DISPENSING VALVES ADJUSTMENTS

Similar documents
INSTALLATION INSTRUCTIONS

UF-1 AND UFB-1 VALVES TRAINING MANUAL

VARIETY VALVES for Servend Beverage Dispensers

BE 20 IMI Cornelius Orange Juice Dispenser Model Quest Elite QLT 2000

INSTALLATION INSTRUCTIONS 464, 424 & 324 POST-MIX VALVES

LEVER SELF SERVE PORTION CONTROL OPTIFILL

Volumetric Post-Mix Valve

3200NT Timer Service Manual

UF-1 AND UFB-1 POST MIX-DISPENSING VALVE ILLUSTRATED PARTS LIST

FLAVORFUSION. Training Manual

PowerLevel s e r i e s

C UF-1 FAST FLOW POSTMIX VALVE W/STAND 3" LEVER 1 EA $203.67

3 Phase Smart Controller

Terex Utilities. Issue: Action:

i n s t r u c t i o n m a n u a l

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

Self-Testing Industrial Series

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

COLDFUSION WITH COLD CARBONATION

Installation and Operations Manual

COLDFUSION. Operator s Manual

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Spectron Industrial Series

An ISO 9001:2008 Registered Company

SCHEMATIC AND ROUTING DIAGRAMS

GTWY515, GTWY516* Fast Idle, Shift Interlock, I/O Ford Transit Introduction

HL610-B Fast Idle, Lift Interlock Chevy 610 Van 6.0L and 6.6L Contact InterMotive for additional vehicle applications

DISCONTINUED VERSION The information in this manual is no longer current.

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

7281-EA/ET INSTRUCTIONS

GTWY505 Fast Idle, Shift Interlock, I/O Ford E-Series

THE witech SOFTWARE LEVEL MUST BE AT RELEASE OR HIGHER TO PERFORM THIS PROCEDURE.

5 Operation 5.1 DESCRIPTION

TRI-GRAIN MOISTURE TESTER OVVNER'S MANUAL

OP-500 On-Premise Series Instruction Manual

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

Rally computer 3 Rally computer 3.GPS *

OWNER'S MANUAL & INSTALLATION INSTRUCTIONS 6500 Series

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Installation Instructions & Users Manual

The Leaky Tree. Alex Bratschun. Jeff Gier. Cassie Hellem. Ryan Stephens

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

SAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE

WTEC III SHIFT SELECTOR

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

" MANUALLY OVERRIDING YOUR SYSTEM

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

LASER ENHANCED SEMI-AUTOMATIC GRIP OWNER S MANUAL RED LASER GREEN LASER

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Convenience Features MEMORY FUNCTION

CF-10 Option Operating Instructions

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

1. Disclaimer Warnings Introduction Display and Commands... 5

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

ULTRA LEVEL MOTORIZED LEVELING

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Stryker Smart Pump Preventative Maintenance Procedure

ILLUSTRATED PARTS LIST

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

GL1200T Cut & Seal. (GL1200 Seal only)

Models Affected: Certain 2014 Model Year Vision Buses Equipped with Ford 6.8L Propane Engines ISSUE

Iron Gate Feed Pump Manual

ATS-9600/9700 TABBER/LABELER

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

SUBJECT: EB e-stroke GEN 3 Post Install Functionality Test

CRUISE CONTROL SYSTEM

System 3 ZB1PS Device Chassis. Operator s Manual

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

TECHNICIAN GUIDELINES

CA611 Owners Manual CAUTION!

TOYOTA RAV TVIP V5

CONTROLLER DIAGNOSTIC GUIDE

AUTOMATIC LUBRICATORS & LUBRICATION

Model PRO-9675FT4 Owner's Manual

DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

5000TOC Sensor Service Manual

Model APS-920 Owner s Manual

IDEAL Stripmaster Model 950 Wire Stripper #45-950

TS1251 PRESSURE DISPENSER USER'S MANUAL

Figure 1. AirChek XR5000 Air Sample Pump

G - TESTS W/CODES - 2.2L

Operation Guide. Hydraulic Leveling Systems #2000, #2010, #3000, and # Table of Content. Introduction

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Section of 14. Ice and Rain Protection

Dielectric Withstand Tester

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Doc: MGA-µS Version: 1.0 Page 2 of 6

Installation, Operation and Maintenance Manual

Transcription:

DISPENSING VALVES ADJUSTMENTS NOTE: Adjustment instructions for other then Cornelius manufactured SF-1 and the UF-1 dispensing valves, contact the dispensing valves manufacturer. SF-1 AND UF-1 DISPENSING VALVES ADJUSTING WATER FLOW RATE NOTE: Some dispensing valves are equipped with water flowasher- type water flow regulators (see Figure 1) that dispense water at a fixed rate and are non-adjustable. Perform the following to adjust the adjustable water flow regulators for dispensed water flow rates. UF-1 Dispensing Valves. Adjusting screw stops are built into the valves to prevent leakage when the screws are adjusted clockwise too far. Stop adjusting clockwise when turning resistance increases. Turn the adjusting screw counterclockwise 1-1/2 turns after the stop is contacted. Turn dispensing valve water flow regulator adjusting screw (see Figure 1) to the left (counterclockwise) no more than 1/4 turn at a time to decrease water flow rate or to the right (clockwise) no more than 1/4 turn at a time to increase water flow rate. ADJUSTING WATER-TO-SYRUP RATIO (BRIX) OF DISPENSED DRINK IMPORTANT: On dispensing valves equipped with an adjustable water flow regulator (see Figure 1), make sure water flow rate is adjusted to your requirement before adjusting the syrup flow regulator for Water-To-Syrup Ratio (Brix) of the dispensed drink. Adjust Water-to-syrup Ratio of dispensed drink by using Ratio Cup (P/N 311100000) and Syrup Diversion Tube Assembly (P/N 319540000). 1. Remove dispensing valve cover. 2. Install syrup diversion tube on the dispensing valve by pushing rubber end of the diversion tube up on baffle inside the nozzle. WATER FLOW WASHER OR ADJUSTABLE WATER FLOW REGULATOR SF-1 DISPENSING VALVE ADJUSTABLE SYRUP FLOW REGULATOR WATER FLOW WASHER OR ADJUSTABLE WATER FLOW REGULATOR UF-1 DISPENSING VALVE NOZZLE ADJUSTABLE SYRUP FLOW REGULATOR SYRUP DIVERSION TUBE ASS Y (P/N 319540000) WATER CHAMBER SYRUP CHAMBER RATIO CUP (P/N 311100000) Counterclockwise to Decrease Clockwise to Increase FIGURE 1. WATER-TO-SYRUP RATIO (BRIX) ADJUSTMENT 1 TD 281

NOTE: Refer to syrup Manufacturer s recommendations on the syrup package for Water-To-Syrup ( Ratio ) Brix of the dispensed drink. 3. Hold container under the dispensing valve. Activate dispensing valve and dispense just enough to fill the syrup diversion tube with syrup. 4. Hold large chamber of the ratio cup under dispensing valve nozzle. Place free end of the syrup diversion tube into the syrup chamber marked for proper ratio. Activate the dispensing valve and dispense approximately six ounces of water into the ratio cup. Water and syrup levels should be even in the ratio cup. 5. If water and syrup levels are not even in the ratio cup, turn the dispensing valve syrup flow regulator labeled SYRUP adjusting screw to the left (counterclockwise) no more than 1/4-turn at a time for less syrup or to the right (clockwise) no more than 1/4-turn at a time for more syrup. 6. Repeat Water-to-Syrup Ratio test and adjust the syrup flow regulator as many times as necessary until proper ratio of the dispensed drink is achieved. 7. Remove syrup diversion tube from the dispensing valve. 8. Install dispensing valve cover. ADJUSTING SF-1 DISPENSING VALVE CODED AUTOSET PORTION CONTROL (see Figure 2) NOTE: The drink size switches S (SMALL), M (MEDIUM), and L (LARGE) must be momentarily depressed, then released before dispensing of drink will occur. The drinks may be manually dispensed by pressing cup or glass against the dispensing valve lever should the portion control module become inoperative. The CANCEL/POUR switch may be used for three separate dispensing functions as follows: A. The portion control drink may be cancelled by momentarily depressing and releasing the CANCEL/POUR switch. DO NOT HOLD SWITCH IN DEPRESSED POSITION AS THE DRINK WILL NOT CANCEL AND DISPENSING OF DRINK WILL CONTINUE. B. The CANCEL/POUR switch may also be used to dispense a non-portion controlled drink by merely depressing and holding the CANCEL/POUR switch until the desired drink has been dispensed, then release the switch. C. Press the CANCEL/POUR switch to return to the operational mode after all portion size adjustments have been completed. The blinking LED light will go out. 1. Have a sample of your small, medium, and large size cups with appropriate quantity of ice, if used, already in the cups. SMALL MEDIUM LED LIGHT LARGE FIGURE 2. AUTOSET PORTION CONTROL ADJUSTMENT 2 TD 281

2. Simultaneously, press and hold the S (SMALL) and L (LARGE) buttons on the Coded Autoset Portion Control Module until the LED light in the center of the module starts blinking. Then release the buttons. The blinking LED indicates the set mode is active. 3. Place the small cup under the dispensing valve to be adjusted. Press and hold the S (SMALL) button until the cup is filled to the desired level, then release the button. This procedure programs the small size drink into the Coded Autoset Portion Control. 4. Repeat Step 3 for the Medium and Large drink size drinks. Repeat for all valves. 5. After programming the Small, Medium, and Large size drinks, press and release the CANCEL/POUR switch to return Coded Autoset Portion Control to the operational mode. The blinking LED light will go out. Note: This Coded Portion Control module has a permanent memory and will retain the portion adjustment until readjusted, even without electrical power applied. PROGRAMMING UF-1 PORTION CONTROL DISPENSING VALVE (see Figure 3) Use the programming mode to set the portion size of the dispensed drinks to the desired settings as follows: To enter the programming mode, the following criteria must be met: 1. There is no active dispensing cycle in progress. 2. The OUT display is inactive. The valve input voltage is within normal operational limit (20.5 VAC to 27.5 VAC). NOT VISIBLE UNLESS ILLUMINATED CANCEL/POUR HIDDEN SWITCH FIGURE 3. ADJUSTING UF-1 PORTION CONTROL Accessing Programming Mode. 1. Without interruption, press and hold the HIDDEN SWITCH for 3-seconds When you have entered into the program mode, the PGM LED will be illuminated. While in the programming cycle for any dispensing size, the PGM LED will flash. NOTE: On the portion control module, the PGM/OUT displays are not visible unless they are illuminated. This is similar to the dashboard warning lights on automobiles. They are shown here to identify their location. 3 TD 281

PROGRAM MODE STEPS 1. Place appropriate size cup (with the desired amount of ice) under the dispensing valve nozzle. 2. Press and hold the desired portion switch until the liquid/foam level reaches the desired cup level. NOTE: While in the programming mode, the PGM LED will be illuminated. While pressing a portion switch, the PGM LED will flash. 3. Release the switch storing the pour time value in memory. The PGM LED will stop flashing and return to a steady illumination. 4. Programming steps for this drink size are now complete. Repeat steps 1 through 3 for each drink size to be programmed. NOTE: Any drink size may be programmed as many times as desired before exiting the program mode. It is not necessary to adjust all cup or glass sizes while in the program mode. EXITING PROGRAMMING MODE 1. Press and hold the HIDDEN SWITCH for 3-seconds. When you have exited the program mode, the timer values stored in temporary memory will be written to permanent storage and the PGM LED will go off. RESTORING FACTORY SETTINGS 1. To restore to the factory setting while in the program mode, press and hold the CANCEL/POUR switch. Then, at the same time, press the desired dispensing size switch. The factory programmed setting is now restored. 2. Repeat for each drink size to be restored to the factory programmed setting. PROGRAMMING TOP-OFF DELAY TIME NOTE: The Top-Off Delay Time has been factory set at 4.0 seconds but may be field adjusted through the program mode. You may enter the programming mode under the following conditions: 1. The dispensing valve is not dispensing. SET SWITCH PROGRAM LED (ONLY VISIBLE WHEN LIT) PROGRAM SWITCH FIGURE 4. PROGRAMMING TOP-OFF DELAY TIME 4 TD 281

TO ENTER PROGRAMMING MODE 1. Press the PROGRAM SWITCH for 3-seconds until the LED (light) turns on. The valve is now ready for programming the top-off delay. PROGRAMMING TOP-OFF DELAY TIME Only the top-off delay is adjustable. Use top off adjustment mainly for drinks that are foamy, such as diet drinks. To adjust the top-off delay, follow these programming steps: 1. Place an appropriate size cup (with the desired amount of ice in the cup) against the valve lever causing the valve to begin dispensing. When foam or liquid touches the lever, the valve will automatically stop dispensing. This is the initial pour. The cup must remain in place with the valve lever pressed. The LED (light) will flash at this time. 2. If you want to continue programming the top-off delay time, skip step 3 and proceed to step 4. 3. If you do not want top-off delay time, remove the cup from against the valve lever. This will enter a zero value for the top-off delay time and will inhibit a top-off pour. When finished, exit program mode by pressing the PROGRAM SWITCH for 3-seconds until the LED (light) turns off. 4. When foam in the cup has lowered, press and release the SET SWITCH. The valve will begin dispensing and will stop when the foam or liquid touches the lever. This is the top-off pour. The time between the end of the initial pour and when the pour is re-started is the top-off delay and it is now programmed into the valve. The LED (light) will be on steady at this time. 5. When the valve stops pouring the second time, the cup may be removed and you may exit the program mode by pressing the PROGRAM SWITCH for 3-seconds until the LED (light) turns off. The top-off delay is now programmed into the valve. 6. When the valve stops pouring the second time, the cup can be removed and you may exit the programming mode. The top-off delay is now set. EXITING PROGRAM MODE To leave the programming mode, press and hold the PROGRAM SWITCH for 3-seconds. 5 TD 281