Suction Guide & Flo-Trex Valve Series

Similar documents
Series SG & FTV. Suction Guides & Flo-Trex Valves

GROOVED END FLO-TREX COMBINATION VALVE

CBV Series. Circuit Balancing Valves

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

Suction Guides. Installation and operating instructions

FTV-S (Straight) & FTV-A (Angle Body) Tri-Service Valve

DATA BOOKLET LSD SERIES. Suction Diffusers. Pumps Motors ISO 9001 Company. Catalogue Pumping Solution

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Series 40MF. End Suction Fire Pumps & Packaged Systems

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

AIR/VACUUM VALVE AND OPTIONAL ANTI-SLAM DEVICE SPECIFICATION

Suction Diffuser - Iron Body Style PSD 125# Flanged 2 x 1-1/2 thru 20 x Technical Data...3

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

INSTALLATION AND OPERATING INSTRUCTIONS Tri-Service Valve. FTV-A Angle Pattern FTV-S Straight Pattern

Valve Selection. 1. Function and service considerations

Series 4600F. HSC Fire Pumps & Packaged Systems

Crispin Valves Operating Guide. Crispin

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Valves & Flow Control Components Valves & Flow Control Components

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

PRESSURE REDUCING CONTROL VALVE

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Titan Check Valves. Call. Fax. . Visit. Titan Flow Control. Your Pipeline to the Future

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Installed on the pump suction, CRISPIN Foot Valves prevent the

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

PRESSURE REDUCING VALVE

FIRE PUMPS & PACKAGED

SECTION VALVES

CUSTOM COMBINATION AIR VALVE

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

CE Close-Coupled End Suction Pumps. Leading The Flow. TACO.

Suggested Specifications

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

SECTION HVAC WATER PIPING ACCESSORIES

Mueller Super Centurion 250 Fire Hydrant

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

The SC Series Surge Check Valves Sizes 3 thru 24 Available Cast Iron Construction Limits the Effects of System Surge on Air Release Valves.

A. Valves and specialties including necessary accessories indicated on drawings and specified in this section.

MODEL 106-PT / 106-PTC / S106-PT / S106-PTC DOUBLE CHAMBER HYDRAULICALLY OPERATED VALVE

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

SECTION VALVES PART 1 -GENERAL

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Wafer Silent Check Valves

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

MODULATING FLOAT CONTROL VALVE

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

NECO Pumping Systems

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Parts List. Item # Part # # Reqd. Description

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

PRESSURE REDUCING CONTROL VALVES

FLOAT CONTROL VALVES

GBV-G Balancing Valves

Page ATALOGUE. Web: Tel: Fax:

See our expanding selection of products on Product Portfolio

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

Patent Pending. High Performance Self-Priming. Centrifugal Trash Pumps.

Cast-Iron Valves G101 DI BUTTERFLY VALVE LEVER... 2 G401 CI GLOBE VALVE CL G403 CI GLOBE VALVE PN G103 DI BUTTERFLY VALVE GEAR...

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

BERMAD Fire Protection

15100 VALVES. E. Section Building Automation and Control System Guidelines

PACIFIC. for Agricultural Irrigation Applications. exceptional quality unparalleled performance

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

See our expanding selection of products on Product Portfolio

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Iron Check Valves Illustrated Index

FE Frame-Mounted End Suction Pumps. Leading The Flow. TACO.

SECTION MISCELLANEOUS VALVES

Section M Dry Pipe Systems

The Universal Sewer Air Release Valve is designed to permit

HYDRAULIC CONTROL VALVES

Henderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS

Division 23 - HVAC Section Switzerland Beallsville K-12 GENERAL DUTY VALVES FOR HVAC PIPING

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems.

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Index. Butterfly Valves

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

FI / SFI Frame-Mounted End Suction Pumps

Standard-Low Emission Valves to 100 PPM. A-Series Brass Appliance Valves CSA Approved; 1 & 2 piece Body Designs; Threaded & Flare End connections

Transcription:

Suction Guide & Flo-Trex Valve Series Pump Trim FILE NO: 6-1 DATE: August 2010 SUPERSEDES: 6-1 DATE: July 200

Series SG & FTV Suction Guides Designed for direct mounting on the suction flange of horizontal and vertical pumps. Armstrong Suction Guide Design: Model SG: Model SGG: Model SGHH: Supplied with cast iron body and 125 psig/pn16 flanges. Supplied with ductile iron body with grooved inlet connection and 125 psig/pn16 outlet flange. Supplied with ductile iron body and 250 psig/pn25 flanges. 90 Elbow Mounting the Suction Guide on any pump suction turns the piping 90, replacing an elbow. In addition, the Suction Guide can be rotated to any position allowed by the pump suction bolts, from vertical to horizontal. In-Line Strainer The stainless steel strainer has free area of at least 250% of pipe sectional area. A disposable fine-mesh strainer is installed for start-up cleaning. Reducing Elbow The Suction Guide connects same size piping to the pump suction, but can also connect to inlet piping one size larger than the pump suction, eliminating a reducing elbow. Guide Vanes Flow stabilizing vanes on the outlet allow the Suction Guide to bolt directly to the pump, saving the space and cost of a long straight pipe length. 2

Suction Guides and Flo-Trex Valves Armstrong Model FTV Flo-Trex combination valves combine the features of a check valve, throttling valve, and a shut-off valve, and are designed for installation on the discharge side of centrifugal pumps. The convertible body design permits the valve to be changed on site from the straight to the angle configuration. Armstrong Model FTV Flo-Trex Valve Design: Model FTV-F: Model FTV-G: Drip-tight Shut Off Valve Flo-Trex valve is supplied with hard (cast-in) flanges. Flo-Trex valve is supplied with grooved port connections, designed for Armstrong Armgrip TM flange adapters or standard grooved pipe fittings. The Armstrong Flo-Trex valve is designed and tested for drip-tight isolation at 150% of maximum working pressure. Non-slam Check Valve The Armstrong Flo-Trex valve incorporates a spring closure design that closes the valve in a controlled manner, protecting the valve from slamming due to a reversal in flow caused by gravity or re-circulation from a parallel pump. Flow Throttling Valve The Armstrong Flo-Trex valve uses a plug and disc design which is the most effective valve type for combining throttling of flow and isolation. Other design valves may be effective for throttling or isolation, but not both. Convertible Body Design The Armstrong Flo-Trex convertible body design permits the valve to be changed on-site from straight to angle configuration. 3

Suction Guides and Flo-Trex Valves Fewer components required as redundant fittings are eliminated Fewer connections required with Armstrong's multipurpose fittings Less installation time required by reducing the number of fittings Less installation space required as pump inlet spool piece is eliminated The Smart Choice An Armstrong Vertical In-Line Pump installation requires the fewest components and connections, maximizing savings and minimizing installation time. Armstrong Method Base Mounted Single Suction Pump Flo-Trex Combination Valve Suction Guide with Strainer Flo-Trex Combination Valve Suction Guide with Strainer Base Mounted Double Suction Pump Suction Guide with Strainer Flo-Trex Combination Valve Vertical In-Line Pump 4

Conventional Method 1 5 4 Components eliminated using Armstrong Flo-Trex Valves and Suction Guide strainer for base mounted single and double suction pump installations and Vertical In-Line installations: 1. Y Strainer 2. Suction long radius elbow 2 6 Base Mounted Single Suction Pump 8 5 3. Discharge long radius elbow 4. Discharge check valve 5. Discharge globe valve 6. Suction spool piece In addition, use of the FTV-G style eliminates three welded flange connections. 1 4 2 6 8 3 Base Mounted Double Suction Pump 5 Additional components eliminated using Armstrong Vertical In-Line pumps with Flo-Trex Valves and Suction Guide strainers in place of base mounted applications: 1 4. Flexible connectors 8. Inertia base isolation 9. Field shaft alignment (not shown) 2 6 3 Vertical In-Line Pump 5

Materials of Construction Suction Guides Strainer Fine-Mesh Model Body Cover 3 mm ( 1 /8 ) (Start-Up) Perforations Strainer SG SGHH Guide Vanes Cast Ductile Stainless Galvanized Cast Iron Iron Steel Steel Iron Ductile Ductile Stainless Galvanized Ductile Iron Iron Steel Steel Iron Suction Guide Body Cast iron, or ductile iron, with PN16 or PN25 flanges. Same size ports are available with oversized inlet flange to eliminate reducer. Guide Vanes Stabilizing vanes reduce turbulence, thereby creating optimum flow conditions and minimizing stress on pump components. Strainer 3mm ( 1 /8 ) perforated stainless steel, star-shaped for added strength, designed to provide large free flow area to reduce pressure drop. Maximum Operating Parameters Flo-Trex Valves Model Body Disc Suction Guide & Flo-Trex Pressure/Temperature Parameters (2.6) 400 Stem & Seat & Port Spring O-Ring Fittings FTV-F 125 Cast Bronze Stainless EPDM Brass PN16 Iron Steel FTV-F 250 Ductile Bronze Stainless EPDM Brass PN25 Iron Steel FTV-G Ductile Bronze Stainless EPDM Brass PN25 Iron Steel Model SG Suction Guide Start-up strainer Removable fine mesh strainer, furnished as a standard item, helps prevent mechanical seal or instrument damage during initial run period. Optional magnet to help eliminate free floating metallic particles from system. Removable cover, with O-ring, enables easy access to strainer. Pressure - psig (bars) (20.) 300 (13.8) 200 (6.9) 100 SGHH 250#/PN25 flanges FTV-F 250#/PN25 flanges FTV-G 250#/PN25 flange adapter SG, SGG 125#/PN16 flanges FTV-F 125#/PN16 flanges FTV-G 125#/PN16 flange adapter VITON VITON (0.0) 0-50 0 50 100 150 200 250 300 (-45.6) (-1.8) (10.0) (3.8) (65.6) (93.3) (121.1) (148.9) Temperature - F ( C) 6 Note: For temperatures from 230 F to 300 F (110 C to 149 C) use Viton Elastomer.

Technical Information Design Benefits Reduced field installation and material costs. Cast iron or ductile valve body with hard flanges, or ductile iron valve body with standard grooved ends. Eliminates requirement for two separate valves on pump discharge and, in some cases, a 90 elbow. FTV-G eliminates three welded flange connections. Soft seat to ensure tight shut-off. Spring-closure design uses a non-slam silent check valve feature for vertical mounting. Flow measurement and pump throttling capabilities. Temperature measurement capability. Spring-closure design check valve prevents gravity or reverse circulation when pump is not operating. Bonnet O Ring can be replaced under full system pressure by back seating of valve stem. Suitable for maximum working pressure up to 35 psi (26 bars) and temperatures up to 110 C (230 F). Optional Viton elastomer for temperatures up to 150 C (300 F). Valve seat can be changed in the field without use of special tools. Low pressure drop due to Y pattern valve design. Flow Indicator Scale The valve stem, with its grooved rings and positioning sleeve, indicates the throttle position of the valve. The quarter turn graduations on the sleeve, with the scribed line on the stem, provide for approximate flow measurement. Hard Flanged Body or Armgrip TM Flange Adapter The hard flanged body or the combination of the Armstrong flange adapter and Flo-Trex body, equipped with the unique Armgrip TM anti-rotation lugs, ensures a rigid pump installation. Flow/Temperature Measurement Ports Drain Connection (on opposite side) Bonnet O Ring Stainless Steel Stem Resilient Seat Bronze Disc Model FTV-GA Flo-Trex Valve Armgrip TM Flange Adapter Armgrip TM Anti-rotation Lugs Flow Indicator Scale Stainless Steel Spring Seat Gasket Flow Indicator Scale Gasket

Typical Specification - Pump Trim Suction Guides Furnish and install on the suction of each pump an Armstrong Suction Guide, with Outlet Flow Stabilizing Guide Vanes, removable Stainless Steel Strainer and Fine Mesh Start-up Strainer. For 10 bar flanged pipe - Supply valve with Cast Iron body with PN16 flanged ports. For 20 bar flanged pipe - Supply valves with Ductile Iron body and PN25 flanged ports. The mechanical contractor shall inspect the strainer prior to activating the pump and, further, shall remove the Fine Mesh Start-up Strainer after a short running period (24 hours maximum). Space shall be provided for removal of the Strainer and connection of a blow-down valve. Flo-Trex Valves Furnish and install on the discharge side of each pump an Armstrong Model FTV Flo-Trex Combination Valve. Each valve is to incorporate the following three functions in one body: Tight shut-off, spring-closure type, silent non-slam check giving effective throttling with flow measurement capability. The body shall have (2) 1 /4 NPT connections on each side of the valve seat. Two connections to have brass pressure and temperature metering ports, with Nordel check valves and gasketed caps. Two other connections to be supplied with brass drain plugs. Metering ports are to be interchangeable with drain ports to allow for measurement flexibility when installed in tight locations. The valve disc shall be bronze plug & disc type with high impact engineered resin seat to ensure tight shut-off and silent check operation. The valve stem shall be stainless steel with flat surfaces provided for adjustment with open-end wrench. For Grooved Piping: Valve body shall be ductile iron with grooved ends and Armstrong anti-rotation Armgrip TM lugs on the inlet and outlet of the body. Flange adapters, where necessary, are to be Armstrong Armgrip TM PN16 or PN25 ductile iron flanges with anti-rotation lugs and EPT gaskets. For Welded Flange Piping: For 10 bar flanges - Valve body shall be Cast Iron with PN16 flanged ports. For 20 bar flanges - Valve body shall be Ductile Iron with PN25 flanged ports. The valve shall be selected and installed in accordance with the manufacturer s instructions and be suitable for the pressure and temperature specified. Insulation (Available for 2.5-6 Flo-Trex Valves) Each valve shall be furnished with a pre-formed removable PVC insulation jacket to meet ASTM D184 Class 14253-C, MEA #-8, ASTM-E-84 and ASTM136 with a flame spread rating of 25 or less and a smoke development rating of 50 or less. There will be provided sufficient mineral fibreglass insulation to meet ASHRAE 90.1-1989 specifications in operating conditions with maximum Fluid Design Operating Temperature Range of 60 C-93 C (141 F-200 F) and Mean Rating Temperature of 52 C (125 F). Our policy is one of continuous improvement and we reserve the right to alter our dimensions and specifications without notice Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 8444 145 145 F: +44 (0) 8444 145 146 S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: 001 416 55 2291 F: 001 416 59 9101 For Armstrong locations worldwide, please visit www.armstrongintegrated.com