Industrial flue gas probes. Instruction manual

Similar documents
High Pressure Abrasive Blast Cabinet 42000

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Modular Sample Gas Extraction System Probe Tubes Type 40, Type 42 Filter Units FE2, PFE2, PFE3. Operator s Manual 42/23-39 EN Rev.

ATM Lighting sp. z o.o

Installation and Operating Instructions Electric Vibrators HV/VFL Series

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

TIDALFLUX 2300 F Quick Start

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Cable thermocouple Model TC40

TESTO 350 Upgrades / Accessories / Spare Parts. Replacement Sensors

TEBS: Details for Installation / Storage / Maintenance

The PMI Dilution Probe for In-Situ Sample Conditioning of Stack Gases

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

testo Fine particle analyzer Instruction manual

A-320 Balanced 1st Stage

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

1.Safe testing IMPORTANT:

SPARK PLUG CLEANING KIT OPERATING MANUAL

Operating Manual. Automatic spray gun AGR-09 mini, AGR-09 mini with needle stroke limitation for low-pressure atomization

Operating Instructions

Visit us at

Tooling Assistance Center

AXIAL FANS Axis / Tubo OPERATION MANUAL

Turbocharger / TPS-H Original assembly instructions English

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

INSTRUCTION MANUAL ANGLE GRINDER PT W

RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

PE51 HURLEY 3 STATION METAL SWING SET OWNER'S MANUAL

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Visit us at

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

testo 108 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

Linear Luminaire for Fluorescent Lamps

Dual Remote Filtration System Installation and Servicing Instructions

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Turbocharger / A100-L Original assembly instructions English

These installation and maintenance instructions must be read in full and completely understood before the installation!

Power consumption In operation At rest For wire sizing

Cordless Rechargeable Saw Instructions for Use

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Visit us at

PREFACE. Dear customer,

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

PRESSURISED SANDBLASTER MODEL NO: CPSB100B PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Oil-free piston compressors KK and piston vacuum pumps KV

Diesel Cooker X 100. Installation Instructions

Data Sheet 10/ EN November 2004

250L Cartridge Dual Seal

Lumitester PD-20 Control Kit

PRODUCT MANUAL TILE CUTTING MACHINE. . Operation. Parts List and Diagram SPECIFICATIONS CAUTION:

Safety drying ovens. Advantages: Areas of application: FDL series 115

basic quattro No /

Short manual testo 610

Disassembly. 1 Pull off the QUIK-LOK cable from the machine.

Overview of types. Technical data. Safety notes

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

M-3025CB-AV Fuel Pump

Short manual testo 410-2

TABLE OF CONTENTS GENERAL INFORMATION

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o

Instructions for use and installation Cooker Hood

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

SERVICE MANUAL ULTIMATE 200

Operating Instructions Gasoline Hedge Trimmer. After Sales Support. TEL: WEB: BG-PH2250 N16188

ZE ZE ZE. Simplex expanding wedge brake Assembly and Maintenance Instructions

General safety and installation information.

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL

SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors

24 Volt - 3/8" Cordless Impact Wrench

Solenoid Operator 0516 / 1216

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

OPERATING MANUAL. Robot Gun Mount

PRESSURISED SANDBLASTER MODEL NO: CPSB200B

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

RAUTOOL G2 BATTERY HYDRAULIC TOOL KIT PRODUCT INSTRUCTIONS. Construction Automotive Industry

[1] [2] [1-1] [1-2] [1-7] [1-6] [1-3] [1-4] [1-5] [2-1] [2-2] [2-3] [2-7] [2-6] [2-4] [2-5]

HV Gate Valve with pneumatic actuator

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Fitting Instructions

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

SERVICE MANUAL. Permobil C350. Power Wheelchair

Guides, Brakes and Valves

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SOLAR CHARGE CONTROLLER

Type Pneumatic Control Unit. Operating Instructions

Transcription:

Industrial flue gas probes Instruction manual

2

1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment... 5 3 Specifications... 6 3.1. Use... 6 3.2. Technical data... 6 4 Product description... 11 5 Using the product... 14 6 Maintaining the product... 16 6.1. Checking / cleaning / replacing the particle filter... 16 6.2. Cleaning / replacing the preliminary filter... 19 6.3. Cleaning / replacing metal sampling tube... 21 6.4. Cleaning / replacing the ceramic tube... 22 6.5. Replacing unheated gas sampling hose... 23 6.6. Cleaning the gas path in the probe handle... 24 6.7. Replacing the thermocouple... 28 7 Tips and assistance... 31 7.1. Recommendations and application instructions... 31 7.2. Tightening torques for screw connections... 31 7.3. Accessories and spare parts... 32 3

2 Safety and the environment 2 Safety and the environment 2.1. About this document Use > Please read this documentation through carefully and familiarize yourself with the product before putting it to use. Pay particular attention to the safety instructions and warning advice in order to prevent injuries and damage to the products. > Keep this document to hand so that you can refer to it when necessary. > Hand this documentation on to any subsequent users of the product. 2.2. Ensure safety CAUTION Danger of burning on hot surfaces! > Always wear heat-resistant gloves when touching the probe shaft. > Allow the probe shaft to cool down after a measurement, before touching it or placing it in the transport packaging. > Only operate the product properly, for its intended purpose and within the parameters specified in the technical data. Do not use any force. > Temperatures given on probes/sensors relate only to the measuring range of the sensors. Do not expose handles and feed lines to any temperatures in excess of 70 C unless they are expressly permitted for higher temperatures. > Do not operate the instrument if there are signs of damage at the housing, mains unit or feed lines. > Do not perform contact measurements on non-insulated, live parts. > Do not store the product together with solvents. Do not use any desiccants. > Only perform maintenance and repair work on this instrument that is described in the documentation. Follow the prescribed steps exactly. Use only original spare parts from Testo. 4

2 Safety and the environment > Any additional work must only be carried out by authorized personnel. Testo will otherwise refuse to accept responsibility for the proper functioning of the measuring instrument after repair and for the validity of certifications. > The industrial flue gas probe must not be used in explosive environments. > When connecting the heated industrial flue gas probe, ensure correct mains voltage as specified on the type plate. > Before opening the probe housing of the heated industrial flue gas probe, pull out the mains plug. Safety-related symbols on heated industrial flue gas probes Symbol Explanation If the product is not used in strict compliance with this documentation, the intended protection may be impaired. > Operate the product only as described in this documentation. > Please consult your dealer or the manufacturer if in doubt. Risk of burns due to hot surface. Use heat-resistant gloves for protection against harmful thermal effects. 2.3. Protecting the environment > At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. 5

3 Specifications 3 Specifications 3.1. Use The industrial flue gas probes have been designed for the following tasks / applications: Extractive sampling of the flue gas being analyzed at industrial plants with high temperatures of > 1000 C large sampling diameters wet flue gas to prevent distorted readings (heated industrial flue gas probe up to 600 C) The industrial flue gas probes are used in conjunction with the following flue gas analyzers: testo 340 testo 350 The industrial flue gas probes come in two pre-configured sets. A system-specific sampling solution can be put together using other accessories. 3.2. Technical data General Feature Overpressure in the flue gas Negative pressure in the flue gas Values max. 100 mbar testo 340: max. 200 mbar testo 350: max. 300 mbar Ambient temperature -5 to +45 C Storage temperature -20 to +50 C 6

3 Specifications Unheated handle (item no. 0440 0649) Feature Values Temperature resistance 600 C Handle - probe shaft connection Handle - thermocouple connection Hose connection Internal thread G 1/4 Internal thread M8 x 1 Adapter with hose nozzle, 7 mm outer diameter Material Stainless steel 1,4404 Unheated gas sampling hose (item no. 0554 3354) Feature Length Design Particle filter Values 4000 mm 2-chamber hose with Teflon inner hose To protect the measuring instrument from particulate matter and dirt Material: PE porous 10 µm Unheated sampling tube up to 1200 C (item no. 0600 7617) Feature Values Temperature resistance 1200 C Dimensions Length 1053 mm, Probe shaft: Ø 12 mm, Threaded socket: Ø 17 mm Connection Thread G 1/4 Material 2.4856 alloy 625 Option Probe extension (extension tube item no. 0600 7617) Probe preliminary filter (item no. 0600 7616) can be attached 7

3 Specifications Unheated sampling tube up to 1800 C (item no. 0600 7805) Feature Values Temperature resistance 1800 C Dimensions Handle Ø 12 mm, length 1000 mm Adapter with O-ring, Tmax: 220 C; Ø 22 mm Material Ceramic Al 2O 3 >99.7% Thermocouple (item no. 0430 0088) Feature Values Temperature recorder Type K NiCr-Ni, insulated Class 1 Sheathed cable 2.4816 alloy 600 Length TC Diameter 1200 mm; optional length 2200 mm (item no. 0600 7615) available 2 mm Measuring range -200 to +1200 C Cable length 4.0 m Heated sampling tube (item no. 0600 3502) Feature Values Temperature resistance up to 600 C Voltage supply Power consumption Dimensions Ready for operation 230 V/50 Hz 400 W Ø 25 mm, length: 1110 mm within 15 min. Heating temperature >180 C Option Probe extension (extension tube) (item no. 0600 7617) Probe preliminary filter (item no. 0600 7616) can be attached 8

3 Specifications Heated gas sampling hose (item no. 0600 3501) Feature Design Dimensions Heating temperature range Ready for operation Values Corrugated hose with Teflon inner hose Length: 4000 mm Corrugated hose: Ø 28 mm Silicone caps: Ø 34 mm >120 C within 15 min. Outside temperature max. +45 C Voltage supply 230 V/50 Hz Power consumption 160 W Bending radius min. 200 mm Preliminary filter (item no. 0600 7616) Feature Values Operating temperature max. 1000 C Dimensions Ø 30 mm, length 110 mm Filter seat Material:1.4841 Connecting thread: G 1/4 Filter nut Material: 1.4841 Thread: G 1/4 Filter element Dimensions: Ø 30 mm, length 75 mm Material: porous silicon carbide Particle size: 10 μm Filtration grade for 2 μm gases Safety cotter pin DIN 94, dimensions: 2.0 x 16 mm, Material: stainless steel A4 9

3 Specifications Warranty Feature Thermocouple Heated sampling tube Heated hose Sampling / extension tube Unheated hose Unheated handle Warranty terms Values 12 months 24 months 24 months 24 months 24 months 24 months see website www.testo.com/warranty 10

4 Product description 4 Product description Industrial flue gas probe set 1200 C (0600 7610) 1 Unheated handle 2 Unheated metal sampling tube 3 Preliminary filter (optional) 4 Instrument connections 5 Unheated gas sampling hose 6 Particle filter 7 Thermocouple type K 8 Gas path 11

4 Product description Industrial flue gas probe set 1.800 C (0600 7620) 1 Unheated handle 2 Unheated ceramic sampling tube 3 Unheated gas sampling hose 4 Instrument connection 5 Particle filter 6 Gas path 12

4 Product description Industrial flue gas probe set, heated (0600 7630) 1 Heated sampling tube 2 Preliminary filter (optional) 3 Heated gas sampling hose 4 Instrument connection 5 Probe heater connection cable 6 Probe heater 7 Thermocouple type K 13

5 Using the product 5 Using the product Heated industrial flue gas probe > The heated industrial flue gas probe is designed for a mains voltage of 230 V! > Uncoil the coiled gas sampling hose correctly so that there is no torsional strain. > Lay the gas sampling hose so that it is protected from the wind and the weather, because depending on the wind/weather conditions, there is considerable loss of heat at the outer sheath. > When installing in closed rooms please ensure that there is sufficient ventilation to prevent heat build-up. > To prevent damage Do not route the gas sampling hose over sharp edges or via feedthroughs. When securing, make sure that the gas sampling hose is not squashed. There should be no moving or bending stresses on the connections themselves. When installing, please ensure a minimum bending radius of 200 mm. > Following final installation, visually inspect the heated industrial flue gas probe for any damage. > After the mains plug has been plugged in, the total heating up time is approx. 20 minutes. > Once the heating up time has elapsed, the heated sampling tube is very hot and should only be touched with heat-resistant gloves. CAUTION Danger of burning on hot surfaces! > Always wear heat-resistant gloves when touching the probe shaft. > Allow the probe shaft to cool down after a measurement, before touching it or placing it in the transport packaging. 14

5 Using the product Checking the thermocouple > Make sure that the thermocouple of the industrial flue gas probe does not touch the probe shaft. Bend the thermocouple back if necessary. Aligning the industrial flue gas probe > Align the industrial flue gas probe in the flue gas duct so that the tip is in the centre of flow (area of the highest flue gas temperature). Optional - Mount extension tube. - Mount preliminary filter. - Install thermocouple 2200 mm. 15

6 Maintaining the product 6 Maintaining the product 6.1. Checking / cleaning / replacing the particle filter Checking the particle filter: Check the particle filter of the industrial flue gas probe regularly for Damage to and contamination of the housing Filter saturation of the PE filter Visual inspection Cleaning the particle filter housing: > If there are any signs of contamination, clean the particle filter housing. 1. Open the filter cover of the housing 2. Remove dirt using a cloth. 3. Put the filter cover on and lock it: turn slightly clockwise 16

6 Maintaining the product Replacing the particle filter housing: > In the event of any damage to the housing, replace the particle filter (item no. 0440 0668). 1. Remove bend protection springs and hose connections from the particle filter by turning clockwise. 2. Attach new particle filter to the hose connections. If the saturation level is low, the PE filter can be inserted in the new housing. 3. Push the bend protection springs over the hose connections by pressing and simultaneously turning clockwise. Checking the PE filter: Check the particle filter of the industrial flue gas probe regularly for filter saturation. Carry out a test. - Measuring instrument is switched on. > Remove bend protection spring and hose connection from the particle filter by turning clockwise. 17

6 Maintaining the product - The measurement gas pump now sucks in ambient air via the filter. Filter needs replacing if: Flow rate < 0.6 l/min testo 350 Flow rate < 0.2 l/min testo 340 If the flow rate value is >0.6 l/min (testo 350) or > 0.2 l/min (testo 340), the particle filter is not yet saturated. We recommend checking the handle, the preliminary filter and the sampling tube. Replacing the PE filter: > If the PE filter is visibly saturated: replace the PE filter. 1. Open the filter cover of the housing 2. Remove the spent PE filter. 3. Insert new PE filter. Insert the PE filter into the filter holder as far as it will go. 4. Put the filter cover on and lock it: turn slightly clockwise. 18

6 Maintaining the product 6.2. Cleaning / replacing the preliminary filter Check the preliminary filter of the industrial flue gas probe regularly for contamination: visual inspection > In the event of any visible contamination, clean or replace the preliminary filter. 1. Fix the sampling tube securely in place. 2. Press the ends of the safety cotter pin together with pliers and slide upwards. 3. Remove safety cotter pin. 4. Remove the preliminary filter (size SW17) from the sampling tube (size SW13) using wrenches. 19

6 Maintaining the product 5. Open preliminary filter using wrenches (size SW17). 6. Remove screw connections from the preliminary filter. 7. Clean the preliminary filter. ATTENTION Do not clean preliminary filter in liquids or ultrasonically. Damage due to improper cleaning! > Soot or particle deposits on the preliminary filter can be brushed off using a wire brush. Then blow compressed air through the preliminary filter. 8. Put together, screw together and tighten the cleaned or new preliminary filter and insert safety cotter pin, see Tightening torques for screw connections, page 31. 9. Tighten the preliminary filter (size SW17) on the sampling tube (size SW13) using wrenches, see Tightening torques for screw connections, page 31. 10. Disengage the sampling tube. 20

6 Maintaining the product 6.3. Cleaning / replacing metal sampling tube Check the sampling tube of the industrial flue gas probe regularly for contamination: visual inspection > In the event of any visible contamination, clean or replace the sampling tube. CAUTION Hot probe shaft! Risk of burns! > Allow the probe shaft to cool down before you touch or pack it! 1. Fix the sampling tube securely in place. 2. Remove the sampling tube (size SW13) from the handle (size SW19) using wrenches. If necessary remove preliminary filter from the sampling tube. 3. Cleaning the sampling tube > Brush off soot or particle deposits on the sampling tube using a wire brush. > Scrape out the inside of the sampling tube using a sturdy wire (e.g. Ø 3 mm). Hold the tube at a slight angle, so that the dislodged particles fall out. > Then blow compressed air through the sampling tube. 21

6 Maintaining the product 4. Screw cleaned or new sampling tube onto the handle and tighten, see Tightening torques for screw connections, page 31. If necessary screw preliminary filter onto the sampling tube. 5. Disengage the sampling tube. 6.4. Cleaning / replacing the ceramic tube Check the sampling tube of the industrial flue gas probe regularly for contamination: visual inspection > In the event of any visible contamination, clean or replace the sampling tube. CAUTION Hot probe shaft! Risk of burns! > Allow the probe shaft to cool down before you touch or pack it! CAUTION Fragile ceramic sampling tube! > Avoid mechanical loads. 1. Remove sampling tube from the handle. 2. Cleaning the sampling tube > Scrape out the inside of the sampling tube using a sturdy wire (e.g. Ø 3 mm). Hold the tube at a slight angle, so that the dislodged particles fall out. > Then blow compressed air through the sampling tube. 3. Check handle - If the O-ring in the handle is damaged, the handle must be replaced. 4. Insert a cleaned or new sampling tube into the handle as far as it will go. 22

6 Maintaining the product 6.5. Replacing unheated gas sampling hose Check the unheated gas sampling hose of the industrial flue gas probe regularly for damage and contamination: visual inspection Replacing the gas sampling hose 1. Undo all hose clamps on the gas sampling hose. 2. Remove all bend protection springs from the hose connections and the thermocouple clamping screw by turning clockwise. 3. Remove hose connections from the particle filter, gas path connection and gas path plug by turning clockwise. 4. Remove bend protection springs from the hose connections. 5. Undo the thermocouple clamping screw connection. 6. Pull the thermocouple approx. 100 mm out of the probe handle. 7. Push bend protection spring over the thermocouple. 8. Remove the thermocouple cable, starting at the instrument plug, from the slotted tube. 9. Insert the thermocouple cable, starting at the instrument plug, into the slotted tube of the new gas sampling hose. 10. Push the bend protection spring over the slotted tube. 23

6 Maintaining the product 11. Carefully thread the thermocouple up to 50 mm through the clamping screw and the probe handle into the probe shaft. 12. Tighten clamping screw using a wrench (size SW8), with 1 3/4 turns. When refitting the same clamping screw, this is tightened with a 1/4 turn more. 13. Push bend protection springs over the clamping screw. 14. Attach bend protection springs to the hose connections for the particle filter, gas path connection and gas path plug. 15. Connect the particle filter, gas path connection and gas path plug to the hose connections. 16. Push the bend protection springs over the hose connections by pressing and simultaneously turning clockwise. 17. Fasten hose clamps to the gas sampling hose. 6.6. Cleaning the gas path in the probe handle Check the gas path in the handle regularly for contamination. 1. Fix sampling tube and handle securely in place. 2. Remove the sampling tube (size SW13) from the handle (size SW19) using wrenches. 24

6 Maintaining the product 3. Undo upper hose clamp. 4. Remove bend protection springs from the thermocouple clamping screw. 5. Undo the thermocouple clamping screw using a wrench (size SW8). 6. Carefully pull out thermocouple. 25

6 Maintaining the product ATTENTION Never pull on the connection cable when removing the thermocouple from the handle. Damage due to inappropriate handling! > Hold thermocouple tightly in front of the ferrule and carefully pull it out of the handle. 7. Undo the clamping screw connection using a wrench (size SW12). 8. Remove bend protection spring and gas path hose at the gas path connection by turning clockwise. 26

6 Maintaining the product 9. Insert the cleaning brush into the probe handle. 10. Push the cleaning brush through to the tip of the probe handle and pull out. 11. Repeat steps 9 and 10 several times depending on the degree of contamination. 12. Clean gas path connection. 13. Repeat step 11 several times depending on the degree of contamination. 14. Attach hose to the gas path connection and push bend protection springs over the gas path connection by pressing and turning clockwise simultaneously. 15. Tighten clamping screw connection on the probe handle using a wrench (size SW12), see Tightening torques for screw connections, page 31. 16. Screw clamping screw on the clamping screw connection by hand as far as it will go. 27

6 Maintaining the product 17. Carefully thread the thermocouple up to 50 mm through the clamping screw and the probe handle and into the probe shaft. 18. Tighten clamping screw using a wrench (size SW8), with 1 3/4 turns. When refitting the same clamping screw, this is tightened with a 1/4 turn more. 19. Push bend protection springs over the clamping screw. 20. Fasten upper hose clamp to the gas sampling hose. 21. Screw sampling tube onto the handle and tighten, see Tightening torques for screw connections, page 31. 6.7. Replacing the thermocouple Before replacing the thermocouple, disconnect the industrial flue gas probe from the Testo measuring instrument. 1. Undo all hose clamps on the gas sampling hose. 28 2. Remove bend protection springs from the thermocouple clamping screw.

6 Maintaining the product 3. Undo the thermocouple clamping screw using a wrench (size SW8). 4. Carefully pull out thermocouple. 5. Remove the thermocouple cable, starting at the instrument plug, from the slotted tube. 29

6 Maintaining the product ATTENTION Never pull on the connection cable when removing the thermocouple from the handle. Damage due to inappropriate handling! > Hold thermocouple tightly in front of the ferrule and carefully pull it out of the handle. 6. Remove bend protection spring from the thermocouple. 7. Attach bend protection spring to the new thermocouple. 8. Insert the new thermocouple cable, starting at the instrument plug, into the slotted tube. 9. Push the bend protection spring over the tube. 10. Carefully thread the new thermocouple up to 50 mm through the clamping screw and the probe handle into the probe shaft. 11. Screw the clamping screw by hand as far as it will go. Then tighten using a wrench (size SW8) with 1 3/4 turns. When refitting the same clamping screw, this is tightened with a 1/4 turn more. 12. Carefully bend thermocouple 90 between ferrule and clamping screw connection. Do not kink the thermocouple. 13. Push bend protection springs over the clamping screw. 14. Fasten hose clamps to the gas sampling hose. 30

7 Tips and assistance 7 Tips and assistance 7.1. Recommendations and application instructions Application / problem The screw connections are difficult to undo following usage at high temperatures (>600 C). In the event of heavy dust loads (e.g. measurement on a rotary kiln), the particle filter gets clogged very quickly. A filter cake forms on the probe shaft tip during measurement. Recommendation / solution Grease the threads of the screw connections with a standard ceramic paste before use. To achieve a longer service life, replace the particle filter with a standard fuel filter. The measurement period can last 10 to 20 min as a result. The filter cake can be knocked off either straight after measurement or once the cooling time has elapsed. If we have not been able to answer your question, please contact your dealer or Testo Customer Service. For contact details, see the back of this document or visit the website www.testo.com/servicecontact. 7.2. Tightening torques for screw connections Screw connections Tightening torque Handle - probe shaft Probe shaft - probe shaft Handle - gas path hose adapter Handle - TC clamping screw connection Probe shaft - preliminary filter Preliminary filter: Filter nut - Filter seat 20 Nm 20 Nm 6 Nm 10 Nm 20 Nm 2 Nm 31

7 Tips and assistance 7.3. Accessories and spare parts Description Item no. Probe preliminary filter for dusty/dirty flue gases 0600 7616 Extension/sampling tube, length 1000 mm, up to max. 1200 C 0600 7617 Transport case for flue gas probes 0516 7600 Thermocouple, length 2200 mm, up to max. 1200 C 0600 7615 Particle filter (housing incl. PE filter) 0440 0668 PE filter (10 pcs.) 0554 3371 Unheated probe handle 0440 0649 Spare thermocouple 1200 mm 0430 0088 Seal ring for thermocouple, stainless steel 0170 0474 Clamping screw connection for thermocouple 0400 0083 Unheated gas sampling hose 0554 3354 Spare filter element 0133 0043 Replacement ceramic sampling tube 1.800 C 0440 0669 Adapter for ceramic sampling tube 0190 0186 O-ring for adapter 0135 0312 32

0970 0394 en 03