Rectangular inlet air diffuser

Similar documents
Extract-air grille with ATK plenum box

LØV-R. Orion-Opus. Square supply diffuser

Square supply diffuser

Apartment ventilation

Apartment ventilation

Chilled beam for ceiling installation

VAV controller. TROX Auranor Norge AS. Telephone Fax

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

TBV - Terminal Unit. Halton TBV. Terminal Unit

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

Quick Selection Catalogue Version 6.1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

VARYCONTROL VAV Dual Duct Terminal Boxes

Conical diffuser KHAA TECHNICAL DATA

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Slot diffusers, Round duct diffusers. IMP Klima

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

REK, LEK, ROK AND LOK

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Lint separator FLARE

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Type VSD35. Nominal length up to 1500 mm: one spigot

For installation into ductwork

REK, LEK, ROK and LOK

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Ventiduct nozzle ducts

Ventilation grille Model AL

Ceiling swirl diffusers with perforated face plate

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Ceiling swirl diffusers with perforated face plate

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

CONSTANTFLOW Volume Flow Controllers

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Exhaust air diffuser HPKH + Plenum box ATTS

SDV Vane Swirl Diffusers

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Slot diffusers for ceiling installation

ROOF FAN ROOFMASTER STEC

Cell Ventilation Security Grille

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

DATASHEET PRODUCT CODE EXAMPLE:

Kitchen exhaust fan GLEB

Ventilation grille Model IB-R

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

LINEAR SLOT DIFFUSERS

Ventiduct nozzle ducts

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

CornerAir. CornerAir. Active chilled beam

ACOUSTIC CABINET FANS CVB / CVT Series

KTI Supply air valve. Product Facts. Product code example. Quick Selection

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

Pressure control damper ERPA

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

LINEAR SLOT DIFFUSERS

series KLR Linear slot diffusers

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

IMP Klima. Swirl diffusers. Variable swirl diffusers

ROOFMASTER STEF-ATEX ROOF FAN

Ceiling swirl diffusers

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Grilles Linear Grilles

series RVV Variable flow rate controllers

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Compact Grille Model KG

MULTIDIRECTIONAL DIFFUSERS WITH EXTRACTABLE CONES

CTVK Supply air diffuser

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

ILO, OLO, OLE and OLOi

ROOFMASTER STEF-HT ROOF FAN

DSC-PLASTER Slot diffuser for plasterboard ceilings

a partner to rely on

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Air diffuser system Model AUDIX -AW

Transcription:

GB0645 08.18 JBV LØV-R Rectangular inlet air diffuser Suitable for home ventilation Easy to install Detachable front face Documented with BVK plenum box Polyester sound insulation in box TROX Auranor Norge AS PO Box 100 NO-2712 Brandbu Telephone +47 61 31 35 00 Fax +47 61 31 35 10 E-mail: firmapost@auranor.no www.trox.no

APPLICATION These air diffusers are designed for comfort ventilation in all types of homes where balanced ventilation is installed, e.g. new builds or rehabilitated blocks of flats. They are designed for standard wall thicknesses with steel joists and a single sheet of plasterboard on both sides. DESIGN The rectangular JBV air diffuser consists of two parts: the mounting frame, with a spigot for the supply air duct, and a removable front face. No tools are required to install the diffuser face, and it can be easily removed for cleaning, etc. The diffuser face has separate grooves for control wires and measuring tubes. DIMENSIONS AND WEIGHT, JBV Dim D H Weight [kg] 100 99 147 0,7 125 124 147 0,8 160 159 202 0,9 Table 1 MATERIALS AND FINISH The diffuser's parts are made of galvanised sheet steel. The surface is painted standard white RAL 9003 - gloss 30. ORDER CODE, JBV JBV- 100 / 0 Product Dimension: 100,125 or 160 SL = Special paint Figure 1, JBV Example: JBV-100/0 Explanation: JBV diffuser dimension Ø100, standard paint RAL 9003 - gloss 30. ORDER CODE, BVK BVK - R - 100 Product: Produkt: R = Straight design V= Angle design Dimension Dimensjon intake innløp - utløp: outflow: 100-100, 125-125 eller or 160-160 Example: BVK-R-100 Explanation: BVK box with Ø100 intake and Ø100 outflow. 2

with BVK box APPLICATION A BVK plenum box is recommended because it provides better sound attenuation and control and measuring options. The BVK is a rectangular box with detachable sound insulation and a damper which provides access to the connecting duct. The damper can be locked in any position required. DESIGN The BVK comes in two designs, straight and angled. The sound insulation effectively dampens sound and releases no material fibres to the surroundings. The insulation can be removed for cleaning. The plenum box features a wire operated damper and measuring outlet for adjustment. DIMENSIONS AND WEIGHT, BVK Dim. D DA B H C Weight [kg] 100-100 99 102 154 154 116 2,9 125-125 124 127 154 154 116 3,1 160-160 159 162 189 189 132 3,3 Table 4 MATERIALS AND FINISH The BVK is supplied with a galvanised finish and polyester sound insulation. The spigot has a rubber EPDM seal. QUICK PICK, JBV with BVK-R box JBV BVK-R [m³/h] Dim Dim 25dB 30dB 35dB 100 100-100 65 79 90 125 125-125 94 108 122 160 160-160 130 151 162 Table 2: the table shows the air flow rate at the stated sound power level and 30Pa total pressure. Figure 2, BVK-R QUICK PICK, JBV with BVK-V box JBV BVK-V [m³/h] Dim Dim 25dB 30dB 35dB 100 100-100 61 76 86 125 125-125 83 94 108 160 160-160 115 133 155 Table 3: the table shows the air flow rate at the stated sound power level and 30Pa total pressure. Figure 3, BVK-V ORDER CODE, JBV with BVK JBV - K / 0 Product: SL= Special paint K - R - 100 Produkt: K = BVK kammer R = Straight design V = Angle design Dimensjon Dimension innløp intake - utløp: outflow 100-100, 125-125 or eller 160-160 Example: JBV-K-R-100/0 Explanation: JBV diffuser with accompanying BVK box, box with intake dimension Ø100 and outflow/diffuser dimension Ø100. Diffuser painted with standard RAL 9003 - gloss 30. 3

ACOUSTIC DOCUMENTATION The diagram provides a summary of the A-weighted sound power level from diffuser, L WA. The correction factors in table 5 will be used to calculate the emitted frequency-distributed sound power level, L W = L WA + KO. A room with absorption equivalent to 10 m² Sabine will have a sound pressure level which is 4 db below the sound power level emitted. Table 5 provides the correction factors (KO) for conversion to the diffuser's emitted sound power level to ducts in the various frequency bands. Correction factors are provided for both open and closed damper, i.e. for the right and left pressure loss curve in the diagram, respectively. Correction factors for intermediate points are interpolated between these. The sound power for different frequencies is calculated using the following formula: L W = L WA + KO der L WA is recorded db(a) level in the diagram. Acoustic properties are measured in accordance with international standards for precision measurements of sound pressure, ISO 3741 and 5135. CALCULATION DIAGRAM Diagram 1, JBV with BVK-R Ø100 Diagram 2, JBV with BVK-V Ø100 Diagram 3, JBV with BVK-R Ø125 Diagram 4, JBV with BVK-V Ø125 4

Diagram 5, JBV with BVK-R Ø160 Diagram 6, JBV with BVK-V Ø160 Correction factor [KO] JBV with BVK box JBV BVK-box KO [db] Dim Type Dim 63 125 250 500 1k 2k 4k 8k 100 BVK-R 100-100 -2-5 -5-2 0-1 -11-18 100 BVK-V 100-100 1-2 -3-2 0-2 -12-16 125 BVK-R 125-125 6-6 -6-2 0-2 -10-17 125 BVK-V 125-125 5-3 -5-1 1-3 -11-17 160 BVK-R 160-160 5-3 -5-5 -5-6 -9-22 160 BVK-V 160-160 5-5 -5-3 -5-8 -11-22 Table 5 Static sound attenuation incl. end reflection JBV with BVK box JBV BVK-box Self-attenuating[dB] Dim Type Dim 63 125 250 500 1k 2k 4k 8k 100 BVK-R 100-100 19 20 15 12 6 11 12 17 100 BVK-V 100-100 17 18 17 15 13 17 18 15 125 BVK-R 125-125 20 16 13 10 6 9 10 15 125 BVK-V 125-125 18 14 12 12 10 14 15 16 160 BVK-R 160-160 16 11 10 9 9 11 13 15 160 BVK-V 160-160 15 12 11 10 9 13 14 15 Table 6 THROW LENGHT Diagram 7, JBV throw lenght 5

MOUNTING The JBV diffuser has a rubber seal and is easily installed in the connection and attached with screws in the diffuser's mounting frame. The BVK box has mounting brackets with slots that are adjusted and attached in the most appropriate way. ADJUSTMENT The diffuser face must be attached during adjustment. The measuring tube and adjustment wire are extracted through the groove in the face. The damper is secured by using a clamping nut on the wire, tighten the clamping nut properly so the damper not change position. K-factors for calculating air volume are on the label in the diffuser, or in our adjustment guide on our website www.trox.no. MAINTENANCE The diffuser face and sound insulation can easily be removed for cleaning. ENVIRONMENT Inquiries regarding the product declaration can be directed to our sales team, or information can be found on our website: www.trox.no JBV is developed and produced by: The company reserves the right to make amendments without prior notice. www.tintkom.no Head office: TROX Auranor Norge AS, P.O. Box 100, 2712 Brandbu Tel.: +47 61 31 35 00 Fax: +47 61 31 35 10 www.trox.no