ABB string inverters PVI-5000/6000-TL-OUTD 5 to 6 kw

Similar documents
ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB central inverters PVS to 2091 kva

SOLAR INVERTERS. Solar inverter solutions for building applications Helping you get more energy out of every day

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

OGUE 2013 ATAL WIND C

ABB central inverters PVS to 2091 kva

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

ABB central inverters ULTRA-750/1100/ kW to 1560kW

ABB solar inverters. Product manual REACT-3.6/4.6-TL (from 3.6 to 4.6 kw)

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

ABB central inverters PVS to 1000 kw

Features MICRO-0.25-I MICRO-0.3-I PRODUCTS PANEL

ABB central inverters PVS to 2000 kva

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

ABB central inverters PVS to 1000 kw

SolarMax P series The power package for residential solar plants

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Sunny Tripower CORE1.

String Inverter (SUN KTL-A)

There s a new power in Solar 1500V ultra-high power string inverters for utility-scale PV applications

SolarMax MT series The all-rounder for trade and industry

SolarMax MT series. The power pack for maximum yields.

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Energy Storage System for Home

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

Pre-announcement. Transformerless Solar Inverters

Residential Energy Storage System SH 5K

PQstorI One stop solution for energy storage and power quality

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

Solar Energy Solutions Product Catalogue

SolarMax MT A series A reliable solution for commercial PV applications

24 HOURS OF SUN IS POSSIBLE. NOW THAT RENEWABLE ENERGY IS ACCESSIBLE ALL AROUND THE CLOCK. / Solar Energy Services and product programme 2014/15

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

Photovoltaics. MPI Hybrid Series

INDEPENDENCE IS POSSIBLE. BECAUSE WE MAKE SOLAR POWER AVAILABLE DAY AND NIGHT. / Solar Energy Services and product programme 2015/16

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

Residential Energy Storage System SH5K PV ESS

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

Power Conversion System The Best Technology for your photovoltaic and storage system

+86(571) (571) (V4)

/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A

3 Phase Power Systems - Designed for Canada

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

PVS-100/120-TL The largest 1000Vdc string inverter in the solar industry

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

Conext CL. The ideal solution for commercial buildings carports, and decentralized power plants. solar.schneider-electric.com

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

FRONIUS ENERGY PACKAGE

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

SUNNY TRIPOWER CORE1 - STP 50-40

MERU Solar Off-Grid Inverters

All-in-one Storage Hybrid System

ABB solar inverters Product portfolio

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

Green Inverter from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

PQactiF Higher flexibility and modularity for improved power quality

Power Whenever You Need

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Mini contactors B6, BC6 with 3 pole

COMPANY INTRODUCTION COMPANY MISSION COMPANY VISION

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Harnessing Solar Power for greener earth and better tomorrow. Renewable Energy for Business-Critical Continuity TM

500 / 630 / 720 / 760 / 800 / 850 / 900

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

HUAWEI Smart PV Plant Solutions

Low Voltage Systems MNS and MNS is PowerCenter

Data sheet. PIKO MP plus

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

GS1500i V central solar inverter. INDUSTRIAL SOLUTIONS

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Catch Eco Range : Technical Specification Sheet

SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor.

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Re-defining the utility-scale inverter

EAS822 (Contrac) Power Electronic Unit

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

photovoltaikforum.com

Technical Specification SENTINEL PRO

Transcription:

SOLAR INVERTERS ABB string inverters PVI5000/6000TLOUTD 5 to 6 kw Designed for residential and small commercial photovoltaic installations, this inverter fills a specific niche in the product line to cater for those installations producing between 5kW and 20kW. 01 01 PVI5000/6000TLOUTD outdoor string inverter This inverter has a dual input section to process two strings with independent Maximum Power Point Tracking (MPPT), high speed and precise MPPT algorithm for realtime power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.0%. Suitable for low power installations with reduced string size The wide input voltage range makes the inverter suitable for low power installations with reduced string size. Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. Highlights Singlephase output Transformerless topology Each inverter is set on specific grid codes which can be selected in the field Dual input section with independent MPPT, allows optimal energy harvesting from two subarrays oriented in different directions Wide input voltage range Natural convection cooling for maximum reliability Outdoor enclosure for unrestricted use under any environmental conditions RS485 communication interface (for connection to laptop or datalogger) This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

PRODUCT FLYER FOR PVI5000/6000TLOUTD ABB SOLAR INVERTERS ABB string inverters PVI5000/6000TLOUTD 5 to 6 kw Type code PVI5000TLOUTD PVI6000TLOUTD Input side Absolute maximum DC input voltage (Vmax,abs) 600 V Startup DC input voltage (Vstart) 200 V (adj. 120...350 V) Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x Vstart...580 V (min 90 V) Rated DC input voltage (Vdcr) 360 V Rated DC input power (Pdcr) 5150 W 6200 W Number of independent MPPT 2 Maximum DC input power for each MPPT (PMPPTmax) 4000 W DC input voltage range with parallel configuration of MPPT at Pacr 150...530 V 180...530 V DC power limitation with parallel configuration of MPPT Linear derating from max to null [530 V VMPPT 580 V] DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 4000 W [220 V VMPPT 530 V] the other channel: Pdcr4000 W [90 V VMPPT 530 V] 36.0 A / 18.0 A 4000 W [220 V VMPPT 530 V] the other channel: Pdcr4000 W [120 V VMPPT 530 V] Maximum input short circuit current for each MPPT 22.0 A Number of DC input pairs for each MPPT 2 DC connection type PV quick fit connector 3) Input protection Reverse polarity protection Yes, from limited current source Input over voltage protection for each MPPT varistor Yes Photovoltaic array isolation control DC switch rating for each MPPT (version with DC switch) 25 A / 600 V Output side AC grid connection type Singlephase Rated AC power (Pacr @cosφ=1 ) 5000 W 4) 6000 W Rated AC power (Pacr @cosφ=±0.9) 5000 W 4) 6000 W Maximum AC output power (Pacmax @cosφ=1) 5000 W 4) 6000 W Maximum apparent power (Smax) 5560 VA 6670 VA Rated AC grid voltage (Vac,r) 230 V AC voltage range 180...264 V 1) Maximum AC output current (Iac,max) 25.0 A 30.0 A Contributory fault current 32.0 A 40.0 A Rated output frequency (fr) 50 Hz / 60 Hz Output frequency range (fmin...fmax) 47...53 Hz / 57 63 Hz 2) Nominal power factor and adjustable range > 0.995, adj. 0.8 inductive to 0.8 capacitive Total current harmonic distortion < 3.5% AC connection type Terminal block, cable gland M32 Output protection Antiislanding protection Maximum external AC overcurrent protection 32.0 A 40.0 A Output overvoltage protection varistor 2 (L N / L PE) Operating performance Maximum efficiency (ηmax) 97.0% Weighted efficiency (EURO/CEC).4% / Feed in power threshold 10.0 W Night consumption < 0.4 W

PRODUCT FLYER FOR PVI5000/6000TLOUTD ABB SOLAR INVERTERS ABB PVI5000/6000TLOUTD string inverter block diagram.1().2().1().2() MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC).1().2().1().2() Line filter Grid parallel relay L N IN2.1() IN2.2() IN2.1() IN2.2() MPPT 2 (DC/DC) PE IN2 IN2 IN2 Residual current detection IN2.1() IN2.2() IN2.1() IN2.2() RS485 Standard version S version T/R T/R RTN DC/DC DSP contr. µp DC/AC DSP contr. Remote control Alarm R R N.C N.O C Control circuit Type code PVI5000TLOUTD PVI6000TLOUTD Communication Wired local monitoring Remote monitoring Wireless local monitoring User interface Environmental PVIUSBRS232_485 (opt.) VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) VSN300 Wifi Logger Card (opt.) 16 characters x 2 lines LCD display Ambient temperature range 25...60 C (13... 140 F) 25...60 C (13... 140 F) with derating above 50 C (122 F) Relative humidity 0...100% condensing Sound pressure level, typical 50 dba @ 1 m Maximum operating altitude without derating 2000 m / 6560 ft Physical Environmental protection rating IP65 Cooling Natural Dimension (H x W x D) 810 mm x 325 mm x 222 mm / 31.9 x 12.8 x 8.7 Weight < 26.0 kg / 57.3 lbs Mounting system Wall bracket Safety Isolation level Transformerless Marking CE (50 Hz only), RCM Safety and EMC standard EN 50178, IEC/EN 6210, IEC/EN 621092, AS/NZS 3100, EN 6100061, EN 6100063, EN 61000311, EN 61000312 Grid standard (check your sales channel for availability) CEI 021, DIN V VDE V 012611, G59/3, EN 50438 (not for all national appendices), RD 1699, RD 413, ITCBT40, AS 4777, C10/11, IEC 61727, IEC 62116 Available products variants Standard PVI5000TLOUTD PVI6000TLOUTD With DC switch PVI5000TLOUTDS PVI6000TLOUTDS 1) The AC voltage range may vary depending on specific country grid standard 2) The Frequency range may vary depending on specific country grid standard 3) Please refer to the document String inverters Product manual appendix available at www.abb.com/solarinverters for information on the quickfit connector brand and model used in the inverter 4) 4600 W for Australia Remark. Features not specifically listed in the present data sheet are not included in the product

Efficiency curves of PVI5000TLOUTD Efficiency curves of PVI6000TLOUTD 100 100 99 99 99 99 98 98 98 98 97 97 97 97 Efficiency Efficiency [%] [%] 95 95 94 94 Efficiency [%] Efficiency [%] 95 95 94 94 93 93 93 93 92 92 250 Vdc 300 Vdc 360 Vdc 580 Vdc 480 Vdc 750 Vdc 92 92 250 Vdc 360 Vdc 360 Vdc 580 Vdc 480 Vdc 750 Vdc 90 900% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of of Rated rated Output Power 90 900% 0% 10% 10% 20% 20% 30% 30% 40% 40% 50% 50% 60% 60% 70% 70% 80% 80% 90% 90% 100% 100% % of % Rated of rated Output Power For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved BCD.00375_EN REV G 03.05.2017

SOLAR INVERTERS ABB string inverters PVI3.0/3.6/4.2TLOUTD 3.6 to 4.2 kw ABB s UNO family of singlephase string inverters complements the typical number of rooftop solar panels, allowing home owners to get the most efficient energy harvesting for the size of the property. 01 01 PVI3.0/3.6/4.2TLOUTD outdoor string inverter The dual input section processes two strings with independent Maximum Power Point Tracking (MPPT). This is particularly useful for rooftop installations with two different orientations (e.g. East and West). The high speed MPPT offers realtime power tracking and improved energy harvesting. Efficiency of up to.8% The transformerless (TL) operation gives the highest efficiency of up to.8%. The wide input voltage range makes the inverter suitable for low power installations with reduced string size. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. Our most common residential inverter is the ideal size for an averagesized family home. Highlights Singlephase output Transformerless topology Each inverter is set on specific grid codes which can be selected in the field Wide input voltage range High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Dual input section with independent MPPT, allows optimal energy harvesting from two subarrays Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Integrated DC disconnect switch in compliance with international standards (S version) Natural convection cooling for maximum reliability Outdoor enclosure for unrestricted use under any environmental conditions RS485 communication interface (for connection to laptop or datalogger)

PRODUCT FLYER FOR PVI3.0/3.6/4.2TLOUTD ABB SOLAR INVERTERS ABB string inverters PVI3.0/3.6/4.2TLOUTD 3.6 to 4.2 kw Type code PVI3.0TLOUTD PVI3.6TLOUTD PVI4.2TLOUTD Input side Absolute maximum DC input voltage (Vmax,abs) 600 V Startup DC input voltage (Vstart) 200 V (adj. 120...350 V) Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x Vstart...580 V (min 90 V) Rated DC input voltage (Vdcr) 360 V Rated DC input power (Pdcr) 3120 W 3750 W 4375 W Number of independent MPPT 2 Maximum DC input power for each MPPT (PMPPTmax) 2000 W 3000 W 3000 W DC input voltage range with parallel configuration of MPPT at Pacr 160...530 V 120...530 V 140...530 V DC power limitation with parallel configuration of MPPT Linear derating from max to null [530 V VMPPT 580 V] DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 2000 W [200 V VMPPT 530 V] the other channel: Pdcr2000 W [112 V VMPPT 530 V] 3000 W [190 V VMPPT 530 V] the other channel: Pdcr3000 W [90 V VMPPT 530 V] 20.0 A / 10.0 A 32.0 A / 16.0 A Maximum input short circuit current for each MPPT 12.5 A 20.0 A Number of DC input pairs for each MPPT 1 1 1 DC connection type PV quick fit connector 3) Input protection Reverse polarity protection Yes, from limited current source Input over voltage protection for each MPPT varistor Yes Photovoltaic array isolation control DC switch rating for each MPPT (version with DC switch) 25 A / 600 V Output side AC grid connection type Singlephase Rated AC power (Pacr @cosφ=1) 3000 W 3600 W 4200 W Rated AC power (Pacr @cosφ=±0.9) 3000 W 3600 W 4200 W Maximum AC output power (Pacmax @cosφ=1) 3300 W 5) 4000 W 6) 4600 W 7) Maximum apparent power (Smax) 3330 VA 4000 VA 4670 VA Rated AC grid voltage (Vac,r) 230 V AC voltage range 180...264 V 1) Maximum AC output current (Iac,max) 14.5 A 17.2 A 2) 20.0 A Contributory fault current 16.0 A 19.0 A 22.0 A Rated output frequency (fr) 50 Hz / 60 Hz Output frequency range (fmin...fmax) 47...53 Hz / 57 63 Hz 4) Nominal power factor and adjustable range > 0.995, adj. 0.8 inductive to 0.8 capacitive Total current harmonic distortion < 3.5% AC connection type Screw terminal block, cable gland M25 Output protection Antiislanding protection Maximum external AC overcurrent protection 20.0 A 25.0 A 25.0 A Output overvoltage protection varistor 2 (L N / L PE) Operating performance Maximum efficiency (ηmax).8% Weighted efficiency (EURO/CEC).0% / Feed in power threshold 10.0 W Night consumption < 0.4 W

PRODUCT FLYER FOR PVI3.0/3.6/4.2TLOUTD ABB SOLAR INVERTERS ABB PVI3.0/3.6/4.2TLOUTD string inverter block diagram.1().1() MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC).1().1() Line filter Grid parallel relay L N IN2.1()* IN2.1()* MPPT 2 (DC/DC) PE IN2 IN2 IN2 IN2.1()* IN2.1()* Residual current detection RS485 Standard version S version T/R T/R RTN (*)Not available in PVI3.0TLOUTD DC/DC DSP contr. µp DC/AC DSP contr. Remote Control Alarm R R N.C N.O C Control circuit Type code PVI3.0TLOUTD PVI3.6TLOUTD PVI4.2TLOUTD Communication Wired local monitoring Remote monitoring Wireless local monitoring User interface Environmental Ambient temperature range Relative humidity Sound pressure level, typical Maximum operating altitude without derating Physical Environmental protection rating Cooling PVIUSBRS232_485 (opt.) VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) VSN300 Wifi Logger Card (opt.) 16 characters x 2 lines LCD display 25...60 C /13...140 F with derating above 50 C/122 F 25...60 C /13...140 F with derating above 55 C/131 F 0...100% condensing 50 dba @ 1 m 2000 m / 6560 ft IP65 Natural 25...60 C /13...140 F with derating above 50 C/122 F Dimension (H x W x D) 618 mm x 325 mm x 222 mm / 24.3 x 12.8 x 8.7 Weight 17.5 kg / 38.5 lbs Mounting system Wall bracket Safety Isolation level Transformerless Marking CE (50 Hz only), RCM Safety and EMC standard EN 50178, IEC/EN 6210, IEC/EN 621092, AS/NZS 3100, EN 6100061, EN 6100063, EN 61000311, EN 61000312 Grid standard (check your sales channel for availability) CEI 021, DIN V VDE V 012611, VDEARN 4105, G83/2, G59/3, EN 50438 (not for all national appendices), RD 1699, RD 413, ITCBT40, AS 4777, IEC 61727, IEC 62116 Available products variants Standard PVI3.0TLOUTD PVI3.6TLOUTD PVI4.2TLOUTD With DC switch PVI3.0TLOUTDS PVI3.6TLOUTDS PVI4.2TLOUTDS 1) The AC voltage range may vary depending on specific country grid standard 2) For UK G83/2 setting, maximum output current limited to 16A up to a maximum output power of 3.68 kw 3) Please refer to the document String inverters Product manual appendix available at www.abb.com/solarinverters for information on the quickfit connector brand and model used in the inverter 4) The Frequency range may vary depending on specific country grid standard 5) Limited to 3000 W for Germany 6) Limited to 3600 W for Germany 7) Limited to 4200 W for Germany Remark. Features not specifically listed in the present data sheet are not included in the product

Efficiency curves of PVI3.0TLOUTD Efficiency curves of PVI4.2TLOUTD 99 99 98 99 9899 97 98 97 98 97 95 9597 94 94 Efficiency [%] [%] 93 95 92 94 90 Efficiency [%] Efficiency [%] 93 9295 94 90 89 93 8993 88 92 87 300 200 Vdc Vdc 360 Vdc 580 Vdc 88 92 87 215 Vdc 360 Vdc 360 Vdc 580 Vdc 86 480 Vdc 750 Vdc 86 480 Vdc 750 Vdc 85 90 0% 0% 10% 10% 20% 20% 30% 30% 40% 50% 50% 60% 60% 70% 70% 80% 80% 90% 90% 100% 100% % of rated Output Power 85 90 0% 0% 10% 10% 20% 20% 30% 30% 40% 40% 50% 50% 60% 60% 70% 70% 80% 80% 90% 90% 100% 100% % of of rated rated Output Output Power Power For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved BCD.00374_EN REV G 08.05.2017

SOLAR INVERTERS ABB string inverters TRIO5.8/7.5/8.5TLOUTD 5.8 to 8.5 kw The allinone residential threephase TRIO5.8, 7.5 and 8.5 kw inverters deliver performance, ease of use and installation, monitoring and control. With their 98% peak efficiency and wide input voltage range, the residential TRIO inverter means flexible installations and powerful output. 01 01 TRIO5.8/7.5/8.5 TLOUTD outdoor string inverter Commercial grade engineering at residential scale The topology of the larger, commercial TRIO inverters has been redesigned to ensure that the TRIO 5.8/7.5/8.5 models also enjoy high conversion efficiency across a wide range of input voltages. Optional integrated dataloggers and smart grid functionality, remote firmware updating and elegantly simple sliding front covers make these allinone devices easy to install and maintain. In short, they are commercial grade engineering at residential scale. Inverters packed with powerful features The double maximum power point tracker (MPPT) gives maximum installation flexibility for an optimal energy production (TRIO7.5/8.5 models). This line of inverters can integrate power control, monitoring functionalities and environmental sensor inputs, without requiring external components. A compact Ethernet expansion card provides data logging functionality for monitoring the main parameters of the plant as well as advanced O&M operations both locally (with the integrated webserver) and remotely (with the AV Plant Portfolio Manager portal), via a LAN connection. The outer cover with its natural cooling mechanism qualifies at IP65 environmental protection level for external use. It provides maximum reliability and ease of installation, with a sliding front panel giving access to the connection and configuration area without requiring the complete removal of the cover. Highlights Threephase bridge topology for DC/ AC output converter Transformerless topology Two independent MPPT channels for TRIO7.5/8.5 allow optimal energy harvesting from two subarrays oriented in different directions (one MPPT channel for TRIO5.8) Flat efficiency curves ensure high efficiency at all output levels enabling consistent and stable performance across the entire input voltage and output power range Wide input voltage range Remote inverter upgrade Reactive power management DC switch version available (S) Natural convection cooling for maximum reliability Outdoor enclosure for unrestricted use under any environmental conditions (IP65) Sliding cover for the easiest installation and maintenance Data logger and smart grid functionalities integrated on expansion cards: PMU expansion card option, with external sensor inputs for monitoring environmental conditions and additional RS485 for Modbus protocol Ethernet expansion card option with integrated web server and remote monitoring capability via web portal (Modbus/TCP supported) Availability of auxiliary DC output voltage (24 V, 100 ma)

PRODUCT FLYER FOR TRIO5.8/7.5/8.5TLOUTD ABB SOLAR INVERTERS ABB string inverters TRIO5.8/7.5/8.5TLOUTD 5.8 to 8.5 kw Type code TRIO5.8TLOUTD TRIO7.5TLOUTD TRIO8.5TLOUTD Input side Absolute maximum DC input voltage (Vmax,abs) 1000 V Startup DC input voltage (Vstart) 350 V (adj. 200...500 V) Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x Vstart 950 V (min 200 V) Rated DC input voltage (Vdcr) 620 V Rated DC input power (Pdcr) 5950 W 7650 W 8700 W Number of independent MPPT 1 2 2 Maximum DC input power for each MPPT (PMPPTmax) 6050 W Linear derating from max to 4800 W 4800 W null [800 V VMPPT 950 V] MPPT input DC voltage range (VMPPTmin... VMPPTmax) at Pacr 320 800 V DC input voltage range with parallel configuration of MPPT at Pacr 320 800 V 320 800 V DC power limitation with parallel configuration of MPPT Linear derating from max to null [800 V VMPPT 950 V] DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 4800 W [320 V VMPPT 800 V] the other channel: Pdcr4800 W [215 V VMPPT 800 V] 4800 W [320 V VMPPT 800 V] the other channel: Pdcr4800 W [290 V VMPPT 800 V] 18.9 A 30.0 A / 15.0 A 30.0 A / 15.0 A Maximum input short circuit current for each MPPT 24.0 A 20.0 A 20.0 A Number of DC input pairs for each MPPT 2 (S version) DC connection type PV quick fit connector 3) on S version / Screw terminal block on standard version Input protection Reverse polarity protection Yes, from limited current source Input over voltage protection for each MPPT varistor Yes, 4 Photovoltaic array isolation control DC switch rating for each MPPT (version with DC switch) 16 A /1000 V, 25 A / 800 V Output side AC grid connection type Threephase 3WPE or 4WPE Rated AC power (Pacr @cosφ=1 ) 5800 W 7500 W 8500 W Maximum apparent power (Smax) 5800 VA 7500 VA 8500 VA Rated AC grid voltage (Vac,r) 400 V AC voltage range 320...480 V 1) Maximum AC output current (Iac,max) 10.0 A 12.5 A 14.5 A Contributory fault current 12.0 A 14.5 A 16.5 A Rated output frequency (fr) 50 Hz / 60 Hz Output frequency range (fmin...fmax) 47...53 Hz / 57 63 Hz 2) Nominal power factor and adjustable range > 0.995, adj. ± 0.9 with Pacr =5.22 kw, ± 0.8 with max 5.8 kva > 0.995, adj. ± 0.9 with Pacr =6.75 kw, ± 0.8 with max 7.5 kva > 0.995, adj. ± 0.9 with Pacr =7.65 kw, ± 0.8 with max 8.5 kva Total current harmonic distortion < 2% AC connection type Screw terminal block, cable gland M32 Output protection Antiislanding protection Maximum external AC overcurrent protection 16.0 A 16.0 A 20.0 A Output overvoltage protection varistor 4 plus gas arrester Operating performance Maximum efficiency (ηmax) 98.0% Weighted efficiency (EURO/CEC) 97.4% / 97.5% / 97.5% / Feed in power threshold 32 W 36 W 36 W Night consumption < 3 W

PRODUCT FLYER FOR TRIO5.8/7.5/8.5TLOUTD ABB SOLAR INVERTERS ABB TRIO5.8/7.5/8.5TLOUTD string inverter block diagram.1().1().2() MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC).1().1().2() Line filter Grid parallel relay L1 L2 L3 *IN2.1() *IN2.1() *IN2.2() MPPT 2 (DC/DC) N PE IN2 IN2 *IN2 *IN2.1() *IN2.1() *IN2.2() Standard version S version Control circuit (*) Not available in TRIO5.8TLOUTD versions DC/DC DSP contr. DC/AC DSP contr. RJ_45 Ethernet board (opt.) T/R T/R GND K1 K2 K3 K4 I1 I2 GND AN1 AN1 COM AN2 AN2 COM 24V GND PT1 PT2 PT3 MODBUS/PMU RS485 PMU digital input PMU analog input Analog input Analog input 24 V 100 ma Thermal sensor PT100/PT1000 Service board (opt.) µp Supervisor board Service pc_rs485 Remote control 1 Remote control 2 Alarm T/R T/R GND R GND R GND N.C N.O C Type code TRIO5.8TLOUTD TRIO7.5TLOUTD TRIO8.5TLOUTD Communication Wired local monitoring Ethernet card with webserver (opt.), PVIUSBRS232_485 (opt.) Remote monitoring Ethernet card (opt.), VSN300 Wifi Logger Card (opt.), VSN700 Data Logger (opt.) Wireless local monitoring VSN300 Wifi Logger Card (opt.) User interface Graphic display Environmental Ambient temperature range 25...60 C /13...140 F with derating above 50 C/122 F Relative humidity 0...100% condensing Sound pressure level, typical 50 dba @ 1 m Maximum operating altitude without derating 2000 m / 6560 ft Physical Environmental protection rating IP65 Cooling Natural Dimension (H x W x D) 641mm x 429 mm x 220 mm/ 25.2 x 16.9 x 8.7 (855 mm x 429 mm x 237 mm/ 33.7 x 16.9 x 9.3 with open front cover) Weight 25.0 kg / 55.1 lbs 28.0 kg / 61.7 lbs 28.0 kg / 61.7 lbs Mounting system Wall bracket Safety Isolation level Transformerless Marking CE (50 Hz only), RCM Safety and EMC standard EN 6210, EN 621092, AS/NZS3100, EN 6100062, EN 6100063, EN 6100032, EN 6100033 Grid standard (check your sales channel for availability) CEI 021, CEI 016, DIN V VDE V 012611, VDEARN 4105, G83/2, G59/3, RD 1699, RD 413, NRS09721, AS 4777, IEC 61727, IEC 62116, VFR 2014 Available products variants Standard TRIO5.8TLOUTD400 TRIO7.5TLOUTD400 TRIO8.5TLOUTD400 With DC switch TRIO5.8TLOUTDS400 TRIO7.5TLOUTDS400 TRIO8.5TLOUTDS400 1) The AC voltage range may vary depending on specific country grid standard 2) The Frequency range may vary depending on specific country grid standard 3) Please refer to the document String inverters Product manual appendix available at www.abb.com/solarinverters for information on the quickfit connector brand and model used in the inverter Remark. Features not specifically listed in the present data sheet are not included in the product

Efficiency curves of TRIO5.8TLOUTD Efficiency curves of TRIO8.5TLOUTD 100 100 99 99 98 98 97 97 Efficiency [%] 95 94 Efficiency [%] 95 94 93 93 92 320 Vdc 92 320 Vdc 620 Vdc 620 Vdc 800 Vdc 800 Vdc 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power 90 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved BCD.00376_EN REV F 15.05.2017

SOLAR INVERTERS ABB string inverters UNO2.0/3.0/3.6/4.2TLOUTD 2 to 4.2 kw This new line of transformerless singlephase inverters completes the UNO family as an optimal solution to maximize the return on investment (ROI) for residential systems. 01 01 UNO2.0/3.0/3.6/4.2 TLOUTD outdoor string inverter The new design wraps ABB s quality and engineering into just 12 kgs thanks to technological choices optimized for installations with a uniform orientation. Easy to install The presence of Plug and Play connectors, both on the DC and AC side as well as on the RS485 communication port, enable a simple, fast and safe installation of the unit even in harsh weather conditions without the need of opening the front cover of the inverter. Highlights Singlephase output Transformerless topology Each inverter is set to specific grid codes which can be selected in the field Wide input range and high efficiency values High speed and precise MPPT algorithm enables realtime power tracking and improved energy harvesting Plug and Play connection for DC, AC and communication side Flexibility The compatibility with the VSN300 Wifi Logger Card (optional) within the integrated expansion slot, assures an advanced and cost effective solution for the control and monitoring of the plant, without the need of further components Integrated load manager for control of energy consumption

PRODUCT FLYER FOR UNO2.0/3.0/3.6/4.2TLOUTD ABB SOLAR INVERTERS ABB string inverters UNO2.0/3.0/3.6/4.2TLOUTD 2 to 4.2 kw Type code UNO2.0TLOUTD UNO3.0TLOUTD UNO3.6TLOUTD UNO4.2TLOUTD Input side Absolute maximum DC input voltage (Vmax,abs) 600 V 600 V 850 V 850 V Startup DC input voltage (Vstart) 100...300 V 100...300 V (default 150 V) (default 150 V) 380 V 380 V Operating DC input voltage range (Vdcmin...Vdcmax) 0.7xVstart...580 V 0.7xVstart...580 V (min 80 V) (min 80 V) 350...820 V 350...820 V Rated DC input voltage (Vdcr) 400 V 400 V 500 V 600 V Rated DC input power (Pdcr) 2200 W 3200 W 3900 W 4500 W Number of independent MPPT 1 MPPT input DC voltage range (VMPPTmin...VMPPTmax) at Pacr 180...500 V 200...500 V 380 700 V 380 700 V Maximum DC input current (Idcmax) 12.5 A 16.0 A 12.5 A 12.5 A Number of DC inputs pairs 1 DC connection type PV quick fit connector 3) Input protection Reverse polarity protection Input over voltage protection varistor Photovoltaic array isolation control Yes, from limited current source Yes DC switch rating (version with DC switch) 600 V, 25 A 1000 V, 16 A Output side AC Grid connection type Singlephase Rated AC power (Pacr @cosφ=1 ) 2000 W 3000 W 3600 W 4200 W Maximum AC output power (Pacmax @cosφ=1) 2000 W 3000 W 3600 W 4200 W Maximum apparent power (Smax) 2000 VA 3000 VA 3600 VA 4200 VA Rated AC grid voltage (Vac,r) AC voltage range 180...264 V 1) Maximum AC output current (Iac,max) 10.0 A 15.0 A 16.0 A 20.0 A Contributory fault current 12.0 A 17.0 A 18.0 A 22.0 A Rated output frequency (fr) 230 V 50 Hz / 60 Hz Output frequency range (fmin...fmax) 47...53 Hz / 57 63 Hz 2) Nominal power factor and adjustable range > 0.995, adj. ± 0.8 with max Smax Total current harmonic distortion < 3% AC connection type Panel female connector Output protection Antiislanding protection Maximum external AC overcurrent protection 16.0 A 20.0 A 20.0 A 25.0 A Output overvoltage protection varistor 2 (L N / L PE)

PRODUCT FLYER FOR UNO2.0/3.0/3.6/4.2TLOUTD ABB SOLAR INVERTERS ABB UNO2.0/3.0/3.6/4.2TLOUTD string inverter block diagram MPPT 1* (DC/DC) Bulk caps Inverter (DC/AC) Line filter Grid parallel relay L Standard version S version Residual current detection P RS485 DC/AC DSP contr. Micro Safety Remote Control µp Alarm Stand alone (* not present for 3.6/4.2 versions) Control circuit Type code UNO2.0TLOUTD UNO3.0TLOUTD UNO3.6TLOUTD UNO4.2TLOUTD Operating performance Maximum efficiency (ηmax) 97.3% 97.3% 98.4% 98.4% Weighted efficiency (EURO/CEC).0% /.0% / 97.5% / 97.5% / Feed in power threshold 10 W 10 W 8 W 8 W Night consumption Communication Remote monitoring Wireless local monitoring User interface Environmental < 0.1 W VSN300 Wifi Logger Card (opt.) VSN300 Wifi Logger Card (opt.) Display (2x16 line LCD) Ambient temperature range 20...60 C, with derating > 45 C Relative humidity Maximum operating altitude without derating Physical Environmental protection rating Cooling 0 100% condensing 2000 m / 6560 ft IP65 Natural Dimension (H x W x D) 553 x 418 x 175 mm / 21.8 x 16.5 x 6.9 Weight Mounting system Safety Isolation level Marking 12 kg / 26.45 lb Wall bracket Transformerless Safety and EMC standard IEC/EN 6210, IEC/EN 621092, EN 6100062, EN 6100063, EN 6100032, EN 6100033 Grid standard (check your sales channel for availability) C10/11, EN 50438, CEI 021, DIN V VDE V 012611, VDEARN 4105, G83/2, G59/3, VFR 2014, IEC 61727, IEC 62116, NRS09721, RD 413, AS 4777, MEA, ABNT NBR16149/16150 Available products variants Standard UNO2.0TLOUTD UNO3.0TLOUTD UNO3.6TLOUTD UNO4.2TLOUTD With DC switch UNO2.0TLOUTDS UNO3.0TLOUTDS UNO3.6TLOUTDS UNO4.2TLOUTDS CE 1) The AC voltage range may vary depending on specific country grid standard 2) The Frequency range may vary depending on specific country grid standard 3) Please refer to the document String inverters Product manual appendix available at www.abb.com/solarinverters for information on the quickfit connector brand and model used in the inverter Remark. Features not specifically listed in the present data sheet are not included in the product

Efficiency curves of UNO3.0TLOUTD Efficiency curves of UNO4.2TLOUTD 99 98 97 95 94 99 98 97 95 94 Efficiency [%] 93 92 Efficiency [%] 93 92 90 90 89 89 88 200 Vdc 88 380 Vdc 87 400 Vdc 87 600 Vdc 86 500 Vdc 86 700 Vdc 85 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of rated Output Power 85 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of rated Output Power For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved BCD.00613_EN REV H 23.05.2017

SOL A R INVERTER S ABB string inverters UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS 1.2 to 5.0 kw The new UNODMPLUS singlephase inverter family, with power ratings from 1.2 to 5.0 kw, is the optimal solution for residential installations. 01 01 UNODM 1.2/2.0/3.3/4.0/4.6/5.0 TLPLUS outdoor string inverter One size fits all The new design wraps ABB s quality and engineering into a lightweight and compact package thanks to technological choices optimized for installations with different orientation. All power ratings share the same overall volume, allowing higher performance in a minimum space, and have a dual Maximum Power Point Tracker (2 MPPT). Easy to install, fast to commission The presence of Plug and Play connectors, both on the DC and AC side, as well as the wireless communication, enable a simple, fast and safe installation without the need of opening the front cover of the inverter. Vision remote monitoring experience. The advanced communication interfaces (WLAN, Ethernet, RS485) combined with an efficient Modbus (RTU/TCP) communication protocol, Sunspec compliant, allow the inverter to be easily integrated within any smart environment and with third party monitoring and control systems. A complete set of control functions with the embedded efficient algorithm, enabling dynamic control of the feedin (i.e. zero injection), make the inverter suitable for worldwide applications in compliance with regulatory norms and needs of the utilities. The futureproof and flexible design enables integration with current and future devices for smart building automation. The featured easy commissioning routine removes the need for a long configuration process, resulting in lower installation time and costs. Improved user experience thanks to a build in User Interface (UI), which enables access to features such as advanced inverter configuration settings, dynamic feedin control and load manager, from any WLAN enabled devices (smartphone, tablet or PC). Smart capabilities The embedded logging capabilities and direct transferring of the data to Internet (via Ethernet or WLAN) allow customers to enjoy the whole Aurora Highlights Wireless access to the embedded Web User Interface Easy commissioning capability Futureproof with embedded connectivity for smart building and smart grid integration Dynamic feedin control (for instance zero injection ) Remote Over The Air (OTA) firmware upgrade for inverter and components Modbus TCP/RTU Sunspec compliant Remote monitoring via Aurora Vision cloud Dual input section with independent MPPT

PRODUCT FLYER FOR UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS ABB SOLAR INVERTERS ABB string inverters UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS 1.2 to 5.0 kw Type code UNODM1.2TLPLUS UNODM2.0TLPLUS UNODM3.3TLPLUS Input side Absolute maximum DC input voltage (Vmax,abs) Startup DC input voltage (Vstart) 120 V (adj. 100 150 V) 150 V (adj. 100 250 V) 200 V (adj. 120...350 V) Operating DC input voltage range 0.7 x Vstart...580 V (min 90 V) (Vdcmin...Vdcmax) Rated DC input voltage (Vdcr) 185 V 300 V 360 V Rated DC input power (Pdcr) 1500 W 2500 W 3500 W Number of independent MPPT 1 1 2 Maximum DC input power for each MPPT (PMPPTmax) 1500 W 2500 W 2000 W DC input voltage range with parallel configuration of MPPT at Pacr 100 530 V 210...530 V 170...530 V DC power limitation with parallel configuration of Linear derating from Max to Null N/A N/A MPPT [530 V VMPPT 580 V] DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example N/A N/A 2000 W [200 V VMPPT 530 V] the other channel: Pdcr2000 W [112 V VMPPT 530 V] Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A 10.0 A 20.0 / 10.0 A Maximum input short circuit current for each MPPT 12.5 A 12.5 A 12.5 / 25.0 A Number of DC input pairs for each MPPT 1 DC connection type 1) Input protection Reverse polarity protection Input over voltage protection for each MPPTvaristor Photovoltaic array isolation control DC switch rating for each MPPT (version with DC switch) Output side AC grid connection type 600 V Quick Fit PV Connector Yes, from limited current source Yes 25 A / 600 V Singlephase Rated AC power (Pacr @cosφ=1 ) 1200 W 2000 W 3300 W Maximum AC output power (Pacmax @cosφ=1) 1200 W 2000 W 3300 W Maximum apparent power (Smax) 1200 VA 2000 VA 3300 VA Rated AC grid voltage (Vac,r) AC voltage range 3) 230 V 180...264 V Maximum AC output current (Iac,max) 5.5 A 10.0 A 14.5 A Contributory fault current 10.0 A 12.0 A 16.0 A Rated output frequency (fr) 4) Output frequency range (fmin...fmax) 4) Nominal power factor and adjustable range 50/60 Hz 47...53/57...63 Hz > 0.995, adj. ± 0.1 1 (over/under excited) Total current harmonic distortion < 3.5% AC connection type Output protection Antiislanding protection Female connector from panel Maximum external AC overcurrent protection 10.0 A 16.0 A 20.0 A Output overvoltage protection varistor 2 (L N / L PE)

PRODUCT FLYER FOR UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS ABB SOLAR INVERTERS ABB UNODM1.2/2.0TLPLUS string inverter block diagram () () MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC) Line filter Grid parallel relay L () () N Standard version S version PE Residual current detection Optional DC/DC DSP contr. DC/AC DSP contr. RS485 Remote control T/R T/R RTN R R µp Load manager/ Alarm N.C N.O C Control circuit WLAN Type code UNODM1.2TLPLUS UNODM2.0TLPLUS UNODM3.3TLPLUS Operating performance Maximum efficiency (ηmax) 94.8%.7% 97.0% Weighted efficiency (EURO/CEC) 92.0% 95.0%.5% / Feed in power threshold Night consumption Embedded communication Embedded communication interface 5) Embedded communication protocol Commissioning tool Monitoring Optional board UNODMCOM kit Optional communication interface Optional communication protocol Optional board UNODMPLUS Ethernet COM kit Optional communication interface Optional communication protocol Environmental Ambient temperature range Relative humidity Maximum operating altitude without derating Physical 8 W <0.4 W Wireless ModBus TCP (SunSpec) Web User Interface, Display, Aurora Manager Lite Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile RS485 (use with meter for dynamic feedin control), Alarm/Load manager relay, Remote ON/OFF ModBus RTU (SunSpec), Aurora Protocol Ethernet, RS485 (use with meter for dynamic feedin control), Alarm/Load manager relay, Remote ON/OFF ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol 25...60 C /13...140 F with derating above 50 C/122 F 25...60 C /13...140 F with derating above 50 C/122 F 0...100 % condensing 2000 m / 6560 ft Environmental protection rating IP 65 Cooling Natural Dimension (H x W x D) 553 x 418 x 175 mm / 21.8 x 16.5 x 6.9 Weight Mounting system Safety Isolation level Marking Safety and EMC standard Grid standard (check your sales channel for availability) 7) Available products variants 15 kg / 33 lbs Wall bracket Transformerless 25...60 C /13...140 F with derating above 50 C/122 F CE, RCM EN 50178, IEC/EN 6210, IEC/EN 621092, AS/NZS 3100, EN 6100061, EN 6100063, EN 6100032, EN 6100033 CEI 021, DIN V VDE V 012611, VDEARN 4105, G83/2, G59/3, RD 413, ITCBT40, AS/NZS 4777.2, C10/11, IEC 61727, IEC 62116 Standard UNODM1.2TLPLUSB UNODM2.0TLPLUSB UNODM3.3TLPLUSB With DC switch UNODM1.2TLPLUSSB UNODM2.0TLPLUSSB UNODM3.3TLPLUSSB 1) Refer to the document String inverter Product Manual appendix available at www.abb.com/solarinverters to know the brand and the model of the quick fit connector 2) For UK G83/2 setting, maximum output current limited to 16 A up to a maximum output Pacr of 3600 W and a maximum apparent power of 3600 VA 3) The AC voltage range may vary depending on specific country grid standard 4) The Frequency range may vary depending on specific country grid standard; CE is valid for 50Hz only 5) As per IEEE 802.11 b/g/n standard 6) Pacr = 4200 W @ 45 C/113 F 7) Further grid standard will be added, please refer to ABB Solar page for further details Remark. Features not specifically listed in the present data sheet are not included in the product

PRODUCT FLYER FOR UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS ABB SOLAR INVERTERS UNODMPLUS: Efficient, connected, smart. Type code UNODM4.0TLPLUS UNODM4.6TLPLUS UNODM5.0TLPLUS Input side Absolute maximum DC input voltage (Vmax,abs) Startup DC input voltage (Vstart) 200 V (adj. 120...350 V) Operating DC input voltage range 0.7 x Vstart...580 V (min 90 V) (Vdcmin...Vdcmax) Rated DC input voltage (Vdcr) Rated DC input power (Pdcr) 4250 W 4750 W 5150 W Number of independent MPPT 2 Maximum DC input power for each MPPT (PMPPTmax) 3000 W 3000 W 3500 W DC input voltage range with parallel configuration of MPPT at Pacr 130...530 V 150...530 V 145...530 V DC power limitation with parallel configuration of MPPT Linear derating from Max to Null [530V VMPPT 580V] DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example 3000 W [190 V VMPPT 530 V] the other channel: Pdcr3000 W [90 V VMPPT 530 V] 3000 W [190 V VMPPT 530 V] the other channel: Pdcr3000 W [90 V VMPPT 530 V] 3500 W [200 V VMPPT 530 V] the other channel: Pdcr3500 W [90 V VMPPT 530 V] Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 32.0 / 16.0 A 32.0 / 16.0 A 38.0 / 19.0 A Maximum input short circuit current for each MPPT 20.0 / 40.0 A 20.0 / 40.0 A 22.0 / 44.0 A Number of DC input pairs for each MPPT 1 DC connection type 1) Input protection Reverse polarity protection Input over voltage protection for each MPPTvaristor Photovoltaic array isolation control DC switch rating for each MPPT (version with DC switch) Output side AC grid connection type 600 V 360 V Quick Fit PV Connector Yes, from limited current source Yes 25 A / 600 V Singlephase Rated AC power (Pacr @cosφ=1 ) 4000 W 4600 W 5000 W Maximum AC output power (Pacmax @cosφ=1) 4000 W 2) 4600 W 5000 W Maximum apparent power (Smax) 4000 VA 2) 4600 VA 5000 VA Rated AC grid voltage (Vac,r) AC voltage range 3) 230 V 180...264 V Maximum AC output current (Iac,max) 17.2 A 20.0 A 22.0 A Contributory fault current 19.0 A 22.0 A 24.0 A Rated output frequency (fr) 4) Output frequency range (fmin...fmax) 4) Nominal power factor and adjustable range 50/60 Hz 47...53/57...63 Hz > 0.995, adj. ± 0.1 1 (over/under excited) Total current harmonic distortion < 3.5 AC connection type Output protection Antiislanding protection Female connector from panel Maximum external AC overcurrent protection 25.0 A 25.0 A 32.0 A Output overvoltage protection varistor 2 (L N / L PE)

PRODUCT FLYER FOR UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS ABB SOLAR INVERTERS ABB UNODM3.3/4.0/4.6/5.0TLPLUS string inverter block diagram.1().1() MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC) Line filter Grid parallel relay L.1().1() N IN2.1() IN2.1() MPPT 2 (DC/DC) IN2 IN2 IN2 PE IN2.1() IN2.1() Residual current detection Optional RS485 T/R Standard version S version T/R RTN DC/DC DSP contr. µp DC/AC DSP contr. Remote control Load manager/ Alarm R R N.C N.O C Control circuit WLAN Type code UNODM4.0TLPLUS UNODM4.6TLPLUS UNODM5.0TLPLUS Operating performance Maximum efficiency (ηmax) 97.0% 97.0% 97.4% Weighted efficiency (EURO/CEC).5% /.5% / 97.0% / Feed in power threshold Night consumption Embedded communication Embedded communication interface 5) Embedded communication protocol Commissioning tool Monitoring Optional board UNODMCOM kit Optional communication interface Optional communication protocol Optional board UNODMPLUS Ethernet COM kit Optional communication interface Optional communication protocol Environmental Ambient temperature range Relative humidity Maximum operating altitude without derating Physical 8 W <0.4 W Wireless ModBus TCP (SunSpec) Web User Interface, Display, Aurora Manager Lite Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile RS485 (use with meter for dynamic feedin control), Alarm/Load manager relay, Remote ON/OFF ModBus RTU (SunSpec), Aurora Protocol Ethernet, RS485 (use with meter for dynamic feedin control), Alarm/Load manager relay, Remote ON/OFF ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol 25...60 C /13...140 F with derating above 50 C/122 F 25...60 C /13...140 F with derating above 45 C/113 F 6) 0...100 % condensing 2000 m / 6560 ft Environmental protection rating IP 65 Cooling Natural Dimension (H x W x D) 553 x 418 x 175 mm / 21.8 x 16.5 x 6.9 Weight Mounting system Safety Isolation level 15 kg / 33 lbs Wall bracket Transformerless 25...60 C /13...140 F with derating above 45 C/113 F Marking CE, RCM IEC/EN 6210, IEC/EN 621092, AS/NZS 4777.2, EN 6100061, EN 6100062, EN 6100063, Safety and EMC standard EN 6100064, EN 61000311, EN 61000312 Grid standard CEI 021, DIN V VDE V 012611, VDEARN 4105, G83/2, G59/3, RD 413, ITCBT40, AS/NZS 4777.2, (check your sales channel for availability) 7) C10/11, IEC 61727, IEC 62116 Available products variants Standard UNODM4.0TLPLUSB UNODM4.6TLPLUSB UNODM5.0TLPLUSB With DC switch UNODM4.0TLPLUSSB UNODM4.6TLPLUSSB UNODM5.0TLPLUSSB 1) Refer to the document String inverter Product Manual appendix available at www.abb.com/solarinverters to know the brand and the model of the quick fit connector 2) For UK G83/2 setting, maximum output current limited to 16 A up to a maximum output Pacr of 3600 W and a maximum apparent power of 3600 VA 3) The AC voltage range may vary depending on specific country grid standard 4) The Frequency range may vary depending on specific country grid standard; CE is valid for 50Hz only 5) As per IEEE 802.11 b/g/n standard 6) Pacr = 4200 W @ 45 C/113 F 7) Further grid standard will be added, please refer to ABB Solar page for further details Remark. Features not specifically listed in the present data sheet are not included in the product

For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved BCD.00647 EN REV H 31.10.2017