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Actionair Control and Shut Off Dampers

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Technical information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Motorized Fire Dampers

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Slot diffusers for ceiling installation

Ceiling swirl diffusers

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Duct Nozzle Diffuser. L e

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Ceiling swirl diffusers with perforated face plate

Diffusion grilles for installation in ducts

Ceiling swirl diffusers with perforated face plate

DAMPERS WE CONTROL AIR

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Zero Leakage Isolation Damper

CAV controllers Type RN

Attachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1

MOTORIZED VOLUME DAMPER

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

INDEX. Chapter2. air master. Grilles and Registers

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Particle Filter Box FKU

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

CONSTANTFLOW Volume Flow Controllers

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Displacement flow diffusers. L e

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Transcription:

JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings in walls and ceiling slabs Maximum dimensions 2000 1995 mm Casing air leakage to EN 1751, class C

Aerofoil parallel or opposed action blades Blades interconnected by external linkage (for parallel or opposed blade action) Available in standard sizes and many intermediate sizes Can be combined with external weather louvres Optional equipment and accessories Actuators: Open/Close actuators, modulating actuators Explosion-proof construction with pneumatic actuator or spring return actuator Powder-coated construction Application Multileaf dampers of Type JZ are used as an acting element in the volume flow and pressure control in air conditioning systems For shutting off ducts and openings in walls and ceiling slabs Parallel action blades are preferably used for opening/closing Opposed action blades are due to their characteristics preferably used for variable operation Stainless steel and powder-coated constructions with increased corrosion resistance Steel and stainless steel variants with brass or stainless steel bearings are suitable for use in potentially explosive atmospheres (ATEX) Special characteristics Aerofoil blades Low-maintenance, robust construction No parts with silicone Available in standard sizes and many intermediate sizes Nominal sizes B: 200 2000 mm, in increments of 1 mm Width subdivided (BM): 2001 4150 mm, in increments of 1 mm H: 180, 345, 510, 675, 840, 1005, 1170, 1335, 1500, 1665, 1830, 1995 mm (intermediate sizes 183 1993 in increments of 1 mm, except for standard size H 1 mm, H + 1 mm, H + 2 mm) Height subdivided (HM): >1998 4066 mm, in increments of 1 mm Any combination of B H Variants JZ-S: Multileaf damper with opposed blade action, made of galvanised sheet steel JZ-P: Multileaf damper with parallel blade action, made of galvanised sheet steel JZ-S-A2: Multileaf damper with opposed blade action, made of stainless steel JZ-P-A2: Multileaf damper with parallel blade action, made of stainless steel

Construction Duct connection Corner holes on both sides G: Flange holes on both sides Bearings Plastic bearings, operating temperature 20 100 C M: brass bearings, operating temperature 20 150 C E: stainless steel bearings, operating temperature 20 150 C Blades Only for steel multileaf dampers with brass or stainless steel bearings (JZ-...-M, JZ-...-E) V: reinforced blades Parts and characteristics Ready-to-install shut-off damper Blades with external linkage Drive arm Attachments Quadrant stays and limit switches: Quadrant stays to adjust the damper blades (stepless adjustment) and for capturing the end positions Open/Close actuators: Actuators for opening and closing multileaf dampers Modulating actuators: Actuators for stepless blade adjustment Pneumatic actuators: Pneumatic actuators for opening and closing multileaf dampers Explosion-proof actuators: Actuators for opening and closing multileaf dampers installed in potentially explosive atmospheres Accessories Installation subframe: Installation subframe for the fast and simple installation of multileaf dampers Construction features Rectangular casing, welded (P1: casing with screws), material thickness 1.25 mm Blades, material thickness 1 mm Flanges on both sides, suitable for duct connection, either flange holes or corner holes External linkage, robust and durable, consisting of the coupling rod and and horizontal arms Blade shafts, Ø12 mm, with notch to indicate the blade position (not for attachment ZS99) With drive shaft as an attachment: For the position of the drive shaft see

'Dimensions and weight' With actuator as an attachment: The actuator is attached to the second blade from the top Construction and materials comply with the EU directive and guidelines for use in potentially explosive atmospheres (ATEX) for variants with brass or stainless steel bearings (-M, -E) Materials and surfaces Casing and blades made of galvanised sheet steel or stainless steel Blade shafts, drive arm and external linkage made of galvanised steel or stainless steel Plastic, brass or stainless steel bearings P1: Powder-coated, RAL CLASSIC colour PS: Powder-coated, DB colour Standards and guidelines Casing air leakage to EN 1751, class C Maintenance Maintenance-free as construction and materials are not subject to wear Contamination should be removed as it may lead to corrosion and to increased closed blade air leakage TECHNICAL INFORMATION Function, Technical data, QUICK SIZING, Specification text, Order code, Related products Variants, Attachments, Dimensions and weight, Product details Installation details, Basic information and nomenclature Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-12-30 TROX Malaysia Sdn Bhd.

TROX MALAYSIA SDN. BHD. Online-Services Service-Hotlines Your contact partner Online fault report Locations Malaysia Main Office and Factory Number Tel: +60 6 678 8188 Fax: +60 6 678 8288 / 388 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Malaysia Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-12-30 TROX Malaysia Sdn Bhd.