INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Similar documents
INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

ISLAND RANGE HOOD SPECIFICATIONS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

INSTALLATION INSTRUCTIONS

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

Viking Installation Guide

UNDER CABINET RANGE HOOD SPECIFICATIONS

Viking Installation Guide

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

Installation Instructions

NUTONE RANGE HOOD NTM SERIES

Pro Island Ventilation Hoods

Installation Instructions

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Type of Motor & Blower

Designer Wall Range Hood Installation. Installation Tutorial Video

FADE Series Wall Axial Fans

Hood. warning. warning. caution

WhispAire Range Hood Quiet Hood

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

! FOR DOMESTIC COOKING ONLY!

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

Viking Installation Guide

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Self-Cleaning Range Hoods

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

HP190SL Series Slimline Radon Fans

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

Viking Installation Guide

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Installation. Professional Indoor & Outdoor Hoods

All (-4) Models 390CFM Code Compliant

Filtered Kitchen Supply Packaged Ventilator

Viking Installation Guide

www. TheRangeHoodStore.com

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

KEES, INC. BALANCING MANUAL

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

WhispAire Range Hood Quiet Hood

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

IMPORTANT SAFETY INSTRUCTIONS

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Safety & Installation Instructions

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Ventilation Solutions

VENT FLASHINGS GALVANIZED STEEL

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments

Installation Instructions

! FOR DOMESTIC COOKING ONLY!!

CEILING & INLINE/CABINET VENTILATORS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Viking Installation Guide

SQUARE INLINE CENTRIFUGAL FANS

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODEL FF50 CEILING FAN

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

INSTALLATION INSTRUCTIONS

Multi-Port Centrifugal Fans for Round Duct

Transcription:

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK Page 1 C U L R US

Ducting Do s and Don ts General Requirements Observe local codes regarding special duct requirements and placement of duct against combustibles. Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. Blower Requirements The island dual blower unit (T200) requires round duct or equivalent (50 square inches), and the island cluster blower unit (T400) requires round duct or equivalent (113 square inches). Blower Combined Duct Dize Sq. Inch Area Vent-A-Hood Transition Island Dual (T200) 8" round or equivalent 50 sq. in. VP565 (Included) Island Cluster (T400) 12" round or equivalent 113 sq. in. VP564 (Included) Ducting Requirements NEVER reduce the duct size. When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined. Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Termination Requirements Airflow must not be restricted at the end of the duct run. A wall louver or roof jack is required for each duct run. Every wall louver or roof jack must include a gravity damper to prevent back drafts. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. YES Smooth Duct Smooth Gradual Turn Proper Combining of Two Ducts NO Flexible Duct Sharp Angled Turns Page 2 Improper Combining of Two Ducts

Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing the TSLE/TPSLE island liner, it is recommended that the bottom edge of the liner be located no more than 30 above the cooking surface for optimum performance. For custom liners, the recommended height off the cooking surface is dependent on the depth of the liner. In general, the deeper the custom liner, the higher off the cooking surface it can be, up to a maximum recommended height of 30 above the cooking surface for optimum performance. 3) Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus 1. This will allow the transition to engage 1 inside the duct. Consult the connection diagrams (on next page) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is included on the back page of this instruction sheet. Transition heights are as follows: Island Dual Blower (T200): Island Cluster Blower (T400): round duct connects to 9 tall VP565 transition (included). round duct connects to 11 1/4 tall VP564 transition (included). 4) Remove the liner from its packaging and place it on the floor or countertop for access to the inside of the liner. Remove, open, and save the liner trim kit from the packaging. The liner trim kit will be used later in Step 10. Page 3

Installation Details Continued 5) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (one on each side of the housing). The housings should be pulled forward and gently tipped to clear the blower wheels and then out of the hood. 6) Remove the three screws retaining the blower motor(s). Unplug and remove the motor(s), taking care not to damage the blower wheel(s). It is not necessary to remove the blower wheel from the motor. TSLE Connection Diagram (3-4 Widths) Of Hood ¾ Of Hood 2 1 5 x 1 Exhaust Opening 8" Round 8" Round 9" 9" Electrical Vent Holes Transition Opening 9 Above Top 5" 16" 12" 550 T200 Dual Blower (Top View) VP565 Transition (Included) Transition Installed (Side View) TPSLE Connection Diagram (4-6 Widths) 1 ¾" Blower Outlets Electrical (2) Vent Holes 12" Round 12" Round 5 ½" 11 1/4" 12" Transition Opening 11 ¼" Above Top 10 ½" 11 ¼" 12" 8" Round 8" Round 8" Round 1100 T400 Cluster Blower (Top View) VP564 Transition (Included) Transition Installed (Side View) Page 4

Installation Details Continued Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 7) Install an appropriate 1/2 UL listed electrical wire clamp through each motor box electrical opening on the top of the liner. Install electrical wiring from the service panel to the liner location for each motor box. Consult the connection diagrams (above) for further details on electrical placement. Model Volts Amps Hz RPM SP@0.0" Equivalent SP@0.1" SP@0.2" SP@0.3" Minimum Round Duct Size T200 Island Dual 115 4.0 60 1550 550 900 507 471 431 8" (50 in. 2 ) 6.0 T400 Island Cluster 115 7.5 60 1550 1100 1800 998 855 774 12" (13 in. 2 ) 6.4 Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute () requirements and can deliver equivalent much more efficiently than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the Equivalent. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. 8) Extend wires to the liner and insert them into the electrical wire clamp on each motor box. Tighten the wire clamp(s). From inside the liner, using UL listed wire nuts, attach the neutral wire(s) to the white lead(s), the hot wire(s) to the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es). Warning: Do not operate hood without proper ground connection. 9) Install transition in the exhaust collar(s). Seal connection with duct tape. Note: The transition must engage inside the exhaust collar. While aligning the duct connection and guiding the wires, lift the liner up into the enclosure flushing the bottom edges of the liner and the enclosure. Duct and transition should connect together as the liner is raised into place. Wood strips may be necessary to fill any gaps between the opening and the liner if the opening in the wood surround is larger than the liner. Sones # 10) Install a wood screw with a countersunk washer and a flat washer into each mounting hole along the bottom edge of the liner. Note: The hardware used in this step can be found in the liner trim kit that was previously removed from the packaging in Step 4. 11) Install the trim piece for the back and front of the liner (provided in the liner trim kit) by hooking one side under the bottom edges of the back countersunk washers. Snap the trim piece over the top of the countersunk washers by applying pressure upward and toward the liner wall. Repeat this process for the side trim pieces (provided in the liner trim kit). Note: It may be necessary to lightly tap the trim piece with a rubber mallet. Trim Piece Liner Trim Kit Flat Nylon Washer Wood Screw Countersunk Nylon Washer 12) Plug the motors into the liner and reinstall the blower motor retaining screws that were previously removed in Step 6. Note: The side of the motor box where the black motors mount is labeled to ensure the motors are installed back into the hood in the proper position. 13) Replace the blower housings and the blower shields. Make sure that the dampers open and close smoothly. 14) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly. Page 5

VENTING WALL LOUVER WALL LOUVER WALL LOUVER ACCESSORIES RECTANGULAR WALL LOUVER 8 5 Back View 1 ½ Flange Back View 1 ½ Flange 13 13 Back View 1 ½ Flange 8 ½ 1 ½ FLANGE 2 FLANGE VP526 VP527 VP528 Round Round Round (MAXIMUM 4/12 PITCH) VP554 Round (MAXIMUM 4/12 PITCH) VP555 Round (MINIMUM 4/12 PITCH) VP538 VP560 x 8 ½ x (MINIMUM 4/12 PITCH) 6 ½ 22 ½ 10 ½ 6 ½ 22 ½ 10 ½ 20 ¾ 20 ¾ VP539 Round VP540 Round VP541 Round ADJUSTABLE ELBOW VP513-8 ½ VP514-9 9 1 VP515-10 5 VP552 VP553 Round Round BACK/SIDE VENT ELBOW 8 ½ VP539-HP Round VP540-HP Round VP541-HP Round x BACK VENT ELBOW 14 4 ¼ VP552-HP VP553-HP x TO TRANSITION Round Round 7 ½ VP513 Round VP514 Round VP515 Round MULTI-BLOWER TRANSITION Round 1 VP561 to x 8 ½ M1200 STANDARD TRANSITION VP559 x STANDARD ISLAND TRANSITION VP521 x to CLUSTER BLOWER TRANSITION VP562-17 ½ VP563-16 ½ 9 9 11 ¼ VP562-2 VP563-30 ½ VP562 VP563 & to & to 21 VP566 21 x to 1 5 VP565 5 x 1 to 18 ½ VP564 & to OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND BLOWERS 19 OFFSET KIT - ROUND OFFSET KIT - RECTANGULAR 10 ½ VP542 VP543 5 1 Top Left Top Right VP544 VP545 1 5 Left Side Right Side VP529 1 Rnd to Rnd 1 VP550 Rnd to x Y TRANSITION ROUND DUCT PIPE RECTANGULAR DUCT PIPE RECTANGULAR DUCT PIPE 1 3 30 1 24 8 ½ VP517 VP518 VP551 & to & to & to VP500 VP501 VP502 Round Round Round VP504 VP505 VP506 x x x 1 VP507 x 8 ½ Page 6