L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Similar documents
L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Type Z & Ex pz purge and pressurization system

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Terminal Boxes in Stainless Steel SLS**.T

CYCLOPS Z Purge Indicator

CYCLOPS X Purge Controller XP Version

Assembly. Trunk IN + - S U, I U, I. Spur 1

CYCLOPS Z Purge Indicator

CYCLOPS X Purge Controller SM Version

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

CYCLOPS Y Purge Indicator

Solenoid coils VACF Type codes

Solutions Ex d IIB+H2, Stainless Steel EJBX*

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

INTERNATIONAL METAL ENGINEERING

Leading the way in hazardous areas Features EATON

Type 2REX-A. Oil & Gas / Heavy Industry

Pneumatic control unit for decentralized automation of ELEMENT process valves

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I Ex-safety switches I

I Ex-safety switches I

Sensor boxes SRBE Key features and product range overview

ExBin-P Pressure switches 5 Pa Pa

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Technical Data. Dimensions

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

JUMO dtrans p20 DELTA

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Resistance thermometer Without thermowell Model TR10-H

Main current switches >180 A are realized in metal enclosures. Internationally approved.

6mm and 14mm Slim Interface Relay

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

I Ex-Safety switches I

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Type Electronic Limit Switch

Load and Motor Switches, Load-Break Switches Series 8544

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

6mm Interface Relays RV8 Series

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Spring loaded resistance thermometer

A good connection. International approvals.

Position Switches Series 8070/2

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

3/2 and 4/2 directional seat valves with solenoid actuation

Operating pressure (bar) kv factor (m 3 /h) *3)

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Surface thermocouple Model TC50

Thermocouple For additional thermowell Model TC10-B

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Integrated Control modules

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Control Buttons / Switches for Panel Mounting Series 8003

Electronic Limit Switch Type

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Differential Pressure Sensors

Compact differential pressure switch Models DC, DCC

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Floodlight LED Series 6525

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

RedBin-P Pressure switches 5 Pa Pa

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Position Switches Series 8060/2

Solenoid coil for control in potentially explosive areas Type BZ

INSTRUCTION MANUAL (ATEX / IECEx)

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Series 3730 Electropneumatic Positioner Type

Compact Sheet-Steel Light Fittings Series 6114/1

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Thermocouple Without thermowell Model TC10-H

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Control Device System NEC Series ConSig 8040

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Position Switches Series 8074/2

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

RedCos-P Pressure sensor 20 Pa Pa

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Limit Switch Type 4747

Transcription:

Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals for Class I, II, Div. 2 and Zone 2/22 Universal mounting RTD inputs for temperature alarm and control Five standard purge programs Application The 5500 series purge/pressurization system consists of the control unit with a user interface in a 316 stainless steel enclosure that works in conjunction with the EPV vents and pneumatic solenoid valves or manual valves form a certified purge and pressurization system for enclosures. The user interface is menu driven and easily guides users through custom programing for their applications. (2) RTD s can be connected to inputs and the user can select temperature ranges for controlling and alarming critical temperatures through a set of contacts and energizing a solenoid valve for displacing air within the enclosure or operate cooling or heating functions. Enclosure pressure and leakage can be monitored. In the event of a loss in pressure a solenoid valve can engage to restore the defined pressure settings and/or alarm for pressure loss. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third party certifications for Class I, II/Div. 2 and Zone 2/22. External Mount Terminal Block Internal Mount Terminal Block K1 K2 C SV1 L(+) NC N(-) L(+) SV1 N(-) NC K2 C K1 T1 T2 Bypass N(-) N(-) N(-) K1 L(+) N(-) L(+) F1 SV1 F2 Power Terminal Block s F1 SV1 F2 Power L (+) N (-) SV1 K2 K1 N(-) N(-) N(-) L(+) N(-) L(+) K1 Bypass T1 T2 1

General specifications Operating mode fully automatic (FA) Series 5500 Number of volume exchanges 4... 19 Hazardous environment gas or dust Supply Rated voltage U r 100... 240 V AC, 0.05 A, 50... 60 Hz 20... 30 V DC, 0.2 A Power consumption 100... 240 V AC - 2.3 VA (without digital valve) 20... 30 V DC - 2.5 W (without digital valve) Electrical specifications Fuse rating F2: AC: 2 A DC: 3.15 A F1: AC: 0.08 A DC: 0.5 A Input Input I Temperature, up to 2 RTDs per unit Pt100, 2-wire-connection Input type temperature input Input II 1 Bypass passive contact (switch) Input type mechanical contact Output Output I K1, terminals: K1/N0, K1/N0 enclosure power, (1) SPST 6 A Contact loading 6 A at 250 V AC, 30 V DC resistive load, 6 A at 30 V DC Output II K2, terminals: K2 (, C, NC) alarm, (1) DPST 3 A Contact loading 3 A at 250 V AC, 30 V DC resistive load, 3 A at 30 V DC Output III digital valve, terminals SV (1) SPDT, powered contacts from supply 0.08 A at 250 VAC 0.5 A at 30 VDC 3 A Indicators/settings LED indication Membrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV1/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor Pneumatic parameters Protective gas supply instrument grade air or inert gas Safe pressure - gas 0.7 mbar (0.3" H 2 O) - dust 1.6 mbar (0.65" H 2 O) Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 RoHS Directive 2011/65/EU (RoHS) EN 50581:2012 Conformity Degree of protection EN 60529 Shock resistance EN 60068-2 Ambient conditions Ambient temperature -20... 40 C (-4... 104 F) at T6-20... 60 C (-4... 140 F) at T4 Relative humidity 5... 90 %, non-condensing Vibration resistance 5... 100 Hz, 1 g, 12 m/s 2, all axes Impact resistance 30 g, 11 ms, all axes Mechanical specifications 2

type Cable gland Degree of protection Material Mass Dimensions Data for application in connection with hazardous areas Certificate High pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF Wire size M12 diameter 3-6.5mm M20 diameter 10-14mm RTD/Bypass: (3) M12x1.5 K1, K2, SV1: 'P_C' (3) M20x1.5 Type 4X, IP66 Housing: 316 stainless steel Cable Gland: 316 stainless steel or Nickel Plated Brass Pressure Ports: 316 stainless steel Membrane Pad: Autotex F200XE O-ring: EPDM approx. 2.7 kg (6 lb) 165 x 124 x 90 mm (6.5 x 4.9 x 3.5 in) DEMKO 14 ATEX 1282X Marking II 3 G Ex ic ec nc [ic pzc] IIC T4 Gc (-20 C Ta 60 C) II 3 G Ex ic ec nc [ic pzc] IIC T6 Gc (-20 C Ta 40 C) II 3 D Ex ic tc [ic pzc, IIIC] IIIB T80 C Dc (-20 C Ta 60 C) (external version) II 3 D Ex ic tc [ic pzc, IIIC] IIIB T60 C Dc (-20 C Ta 40 C) (external version) II 3 D Ex ic tc [ic pzc] IIIC T80 C Dc (-20 C Ta 60 C) (internal version) II 3 D Ex ic tc [ic pzc] IIIC T60 C Dc (-20 C Ta 40 C) (internal version) Directive conformity Directive 2014/34/EU EN 60079-0:2012+A11:2013, EN 60079-11:2012, EN 60079-15:2010, EN 60079-2:2014, EN 60079-7:2015, EN 60079-31:2014 International approvals UL approval culus UL File E184741 Class I, Division 2, Groups A, B, C, D T4 (-20 C Ta 60 C) Class II, Division 2, Groups F, G, T4 (-20 C Ta 60 C) Class I, Division 2, Groups A, B, C, D T6 (-20 C Ta 40 C) Class II, Division 2, Groups F, G T6 (-20 C Ta 40 C) IECEx approval IECEx UL 14.0019X Ex ic ec nc [ic pzc] IIC T4 Gc (-20 C Ta 60 C) Ex ic ec nc [ic pzc] IIC T6 Gc (-20 C Ta 40 C) Ex ic tc [ic pzc, IIIC] IIIB T80 C Dc (-20 C Ta 60 C) (external version) Ex ic tc [ic pzc, IIIC] IIIB T60 C Dc (-20 C Ta 40 C) (external version) Ex ic tc [ic pzc] IIIC T80 C Dc (-20 C Ta 60 C) (internal version) Ex ic tc [ic pzc] IIIC T60 C Dc (-20 C Ta 40 C) (internal version) General information Supplementary information Accessories 5500-MAN-CDUL-* Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. 5500-MAN-CD01-* 5500-MAN-EX01-* EPV-5500 Vent System 5500 series purge and pressurization system vent 3

Dimensions - External Mounting 21 40 70 99 106 124 90 90 78 41 58 169 28 23 55 39.5 62 1 2 215 165 1 Low pressure port (atmostpheric pressure) 2 High pressure port (enclosure pressure) Dimensions - Internal Mounting 106 99 70 40 21 62 39.5 55 23 124 90 58 16 ø 6.4 x 3 90 215 168 110 28 169 1 Low pressure port (atmostpheric pressure) 2 High pressure port (enclosure pressure) 60.7 1 2 31 60 4

Type code/model number 5 5 0 0 - S S - I - V A C - P S C - L S C Housing Material SS 316 stainless steel Voltage requirement VAC 100 to 240 VAC VDC 20 to 30 VDC Mounting Configuration E External mounting I Internal Mounting Wiring entrance for power connection PSC (3) M20 stainless power cable gland PBC (3) M20 Nickel plated power cable gland PSH (3) ½"NPTF Stainless steel conduit entrance P No fittings or cable gland Wiring entrance for low voltage connection LSC (3) M12 Stainless low power cable glands (3) M12 Nickel plated low power cable glands L No cable glands Type of System Type Z & Ex pz, Zone 2 or 22, NEC Class I or II / Division 2 Typical Configuration Guide Certification Control Unit Vent Manifold UL 5500-SS-*-**- PSH a - LSC EPV-5500-**-*** 5500-MAN-CDUL-* 5500-SS-*-**- PSC- LSC ATEX/IECEx PBC- LSC EPV-5500-**-*** 5500-MAN-EX01-* a. A complete system consists of a control unit, a manifold and a vent. 5