Actuator for mixing valves 0262EN March 2016

Similar documents
Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0483EN October 2013 Metering units for sanitary or service water

HERZ Motorised Actuator

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Pressure Independent Control Valve

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

COMPONENTS FOR SOLAR THERMAL SYSTEMS

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

Components for central heating

ELECTRIC ACTUATORS 400 N

Harmony Installation, Operation and Maintenance

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

EMO TM. Actuators High performance proportional actuator For modulating control

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

ML6420A/ML6425A,B. Electric Linear Valve Actuators

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

NV Direct Coupled Globe Valve Actuator

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Electronic Circuit Breaker ESS20-0..

Pushing 1) force. Motor Spring [N] [kg]

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Modulating control valve PN16 with magnetic actuator

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

22C, 22CX, 22CX5, 26LC Series

VA-7450 Series. Electric Valve Actuators

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

Modulating control valve PN16 with magnetic actuator

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

2-position electric actuators with Ball valves VBZ ½...11/4

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Actuator ID10. Product Data Sheet Feature

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

M100F Incremental Motor Actuator R81F Interface Board

MS Application. Features. Proportional Valve Actuator General Instructions

Electrak Vdc - load up to 250 lbf. Performance Specifications. Standard Features and Benefits. General Specifications. Compatible Controls

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

VA-7000 SERIES ACTUATOR

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

SAV Electronic Valve Actuator

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Electro-hydraulic actuators for valves

AXS 215S: Continuous actuator for unit valves, with stroke indicator

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

VA-715x Electric Valve Actuator

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

ESBE Series 90 Electronic Motor Actuator (Combined with ESBE 3&4-Way Rotary Valves)

Heating Cost Allocation Valve with local acquisition of the flow temperature

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Control solutions Biofloor

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Front panel valves SV

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Digital Room Thermostats with Touch Screen LCD

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

Flow Meter Terminal Boxes

AV-8020 Series Floating Control Actuated Valve

Actuators for modulating control AME 110 NL, AME 120 NL

VPA Series and VAP Actuator

EL5600 Series Electric Actuators for DN15 to DN100 Valves

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

Space-saving installation Flexible motor mounting

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

AKM 105, 115: Rotary actuator for ball valve

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

LF Series Spring Return Direct Coupled Actuator

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Actuators for small valves

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

SAX Electronic Valve Actuator

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Electronic Globe Valves

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

AEL6 Series Smart Electric Actuators for DN15 to DN100 Control Valves

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

TW...series ball valve Wisdom series DN15~DN50 Female threaded connection for PN25 DN40~DN150 Flanged connection for PN16/PN25

Transcription:

06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe for delivery water temperature with bulb, length 7 mm and Ø 6 mm, connected to the actuator body. Proportional-integral (PI) digital electronic regulator inserted in the actuator body. Motorized manual control (open ring) of the valve by selecting the opening position (from 0% to 00%). Stand-alone functioning: manual selection by summer/winter mode selector. Stand-alone functioning: manual selection of the working set by rotating potentiometer with double adjustment scale. Winter mode from 0 C to 60 C; summer mode from 5 C to 5 C. K8X00 Description K8X00 is an actuator that works both as motor and regulator, to control the delivery temperature with three way mixing valve. The actuator can be used on three way valves: it controls fixed delivery temperature both heating and cooling, in stand-alone functioning; Versions and product codes Product code Supply Type Valve connection Delivery temperature probe Multipole cable for electric connections Frontal side and frontal panel of the actuator K8X00 Vac -point floating M8 x,5 mm Ring fixing to valve body Technical data Type of actuator: -point floating Power supply: V 50/60 Hz Type of command: automatic only Propulsion force: 0 N ±0 % Maximum stroke: 6,5 mm Opening time at maximum speed: 85 sec Electricity absorption: 5 VA Protection class: IP0 Storage temperature range: - 55 C with R.H non-condensing Operating ambient temperature range: 0 55 C with R.H non-condensing Electric cable length:,5 m (7 x 0, mm ) Ring nut for fixing to valve body: M8x,5 mm, in brass Delivery temperature probe: NTC sensor 0 kω at 5 C, sensor bulb 7 mm long, external Ø 6 mm x0, mm cable,,5 m long, external Ø = mm, Black external sheath, self-extinguishing Dual color LED (green/red), function status indicator Color: white/grey Control elements winter summer SUMMER/WINTER mode selector RED/GREEN signalling led 0 C 5 C 0 C 0 C 60 C 5 C Rotating potentiometer with double adjustment scale The summer/winter mode selector and the rotating potentiometer with double adjustment scale to select the fixed set for the delivery temperature control are on the frontal side of K8 actuator. Once summer/winter switching has been made through selector, position the rotating potentiometer at the desired set according to the appropriate graduated scale: the scale working during the winter is indicated with red numbers (range from 0 C to 60 C ascending clockwise); the scale working during the summer is indicated with blue numbers (range from 5 C to 5 C ascending anticlockwise). In stand-alone functioning of K8 actuator, after summer/winter switching through selector, position the rotating potentiometer at the desired set according to the appropriate graduated scale.

06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Signalling elements The led on the frontal side of actuator provides status information. Fixed red: indicates stand-alone functioning in WINTER mode. Fixed green: indicates stand-alone functioning in SUMMER mode. Electrical connection Addressing 6 7 8 6 7 8 K8X00 Conductor colour BROWN (marrone) GRAY (grigio) DELIVERY TEMP. SENSOR SHUTOFF SHUTOFF PINK V BROWN GRAY BUS RT+ RT- Com V YELLOW GREEN WHITE BLU V 50/60 Hz 5VA Function V~ supply connection V~ supply connection When V supply is activated to K8 actuator, the integrated electronic regulator starts a cycle of adjustment in which the stem of the actuator is led to complete by-pass position (the whole stem has gone back in the actuator body). Connection to bus The connection to the Bus conductor is compatible only with the Giacoklima thermoregulation (KPM0 regulator and accessories) Before connecting K8 actuator, make sure that network tension IS NOT CONNECTED and that it corresponds to the one written on the back of the device ( V~). The device must be installed by qualified staff only. Conductor color YELLOW (giallo) GREEN (verde) WHITE (bianco) BLUE (blu) Function RT+ Signal (RS85 standard) RT- Signal (RS85 standard) Com Common (signal + supply) V SELV supply Jumper for manual control (open ring) of the actuator 8 way microswitch for actuator addressing The addressing through microswitch with several ways is not relevant when K8 actuator is used as single device (stand-alone configuration): it is not necessary to make any configuration in this application. All microswitch sliders are positioned on OFF (side with -8 numbers) on delivery. K8 actuator uses selectors from to 6 to assign an address between 0 and : check the address to assign on the design documentation of the system. Position of microswitch ways Addr. 5 6 0 OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF 5 ON OFF ON OFF OFF OFF 6 OFF ON ON OFF OFF OFF 7 ON ON ON OFF OFF OFF 8 OFF OFF OFF ON OFF OFF 9 ON OFF OFF ON OFF OFF 0 OFF ON OFF ON OFF OFF ON ON OFF ON OFF OFF OFF OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF ON ON ON OFF OFF 5 ON ON ON ON OFF OFF 6 OFF OFF OFF OFF ON OFF 7 ON OFF OFF OFF ON OFF 8 OFF ON OFF OFF ON OFF 9 ON ON OFF OFF ON OFF 0 OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF ON OFF ON ON ON OFF ON OFF OFF OFF OFF ON ON OFF 5 ON OFF OFF ON ON OFF 6 OFF ON OFF ON ON OFF 7 ON ON OFF ON ON OFF 8 OFF OFF ON ON ON OFF 9 ON OFF ON ON ON OFF 0 OFF ON ON ON ON OFF ON ON ON ON ON OFF Make sure that the assigned address is correct: it is not possible to have two devices with the same address in the same system.

06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Motorized manual control of the valve 6 7 8 Jumper for manual control (open ring) of the actuator 8 way microswitch for actuator addressing The manual positioning (open ring) of the mixing valve is useful when starting a system or in order to check the functioning. This operation can be made with K8 actuator by extracting the apposite jumper on the board, after removing the upper shell: the rotating potentiometer position represents the required opening for the mixing valve in this manual state of functioning. The opening of the direct way from the boiler of the valve increases by rotating the potentiometer clockwise when Giacomini mixing valves are used. The stem of the actuator is completely retracted (0%) and the mixing valve closes the direct way completely (by-pass position), when the rotating potentiometer is completely rotated anticlockwise; the stem of the actuator is protruding (00%) and the mixing valve opens the direct way completely, when potentiometer is completely rotated clockwise. For the manual positioning: ) Remove V~ supply to K8 actuator. ) Loosen the actuator ring fixing to valve body and unscrew the actuator completely. ) Remove the upper shell of the actuator by removing the fixing screws. ) Extract the jumper placed on the electronic board as shown in the picture. 5) Position the upper shell of the actuator again through the fixing screws. 6) Assemble K8X00 actuator on the valve body again. 7) Activate V~ supply. The actuator resets completely until it closes the direct way completely (0%). The actuator positions at the indicated opening through the rotating potentiometer. When the functioning test is finished, follow the instructions and insert the jumper placed on the electronic board. Warining. Manual positioning tests of the valve must be carried out once the jumper on the electronic board has been extracted and after assembling again and fixing with the apposite screws the upper shell of the actuator. Do not activate V~ supply before assembling the upper shell again. The manual positioning of the valve must be carried out by qualified staff only. 6 7 8 Installation ) Unscrew the handwheel protecting body before assembling and adjust the shutter manually on R98 or R98N valve. ) Fix K8X00 actuator through its apposite brass fixing ring: the ring must be screwed to the valve body up to end stroke in order to ensure max. stroke to the shutter. ) Insert the immersion probe in a R7 pit, downstream of the secondary circulator, and block by means of the fixing screw. Positions of the linear stem of the actuator The action of the digital regulator integrated in K8X00 actuator associates the stem completely retracted to the position of complete closure (0%) as shown in the picture; the stem completely protruding from the actuator body is associated to the position of complete opening (00%). Stelo ritratto, posizione di by-pass della valvola miscelatrice R98 Correct installation positions of K8 actuator Dimensions Stelo sporgente, posizione di apertura della via diretta della valvola miscelatrice R98 A Warining. The reading of immersion delivery temperature probe is not taken into account during the manual positioning test of the valve. Make sure that the delivery temperature is not over or under the safety limits according to the kind of system. The manual positioning of the valve must be carried out by qualified staff only. M8x,5 mm B C Codice A [mm] B [mm] C [mm] K8X00 70 78 8 Reference standards CE marked EMC 00/08/CE Low voltage directive 006/95/CE

06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Additional information For additional information please check the website www.giacomini.com or contact the technical service: ' +9 0 97 6 +9 0 955 * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.A. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.A. Via per Alzo, 9-807 San Maurizio d Opaglio (NO) Italy

085EN March 06 07U578 -point floating actuator (connection M0 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M0x,5 mm brass ring fixing to valve body. Immersion probe for delivery water temperature with bulb, length 7 mm and Ø 6 mm, connected to the actuator body. Proportional-integral (PI) digital electronic regulator inserted in the actuator body. Motorized manual control (open ring) of the valve by selecting the opening position (from 0% to 00%). Stand-alone functioning: manual selection by summer/winter mode selector. Stand-alone functioning: manual selection of the working set by rotating potentiometer with double adjustment scale. Winter mode from 0 C to 60 C; summer mode from 5 C to 5 C. K8X0 Description K8X0 is an actuator that works both as motor and regulator, to control the delivery temperature with three way mixing valve. The actuator can be used on three way valves: it controls fixed delivery temperature both heating and cooling, in stand-alone functioning; Versions and product codes Product code Supply Type Valve connection Delivery temperature probe Multipole cable for electric connections Frontal side and frontal panel of the actuator K8X0 Vac -point floating M0 x,5 mm Ring fixing to valve body Technical data Type of actuator: -point floating Power supply: V 50/60 Hz Type of command: automatic only Propulsion force: 0 N ±0 % Maximum stroke: 6,5 mm Opening time at maximum speed: 85 sec Electricity absorption: 5 VA Protection class: IP0 Storage temperature range: - 55 C with R.H non-condensing Operating ambient temperature range: 0 55 C with R.H non-condensing Electric cable length:,5 m (7 x 0, mm ) Ring nut for fixing to valve body: M0x,5 mm, in brass Delivery temperature probe: NTC sensor 0 kω at 5 C, sensor bulb 7 mm long, external Ø 6 mm x0, mm cable,,5 m long, external Ø = mm, Black external sheath, self-extinguishing Dual color LED (green/red), function status indicator Color: white/grey Control elements winter summer SUMMER/WINTER mode selector RED/GREEN signalling led 0 C 5 C 0 C 0 C 60 C 5 C Rotating potentiometer with double adjustment scale The summer/winter mode selector and the rotating potentiometer with double adjustment scale to select the fixed set for the delivery temperature control are on the frontal side of K8 actuator. Once summer/winter switching has been made through selector, position the rotating potentiometer at the desired set according to the appropriate graduated scale: the scale working during the winter is indicated with red numbers (range from 0 C to 60 C ascending clockwise); the scale working during the summer is indicated with blue numbers (range from 5 C to 5 C ascending anticlockwise). In stand-alone functioning of K8 actuator, after summer/winter switching through selector, position the rotating potentiometer at the desired set according to the appropriate graduated scale.

085EN March 06 07U578 -point floating actuator (connection M0 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Signalling elements The led on the frontal side of actuator provides status information. Fixed red: indicates stand-alone functioning in WINTER mode. Fixed green: indicates stand-alone functioning in SUMMER mode. Electrical connection Addressing 6 7 8 6 7 8 K8 Conductor colour BROWN (marrone) GRAY (grigio) DELIVERY TEMP. SENSOR SHUTOFF SHUTOFF PINK V BROWN GRAY BUS RT+ RT- Com V YELLOW GREEN WHITE BLU V 50/60 Hz 5VA Function V~ supply connection V~ supply connection When V supply is activated to K8 actuator, the integrated electronic regulator starts a cycle of adjustment in which the stem of the actuator is led to complete by-pass position (the whole stem has gone back in the actuator body). Connection to bus The connection to the Bus conductor is compatible only with the Giacoklima thermoregulation (KPM0 regulator and accessories) Before connecting K8 actuator, make sure that network tension IS NOT CONNECTED and that it corresponds to the one written on the back of the device ( V~). The device must be installed by qualified staff only. Conductor color YELLOW (giallo) GREEN (verde) WHITE (bianco) BLUE (blu) Function RT+ Signal (RS85 standard) RT- Signal (RS85 standard) Com Common (signal + supply) V SELV supply Jumper for manual control (open ring) of the actuator 8 way microswitch for actuator addressing The addressing through microswitch with several ways is not relevant when K8 actuator is used as single device (stand-alone configuration): it is not necessary to make any configuration in this application. All microswitch sliders are positioned on OFF (side with -8 numbers) on delivery. K8 actuator uses selectors from to 6 to assign an address between 0 and : check the address to assign on the design documentation of the system. Position of microswitch ways Addr. 5 6 0 OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF 5 ON OFF ON OFF OFF OFF 6 OFF ON ON OFF OFF OFF 7 ON ON ON OFF OFF OFF 8 OFF OFF OFF ON OFF OFF 9 ON OFF OFF ON OFF OFF 0 OFF ON OFF ON OFF OFF ON ON OFF ON OFF OFF OFF OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF ON ON ON OFF OFF 5 ON ON ON ON OFF OFF 6 OFF OFF OFF OFF ON OFF 7 ON OFF OFF OFF ON OFF 8 OFF ON OFF OFF ON OFF 9 ON ON OFF OFF ON OFF 0 OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF ON OFF ON ON ON OFF ON OFF OFF OFF OFF ON ON OFF 5 ON OFF OFF ON ON OFF 6 OFF ON OFF ON ON OFF 7 ON ON OFF ON ON OFF 8 OFF OFF ON ON ON OFF 9 ON OFF ON ON ON OFF 0 OFF ON ON ON ON OFF ON ON ON ON ON OFF Make sure that the assigned address is correct: it is not possible to have two devices with the same address in the same system.

085EN March 06 07U578 -point floating actuator (connection M0 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Motorized manual control of the valve 6 7 8 Jumper for manual control (open ring) of the actuator 8 way microswitch for actuator addressing The manual positioning (open ring) of the mixing valve is useful when starting a system or in order to check the functioning. This operation can be made with K8 actuator by extracting the apposite jumper on the board, after removing the upper shell: the rotating potentiometer position represents the required opening for the mixing valve in this manual state of functioning. The opening of the direct way from the boiler of the valve increases by rotating the potentiometer clockwise when Giacomini mixing valves are used. The stem of the actuator is completely retracted (0%) and the mixing valve closes the direct way completely (by-pass position), when the rotating potentiometer is completely rotated anticlockwise; the stem of the actuator is protruding (00%) and the mixing valve opens the direct way completely, when potentiometer is completely rotated clockwise. For the manual positioning: ) Remove V~ supply to K8 actuator. ) Loosen the actuator ring fixing to valve body and unscrew the actuator completely. ) Remove the upper shell of the actuator by removing the fixing screws. ) Extract the jumper placed on the electronic board as shown in the picture. 5) Position the upper shell of the actuator again through the fixing screws. 6) Assemble K8X0 actuator on the valve body again. 7) Activate V~ supply. The actuator resets completely until it closes the direct way completely (0%). The actuator positions at the indicated opening through the rotating potentiometer. When the functioning test is finished, follow the instructions and insert the jumper placed on the electronic board. Warining. Manual positioning tests of the valve must be carried out once the jumper on the electronic board has been extracted and after assembling again and fixing with the apposite screws the upper shell of the actuator. Do not activate V~ supply before assembling the upper shell again. The manual positioning of the valve must be carried out by qualified staff only. 6 7 8 Installation ) Unscrew the handwheel protecting body before assembling and adjust the shutter manually on R98 or R98N valve. ) Fix K8X0 actuator through its apposite brass fixing ring: the ring must be screwed to the valve body up to end stroke in order to ensure max. stroke to the shutter. ) Insert the immersion probe in a R7 pit, downstream of the secondary circulator, and block by means of the fixing screw. Positions of the linear stem of the actuator The action of the digital regulator integrated in K8X0 actuator associates the stem completely retracted to the position of complete closure (0%) as shown in the picture; the stem completely protruding from the actuator body is associated to the position of complete opening (00%). Stelo ritratto, posizione di by-pass della valvola miscelatrice R98 Correct installation positions of K8 actuator Dimensions Stelo sporgente, posizione di apertura della via diretta della valvola miscelatrice R98 A Warining. The reading of immersion delivery temperature probe is not taken into account during the manual positioning test of the valve. Make sure that the delivery temperature is not over or under the safety limits according to the kind of system. The manual positioning of the valve must be carried out by qualified staff only. M0x,5 mm B C Codice A [mm] B [mm] C [mm] K8X0 70 78 8 Reference standards CE marked EMC 00/08/CE Low voltage directive 006/95/CE

085EN March 06 07U578 -point floating actuator (connection M0 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Additional information For additional information please check the website www.giacomini.com or contact the technical service: ' +9 0 97 6 +9 0 955 * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.A. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.A. Via per Alzo, 9-807 San Maurizio d Opaglio (NO) Italy