AR2000 Rheometer: Instructions

Similar documents
AR2000ex Rheometer Standard Operating Procedures Revised: 5/1/2018

Setting Up an Oscillation Amplitude Sweep Test

CALMETRIX INC. PHESO CONCRETE RHEOMETER

RheoStress 600. The Modular High-Tech Rheometer

english Series 1 The versatile rheometer concept

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame.

USV Ultra Shear Viscometer

Techcon Systems TS5000 Series Rotary Valve

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Safety Considerations

PRSalpha Air Drill (Double Valve)

AURORA SERIES GAUGES FUEL GAUGE SUGGESTED TOOLS AND MATERIALS. 3 3 /8 in (85.7 mm) PARTS LIST

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE Centrifugal Pump(Armfield)

Causes and Symptoms of Roll Feed Length Inaccuracy

CHAPTER 5 CORDLESS GENERAL CORDLESS COMPONENTS

Motions and Forces Propeller

KISSsoft 03/2013 Tutorial 2

Heat Engines Lab 12 SAFETY

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

University of Jordan School of Engineering Mechatronics Engineering Department. Fluid Power Engineering Lab

HAAKE Series 1. The versatile rheometer concept. Analyze Detect Measure Control TM

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

Models Affected: Certain 2013 Model Year Propane Vision Buses Equipped with Ford 6.8L Engines CORRECTIVE ACTION ---- PROCEDURE

63-82 CORVETTE IMPALA KIT INSTRUCTIONS

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

Stress/Strain Apparatus AP-8214

GPK for Design and Rating of Industrial Gearboxes

Installation Instructions

JMW 10 AND 12 Tonearms

Welcome to VBar Express 5.3

Atomic Absorption Spectroscopy

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

OFITE HTHP Viscometer. Part No Instruction Manual

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

Hypertech Speedometer Calibrator Module Installation Instructions. PN Toyota Tundra & Sequoia

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

The M7 Direct Flow Intercooler (DFIC) Installation Guide

ProECU Mazda MX-5. Live Data Guide 2005-onward Model Year. v1.06

Prop-Tech Vacuum Analyzer

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

PROBLEM REQUIRED TOOLS, PARTS AND PRODUCTS SOLUTION. Problem A. Problem B

Probe Driver for Visual Plus 3. (c) , Saryna Technologies LLC/Advanced Inspection Technology

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

Operation and Maintenance Manual

AssayMAP 96AM Wash Station. Maintenance Guide

(C6) Chevrolet Corvette Crank Scraper and Oil Pan Baffle Kit

PHOENIX Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Read this document carefully before implementing the upgrade!

CETAC Z-Drive Nylon Cable

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

User Manual. Aarhus University School of Engineering. Windtunnel Balance

PRESSURE SENSOR INSTRUCTIONS

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

Model 50SL Rheometer Instruction Manual

PHOENIX Features of the Phoenix-10 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Setup, Assembly, & Adjustment

INSTRUCTION MANUAL. Smart Pressure. Variable Pressure Diagnostic Smoke Machine. with UltraTraceUV Non-Contaminant Dye Solution Model No.

MAF Fusion. Installation and operating instructions. MAF Fusion mass airflow sensor signal interface module & auxiliary injector controller

Jon Konings Former CEM Coordinator

DTN Biodiesel Documentation

4. Remove distributor hold-down. Lift the distributor upwards and remove.

Control Box Wiring For PRSstandard Tool

Faraday's Law of Induction

Micro Tensile Tester User Manual

Heating Methods. Reflux and Distillation

Section 10: Engraving Machine Cleaning

Tube Bender. Machine Type - Tube Bender

4.1 Flow Rate Verification and Adjustment

PCU-200 Laboratory Viscometer

Lab 4 Constant Acceleration by Drew Von Maluski

ElPower script. Contents. ElPower script diagnostics of the engine starting and charging system

Concepts of One Dimensional Kinematics Activity Purpose

Instruction Manual Revision F. Model 50SL Rheometer Instruction Manual

Baxter 6201 and 6301 Tips to Avoid Nuisance Alarms Call x 335 for troubleshooting assistance.

FIS Low Pressure Leak Test March Publication Number / Title Platform Section Title Change. FIS Low Pressure Leak Test- Three-Filter Fuel System

FLP-2492/KLP-4492 Impeller Flowmeter

Radnoti Modular Wire Myograph System Assembly and Basic Principles

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation

Regards from the Team at Rheology Solutions.

UNIFLO Control Valve

Tri-roll External Thread Gage

BROOKFIELD MODEL BF35. Installation, Operation and Maintenance Instructions. Manual No. M

Owners manual. Öhlins Superbike front fork FG 170

EXPERIMENT 11: FARADAY S LAW OF INDUCTION

Lesson 8: A Compound Spur Gear Train

MiTek Machinery Division. Service Bulletin

Maintenance Adjustments

DLF-220L Digital Label Finishing System

INSTALLATION MANUAL BULLET PROOF OIL COOLER KIT F-SERIES

Copyright 2012 Pulse Systems, Inc. Page 1 of 53

Tutorial: Calculation of two shafts connected by a rolling bearing

KISSsoft 03/2017 Tutorial 15

DISCOVERY HYBRID RHEOMETER

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Weistec M113K Supercharger System Installation Guide

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Index. Calculated field creation, 176 dialog box, functions (see Functions) operators, 177 addition, 178 comparison operators, 178

XLR-8 60 Extended Rack Autosampler

1) Introduction to wind power

Transcription:

AR2000 Rheometer: Instructions Instrument Setup Note: The order in which the things are powered on is very important! 1. Check to make sure the Smart Swap cable is connected to the machine. 2. Make sure the compressed air line is open before turning on the instrument. This may take a few seconds as the pressure stabilizes to a constant value of 30 psi. 3. Remove the bearing lock cap by rotating the screw on the top in the counter clockwise direction and leave the screw as it is.

4.Turn on the water pump by placing the plug into the outlet. 5. Make sure that the inlet of the pump is immersed in water and the water level does not exceed the maximum level marked by the lower edge of the tape. When re-filling with water, add 1/4 of TA Conditioner bottle for heat exchange. 6. Turn the machine on. The power switch is located at the back of the controller on the right hand side.

7. At this stage, the spindle of the rheometer should be freely turning and the temperature reading on the monitor should be constant. Software Setup 1. Click on the <AR Instrument control> icon on the desktop. 2. First, calibrate the instrument inertia. This only needs to be done ~once/semester and will be performed by the person in charge of the instrument. Go to the options tab on the top tool bar and select instrument. On the pop-up, go to the inertia tab, and select calibrate. Let the instrument calibrate, and the final value for the instrument inertia should be about 15 micro N.m.s^2. 3. Attach the appropriate geometry by gently pushing the spindle up the screw and tightening the top screw by rotating it clockwise. Click on the geometry tab and ensure that the proper geometry is attached. If the geometry name needs to be switched, go to the geometry tab and select open. From here, you can select the proper geometry that is being used. 4. Now calibrate the bearing friction. Go to the options tab on the top toolbar and select instrument. On the pop-up, go to the miscellaneous tab and select calibrate. Let the instrument calibrate. 5. Click on the <instrument rotational mapping> button on the left hand side. This subtracts the background force that is used up by the air bearing shaft to rotate about its own axis from the actual shear measurements. It is necessary to perform this when switching between geometries and performing low viscosity experiments. 6. Click perform mapping. The process takes about 5 minutes.

7. Double click on the displayed value of Gap, enter 1500 micrometer and click on send. 8. Click on the < zero gap> button. A dialogue box will appear on the screen. Click on continue. This makes sure that the Peltier plate and the geometry are perfectly parallel to each other. 6. Once the zero gap procedure is completed, a message will appear on the screen asking if you would want to set the head to back off position. Click on Yes. 7. For Temp Sweep Experiments ONLY: Perform Gap Temperature Compensation at this point. See end of document for procedure. Loading of sample 1. Select the appropriate geometry tab below the task bar. 2. Click on dimension tab and enter the value of the gap between the upper geometry and the lower plate. The recommended gap value is 1000 microns (but this does vary from sample to sample). A typical value is 10x the largest particle size in your system.

3. Click on the Settings tab. Based on the gap value entered and the type of geometry, the software gives an estimate of the amount of the sample (in ml) that would be ideal for the experiment. It is a good idea to add slight excess. 4. If the solvent is volatile, then it is recommended that you use the solvent trap for the experiments. (a). Click on the bearing lock icon on the LHS column of the screen. This will prevent the head from turning. CAUTION: DO NOT TRY TO TURN THE BEARING HEAD WITH THE BEARING LOCK ON OR YOU WILL DAMAGE THE INSTRUMENT. (b). Add the solvent to the back of the upper geometry (without turning the geometry remember bearing lock is on). (c). Place the solvent trap ring in the middle of the Peltier plate.

6. Load your sample on the Peltier plate. The most ideal loading of the sample on the plate is as shown in the figure. However one can overfill the sample and then trim off the sides. Caution: In case of underfilling, discard the sample and load a fresh sample after thoroughly cleaning the Peltier plate and the geometry. 7. Send the gap to the truncation distance <Instrument> <Gap> <Go to geometry gap>. 8. Trim the excess sample from the sides. 9. Add the solvent cover. (Make sure the solvent trap box is checked if you are using it.) Taking Measurements 1. Make sure the instrument is set at the geometry gap (e.g., 1000 micrometers)

2. Set the oscillation procedure details by clicking on the oscillation procedures tab below the task bar. 3. Perform a strain sweep first to determine the linear viscoelastic region (LVR). This will allow you to determine an acceptable strain to use in the frequency sweep measurements. Load the sample and run the experiment. 4. Using a new gel sample, run a frequency sweep. Input the lower and upper limit of the frequency and the value of the stress you would like to use (that is in the LVR) (generally oscillation stress determined by the stress sweep experiments). 5. To add a step, right click on the previous steps and select add step. 6. Click on the Play button on the task bar. Input the sample information, file name and the directory in which it has to be stored. 7. To take another set of readings, clean the Peltier plate and the geometry thoroughly with acetone (see section VI steps 1 and 2) and re-start from section II, step 4. Data analysis 1. Click on the TA Data analysis icon on the Desktop. 2. Select the file from the location you stored it in section IV, step 5.

3. Double click on the file to get the graphical results. 4. To process data in the software, right click anywhere on the graph. 5. To change the variables on any of the axes, select the change variables option. 6. To change the appearance of the graph such as color, backgrounds, and the scale of the axes, click on properties. 7. Alternatively, to export data to Excel, click on the Table icon below the task bar. Right click anywhere to include more or less data variables. Copy the data into Excel.

Shut down (The order of shut down is important!) 1. Send the geometry to the back off distance by <Instrument> <Gap> <Raise Head>. Remove the geometry by gently pushing it upwards and turning the screw clockwise. 2. Gently clean the Peltier plate and the geometry with acetone. Rheological measurements are very sensitive to impurities, so thorough cleaning between two consecutive readings and before shutting down is highly recommended. Caution: While cleaning the Peltier plate, make sure minimum force is exerted on the plate as the instrument is sensitive to the amount of force applied on the Peltier plate. 3. Close all windows and running programs. 4. Switch off the machine by turning off the main switch at the back of the controller. 5. Switch off the pump and the motor by turning off the main power supply from the power strip. 6. Put on the bearing cap on the spindle similar to attaching a geometry. 7. Turn off the compressed air line. Since the valve connecting the air line to the rheometer is a bit sensitive, it is recommended that only the main line valve is closed. General precautions when using the heat exchanger The water pump should be running any time the Peltier plate is trying to control temperature (even close to room temperature). The water pump should be off any time the rheometer is off, or any time the Peltier plate is not connected or active. When operating at high temps, verify that the plate temperature is no more than 120 C greater than the circulator fluid temperature (e.g. if the fluid is at 20 C, the max plate temp is 140 C). At high temps it is also good to check the water level more regularly because it will evaporate more quickly. The water level should never be allowed to fall below the top of the pump. The pump should be oriented so that it is vertical, meaning that the water intake is from the top and the water intake be well submersed in water. Inlet and outlet tubings (blue tubes) should be free from kinks.

Procedure for Gap Temperature Compensation To be performed the first time before loading the sample. 1. Lower the geometry to geometry gap by clicking on the. 2. Click on the geometry tab -> settings and click on calibrate beside gap temperature compensation. 3. Enter the start and end temperature exactly identical to the temperatures in your procedure. 4. Click on next. 5. Finally, make sure Enable correction is checked.

Instrument Calibration Instrument Inertia 1. Go to Experiment -> Instrument and select inertia tab. 2. Click on Calibrate. 3. Make sure that geometry is NOT attached to the spindle and click on next. Geometry Inertia 1. Attach geometry to the rheometer. 2. Click on the Geometry tab and click on calibrate.

3. Click on next. Bearing Friction 1. Click on Options -> Instrument. 2. Click on Miscellaneous and click calibrate. 3. Click on Next.