Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Similar documents
BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

AXIAL FANS Catalogue CN0050C01 May 2008

Size and Configurations

MAJAX-2 GENERAL SPECIFICATION

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Bifurcated Case Axial Fans (BIFA)

Hison Axial Flow Fans

Hison Axial Flow Fans

Unobox units with backward curved centrifugal impellers

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Short casing. Long casing (L version) Commercial premises

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

AND AXIAL FLOW FANS ECOFIT

TGT Series Adjustable Pitch Fans

Vent-Axia Sabre Sickle Roof Fans (VSR)

CYLINDRICAL CASED AXIAL FLOW FANS

TGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

Section 4. Axial Fans - Section 4

JM Aerofoil Multi-Stage 50 Hz

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Section 4 e c tio - P lat F a n s

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

AC Commercial Fans Edition. ErP ready

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

IN-LINE CENTRIFUGAL DUCT FANS VT Series

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

High Performance Axial Fans

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

SQUIF HIGH TEMPERATURE FANS

Max. airflow m 3 /s Diam. min. Diam. max

BIFLOW SB CON Product Brochure


BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

ROOFMASTER STEF-HT ROOF FAN

Axial fans. What s more, non-stock models are normally available within two weeks.

AXIAL FLOW CABINET FAN CGT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

forward curved inline duct blowers

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

Uniclass L7534. Manufacture controlled to ISO9001

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Medium Pressure Centrifugal Fans

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013


HIGH-POWERED VENTILATORS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Sabre Plate Mounted Sickle Fans (VSP)

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

ExpressBuild STANDARD FAN RANGE

HIGH TEMPERATURE TWIN SQUIF FANS

ARAGON MOTO R S. Three Phase Induction Motors

Sabre Sickle Fan Assisted Roof Cowls (VSR)

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

AXUS HIGH TEMPERATURE AXIAL FANS

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

"LCA"- long cased axial fan

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

ROOFMASTER STEF-ATEX ROOF FAN

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

SQUARE INLINE CENTRIFUGAL FANS

Mixed Flow Roof Fans (RMH)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

ACOUSTIC CABINET FANS CVB / CVT Series

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

Square Mixed Flow Fans (MFQ)

Twin City Fan & Blower

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

REVOLUTION SLCX Product Brochure

Performance. Sound Levels. Impellers. Motors. Accessories

CENTRIFUGAL IN-LINE FANS VENT Series

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Transcription:

DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made of PPG, PAG or pressure-casted Aluminium. Finish Painting or galvanised after manufacture are normal finishes on all parts. Operating Temperature -20 C to +55 C Motors Totally enclosed Class F motor, to a min. IP54 protection are fitted as standard. Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW and above are star/ delta starting. Kruger Ventilation Industries Pte Ltd certifies that the TDA 450 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Airflow Direction Air flowing from impeller to motor (B) are fitted as standard. Air flowing from motor to impeller (A) can be supplied on request. MODEL: TDA- 450/9AA/8-8/ / - / Motor no. of pole 4 or 6 Motor Power kw Airflow direction A or B Blade angle - 11, 16, 21, 26, 31 Type of casing construction L or M * All Dimension in mm 12 x 10 TDA-M = 255 TDA-L = 400 450 490 530 LEA450/1.E2-June 2016

6 TDA 450/ 9AA/ 8-8/ / _ 950rpm - 50Hz ρ=1.2kg/m3 Hub:26 - Performance shown is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of app urtenances (accessories). - The A-weighted sound ratings shown have been calculated per AMCA International standard 301. Values shown are for inlet L wi(a) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.

DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made of PPG, PAG or pressure-casted Aluminium. Finish Painting or galvanised after manufacture are normal finishes on all parts. Operating Temperature -20 C to +55 C Motors Totally enclosed Class F motor, to a min. IP54 protection are fitted as standard. Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW and above are star/ delta starting. Kruger Ventilation Industries Pte Ltd certifies that the TDA 450 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Airflow Direction Air flowing from impeller to motor (B) are fitted as standard. Air flowing from motor to impeller (A) can be supplied on request. MODEL: TDA- 450/9AA/8-8/ / - / Motor no. of pole 4 or 6 Motor Power kw Airflow direction A or B Blade angle - 11, 16, 21, 26, 31 Type of casing construction L or M * All Dimension in mm 12 x 10 TDA-M = 255 TDA-L = 400 450 490 530 LEA450/2.E2-June 2016

6 TDA 450/ 9AA/ 8-8/ / _ 1150pm - 60Hz ρ=1.2kg/m3 Hub:26 - Performance shown is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of app urtenances (accessories). - The A-weighted sound ratings shown have been calculated per AMCA International standard 301. Values shown are for inlet L wi(a) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.

DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made of PPG, PAG or pressure-casted Aluminium. Finish Painting or galvanised after manufacture are normal finishes on all parts. Operating Temperature -20 C to +55 C Motors Totally enclosed Class F motor, to a min. IP54 protection are fitted as standard. Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW and above are star/ delta starting. Kruger Ventilation Industries Pte Ltd certifies that the TDA 450 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Airflow Direction Air flowing from impeller to motor (B) are fitted as standard. Air flowing from motor to impeller (A) can be supplied on request. MODEL: TDA- 450/9AA/8-8/ / - / Motor no. of pole 4 or 6 Motor Power kw Airflow direction A or B Blade angle - 11, 16, 21, 26, 31 Type of casing construction L or M * All Dimension in mm 12 x 10 TDA-M = 255 TDA-L = 400 450 490 530 LEA450/3.E2-June 2016

6 TDA 450/ 9AA/ 8-8/ / _ 1450rpm - 50Hz ρ=1.2kg/m3 Hub:26 - Performance shown is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of app urtenances (accessories). - The A-weighted sound ratings shown have been calculated per AMCA International standard 301. Values shown are for inlet L wi(a) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.

DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made of PPG, PAG or pressure-casted Aluminium. Finish Painting or galvanised after manufacture are normal finishes on all parts. Operating Temperature -20 C to +55 C Motors Totally enclosed Class F motor, to a min. IP54 protection are fitted as standard. Standard motor up to 2.2kW are usually supplied on DOL starting, motor 3.0kW and above are star/ delta starting. Kruger Ventilation Industries Pte Ltd certifies that the TDA 450 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Airflow Direction Air flowing from impeller to motor (B) are fitted as standard. Air flowing from motor to impeller (A) can be supplied on request. MODEL: TDA- 450/9AA/8-8/ / - / Motor no. of pole 4 or 6 Motor Power kw Airflow direction A or B Blade angle - 11, 16, 21, 26, 31 Type of casing construction L or M * All Dimension in mm 12 x 10 TDA-M = 255 TDA-L = 400 450 490 530 LEA450/4.E2-June 2016

6 TDA 450/ 9AA/ 8-8/ / _ 1750rpm - 60Hz ρ=1.2kg/m3 Hub:26 - Performance shown is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of app urtenances (accessories). - The A-weighted sound ratings shown have been calculated per AMCA International standard 301. Values shown are for inlet L wi(a) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.