Instruction Manual Electronic Crane Scales. Logbook Regular maintenance and care KERN HUS/HUM Version /2011 GB

Similar documents
KERN HFM Version /2010 GB

KERN HCB / HCN Version /2013 GB

KERN HTS-A Version /2014 GB

KERN HFB Version /2012 GB

KERN HCB / HCN Version /2016 GB

KERN HFO Version /2015 GB

Operating Instructions Precision balance

KERN HFB Version GB

KERN HFA Version /2015 GB

SAUTER TVO Version /2014 GB

Operating instructions Platform/floor scales

Operating Instructions School Balance

Operation instructions Platform/floor scales

Operating manual Platform/floor scales

KERN HFD Version GB

Operating Instructions Precision balance

User Manual. PBA428 Weighing platform

Operating instruction Compact balance

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC


Operating instructions Step-On Personal scale. KERN MPD_M Version /2015 GB

Operating manual FP-2. Index

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

Quick Guide. brite Advanced Retail scale

Crane fork KGM/KGA and KGQ/KGL

TriScroll TM 300 Series Dry Scroll Vacuum Pump

Operating instructions Medical Chair scale

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Assembly and Maintenance Manual Type ASNU

Instructions for use L 2015

KERN KFP_V20 Version /2012 GB

Compact Scales. Software Revision V1.25 & above

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

c-go 24V/6A 24V/8A 24V/12A

Assembly and Maintenance Manual Type AS

SSP-Series Portable Balances Operation Manual

Operating Instruction for Electronic Pressure Switch. Model: PDD

N CX 5500 DAT Operating and Instruction manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

3. Operating instructions: Minor 200

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Note. Solid version. TÜV-tested safety. Lisa Mayer Product specialist Hanging scales/crane scales

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Virtual Measurements & Control. VC210 Operators Manual

HST-BL-2830MS & HST-BL-2830MS-USA

Ohaus ES Series Bench Scale

ON SAFEGUARD S ON SAFEGUARD M

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

MANUAL. Single charger

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales For hazardous areas

Assembly and Maintenance Manual Type RSBW

HIGHLIGHT. Note KERN HCD. Hanging scales/crane scales. Complete crane scale for lower to medium load ranges

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Operating manual Medical Stand assist scales

KeContact P20. User manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

2 TONNE TROLLEY JACK

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

Translation of the Original operating instructions Lifting device Z 70 /...

Service manual Precision balance

Valor 2000 Series Instruction Manual

Operators Guide: RoboSign Stop/Go Traffic Control System

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

Operators Guide: RoboSign Stop/Go Traffic Control System

Operating manual Multi-function weighing balance

User Manual Pocket Pro, Pro + ph

This document hosted by: Operating Manual. Economical Precision Balances. CZ Series

Dumper OPERATOR S MANUAL

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Catapult 1000 Series Instruction Manual

Safety instructions. Always... Never... Fire hazard! Dear customer,

Turbocharger / A100-L Original assembly instructions English

Instructions for Use Plain Trolley ULK Geared Trolley UHK

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

ALFRA Akku-Compact Flex Handstanze Art.-Nr / Prod.-No / N art / Nº de prod

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

ECONOMISER SERIES E2T USER MANUAL

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

DC Master 24/ A

Owner s Manual Gantry Cranes

EASY CHARGE Weather-resistant fixed mount Battery Charger

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

ASSEMBLY AND OPERATING MANUAL LTW PIPE GRAB TYPE GZ 5,0 t

WK 120QMM-6M/Z EL 120QMM-6M/M12

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

Transcription:

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Electronic Crane Scales Logbook Regular maintenance and care KERN HUS/HUM Version 3.1 11/2011 GB HUS/HUM-BA-e-1131

GB KERN HUS/HUM Version 3.1 11/2011 Operating instructions / logbook Electronic Crane Scales Contents 1. Technical data 4 1.1 Dimensions (mm) 6 2. General S afety Instructions 7 3. The crane scales at a glance 10 3.1 Overview 10 3.2 Display 12 3.3 Keyboard 13 3.4 Radio remote control 14 3.5 Label 15 4. Commis s ioning 16 4.1 Unpacking 16 4.2 Checking the original dimensions 16 4.3 Power supply - rechargeable battery mode 17 4.4 Suspending the balance 18 5. Operation KERN HUM 19 5.1 Safety instructions 19 5.2 Loading the crane scales 21 5.3 Turn on/off 24 5.4 Set balance to zero 24 5.5 Taring 25 5.6 Weighing 25 5.7 Record weight value (freeze) 26 5.8 Automatic switch-off (AUTO OFF) 26 6. Operation KERN HUS 28 6.1 Safety instructions 28 6.2 Loading the crane scales 30 6.3 Turn on/off 33 6.4 Set balance to zero 33 6.5 Taring 34 6.6 Weighing 34 6.7 Record weight value (freeze) 35 6.8 Automatic switch-off (AUTO OFF) 35 2 HUS/HUM-BA-e-1131

7. Adjus tment 37 7.1 KERN HUM 37 7.2 KERN HUS 39 8. E rror messages 40 9. Cleaning, Maintenance and Dis pos al 40 9.1 Cleaning and Disposal 40 9.2 Regular maintenance and care 41 9.3 Checklist regular maintenance, (see chapter 9.2) 42 9.4 KERN HUM 42 9.5 KERN HUS 45 10. E nclos ure 48 10.1 Checklist Enhanced maintenance (General revision) 48 10.2 List spare parts and repair of safety-relevant parts 49 11. Declaration of Conformity 51 HUS/HUM-BA-e-1131 3

1. Technical data KERN HUM 1000K500 HUM 3000K100 Readability (d) 500 g 1 kg Weighing range (max) 1 000 kg 3 000 kg Taring range (subtractive) 1 000 kg 3 000 kg Reproducibility 500 g 1 kg Linearity ±1 kg ±2 kg Recommended adjustment weight, not added (class) 1 t (M3) 2 t (M3) Possible Adjustment Points 500 kg; 1 t 1 t; 2 t Stabilization time Precision Warm-up time Unit Allowable ambient temperature Relative humidity Input Voltage Secondary voltage powerpack Rechargeable battery (standard equipment) Display Housing size W x D x H, (mm) Housing material Material hooks and shackle 2 s 0.2 % of max. 10 min kg 0 +40 C 0 to 85 %, non-condensing 100 240VAC 12VDC, 500 ma Output 6 V 10 Ah Service life 80 h Loading time 8 h Digit height 25 mm 210 x 228 x 180 Metal, lacquered Painted steel Net weight (kg) 16 18 Remote control (standard 1 battery (23A, 12V) included equipment) 4 HUS/HUM-BA-e-1131

KERN HUS150K50 HUS300K100 HUS600K200 Readability (d) 0.05 kg 0.1 kg 0.2 kg Weighing range (max) 150 kg 300 kg 600 kg Taring range (subtractive) 150 kg 300 kg 600 kg Reproducibility 0.05 kg 0.1 kg 0.2 kg Linearity ± 0.1 kg ±0.2 kg ±0.4 kg Recommended adjustment weight, not added (class) 100 kg (M3) 200 kg (M3) 2x200 kg (M3) Possible Adjustment Points 40 kg; 100 kg 100 kg; 200 kg 200 kg; 400 kg Stabilization time Precision Warm-up time Unit Allowable ambient temperature Relative humidity Input Voltage Secondary voltage powerpack Rechargeable battery (standard equipment) Display Housing size W x D x H, (mm) Housing material Material hooks and shackle 2 s 0.2 % of max. 10 min kg 0 +40 C 0 to 85 %, non-condensing 100 240VAC 9VDC, 500 ma Output 6 V 4.5 Ah Service life 120 h Loading time 8 h Digit height 23 mm 150 x 145 x 160 Plastic Painted steel Net weight (kg) 4.0 18 Remote control (standard 2 x 1.5 V AAA included equipment) HUS/HUM-BA-e-1131 5

1.1 Dimensions (mm) KERN HUS KERN HUM A B C D A B C D HUS150K50 24 14 330 380 HUM 1000K500 56 42 550 620 HUS300K100 24 14 330 380 HUM 3000K100 73 45 580 650 HUS600K200 24 14 350 400 6 HUS/HUM-BA-e-1131

2. General Safety Instructions Duties of the owner-operator Follow the national accident prevention regulations as well as the working, operating and safety regulations of the owner-operator. Observe all safety regulations of the crane manufacturer. The balance may only be used for the proposed purpose. Any type of use which is not specified in these operating instructions, will be considered as improper use. The customer is solely responsible for material damage and injury of persons resulting from an improper use, Messrs. KERN & Sohn will not be liable under any circumstance. Messrs. KERN & Sohn cannot be held liable, if the crane scales are modified or used improperly and if damage is resulting from such use. Carry out regular maintenance and care of the crane scales, the crane and the load suspension devices (see chapter 9). Log the test result and keep it in the logbook. Organizational measures Only trained and instructed staff may operate the balance. Make sure that the operating instructions are kept nearby the operation site of the crane scales. Assembly, commissioning and maintenance should only be carried out by trained specialists. Repair of safety-relevant pieces may only be carried out by KERN or by service partners authorized by Messrs. KERN. (competence certificate or training). Use original spare parts only. All repairs and spare parts must be documented by the service partner (see list, chap. 10.2). All maintenance must be documented (see checklist chap. 9.3). Load suspending components may only be exchanged as a complete spare parts set. The dimensions of the new components must be noted (see checklist chapter 9.3). Environmental conditions Never operate the crane scales in explosive environment. The serial version is not explosion protected. Operate the crane scales only under environmental conditions as specified in these operating instructions (especially in chapter 1 Technical data ). Do not expose the crane scales to strong humidity. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature. Do not operate the crane scales in corrosive environment. Protect the crane scales against high humidity, vapours and dust. HUS/HUM-BA-e-1131 7

Major display deviations (incorrect weighing results) may be experienced should electromagnetic fields (e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference. Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a non-automatic balance, i.e. the material to be weighed is suspended on the crane hook only vertically, manually, carefully and without jerks. As soon as a stable weighing value is reached the weighing value can be read. Use the crane scales only for lifting and weighing of freely movable loads. Danger of injury due to improper use. Not allowed are e.g.: - Exceeding the allowed nominal load of crane, crane scales or any type of load attachment devices - Conveying persons, - Pulling loads over an inclined surface, - Tearing-off, pulling or towing loads. Modifications or reconstructions of the crane scales or of the crane are not allowed. Improper Use Do not use balance for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the stability compensation. (Example: Slowly draining fluids from a container suspended on the balance.) Do not leave permanent load suspended on the balance. This may damage the measuring system as well as safety-relevant parts. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the described uses The appliance is modified or opened Mechanical damage and damage caused by media, liquids, Natural wear and tear The appliance is improperly set up or incorrectly electrically connected The measuring system is overloaded Safe working Do not stand underneath suspended loads! Position the crane in a way that the load is lifted vertically. When working with the crane and crane scales wear personal safety equipment (helmet, safety shoes etc.). 8 HUS/HUM-BA-e-1131

Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. In KERN s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost. Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage. Initial Commissioning In order to obtain exact results with the electronic balances, your balance must have reached the operating temperature (see warming up time chap. 1). During this warming up time the balance must be connected to the power supply (mains, accumulator or battery). The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter Adjustment. For checking original dimensions, s. chap. 4.2 Shutdown and storage Take off the crane scales from the crane and dismantle all load attachment devices from the crane scales. Do not store the crane scales at open air HUS/HUM-BA-e-1131 9

3. The crane scales at a glance The crane scales are a multi-purpose and cost-saving solution for overhead weighing applications such as e.g. recycling, metal processing, machine engineering, transport and logistics. With the radio remote control, operation will be more comfortable yet. 3.1 Overview KERN HUS 1 Eyelet 2 Display 3 Keyboard 4 Safety bracket 5 Hook, revolvable 6 For radio remote control, s. chap. 3.4 10 HUS/HUM-BA-e-1131

KERN HUM 1 Shackle 2 Antenna 3 Display 4 Keyboard 5 Safety bracket 6 Hook, revolvable 7 For radio remote control, s. chap. 3.4 HUS/HUM-BA-e-1131 11

3.2 Display 1. KERN HUS The indicator appears next to ZERO when weight is around Zero point range. The indicator appears next to TARE after scales have been tared. The indicator next to kg shows that the weight unit currently displayed is kg. 2. KERN HUM The LED above ZERO is illuminated when weight is around Zero point range. The LED above TARE is illuminated after scales have been tared. The LED above ZERO is illuminated when the weight unit currently displayed is kg. 12 HUS/HUM-BA-e-1131

3.3 Keyboard 1. KERN HUS Taste Funktionsbeschreibung ON/ZERO Turn on the balance Taring TARE Select function in menu Select menu settings MODE Turn on or off backlight Record weight value (freeze) HOLD Exit menu OFF Turn off the balance 2. KERN HUM Key Description of function ZERO Zeroing Taring TARE Select function in menu MODE Select menu settings Record weight value (freeze) HOLD Exit menu POWER Turn on or off the balance HUS/HUM-BA-e-1131 13

3.4 Radio remote control The balance can be operated by the radio remote control like by a keyboard. All functions (excepted POWER ON/OFF) can be selected. The LED should light up each time a key is pressed. If it does not light up, the batteries in the remote control must be exchanged. 1. HERN HUS Range on free surface (free of buildings) approx. 2.5 m. Key Remote control POWER Corresponding key on scales ON/ZERO Function Standby mode Weighing mode ZERO ON/ZERO Zeroing TARE TARE Taring MODE HOLD MODE HOLD Select menu settings Turn on or off backlight Record weight value (freeze) 2. HERN HUM Range on free surface (free of buildings) approx. 25 m. Key Remote control Corresponding key on scales Function Z ZERO Zeroing T TARE Taring M MODE Select menu settings H HOLD Record weight value (freeze) 14 HUS/HUM-BA-e-1131

3.5 Label Do not exceed nominal load of crane scales. (Example) The product conforms to the requirements of the German Equipment and Product Safety Act. HUS/HUM-BA-e-1131 15

4. Commissioning Attention: Always observe chapter 2 General Safety Instructions! 4.1 Unpacking Once delivered and unpacked, crane scales will not be taken back. SAFETY INSTRUCTIONS for protection against break CAUTION Danger for the back! The crane scales have been sealed by Messrs. KERN. Shackles and hooks are sealed by Sella tape. The packaging is also sealed by adhesive tape. + Broken seal obliges to purchase. Thanks for your comprehension. Your KERN Quality assurance team The crane scales are compact and quite heavy. Remove the scales from packaging only with the help of a second person. Use a lifting device such as a crane or a forklift truck. Secure the scales that they cannot fall down when they are lifted. Only use original packaging for returning. Make sure that all parts are completely present. Crane scales Rechargeable battery Mains adapter Remote control Operating instructions (logbook) 4.2 Checking the original dimensions Enter the original dimensions shown on the production data sheet in the grey boxes of checklist chap. 9.3. Check original dimension of crane scales; for implementation see chap. 9.2 Regular Maintenance Enter all data (date, tester, results) in the first line under Inspection before first use in the checklist (see chapter 9.3) CAUTION If the dimensions of your first safety inspection do not match those of KERN, the balance must not be put into operation. In this case please contact a service partner authorised by Messrs. KERN. 16 HUS/HUM-BA-e-1131

4.3 Power supply - rechargeable battery mode Material damage on crane scales Only use the delivered mains adapter. CAUTION Make sure that the mains adapter, the cable and the mains plug are in a perfect condition. Do not use the crane scales during the loading process. Recharge battery: Rechargeable battery status display The LED display informs you during loading about the loading status of the rechargeable battery. red: Voltage has dropped below prescribed minimum. green: Battery is completely charged. Mains adapter connection Before the first use, the rechargeable battery should be charged by connecting it to the mains power cable for at least 10 hours. To conserve energy, enable the automatic switch-off function AUTO OFF, KERN HUM see chap.. 5.8./ KERN HUS see chap..6.8. When the crane scales are out of operation for a longer period, remove the rechargeable battery. HUS/HUM-BA-e-1131 17

4.4 Suspending the balance Condition The crane needs a safety bracket (1) that the unloaded crane scales cannot fall down. If the safety bracket is missing or damaged, please contact the crane manufacturer in order to receive a hook with this safety equipment. Suspend the crane scales on the lower hook of a crane and close the safety bracket. The crane scale s upper eyelet should rest in the saddle (2). 18 HUS/HUM-BA-e-1131

5. Operation KERN HUM 5.1 Safety instructions Risk of injury due to falling loads! Danger Take great care when operating the crane and follow the general rules for crane operation. Check all parts (hook, eyelet, rings, rope slings, cables, chains etc.) for excessive wear or damage If faults can be seen on the safety bracket of the hook or if it is missing completely, the scales must not be used Work only with appropriate speed Do not stand or go under suspended loads. Do not use on building site. Keep an eye on suspended loads. (Example) Do not exceed the nominal load of crane, crane scales or any kind of load attachment devices at the crane scales. HUS/HUM-BA-e-1131 19

Make sure that scales are loaded in vertical direction of pull Always avoid vibrations and horizontal forces. Avoid any kind of shock, torsion and oscillating (e.g. caused by inclined suspending) Do not use the crane scales for transporting loads. 20 HUS/HUM-BA-e-1131

5.2 Loading the crane scales To achieve good weighing results please refer to the next page, fig. 1 and 2: Only use load attachment devices which guarantee a one-spot suspension and where the scales can be suspended freely. Do not use too large load attachment devices which do not guarantee any onespot suspension. Do not use multiple suspensions. Do not pull or push the load or the loaded balance. Do not pull the hook horizontally. Loading the balance 1. Position the hook of the crane scales over the load. 2. Move downwards the crane scales until the load can be suspended on the hook of the balance. Reduce the speed when the respective height is going to be reached. 3. Suspend the load on the hook. Ensure that the safety bracket is closed. If the load is fixed by slings, ensure that the slings rest completely on the saddle of the balance hook. 4. Lift-off the load slowly. When the load is fixed by slings, ensure that the load is well balanced on both sides and that the slings are correctly positioned HUS/HUM-BA-e-1131 21

Only use load attachment devices which guarantee a one-point suspension and where the scales can be suspended freely. Do not use too large load attachment devices which cannot guarantee a one-point suspension. Fig. 1 22 HUS/HUM-BA-e-1131

Do not push or pull Do not pull the hook horizontally Do not use multiple suspensions Fig. 2 HUS/HUM-BA-e-1131 23

5.3 Turn on/off Start-up Press the POWER-key on the scales keyboard. The display lights up and the balance carries out a selftest. The selftest is completed when the weight value 0 appears on the display. Switch on only possible at the keyboard of the balance. Switching Off Press the POWER-key on the scales keyboard. 5.4 Set balance to zero In order to obtain optimal weighing results, reset to zero the balance before weighing. Unload the balance Press the ZERO button. In the display appears 0 (kg) and the LED over ZERO lights up. 24 HUS/HUM-BA-e-1131

5.5 Taring Suspend preload. Press the TARE key. In the display appears 0 (kg) and the LED over TARE lights up. The weight of the container is now internally saved. Weigh the material, the net weight will be indicated. After removing the preload weight appears as negative display. The balance is able to only store one taring value at a time. The weighing range (max) for the scales will be reduced by the tared range. To delete the tare value, remove load from weighing pan and press the TARE button. 5.6 Weighing Loading the crane scales. The weight value will be displayed at once. Overload warning Overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. This could cause damage to the balance. Exceeding the maximum load is indicated by the display. Unload balance or reduce preload. HUS/HUM-BA-e-1131 25

5.7 Record weight value (freeze) Press the HOLD button to freeze or to record the current weight value. It remains displayed flashing until it is deleted. In order to delete the "frozen" or the recorded weight, press any button. 5.8 Automatic switch-off (AUTO OFF) Switch off the balance. Press the TARE-key and switch on the scales at the same time. The first function F.1 is displayed. Press the TARE-key repeatedly until F.4 appears on the screen. Confirm by pressing the MODE-key. The current setting will be displayed. 0._OFF: Automatic switch-off function is disabled. 4._OFF: The scales will now switch off automatically after 4 minutes without change of load (default). 26 HUS/HUM-BA-e-1131

Use the MODE button to switch over into the available settings. Save the selected setting by pressing the ZERO-key. The balance returns to weighing mode. HUS/HUM-BA-e-1131 27

6. Operation KERN HUS 6.1 Safety instructions Risk of injury due to falling loads! Danger Take great care when operating the crane and follow the general rules for crane operation. Check all parts (hook, eyelet, rings, rope slings, cables, chains etc.) for excessive wear or damage If faults can be seen on the safety bracket of the hook or if it is missing completely, the scales must not be used Work only with appropriate speed Do not stand or go under suspended loads. Do not use on building site. Keep an eye on suspended loads. (Example) Do not exceed the nominal load of crane, crane scales or any kind of load attachment devices at the crane scales. 28 HUS/HUM-BA-e-1131

Make sure that scales are loaded in vertical direction of pull Always avoid vibrations and horizontal forces. Avoid any kind of shock, torsion and oscillating (e.g. caused by inclined suspending) Do not use the crane scales for transporting loads. HUS/HUM-BA-e-1131 29

6.2 Loading the crane scales To achieve good weighing results please refer to the next page, fig. 3 and 4: Only use load attachment devices which guarantee a one-spot suspension and where the scales can be suspended freely. Do not use too large load attachment devices which do not guarantee any onespot suspension. Do not use multiple suspensions. Do not pull or push the load or the loaded balance. Do not pull the hook horizontally. Loading the balance 1. Position the hook of the crane scales over the load. 2. Move downwards the crane scales until the load can be suspended on the hook of the balance. Reduce the speed when the respective height is going to be reached. 3. Suspend the load on the hook. Ensure that the safety bracket is closed. If the load is fixed by slings, ensure that the slings rest completely on the saddle of the balance hook. 4. Lift-off the load slowly. When the load is fixed by slings, ensure that the load is well balanced on both sides and that the slings are correctly positioned 30 HUS/HUM-BA-e-1131

Only use load attachment devices which guarantee a one-point suspension and where the scales can be suspended freely. Do not use too large load attachment devices which cannot guarantee a one-point suspension. Fig. 3 HUS/HUM-BA-e-1131 31

Do not push or pull Do not pull the hook horizontally Do not use multiple suspensions Fig. 4 32 HUS/HUM-BA-e-1131

6.3 Turn on/off Start-up Press the ON/ZERO-key on the scales keyboard. The display lights up and the balance carries out a selftest. The selftest is completed when the weight value 0 appears on the display. Switch on only possible at the keyboard of the balance. Switching Off Press the OFF-key on the scales keyboard. 6.4 Set balance to zero In order to obtain optimal weighing results, reset to zero the balance before weighing. Unload the balance Press the ON/ZERO button. In the display appears 0 (kg) and the indicator appears next to ZERO. HUS/HUM-BA-e-1131 33

6.5 Taring Suspend preload. Press the TARE key. In the display appears 0 (kg) and the indicator next to TARE. The weight of the container is now internally saved. appears Weigh the material, the net weight will be indicated. After removing the preload weight appears as negative display. The balance is able to only store one taring value at a time. The weighing range (max) for the scales will be reduced by the tared range. To delete the tare value, remove load from weighing pan and press the TARE button. 6.6 Weighing Loading the crane scales. The weight value will be displayed at once. Overload warning Overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. This could cause damage to the balance. Exceeding the maximum load is indicated by the display. Unload balance or reduce preload. 34 HUS/HUM-BA-e-1131

6.7 Record weight value (freeze) Press the HOLD button to freeze or to record the current weight value. It remains displayed flashing until it is deleted. In order to delete the "frozen" or the recorded weight, press any button. 6.8 Automatic switch-off (AUTO OFF) Switch off the balance. Press the TARE-key and switch on the scales at the same time. The first function F.1 is displayed. Press the TARE-key repeatedly until F.4 appears on the screen. Confirm by pressing the MODE-key. The current setting will be displayed. 0._OFF: Automatic switch-off function is disabled. 4._OFF: The scales will now switch off automatically after 4 minutes without change of load (default). HUS/HUM-BA-e-1131 35

Use the MODE button to switch over into the available settings. Save the selected setting by pressing the ON/ZERO-key. The balance returns to weighing mode. 36 HUS/HUM-BA-e-1131

7. Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out for the first commissioning, after each change of location as well as in case of fluctuating environment temperature. To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. Carry out adjustment as close as possible to the maximum load of the scales, see chap. 1 Technical data. Weights providing different nominal values can be used but from a metrological point of view this is not ideal. For admissible adjustment weights see table 1. Info about test weights can be found on the Internet at: http://www.kern-sohn.com Tab. 1: Model HUS150K50 HUS300K100 HUS600K200 HUM 1000K500 HUM 3000K100 Admissible Adjustment Weights 40 kg; 100 kg 100 kg; 200 kg 200 kg; 400 kg 500 kg; 1 t 1 t; 2 t 7.1 KERN HUM Observe stable environmental conditions. A warming up time (see chapter 1) is required for stabilization. Switch-off balance and attach a carrying help if necessary. Press and hold ZERO- and MODE whilst at the same time switching on the scales with the carrying aid attached. Release keys, CAL? will be displayed. HUS/HUM-BA-e-1131 37

Press the MODE-key, YES will be displayed, followed by an alternating display such as Load 2000 or 1000. The admissible adjustment weights will be displayed. Attach the admissible adjustment weights (s. table 1). Wait until the scales display done, and start to count down. After successful adjustment the balance carries out a selftest and automatically returns to weighing mode. Remove adjustment weight and also the carrying aid, if attached. An adjusting error or incorrect adjusting weight will be indicated by the error message; repeat adjustment procedure. 38 HUS/HUM-BA-e-1131

7.2 KERN HUS Observe stable environmental conditions. A warming up time (see chapter 1) is required for stabilization. Switch-off balance and attach a carrying help if necessary. Press and hold ON/ZERO- and MODE whilst at the same time switching on the scales with the carrying aid attached. Release keys, CAL? will be displayed. Press the MODE-key, YES will be displayed, followed by an alternating display such as Load 100 or 40, see table 1. The admissible adjustment weights will be displayed. Attach the admissible adjustment weights (s. table 1). Wait until the scales display done, and start to count down. After successful adjustment the balance carries out a selftest and automatically returns to weighing mode. Remove adjustment weight and also the carrying aid, if attached. An adjusting error or incorrect adjusting weight will be indicated by the error message; repeat adjustment procedure. HUS/HUM-BA-e-1131 39

8. Error messages Error message Description Possible causes Flashing number display Maximum load exceeded Capacity of rechargeable battery exhausted Reduce load Check whether the balance has been damaged Recharge battery Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. 9. Cleaning, Maintenance and Disposal Danger Risk of injury and risk of material damage! The crane scales are part of a hoisting device! For a safe operation please observe the following: Have carried out a regular maintenance by trained specialized staff Carry out regular maintenance and care, see chapter 9.2 and 9.3 Have the parts exchanged only by trained specialized staff. If there arose discrepancies with the safety checklist, the balance must not more be put into operation. Do not repair the crane scales by yourself. Repair may only be carried out by service partners authorized by Messrs. KERN. 9.1 Cleaning and Disposal Damage on the crane scales! CAUTION Do not use any industrial solutions or chemicals Clean the keyboard and the display with a soft cloth soaked in mild window cleaning agent. Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. 40 HUS/HUM-BA-e-1131

9.2 Regular maintenance and care The regular 3-month maintenance may only be carried out by an expert with competent knowledge of working with crane scales. Thereby the national regulations for prevention of accidents as well as the working, operation and safety regulations of the owner-operator. To check the dimensions only use suitable test devices. The regular 12-month maintenance must only be carried out by trained specialized staff (KERN customer service). The results of the maintenance must be written down in the checklist (chap. 9.3). The additional results of the extended maintenance have to be entered in the checklist (chapter 10.1). The replaced spare parts also must be entered, (chapter 10.2) Regular maintenance: Initial start-up, every 3 months or definitely after 12 500 weighing processes Check all dimensions, see checklist chap. 9.3 Check the shackle for wear and tear, such as e.g. plastic deformation, mechanical damage (unevenness), notches, striation, cracks, corrosion, thread damage and torsions. Check the application of the safety bracket on the hook, moreover check for fault and correct function Ensure that the positioning screws at the shackle are not loose. If a dimension exceeds the admitted deviation from the original dimension (see checklist, chap. 9.3) or if other discrepancies have been found, the balance must be repaired at once by trained specialized staff (KERN customer service). Never do repair it by yourself! Take balance out of operation immediately! Every 12 months or in any case after 50 000 weighings Every 5 years or anyway after 250 000 weighings Every 10 years or anyway after 500 000 weighings All repairs and spare parts must be documented by the service partner (see list, chap. 10.2). If the enhanced maintenance has to be carried out by trained staff (KERN customer service). At this general revision all load carrying parts must be checked for gaps with magnetic powder All load carrying parts have to be exchanged by trained specialized staff (KERN customer service). Replace the crane scales entirely Important note When checking for wear and tear please refer to the drawing (KERN HUM fig. 3, chap. 9.3.1; KERN HUS fig. 4, chap. 9.3.2) below. HUS/HUM-BA-e-1131 41

9.3 Checklist regular maintenance, (see chapter 9.2) 9.3.1 KERN HUM Original dimensions crane scales, serial no.: Capacity Shackle Hooks a (mm) b (mm) c (mm) Wear and tear Positioning screws d (mm) e (mm) Angle α ( ) Wear and tear Safety bracket Date Tester Shackle Hooks a b c Wear and tear (see grey fields) Fixing screws d e Angle α Wear and tear (see grey fields) Safety bracket Date Tester Max. admitted variation 5 % 0 % 5 % No deformation or cracks tight 10 % 5 % 10 No deformation or cracks Perfect function Revision prior to first use 3 months / 12 500 x 6 months / 25 000 x 9 months / 37 500 x 12 months / 50 000 x 15 months / 62 500 x 18 months / 75 000 x 21 months / 87 500 x HUS/HUM-BA-e-1131 42

Shackle Hooks a b c Wear and tear (see grey fields) Fixing screws d e Angle α Wear and tear (see grey fields) Safety bracket Date Tester Max. admitted variation 5 % 0 % 5 % No deformation or cracks tight 10 % 5 % 10 No deformation or cracks Perfect working order 24 months / 100 000 x 27 months / 112 500 x 30 months / 125 000 x 33 months / 137 500 x 36 months / 150 000 x 39 months / 162 500 x 42 months / 175 000 x 45 months / 187 500 x 48 months/200 000 51 months / 212 500 x 54 months / 225 000 x 57 months / 237 500 x 60 months/250000x All load carrying parts have to be exchanged by a service partner authorised by KERN. bold letters = this maintenance work has to be carried out by a service partner authorized by KERN. HUS/HUM-BA-e-1131 43

Fig. 3 HUS/HUM-BA-e-1131 44

9.3.2 KERN HUS Original dimensions crane scales, serial no.: Capacity Eyelet Hooks a (mm) b (mm) Wear and tear c (mm) d (mm) Angle α ( ) Wear and tear Safety bracket Date Tester Eyelet Hooks a b Wear and tear (see Wear and tear (see grey grey fields) c d Angle α fields) Safety bracket Max. admitted variation 5 % 0 % No deformation or cracks 10 % 5 % 10 No deformation or cracks Perfect working order Date Tester Revision prior to first use 3 months / 12 500 x 6 months / 25 000 x 9 months / 37500 x 12 months/ 50 000 x 15 months / 62 500 x 18 months / 75 000 x 21 months / 87 500 x HUS/HUM-BA-e-1131 45

Eyelet Hooks a b Wear and tear (see Wear and tear grey fields) c d Angle α (see grey fields) Safety bracket Max. admitted variation 5 % 0 % No deformation or cracks 10 % 5 % 10 No deformation or cracks Perfect working order Date Tester 24 months / 100 000 x 27 months/ 112 500 x 30 months/ 125 000 x 33 months/ 137 500 x 36 months/150000 x 39 months /162 500 x 42 months /175 000 x 45 months /187 500 x 48 months/200000 x 51 months /212 500 x 54 months /225 000 x 57 months /237 500 x 60 months/250000x All load carrying parts have to be exchanged by a service partner authorised by KERN. bold letters = this maintenance work has to be carried out by a service partner authorized by KERN. HUS/HUM-BA-e-1131 46

Fig. 4 HUS/HUM-BA-e-1131 47

10. Enclosure 10.1 Checklist Enhanced maintenance (General revision) The enhanced maintenance has to be carried out by a service partner authorized by KERN. Crane scales Model.. Serial no... Interval Magnetic powder test for cracks Hooks Shackle Screwed connections Date Name Signature 12 months / 50 000 x 24 months / 100 000 x 36 months / 150 000 x 48 months / 200 000 x 60 months / 250 000 x 72 months / 300 000 x 84 months / 350 000 x 96 months / 400 000 x 108 months/450 000 x 120 months/500 000x Replace crane scales entirely HUS/HUM-BA-e-1131 48

10.2 List spare parts and repair of safety-relevant parts Repair has to be carried out by a service partner authorized by KERN. Crane scales Model.. Serial no... Part Action Date Name Signature HUS/HUM-BA-e-1131 49

Crane scales Model.. Serial no... Part Action Date Name Signature HUS/HUM-BA-e-1131 50

11. Declaration of Conformity EC-Konformitätserklärung EC- Déclaration de conformité EC-Dichiarazione di conformità EC- Declaração de conformidade EC-Deklaracja zgodności KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de Konformitätserklärung Tel: 0049-[0]7433-9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de EC-Declaration of -Conformity EC-Declaración de Conformidad EC-Conformiteitverklaring EC- Prohlášení o shode EC-Заявление о соответствии D Konformitätserklärung GB Declaration of conformity CZ Prohlášení o shode E Declaración de conformidad F Déclaration de conformité I Dichiarazione di conformitá NL Conformiteitverklaring P Declaração de conformidade PL Deklaracja zgodności RUS Заявление о соответствии Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. We hereby declare that the product to which this declaration refers conforms with the following standards. Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami. Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt. Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes. Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, jest zgodny z poniższymi normami. Мы заявляем, что продукт, к которому относится данная декларация, соответствует перечисленным ниже нормам. Mark applied EU Directive Standards 2006/95/EC EN 61010-1:2001 Low Voltage Directive 2004/108/EC EMC Directive 2006/42/EC Machine directive EN 55022:2006 EN 61000-3-2:2006 EN 61000-3-3:1995/A1:2001/A2:2005 EN 55024:1998/A1:2001/A2:2003 EN13155:2003+A2:2009 Date: : 12.01.2012 Signature: KERN & Sohn GmbH Management KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149 HUS/HUM-BA-e-1131 51