Application cup for OptiFlex 2 GM03 manual powder gun

Similar documents
WPS02 Waste powder conveying with BIG-BAG station

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

OptiSpray F Manual coating equipment

OptiFlow powder injector (IG02 type)

Operating instructions and spare parts list. OptiFlow powder injector (IG02 type)

Powder injector OptiFlow IG07

Manual coating equipment OptiFlex 2 B

OptiFlow Plug-in injector (IG02)

Manual powder gun OptiFlex 2 GM03

OptiCenter OC01 Powder management center

OptiGun 2-AE1 Enamel automatic gun (GA02-E1 type)

EasySelect GM01-E Manual Powder Gun

XT 6 Horizontal Axis

Operating instructions and spare parts list. XT08 Horizontal axis

Operating Instructions and Spare Parts List. Tilt Table FPS13. Ausgabe 07/02. Tilt Table FPS13

FPS16 Fresh powder system

Powder coating equipment OptiFlex 2 BN (Boron Nitride)

OptiGun 2-AE Automatic Powder Gun (GA02)

OptiGun GA03 Automatic powder gun

Operating instructions and spare parts list. OptiFlex F. Manual coating equipment

MagicCenter MC01 Powder management system

OptiGun GA03-P Automatic powder gun

Quick reference guide. OptiFlex F. Manual coating equipment. Translation of the original operating instructions

Operating instructions and spare parts list. OptiFlex S. Manual coating equipment

Operating instructions and spare parts list. OptiSelect. Manual powder gun

Robot gun RobotGun GM03-R

EasySelect-Cup Manual Powder Gun

Manual coating equipment OptiFlex 2 B

Manual gun OptiSelect GM03

Operating instructions and spare parts list FPS14 Fresh powder system

Operating instructions and spare parts list OptiStar CG07 Manual gun control unit

Manual equipment OptiFlex 2 F

Operating instructions and spare parts list. OptiStar CG07 Manual Gun control unit

Operating instructions and spare parts list. FPS15 Tilt table

Operating instructions and spare parts list. PZ Powder center with Gematic control unit

OptiCenter OC05 Powder management center

Operating instructions and spare parts list. MagicCylinder II Powder coating booth

EASY 1-F Powder Coating Equipment

Operating Instructions and Spare Parts List. ZA02 Reciprocator. EIssued 08/03. ZA02 Reciprocator 29

OptiCenter OC02 Powder management center

Rev EN. Operating instructions and Spare parts list. Vertical axis ZA13. Translation of the original operating instructions

Operating instructions and spare parts list. ZA06 Reciprocator

Assembly and Operating Instructions. SuperCorona. Retrofit set for the PG 1-A Automatic Powder Gun. Issued 05/93. SuperCorona / PG 1-A.

PG 1-A Automatic Powder Gun

PI 1 Plug-in Injector

PG 2-A Automatic Powder Gun (and PG 2-AX Automatic Powder Gun for Quick Colour Changes)

MPS 1-F / MPS 2-F Manual Powder System

Metallic Nozzle Convertion Kit - PG 1 to PG 1-M

Operating Instructions and Spare Parts List. PG 1-Cup Gun. Issued 09/98

Swing Piston Compressors and Vacuum Pumps

Operating instructions

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

MPS 1-B / MPS 2-B Manual Powder System

SPARK PLUG CLEANING KIT OPERATING MANUAL

CRS-D Powder Coating Booth with Reverse Jet Cleaning System

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Printed: Doc-Nr: PUB / / 000 / 00

MPS 1-L Manual Powder System with the PG 1 Powder Gun

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AUTOMATIC AIRSPRAY GUN

original operating manual Operating manual Translation of the Item-No.: ,

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Installation instructions

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

APS 2. Automatic Powder System

Installation instructions

Operating Manual. Automatic spray gun AGR-09 mini, AGR-09 mini with needle stroke limitation for low-pressure atomization

Installation instructions

Installation instructions

ADU 2 Air Distribution Unit

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

HST -LS Interlocking device (Translation of Original Manual)

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation instructions

Installation instructions

Rotary feed-through DDF-S/-KS

Installation instructions

Installation instructions

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions

SCOPELITE TIMING LIGHT OPERATING MANUAL

Installation instructions

Installation instructions

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Installation instructions

Installation instructions

Micro Diaphragm Gas Sampling Pumps

Assembly and Maintenance Manual Type ASNU

Installation instructions

Mini UHV gate valve with manual actuator with pneumatic actuator

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Installation instructions

Installation instructions

Installation instructions

Installation instructions

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Transcription:

En Operating instructions and spare parts list Application cup for OptiFlex 2 GM03 manual powder gun Translation of the original operating instructions

Documentation OptiFlex GM03 application cup Copyright 2010 Gema Switzerland GmbH All rights reserved. This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH. OptiFlex, OptiTronic, OptiGun, EasyTronic, EasySelect, EasyFlow, OptiStar, OptiSelect, OptiFlow and SuperCorona are registered trademarks of Gema Switzerland GmbH. OptiMatic, OptiMove, OptiMaster, OptiPlus, PowerClean, Precise Charge Control (PCC), MultiTronic and Gematic are trademarks of Gema Switzerland GmbH. All other product names are trademarks or registered trademarks of their respective holders. Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders. To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of issue. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice. Printed in Switzerland Gema Switzerland GmbH Mövenstrasse 17 9015 St.Gallen Switzerland Phone: +41-71-313 83 00 Fax.: +41-71-313 83 83 E-Mail: info@gema.eu.com Homepage: www.gemapowdercoating.com

Table of contents General safety regulations 3 Safety symbols (pictograms)... 3 Conformity of use... 3 Product specific security measures... 4 About this manual 5 General information... 5 Function description 7 Field of application... 7 Typical characteristics... 7 Scope of delivery... 7 Application cup... 7 Application cup... 8 Design... 8 Technical data 9 OptiFlex 2 GM03 application cup... 9 General information... 9 Start-up and operation 11 Connecting guide...11 Function check...12 Start-up...13 Fill in powder...13 Switch on the control unit...13 Maintenance and cleaning 15 Daily maintenance...15 Weekly maintenance...15 Cleaning...15 Cleaning the application cup...15 Completely dismantling the application cup...16 Dismantling the application cup...16 Assembling the application cup...16 Troubleshooting 17 General information...17 Spare parts list 19 Ordering spare parts...19 Application cup - spare parts list...20 Application cup - spare parts...21 OptiFlex GM03 application cup Table of contents 1

General safety regulations Safety symbols (pictograms) This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the Application cup. These safety regulations must be read and understood before the Application cup is used. The following warnings with their meanings can be found in the Gema operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions. DANGER! danger due to live electricity or moving parts. Possible consequences: Death or serious injury WARNING! Improper use of the equipment could damage the machine or cause it to malfunction. Possible consequences: minor injuries or damage to equipment INFORMATION! useful tips and other information Conformity of use 1. The Application cup is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating. 2. Any other use is considered as non-conform. The manufacturer is not responsible for any damage resulting from this, the risk for this is assumed by the user alone! If the Application cup is to be used for other purposes or other substances outside of our guidelines then Gema Switzerland GmbH should be consulted. 3. Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of the conformity of use. The Application cup should only be used, maintained and OptiFlex GM03 application cup General safety regulations 3

Product specific security measures started up by trained personnel, who are informed about and are familiar with the possible hazards involved. 4. Start-up (i.e. the execution of a particular operation) is forbidden until it has been established that the Application cup has been set up and wired according to the guidelines for machinery (2006/42 EC). EN 60204-1 (machine safety) must also be observed. 5. Unauthorized modifications to powder spraying equipment exempt the manufacturer from any liability from resulting damage. 6. The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations are to be observed. 7. Furthermore the country-specific safety regulations must be observed. - The installation work, to be done by the customer, must be carried out according to local regulations - Before starting up the plant a check must be made that no foreign objects are in the booth or in the ducting (input and exhaust air) - It must be observed, that all components are grounded according to the local regulations, before start-up 4 General safety regulations OptiFlex GM03 application cup

About this manual General information This operating manual contains all the important information which you require for the working with the Application cup. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system. In order to be able to exploit all the advantages of the application cup, the user should already be familiar with the working techniques and functioning of the powder coating equipment. It is not the function of this manual to give instruction on how to use powder coating equipment. If problems arise during working with the application cup, which are ascribed to the OptiFlex 2 GM03 powder gun or the powder gun control unit, then the corresponding operating instruction manual should be consulted. Information about the function mode of the individual system components - booth, gun control unit, manual gun or powder injector - should be referenced to their enclosed corresponding documents. OptiFlex GM03 application cup About this manual 5

Function description Field of application Typical characteristics Scope of delivery The application cup is built exclusively for electrostatic coating with organic powders. Any other use is considered as non-conform. The manufacturer is not responsible for any damage resulting from this, the risk for this is assumed by the user alone! The application cup is especially suited for manual coating very small series, test coatings at powder manufacturers, and for laboratory tests. The powder types used are to be fluidized without vibration. - The application cup is especially suited for working with minimum quantity of powder - Precise application parameters lead to repeatable application performances - The application cup enables a very quick color change - The application cup can be connected to an OptiFlex 2 GM03 gun by quick release connection - no extra device necessary Application cup - An application cup - complete - A pneumatic connection to the control unit OptiFlex GM03 application cup Function description 7

Application cup Design 5 6b 3 2 4 6 6a 7 1 1 Dip tube 6 Pneumatic connection 2 Application cup 6a Red quick release connection with integrated powder stop (conveying air) 3 Cup connection with injector 6b Black quick release connection with integrated powder stop (supplementary air) 4 Cup cover 7 Bottom with fluidizing plate 5 Elbow joint 8 Function description OptiFlex GM03 application cup

Technical data OptiFlex 2 GM03 application cup General information Application cup 150 ml 500 ml Powder output 30-400 g/min 30-400 g/min Useful capacity Air consumption (application range) 150 ml (approx. 90 g of powder) 500 ml (approx. 300 g of powder) 1,8-4 Nm 3 /h 1,8-4 Nm 3 /h Weight without connections 130 g 310 g Weight with pneumatic connections 430 g 604 g Diameter 66 mm 90 mm Length below the gun 153 mm 180 mm Conveying air connection (FL) Supplementary air connection (ZL) red encoded / OptiFlex 2 CG09 connection 1.2 black / OptiFlex 2 CG09 connection 1.3 red encoded / OptiFlex 2 CG09 connection 1.2 black / OptiFlex 2 CG09 connection 1.3 OptiFlex GM03 application cup Technical data 9

Start-up and operation Connecting guide Note: The further start-up procedure for the OptiFlex 2 GM03 manual gun is explicitly described in the OptiFlex 2 CG09 control unit operating instructions (chapter "Initial start-up" and "Daily start up")! Gun Application Cup Filter unit Connecting guide - overview Note: The compressed air must be free from oil and water! OptiFlex GM03 application cup Start-up and operation 11

1. Connect the red quick release connection (with integrated powder stop) with the Quick release coupling of the conveying air hose. The conveying air hose must already be connected to the output 1.2 on the rear side of the control unit 2. Connect the black quick release connection (with integrated powder stop) with the Quick release coupling of the supplementary air hose. The supplementary air hose must already be connected to the output 1.3 on the rear side of the control unit 3. Connect pneumatic hoses according to color coding on the cup connection Function check 1. Turn on the gun control unit 2. Press the desired application key (Preset or Program mode) on the control unit (see gun control unit operating instructions) 3. Pick the gun up and point it at a grounded object, at a distance of approx. 20 cm 4. Press the powder gun trigger - The display for current and high voltage on the control unit shows the actual value. The high voltage is present in the OptiFlex 2 GM03 gun and the LED illuminates - The high voltage can be set with the corresponding keys (see also the control unit operating instructions) 5. Select the powder output and total air volume - The display indicates the powder output in % and total air volume in m³/h 6. Press the corresponding key for the rinsing air on the control unit (according to the used nozzle) 7. Check the remote control by pressing the + or - key on the back of the powder gun, and the modified powder output value is displayed on the control unit. By simultaneous pressing of the + and - key, the application modes can be changed on the control unit If all the checks are positive, the application cup is ready for operation. Note: If a malfunction occurs, see the troubleshooting guide, as well as the gun control operating instructions! 12 Start-up and operation OptiFlex GM03 application cup

Start-up Fill in powder 1. Fill the application cup with powder 2. Carefully place the dip tube into the powder, in order to avoid the clogging of the dip tube 3. Lock the bayonet closure Switch on the control unit 1. Press the ON power switch. The displays illuminate and the control unit is ready for operation 2. Select the coating parameters - The powder output can be adjusted either on the control unit or on the rear of the OptiFlex 2 GM03 powder gun (remote control) 3. Point the gun to the workpiece and coat normally OptiFlex GM03 application cup Start-up and operation 13

Maintenance and cleaning Note: Regular and conscientious maintenance increases the operating life of the unit and ensures a longer, more constant coating quality! Daily maintenance 1. Clean the application cup, see chapter "Cleaning" Weekly maintenance Cleaning 1. Clean the application cup, see chapter "Cleaning" 2. Check the O-rings Cleaning the application cup Frequent cleaning of the application cup helps to guarantee the coating quality. Note: Before cleaning the application cup, switch off the control unit. The compressed air used for cleaning must be free from oil and water! Attention: It is not permitted to clean the application cup with solvents! 1. Empty any powder out of the application cup 2. Clean the gun and the outside of the application cup by blowing off, wiping etc. 3. Release the bayonet closure between cup cover and cup 4. Clean the cup 5. Pull out the dip tube and clean it 6. Clean the cup with compressed air OptiFlex GM03 application cup Maintenance and cleaning 15

7. Clean the fluidizing plate with compressed air (free of oil and water) Attention: Do not clean the fluidizing plate with solvents or other fluidities! Completely dismantling the application cup Dismantling the application cup When changing colors (dark to light or vice versa), or for maintenance purposes, the entire application cup, including injector parts, can be dismantled and cleaned with compressed air. 1. Disconnect the pneumatic hoses 2. Unscrew the cup cover 3. Insert one of the pneumatic hoses into the connection tube and push out the injector parts (nozzle seat and nozzle) Attention: Do not use hard objects! 4. Clean the component parts with compressed air or by wiping Assembling the application cup The assembly of the application cup is carried out in the reverse order to that shown above. 16 Maintenance and cleaning OptiFlex GM03 application cup

Troubleshooting General information Fault Cause Troubleshooting No powder output The application cup is incorrectly connected or not connected at all to the control unit Injector nozzle clogged Dip tube clogged Check the pneumatic connections, and if necessary, connect (see Connection guide) Dismantle the application cup completely and clean it Blow through the dip tube with compressed air, and place it in the powder carefully Irregular powder output Poor leak proof closure Dismantle the application cup completely, check the O-rings and replace, if necessary Pneumatic hoses not correctly connected Powder fluidization insufficient or not available Check the elbow joints and connect correctly, if necessary. Dismantle and clean the fluidizing plate, replace if necessary OptiFlex GM03 application cup Troubleshooting 17

Spare parts list Ordering spare parts When ordering spare parts for powder coating equipment, please indicate the following specifications: - Type and serial number of your powder coating equipment - Order number, quantity and description of each spare part Example: - Type OptiFlex GM03 application cup Serial number 1234 5678 - Order no. 203 386, 1 piece, Clamp - Ø 18/15 mm When ordering cable or hose material, the required length must also be given. The spare part numbers of this yard/meter ware is always marked with an *. The wear parts are always marked with a #. All dimensions of plastic hoses are specified with the external and internal diameter: Example: Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d) WARNING! Only original Gema spare parts should be used, because the explosion protection will also be preserved that way. The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions! OptiFlex GM03 application cup Spare parts list 19

Application cup - spare parts list Application cup - 500 ml, complete 1002 069 A Cup - 500 ml, complete (incl. pos. 1, 2, 3) 1002 620 B Cup connection - 500 ml, complete (incl. pos. 6-14) 1002 094 1 Bottom 1002 074 2 Fluidizing plate 1002 072# 3 Cup cylinder - 500 ml 1002 070# 4 Dip tube - complete 1005 090# 5 O-ring - Ø 8x1 mm 221 740# 6 Cup cover 1002 098 7 O-ring - Ø 14x1.5 mm 263 486# 8 Nozzle 1002 097 9 O-ring - Ø 6x1 mm 217 115# 10 O-ring - Ø 10x1.5 mm 1002 588# 11 Nozzle seat 1002 096 12 Connection pipe 1002 095 13 O-ring - Ø 12x1.5 mm 1000 822# 14 Elbow joint - 1/8"a, Ø 6 mm 254 061 15 Pneumatic connection (from application cup to control unit) 1002 587 16 Coding ring, 06 red 1002 603 Application cup - 150 ml, complete 1004 552 C Cup - 150 ml, complete (incl. pos. 17, 18, 19) 1004 553 D Cup connection - 150 ml, complete (incl. pos. 7-14, 21) 1004 554 17 Bottom 1003 563 18 Fluidizing plate 1004 556# 19 Cup cylinder - 150 ml 1004 561# 20 Dip tube - complete 1005 089# 21 Cup cover 1003 564 # Wearing part 20 Spare parts list OptiFlex GM03 application cup

Application cup - spare parts 13 14 12 11 16 10 15 7 21 6 9 8 7 5 20 5 4 19 3 18 17 2 1 Application cup - spare parts OptiFlex GM03 application cup Spare parts list 21