LEVEL 2 DEFENSIVE Standard Equipment Guide

Similar documents
STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

Chapter Quiz. Directions: Write the correct letter on the blank before each question.

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations

Sunday, June 2, 13. Truck 6 Apparatus Familiarization Guide

Fire Engine Information

Basalt Fire-Rescue Engine 43 Inspection

UNIT CAD CLASSIFICATION DEFINITIONS. Northampton County Emergency Management Services

Fire Apparatus Operator: Mobile Water Supply. 9 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus. Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition)

Chapter 15. Fire Hose. Answer Key. Firefighter I

Driver/Operator Program Part III - Tanker

Position Number Community Division/Region Yellowknife North Slave

THE CO$T OF DOING BU$INE$$

AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply

Driver/Operator - Mobile Water Supply

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

CLEARWATER FIRE & RESCUE TRAINING BUREAU

Fire Fighting, Police, and Emergency Equipment 135

United Stales COMDPTPUB P Coast Guard NVIC Mar 191

Colorado Division of Fire Prevention & Control Driver Operator Aerial JPRs (NFPA 1002, 2014 Edition)

GRANDVIEW TOWNSHIP FIRE DEPARTMENT STANDARD OPERATING GUIDELINES. #333 Vehicle Fire Date Issued: 01/01/2014 Date Last Revised: 01/01/2014

ADDENDUM NO. ONE AIRCRAFT RESCUE AND FIRE FIGHTING AND AIRPORT OPERATIONAL SUPPORT SERVICES FOR THE TRENTON MERCER AIRPORT AB

EAST LAKE TARPON SPECIAL FIRE CONTROL DISTRICT E58 CHECKLIST (5-1-15) MONTH OF: YEAR: DATE:

Chapter Test. Directions: Write the correct letter on the blank before each question.

Rural Water Supply Operations Seminar & Drill

1500 GPM CAFS WASP Sheldon Fire & Rescue Houston, TX ESD 60 ESD 60. Darley September 25, 2015 PART NO DESCRIPTION QTY

ESSENTIAL SAFETY RESOURCES

CLEARWATER FIRE & RESCUE TRAINING BUREAU

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report

Essentials of Fire Fighting,

Apparatus Purchasing. Travis Ownby Sales Manager Siddons-Martin Emergency Group

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

West Metro Fire Protection District

20,000 $10,500 $10,500 Facilities $50,000 $10,000 TOTALS $165,000 $300,500 $385,500 $865,500 $86,000

ADO-Aerial Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

DARLEY APPARATUS AERIALS CHALLENGER CUSTOM BUILDS EZ SPEC PROGRAM

BETTER PERFORMANCE THROUGH BETTER IDEAS

Certification Guide Apparatus Equipped with Fire Pump

Apparatus Riding Assignments

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

The Apparatus Architect-Part 21. Designing Ladder Company Apparatus. In the last segment of the Apparatus Architect we discussed some of the

First Revision No. 1-NFPA [ Global Input ]

STANDARD OPERATING GUIDELINES

Commercial Traditional Engine 1250 GPM Side Mount Pump Rating 1200 Gallon - Stainless Body

EXAMPLE STANDARD OPERATING PROCEDURE EXPOSURE PREVENTION AND DECONTAMINATION

2.3.2 Hydrant Maintenance

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION

REGIONAL DISTRICT of OKANAGAN-SIMILKAMEEN REQUEST FOR QUOTATIONS Fire Truck Tulameen Fire Department February 2, 2016

PUMPERS CUSTOM AND COMMERCIAL. Discover Innovation. Experience Technology.

Procedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November January 2005

INSTRUCT-O-GRAM HOSE OPERATIONS THE HANDS ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XI, ISSUE 9 HOSE OPERATIONS SEPTEMBER 1990 INSTRUCTOR TASK

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

Other significant updates include:

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

The following is a list of guidelines that apply to all evolutions.

Apparatus Placement. Was this fire apparatus placed properly?

OCCUPATIONAL TOOL AND EQUIPMENT LIST

Fairview Fire District

Developed by Engineer Bobby Bartlett February 2012

KEY LARGO FIRE RESCUE AND EMS DISTRICT FY BUDGET DETAILS - FIRE DEPARTMENT

Fittings & Accessories

Scarborough Fire Department Scarborough, Maine Standard Operating Procedures

Sample Geographic Information System (GIS) Staffing and Response Time Report Virtual County Fire Department GIS Analysis

PUMPERS. Commercial and Custom

Ponderosa VFD Apparatus Driver Training

Rural Water Supply Operations Seminar & Drill

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

AccuMax 3060 Multi-Point Detailed Specifications

FAMA Statistics Website Instructions

PUMPERS. Built to work harder and longer at the scene.

AVIATION FACILITIES AND OPERATIONS

Driver Operator Aerials: Maintenance and Testing. 4 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Apparatus Replacement Policy

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

Measure South Lane County Fire & Rescue General Obligation Bond November 3, 2015

2015 Fire Department

VISION SERIES APPARATUS

JHT ACN COMPANY INDUCTION JOHN HEGGART TRANSPORT. Ph: Fax: P.O BOX 1271 Warragul Vic

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

NFPA 1964 November 2002 ROP Copyright, 2002 NFPA

Revision History. 1. PURPOSE To set forth minimum site requirements for the construction, use and maintenance of portable ladders.

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

Business Plan We will reflect the National Treasure in which we live

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

EMPLOYEE ORIENTATION SKILLS

BEAVER EMERGENCY SERVICES COMMISSION REGULATION

Our most versatile quick attack unit that combines technology with simplicity.

PURPOSE POLICY. Page 1 of 6 / S.O.G Highway Operations Pascal Arnes Chief of Fire

Shop Order : Unclassified

Standardization of Fire Apparatus

Tyger Drafting Eductors

Basalt Fire-Rescue Rescue 41 Inspection

Transcription:

LEVEL 2 DEFENSIVE Standard Guide

This guidance document was developed to assist NWT fire departments with identifying the minimum equipment required for a Standard - Level 2 Defensive fire service as defined in MACA s Community Fire Protection Matrix. It is recommended that community fire departments develop a program in accordance with NT safety legislation and recognized standards for the selection, care, and maintenance of protective firefighting ensembles, fire apparatus, and support equipment. The NFPA standards referenced in this document contain additional information for community fire departments looking to: 1) Establish minimum levels of protection for firefighting personnel; 2) Establish basic criteria for the selection of Protective Firefighting Ensembles; 3) Identify minimum requirements for an Initial Attack Fire Apparatus; 4) Identify the minimum requirements for a Pumper Fire Apparatus; 5) Identify minimum requirements for a Mobile Water Supply Apparatus. WSCC Firefighter Code of Practice 11.4 Personal Protective Based on the hazard assessment the employer must ensure that required personal protective equipment (PPE) is available, maintained, tested, and used. The employer must be able to demonstrate that acceptable protection levels for the hazards faced by their firefighters have been provided. The use of clothing and equipment that complies with NT safety legislation and standards issued by CSA, ANSI, NFPA or other recognized agencies should be identified in departmental purchasing policies and procedures. 11 All firefighters must be trained in the selection, pre-use inspection, use and limitations of all their equipment including PPE. 11.1 Inventions/Modifications All fire department pumper apparatus, water tanks, ladder trucks, aerial devices, mini-pumpers, special services firefighting vehicles and combinations of these must be designed and constructed in accordance with a commonly accepted firefighting industry standard which is in compliance with the Safety Act and OHS Regulations. Page 1 of 14

Coats Trousers Helmets Hoods Balaclavas Gloves Footwear Standard - Level 2 Defensive Firefighter Training includes training on firefighter turnout gear which consists of protective coats, trousers, helmets, hoods, balaclavas, gloves, and footwear. NFPA 1851 Standard for Selection, Care, and Maintenance of Protective Ensembles 1.1.2 Scope This standard specifies the selection of minimum firefighting protective ensembles that include garments, helmets, gloves, footwear, and interface components that are compliant with NFPA 1971. 4.1.1 General NFPA 1971 Standard on Protective Ensembles 1.1.2 Scope This standard specifies the minimum design, performance, testing, and certification requirements for firefighting protective ensembles. The organization shall develop and implement a program for the selection, care, and maintenance of protective firefighting ensembles used by members of the organization in the performance of their assigned functions. 4.1.2 This program shall have the goal of providing protective firefighting ensembles that are suitable and appropriate for the intended use. Page 2 of 14

Standard - Level 2 Defensive Firefighter Training includes knowledge & skills training utilizing various tools and equipment stored on a fire truck. The design specifications and equipment listing below is based on the NFPA 1901 standard for an initial attack fire apparatus. NFPA 1901 Standard for Automotive Fire Apparatus 1.1 Scope This standard defines the requirements for new automotive fire apparatus designed to be under emergency conditions to transport personnel and equipment. NFPA 1901 6.1 General If the apparatus is to function as an initial attack apparatus, it shall meet the requirements of this chapter. 6.8 Supplied by the Contractor The contractor shall supply the equipment listed in 6.8.1 and 6.8.2 and shall provide and install such brackets or compartments as are necessary to mount the equipment. Page 3 of 14

Subject Design Specifications NFPA 1901-05 Fire Pump Minimum rated capacity of 1000 L/min (250 gpm) 6.2 Foam Proportioning System If equipped, it shall meet the requirements of Chapter 20. 6.4 Water Tank Minimum certified capacity (combined, if applicable) of 750 L (200 gal) 6.5 Storage Minimum of 22 ft 3 (0.62 m 3 ) Enclosed and weather-resistant. *May need to consider room for a portable water tank (see Page 14).* 6.6 Hose Storage A minimum hose storage area of 10 ft 3 (0.8 m 3 ) for 2½ inch (65 mm) or larger fire hose. 6.7 Subject Ground Ladders Two areas, each a minimum of 3.5 ft 3 (0.1 m 3 ), to accommodate 1½ inch (38mm) or larger pre-connected fire house lines. A 12ft (3.7m) or longer combination or extension type ladder Step ladders and other types of multipurpose ladders are permitted NFPA 1901-05 6.8.1 Suction Hose Minimum of 20 ft (6 m) of suction hose or 15 ft (4.5 m) of supply hose. 6.8.2 Where suction hose is provided, a suction strainer shall be furnished. *May need to consider additional suction hose for nursing lines* Page 4 of 14

Fire Hose and Nozzles Miscellaneous 300 ft (90 m) of 2½ inch (65 mm) or larger fire hose 400 ft (120 m) of 1½ inch (38 mm), 1¾ in (45 mm), or 2 inch (52 mm) fire hose Two handline nozzles, 95 gpm (360 L/min) minimum One 6 lb (2.7 kg) pickhead axe One 6 ft (2 m) pike pole or plaster hook Two portable hand lights One approved dry chemical portable fire extinguisher with a minimum 80-B:C rating One 2½ gal (9.5 L) or larger water extinguisher * One SCBA for each assigned seating positing, but not fewer than two, mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer *One spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in specialty designed storage space(s) One first aid kit Two combination spanner wrenches One hydrant wrench One double female 2½ inch (65 mm) adapter with CSA threads One double male 2½ inch (65 mm) adapter with CSA threads One rubber mallet Two salvage covers each a minimum size of 12 ft x 14 ft (3.7 m x 4.3 m) Two or more wheel chocks One traffic vest for each seating position Five fluorescent orange traffic cones Five illuminated warning devices such as highway flares, unless the five fluorescent orange traffic cones have illuminating capabilities One automatic external defibrillator (AED) 6.9.3* 6.9.4* Page 5 of 14

*Please Note: 1) The equipment listed in 6.9.3 and 6.9.4 shall be available on the pumper fire apparatus before the apparatus is placed in service (NFPA 1901) 2) SCBA is included in this equipment list to be in compliance with section 6.9.4 of the NFPA 1901 standard. NWT community fire departments, who have not adopted a level of service which permits the use of SCBAs, shall not have them in-service or stored on the apparatus. Page 6 of 14

Standard - Level 2 Defensive Firefighter Training includes knowledge & skills training utilizing various tools and equipment stored on a fire truck. The design specifications and equipment listing below is based on the NFPA 1901 standard for a pumper fire apparatus. NFPA 1901 Standard for Automotive Fire Apparatus 1.2 Scope This standard defines the requirements for new automotive fire apparatus designed to be under emergency conditions to transport personnel and equipment. NFPA 1901 5.1 General If the apparatus is to function as a pumper, it shall meet the requirements of this chapter. 5.8 Supplied by the Contractor The contractor shall supply the equipment listed in 5.8.1 and 5.8.2 and shall provide and install such brackets or compartments as are necessary to mount the equipment. Page 7 of 14

Subject Design Specifications NFPA 1901-05 Fire Pump Minimum rated capacity of 3000 L/min (625 gpm) 5.2 Foam Proportioning System If equipped, it shall meet the requirements of Chapter 20. 5.4 Water Tank Minimum certified capacity (combined, if applicable) of 1100 L (250 gal) 5.5 Storage Minimum of 40 ft 3 (1.1 m 3 ) Enclosed and weather-resistant. *May need to consider room for a portable water tank (see Page 14).* 5.6 Hose Storage A minimum hose storage area of 30 ft 3 (0.8 m 3 ) for 2½ inch (65 mm) or larger fire hose. 5.7 Two areas, each a minimum of 3.5 ft 3 (0.1 m 3 ), to accommodate 1½ inch (38mm) or larger pre-connected fire house lines. Aerial Device If equipped, the device shall meet the requirements of Chapter 19, NFPA 1901. 5.3 Subject Ground Ladders One straight ladder equipped with roof hook One extension ladder One folding ladder NFPA 1901-05 5.8.1 Suction Hose Minimum of 20 ft (6 m) of suction hose or 15 ft (4.5 m) of supply hose. Where suction hose is provided, a suction strainer shall be furnished. *May need to consider additional suction hose for nursing lines.* 5.8.2 Page 8 of 14

Fire Hose and Nozzles 800 ft (240 m) of 2½ inch (65 mm) or larger fire hose 400 ft (120 m) of 1½ inch (38 mm), 1¾ in (45 mm), or 2 inch (52 mm) fire hose One handline nozzle, 165 gpm (750 L/min) minimum Two handline nozzles, 80 gpm (360 L/min) minimum One smoothbore or combination nozzle with 2½ inch shutoff that flows a mnimum 250 gpm. 5.9.3* Miscellaneous One 6 lb (2.7 kg) flathead axe One 6 lb (2.7 kg) pickhead axe One 6 ft (2 m) pike pole or plaster hook One 8 ft (2.4 m) or longer pike pole Two portable hand lights One approved dry chemical portable fire extinguisher with a minimum 80-B:C rating One 2½ gal (9.5 L) or larger fire extinguishers *One SCBA for each assigned seating positing, but not fewer than two, mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer *One spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in specialty designed storage space(s) One first aid kit Four combination spanner wrenches Two hydrant wrenches One double female 2½ inch (65 mm) adapter with CSA threads One double male 2½ inch (65 mm) adapter with CSA threads One rubber mallet Two salvage covers each a minimum size of 12 ft x 14 ft (3.7 m x 4.3 m) Two or more wheel chocks One traffic vest for each seating position 5.9.4* Page 9 of 14

Five fluorescent orange traffic cones Five illuminated warning devices such as highway flares, unless the five fluorescent orange traffic cones have illuminating capabilities One automatic external defibrillator (AED) *Please Note: 1) The equipment listed in 5.9.3 and 5.9.4 shall be available on the pumper fire apparatus before the apparatus is placed in service (NFPA 1901) 2) SCBA is included in this equipment list to be in compliance with section 5.9.4 of the NFPA 1901 standard. NWT community fire departments, who have not adopted a level of service which permits the use of SCBAs, shall not have them in-service or stored on the apparatus. Page 10 of 14

Standard - Level 2 Defensive Firefighter Training includes water supply training utilizing various tools and equipment stored on a water supply tanker. The design specifications and equipment listing below is based on the NFPA 1901 standard for a mobile water supply apparatus. NFPA 1901 Standard for Automotive Fire Apparatus 1.3 Scope This standard defines the requirements for new automotive fire apparatus designed to be under emergency conditions to transport personnel and equipment. NFPA 1901 7.1 General If the apparatus is to function as a mobile water supply apparatus, it shall meet the requirements of this chapter. 7.8 Supplied by the Contractor The contractor shall supply the equipment listed in 7.8.1 and 7.8.2 and shall provide and install such brackets or compartments as are necessary to mount the equipment. Page 11 of 14

Subject Design Specifications NFPA 1901-05 Fire Pump If equipped, the pump shall meet the requirements of Chapter 16. 7.2 Foam Proportioning System If equipped, it shall meet the requirements of Chapter 20. 7.4 Water Tank Water tank(s) shall meet the requirements of Chapter 18, NFPA1901, and have a minimum certified capacity of (combined, if applicable) of 1000 gal (4000 L). 7.5 Storage Minimum of 10 ft 3 (0.0.3 m 3 ) of enclosed weatherresistant compartmentation meeting the requirements of Section 15.1 shall be provided for the storage of equipment. *May need to consider room for a portable water tank (see Page 14).* 7.6 Hose Storage Hose bed area(s), compartments, or reels that comply with Section 15.1 shall be provided to accommodate a minimum hose storage area of 6 ft 3 (0.8 m 3 ) for 2½ inch (65 mm) or larger fire hose. 7.7 If the apparatus is equipped with a pump, storage for a minimum of 100 ft (30 m) of 1½ inch (38mm) or larger hose for a protection line shall be provided. Subject NFPA 1901-05 Suction Hose If equipped with a pump, the requirements in 7.9.1 through 7.9.3 shall apply. 7.8.2 A minimum of 20 ft (6 m) of suction hose or 15 ft (4.5 m) of supply hose shall be carried. Where supply hose is provided, it shall have couplings compatible with the local hydrant outlet connection (where applicable) and pump intake connection. Where suction hose is provided, a suction strainer shall be furnished. Page 12 of 14

Fire Hose and Nozzles 200 ft (60 m) of 2½ inch (65 mm) or larger fire hose If equipped with a fire pump, 100 ft (30 m) of 1½ inch (38 mm), 1¾ in (45 mm), or 2 inch (52 mm) fire hose; one handline nozzle, 95 gpm (360 L/min) minimum. 7.9.3* Miscellaneous Two portable hand lights One approved dry chemical portable fire extinguisher with a minimum 3A-40B:C rating One first aid kit Two combination spanner wrenches One hydrant wrench (where applicable) One double female 2½ inch (65 mm) adapter with CSA threads One double male 2½ inch (65 mm) adapter with CSA threads Two or more wheel chocks One traffic vest for each seating position Five fluorescent orange traffic cones Five illuminated warning devices such as highway flares, unless the five fluorescent orange traffic cones have illuminating capabilities One automatic external defibrillator (AED) 7.9.4* *Please Note: 1) The equipment listed in 7.9.3 and 7.9.4 shall be available on the pumper fire apparatus before the apparatus is placed in service (NFPA 1901) Page 13 of 14

Small communities in the NWT do not possess municipal infrastructure, such as hydrants, and are challenged with maintaining a sustainable water supply for firefighting. One option available to assist with this reality are tanker shuttles. This is accomplished through modification of existing community tankers to include a dump valve and the purchase of porta-tanks to support firefighting efforts. The concept is that a porta-tank is set up for the fire truck to draft from, while the tanker shuttles water back and forth from their filling site. This allows the tanker travel time while the port-tank provides us water supply for firefighting. This water delivery concept provides additional safety for firefighters and residents. The following demonstrates its application: Page 14 of 14