Electrical Box. Optional. Condensing Unit (Field Installed)

Similar documents
Insight ID5SL P/N _L NSF. Certified. Dairy / Delicatessen / Beverage

Insight IC6SL P/N _L NSF. Certified. Dairy / Delicatessen / Meat

Optional Condensate Pan. Electrical Box

Insight IC2SL P/N _J NSF. Certified. Dairy / Delicatessen / Meat

Optimal Shelf Life. Conventional Controls IP4NL. Low Pressure Backup Control CI/CO 8 20 F / 10 F 6.67 C / 12.2 C

Insight ID6SU P/N _K NSF IMPORTANT. Certified. Dairy / Delicatessen

Optional Condensate Pans

Insight IDD5SU P/N _L NSF IMPORTANT. Certified. Dairy / Delicatessen / Beverage with EcoVision Doors

Insight ID5SMI45 P/N _B NSF. Certified. Dairy / Delicatessen / Beverage

Insight IC4BM P/N _E NSF. Certifi ed. Dairy / Delicatessen / Meat / Produce

Insight IC4SL P/N _F NSF. Certifi ed. Dairy / Delicatessen / Beverage / Meat

Fan Speed Selector (when applicable)

Insight ID5SM P/N _K NSF. Certifi ed. Dairy / Delicatessen / Beverage

Insight ID5NL P/N _H NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight ID5NM P/N _J NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight IM1SL P/N _H NSF. Certifi ed. Meat. Insight standard field electrical connections are at the bottom of the merchandiser.

Insight IP1SL P/N _F NSF. Certifi ed. Bulk Produce. Insight standard field electrical connections are at the bottom of the merchandiser

Insight IDD5SV P/N _E NSF. Certifi ed. Dairy / Delicatessen / Beverage with EcoVision Doors

ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

C5NX-LE P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

M3X-GE. P/N _F NSF Certified P/N_ _F. Technical Data Sheet. March 2010 F E B E. Item Part # Description Wiring Item #

M5X-GE. P/N _E NSF Certified P/N_ _E. Technical Data Sheet. March Item Part # Description Wiring Item #

FL5NX-LEP P/N _F E D A D B D P/N_ _F. Technical Data Sheet. March Item Part # Description Wiring Item #

ESGMVS Technical Data Sheet

C2X-LEP. P/N _K NSF Certified F E P/N_ _K. Technical Data Sheet. April Item Part # Description Wiring Item #

ESBDHV Technical Data Sheet

ESBD P/N _D NSF. Certified G K B E G F H K A. Technical Data Sheet. April Spanish P/N Data sheet-elite-esbd

C2X-EP P/N _P NSF. Certified. Technical Data Sheet. April Spanish P/N

C2X-LEP P/N _R NSF. Certified. Technical Data Sheet. April Spanish P/N

C5X-EP P/N _L NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

CF5X P/N _J NSF. Certified. Technical Data Sheet. October Scan QR code to access product information on your mobile device.

C6X-LEP P/N _Q NSF. Certified. September Spanish P/N Technical Data Sheet

M5NX-EP P/N _J NSF. Certified. Technical Data Sheet. April Spanish P/N

C2NX-EP P/N _B NSF. Certified. Technical Data Sheet. April Spanish P/N

ESGM Technical Data Sheet

C2NX-XLP P/N _F NSF. Certified. Technical Data Sheet. April Spanish P/N

P2X-EP P/N _J NSF. Certified. Technical Data Sheet. April 2017

M5X-EP Technical Data Sheet

M4X-EP P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

B4X-E P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

D5X-EP Technical Data Sheet

C2X-LE P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. October Spanish P/N

ME5X-GP P/N _G NSF. Certified. Technical Data Sheet. April Spanish P/N

DD5X-ULP IMPORTANT. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

DDF5NX-L. Certified. Technical Data Sheet P/N _E NSF. January 2018 B A. Scan QR code to access product information on your. mobile device.

DD6X-ULP Technical Data Sheet

DD6NX-L Technical Data Sheet

D5X-E P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

P2X-E P/N _L NSF. Certified. Technical Data Sheet. October 2017

CW2UGE E G A D. Certified. Technical Data Sheet P/N _B NSF. November Item Part # Description Wiring Item #

DF5NX P/N _J NSF. Certified. Technical Data Sheet. January Scan QR code to access product information on your mobile device.

DD5X-LP. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

D5X-HEP P/N _P NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

DD6X-URE P/N _G NSF IMPORTANT. Certified. Technical Data Sheet. April Spanish P/N

D6NX-LEP P/N _Q NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

D6X-ULEP Technical Data Sheet

DD5NX-L. Certified. Technical Data Sheet P/N _H NSF. July Scan QR code to access product information on your mobile device.

DD5X-LR P/N _J NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

SMGV Technical Data Sheet

FL5NX-LEP P/N _L. Technical Data Sheet. April Spanish P/N Item Part # Description Wiring Item #

P4X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

SMGT Technical Data Sheet

P2X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

C2-LE P/N G. P/N _G NSF Certified. Technical Data Sheet. November 2009

RI4 P/N _G NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. November Serial Plate

C2-LGE P/N D. P/N _D NSF Certified. Technical Data Sheet. November 2009

PW-E. Certified. Technical Data Sheet P/N _E NSF. October 2016

PWW-E. Certified October Technical Data Sheet P/N _C NSF

CW2UGE Technical Data Sheet

M5 Technical Data Sheet

CW2EGE C E. Technical Data Sheet P/N _B NSF. Certified. November Item Part # Description Wiring Item #

LED FIXTURES AND POWER SUPPLY. (C) Power Supply (D)

Insight ID5SM-W U L US C P/N _B NSF. Certified LISTED. Dairy / Delicatessen / Beverage Water-coooled Self-Contained R290 (Propane)

D5RRI P/N B. NSF Certified. Technical Data Sheet. June 2006 P/N B. Item Part # Description Wiring Item #

D5RRIS. P/N B NSF Certified. Technical Data Sheet. June 2006 P/N A. Item Part # Description Wiring Item #

EQUIPMENT INFORMATION SHEET REFRIGERATION - MEDIUM TEMP. Link to PDF file

Elevated C2-LE P/N D. NSF Certified. Technical Data Sheet. February Note: Changed items have been underlined.

F2XLG Technical Data Sheet

C2-XGE P/N C. NSF Certified. Technical Data Sheet. February 2006

RMT with P/N _H NSF. INNOVATOR Doors or INNOVATOR III Doors. Certified. Technical Data Sheet. June 2015

M1-GEB Technical Data Sheet

CW2U-XGE. Technical Data Sheet P/N B. NSF Certified E G F A D C. April Note: Changed items have been underlined.

Electrical Box Power Cord

Double Curved Glass. Merchandisers NEBCH. (Modified Front for Impact) Data Sheet Set P/N A. June, 1998 LAMPS AND BALLASTS

Excel DD5X5FRW U L US C P/N _E UL EPH IMPORTANT. Certified LISTED. Dairy / Delicatessen Self-Contained R290 (Propane)

IMPACT 3-Pin Shelf Lamp LED Retrofit for Hussmann Cases Manufactured AFTER February 2001

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

O2.5UMAK-NRG O2.5UMAK-NRG. Multi-Deck Mobile Self-Contained Merchandiser 4', 6' & 8' Case (Meal Kit) SHIPPING WEIGHT GENERAL NOTES

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES:

Ambient Pastry Case Family

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OHP-NRG OHP-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Produce) SHIPPING WEIGHT Case Weight OHP-NRG ---

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

O5DMH-NRG O5DMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT

EXCEL. Medium Temp Display Case. Far More Energy Efficient. Greater Merchandising Capacity. Enabling excellence in food retailing.

Multi Purpose Dairy Produce Packaged Meats Self Contained Remote Island Endless Line - Ups 30 to 40 Deep 44 to 84 High

Self-Contained PRICE LIST. April

Product Specifications Sheets

Transcription:

Insight standard field electrical connections are at the top left of the merchandiser Field Electrical Connection Power Supply Electrical Box Optional Condensing Unit (Field Installed) Insight IDF5SM / Beverage Merchandiser Data Sheet NSF Certified Facade (Field Installed) October 2018 Coil* Fan* Optional Condensate Pan Thermoexpansion Valve* Canopy LED Lights Shelf LED Lights *Coils, fans and TXVs are modular with one per 3 or 4 foot section. ail LED Lights Portion of parts removed for clarity. 12 foot merchandiser shown. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. Performance Data Page 2 Product Data (AHI Statistics) Page 2 Cross Section Page 3 Plan View Page 4 Electrical Loads Page 5 Estimated Shipping eights Page 6 Shelf Options Page 6 eplacement Parts List Page 7 iring Diagrams Page 8 Computing efrigeration and Electrical Load Page 11 evision History Page 11 Data sheet-insight IDF5SM e reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. 2018 HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900.HUSSMANN.COM Spanish P/N 3006890

efrigeration Data 1 Unlit Shelves IDF5SM Application Optimal Shelf Life Dairy/Deli/ Convertible / Beverage/ Produce Meat Energy Comparison NSF Type 2 AHI 1200 Pegs Ambient 4 3 ating Point 5 Discharge Air F ( C) 32 (0) 31 (-0.55) 30 (-1.11) 30 (-1.11) 35 (1.66) Average Evaporator F ( C) 2 28 (-2.22) 27 (-2.77) 26 (-3.33) 26 (-3.33) 31 (-0.55) Parallel Btu/hr/ft (atts/m) 6 975 (938) 1075 (1034) 1245 (1197) 1190 (1144) 910 (875) Lit Shelves Conventional Btu/hr/ft (atts/m) 6 1065 (1024) 1170 (1125) 1355 (1303) 1300 (1250) 990 (952) Discharge Air F ( C) 31 (-0.55) 30 (-1.11) 29 (-1.66) N/A 34 (1.11) Average Evaporator F ( C) 2 27 (-2.77) 26 (-3.33) 25 (-3.88) N/A 30 (-1.11) Parallel Btu/hr/ft (atts/m) 6, 7 990 (952) 1090 (1048) 1260 (1214) N/A 920 (885) Conventional Btu/hr/ft (atts/m) 6, 7 1080 (1038) 1190 (1144) 1380 (1325) N/A 1005 (966) Fan Speed 8 IDF5SM6 (8.25 ) 1300 1500 1500 1300 1300 IDF5SM4, 8, 12 (8.25 ) 1300 1500 8 1500 8 1300 1300 Notes: 1. All data based on store temperature and humidity that does not exceed NSF Type 1 ambient conditions of 75 F and 55% relative humidity except where noted. 2. Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 3. Data for operation in NSF Type 2 ambient of 80 F and 55% relative humidity. 4. Hussmann Peg Shelves for Dairy/Deli applications only. 5. AHI 1200 ating Point for energy consumption comparison only. 6. Subtract 60 Btu/hr/ft (57.7 atts/m) for front glass (on applicable models). 7. Add 10 Btu/hr/ft (9.6 atts/m) per shelf row for LED shelf light fixtures. 8. Some lengths and/or applications require optional fan speed control kits applied by the Hussmann Product Configurator. Defrost Data Frequency (hours between defrost) 4 Offtime IDF5SM Time (minutes) 20 Electric or Gas Defrost ater 9 Not Available 8.1 lb/ft/day (12.1 kg/m) 9 (± 15% based on case configuration and product loading). Conventional Controls IDF5SM Low Pressure Backup Control CI/CO 10 20 F / 10 F 6.67 C / 12.2 C Indoor Unit Only, Pressure Defrost Termination 48 F (8.89 C) 10 Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge 11 IDF5SM 4 ft 5.4 lb 86.4 oz 2.45 kg 6 ft 4.5 lb 72 oz 2.04 kg 8 ft 7.4 lb 118.4 oz 3.36 kg 12 ft 8.8 lb 140.8 oz 3.99 kg 11 This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Product Data Gross efrigerated Volume 12 (Cu Ft/Ft) AHI Total Display Area 13 (Sq Ft/Ft) Shelf Area 14 (Sq Ft/Ft) 11.7 ft 3 /ft (1.09 m 3 /m) 4.27 ft 2 /ft (1.30 m 2 /m) 9.85 ft 2 /ft (3.00 m 2 /m) 12 AHI Gross efrigerated Volume: efrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 13 Computed using AHI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 14 Shelf surface area is composed of bottom deck plus standard shelf complement for this model: (4) rows of 22-in. shelves 2 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDF5SM Merchandiser Data Sheet

Insight Multideck Merchandiser, Standard Bottom, Standard Height Front, 5 Display Levels Insight IDF5SM Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Shelf complement shown as tested: Four rows of 22-in. shelves spaced equally between bottom display pan and interior top panel. IDF5SM Dimensions shown as in. and (mm). 43 5/8 (1108) 1 1/2 In. (38 mm) equired Air Gap Other optional kits (top piping and vent fans) add to the overall case height. 29 1/4 (743) 20 1/8 (511) A minimum 1 1 /2 in. clearance required to remove raceway cover 6 1 /2 in. for full access. See the Installation manual for instructions. 3 in. between back to back cases. LOAD LIMIT LINE 103 1/2 (2629) Shown with Ellipse Option and Bumper. 51 3/8 (1305) OPTIONAL AIL LIGHT 59 1/4 (1505) 84 (2133) 2 (51) 23 (584) 19 (483) 30 1/8 (765) FAN C O I L A L L ail light cannot be used with glass front option. OPTIONAL GLASS FONT 5 1/2 (140) 29 (737) 1/2 (13) 33 1/2 (851) 7 1/4 (184) 35 5/8 (905) 43 5/8 (1108) Glass front cannot be used with rail light option. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A..HUSSMANN.COM 3 of 11

Engineering Plan View IDF5SM Dimensions shown as in. and (mm). A D 1 1/2 Inch (38 mm) equired Air Gap 7 (178) 7 (178) 3 5/8 (92) 18 (457) B efrigeration Outlet 8 1/2 (216) C aste Outlet B efrigeration Outlet 29 (737) 33 1/2 (851) 35 5/8 (905) 43 5/8 (1108) ireway in Canopy Splashguard Field Electrical Connection at TOP of Case F G E FONT (12 Foot Model shown above) 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) (Each end and insulated partition adds 1 1 /2 in. (38 mm) to case line up.) 48 1 /8 (1222) 72 1 /4 (1835) 96 1 /4 (2445) 144 3 /8 (3668) Maximum O/S dimension of case back to front (includes bumper) 43 5 /8 (1108) 43 5 /8 (1108) 43 5 /8 (1108) 43 5 /8 (1108) Back of case to front of splashguard 35 5 /8 (905) 35 5 /8 (905) 35 5 /8 (905) 35 5 /8 (905) (B) Distance between edges of external legs and center legs NA 29 (737) 41 (1041) 41 (1041) (C) Distance between edges of center legs 41 1 /8 (1045) NA NA 41 1 /8 (1045) Distance between front legs and splashguard 8 (203) 8 (203) 8 (203) 8 (203) Electrical Service (Field Electrical iring Connection) (D) H End of case to center of Field Electrical iring Connection (top of case) 39 5 /8 (1006) 63 5 /8 (1616) 87 7 /8 (2232) 135 3 /8 (3451) Back of case to center of Field Electrical iring Connection 20 1 /4 (514) 20 1 /4 (514) 20 1 /4 (514) 20 1 /4 (514) Length of electrical wireway 44 5 /8 (1133) 33 1 /2 (851) 45 7 /8 (1165) 45 7 /8 (1165) (E) H end of case to LH end of electrical wireway (top of case) 46 1 /2 (1181) 70 1 /2 (1791) 94 1 /2 (2400) 142 5 /8 (3630) aste Outlets (F) H End of case to the center of waste outlet 24 1 /8 (613) 24 1 /8 (613) 24 1 /8 (613) 72 1 /4 (1835) Back O/S of case to center of waste outlet(s) 33 1 /2 (851) 33 1 /2 (851) 33 1 /2 (851) 33 1 /2 (851) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) efrigeration Outlet (G) Back of case to center of refrigeration outlet 29 (737) 29 (737) 29 (737) 29 (737) End of case to center of refrigeration outlet 8 1 /2 (216) 8 1 /2 (216) 8 1 /2 (216) 8 1 /2 (216) 4 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDF5SM Merchandiser Data Sheet

Electrical Data Insight IDF5SM Number of Fans 4 ft 6 ft 8 ft 12 ft 8.25 1 2 2 3 Amperes atts Evaporator Fan 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft 120V 60Hz Energy Efficient 0.25 0.56 0.50 0.75 16 36 32 48 230V 50/60Hz Energy Efficient 0.13 0.27 0.26 0.39 16 36 32 48 Condensate Pump 120V 60Hz 1.9 1.9 1.9 1.9 230V 60Hz 1.0 1.0 1.0 1.0 Minimum Circuit Ampacity 120V 60Hz Energy Efficient 2.83 3.14 3.08 3.33 230V 50/60Hz Energy Efficient 1.58 1.72 1.71 1.84 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Only lighting configurations that are compliant with the U.S. Dept. of Energy (DOE) 2017 regulation are available for sale for use in the U.S.A. STANDAD LIGHTING EcoShine II Canopy 1 ow EcoShine II 0.16 0.26 0.32 0.48 19.3 31.6 38.6 58.0 OPTIONAL LIGHTING EcoShine II Canopy 1 ow EcoShine II HO 0.22 0.33 0.44 0.66 26.5 39.5 53.0 79.4 EcoShine II Shelf 1 ow of Shelves 0.08 0.12 0.16 0.25 9.9 14.1 19.8 29.7 2 ows of Shelves 0.16 0.23 0.33 0.49 19.8 28.2 39.5 59.3 3 ows of Shelves 0.25 0.35 0.49 0.74 29.7 42.3 59.3 89.0 4 ows of Shelves 0.33 0.47 0.66 0.99 39.5 56.4 79.1 118.6 5 ows of Shelves 0.41 0.59 0.82 1.24 49.4 70.5 98.9 148.3 6 ows of Shelves 0.49 0.70 0.99 1.48 59.3 84.5 118.6 178.0 EcoShine II ail Light 1 ow 0.08 0.12 0.16 0.25 9.9 14.1 19.8 29.7 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A..HUSSMANN.COM 5 of 11

ENDS or PATITIONS Each standard end and each insulated partition adds 1 1 /2 in. (38 mm) to case line up. Optional view end with end bumper adds 3 3 /4 in. (95 mm). PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Schedule 40 PVC Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 ESTIMATED SHIPPING EIGHT Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 770 (350) 930 (422) 1080 (490) 1190 (540) 80 (36) Actual weights will vary according to optional kits included. Shelf Options Approved shelf sizes for standard (horizontal, 2-3 position brackets) displays: 18-inch 20-inch 22-inch 24-inch Contact engineering for non-standard (4 position brackets or other) display recommendations. Minimum number of Shelves: 3 Optimal number of Shelves: 4 Maximum number of Shelves: 8 Maximum number of Lighted Shelves: 6 Standard shelf complement for test purposes: (4) rows of 22-in. shelves evenly distributed vertically. 6 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDF5SM Merchandiser Data Sheet

eplacement Parts List Part # Description Part # Description Fan Assemblies 4 Ft, 6 Ft, 8 Ft & 12 Ft Standard HE Fan Assembly 0535563 8.25-in. Fan Assembly Thermostats Optional s and Power Supply 0501213 Power Supply LED Canopy Fixture eplace with like fixtures. LED Shelf Fixture eplace with like fixtures. LED ail Fixture eplace with like fixtures. Coils Other 0534323 4 ft, 8 ft, 12 ft 0534322 6 ft only 0536831 Honeycomb hite (4 ft, 8 ft, 12 ft) 0536829 Honeycomb hite (6 ft only) Varies Thermo-expansion Valve 0534361 Fan Speed Key 1500 PM 0534013 Fan Speed Selector NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available. Descriptions including size and color are at http://www.hussmann.com/ en/products/led-lighting/pages/default.aspx. For additional parts information, visit http://www.hussmann.com/en/pages/aftermarket-parts.aspx HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A..HUSSMANN.COM 7 of 11

Fan iring Offtime Defrost Optional 120VAC Field Connection GND Fan Speed Selector 24VDC Positive () 24VDC Signal (O) 24VDC Ground () GND Fan Motor Fan Motor Fan Motor LED Canopy Light Circuits 4-Ft 6-Ft & 8-Ft 12-Ft EcoShine II LED Canopy Lighting - 1 ow G Case Ground Bar Orange or Tan Band Power Supply >> > >> >> >> >> >> > 4-Ft Case 6-Ft or 8-Ft Case 12-Ft Case LED Canopy Fixture LED Canopy Fixture LED Canopy Fixture Optional Lighting - EcoShine II LED ail - 1 ow 4-Ft Case 6-Ft or 8-Ft Case 12-Ft Case LED ail Fixture LED Canopy Fixture LED Canopy Fixture ANING All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow G = Green = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD GOUND = CASE GOUND 8 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDF5SM Merchandiser Data Sheet

Optional Shelf Harness and LED Light Circuits for 4 or 5 ows of Shelves G Power Supply Power Supply 4 ft case 6 ft or 8 ft case Shelf Light Plug & eceptacle (Typical) 12 ft case ANING All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow G = Green = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD GOUND = CASE GOUND HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A..HUSSMANN.COM 9 of 11

Optional Shelf Harness and LED Light Circuits for 6 or 7 ows of Shelves G Power Supply Power Supply Power Supply 4 ft case 6 ft or 8 ft case Shelf Light Plug & eceptacle (Typical) 12 ft case ANING All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow G = Green = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD GOUND = CASE GOUND 10 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDF5SM Merchandiser Data Sheet

Estimating efrigeration and Electrical Load (for comparison purposes only) Case Btu To determine Btu for a case, refer to the performance data chart on page 2. Select lit or unlit shelves, then select the type of remote refrigeration system (parallel or conventional), which will give Btu/hr/ft. Multiply this number by the length of the case to determine Btu per hour. Add 10 BTU/H/FT for each row of LED shelf lights. Case Electrical efer to store legend to determine number of circuits. Lighting should be specified in store legend. Fan electrical load for a case is computed by selecting the case length and fan voltage on page 6. For example, a 12 ft case uses 3 fans. The store legend specifies fans on a 230V circuit. In this instance, fans use 0.39 Amps and the MCA is 1.84. hen applied, ambient fans, anti-sweat heaters, controllers, etc. must be included in the MCA. Include lights in the MCA if lights are on same circuit. Lights may be on a separate circuit. To estimate lighting load: select case length (12 ft), canopy lighting [standard or optional] (here 0.70 for standard), and shelf or rail lighting [maximum for which case is wired] (1.48 for six shelves); then add together [0.48 + 1.48 = 1.96 amps for 120V] (for 230V, multiply 1.96 * 0.52 = 1.02). Line Sizing efer to store legend. Hussmann Line Sizing Charts are engineered for use with Hussmann refrigeration equipment. Scan Q code to access product information on your mobile device. evision History evision A: May 2016: Original Issue evision B: August 2016: Updated cross section and plan view. evision C: January 2017: Added rail light updates. evision D: April 2017. Updated LED energy values. evision E: April 2017. Updated LED energy values. evision F: September 2017. Updated notes page. evision G: October 2018. Updated refrigerant charges. HUSSMANN COPOATION BIDGETON, MO 63044-2483 U.S.A..HUSSMANN.COM 11 of 11