UPS24 application instruction

Similar documents
User Manual. User Manual IQ 328+

User Manual IQ338. We thank you that you have decided to purchase our intelligent charger.

Relay Retrofit Program Cutting Tool Safety Guide

INTRODUCTION. Specifications. Operating voltage range:

Documentation. RM-BV4 Micro DP. Filter control

User Manual. User Manual IQ338XL

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

Electronic Ballast EVG 2000-T

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

User Manual Solar Charge Controller 3KW

BATTERY CHARGER Instruction Manual

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

MAGPOWR Spyder-Plus-S1 Tension Control

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

BMS16T BMS24T. Thanks for your purchasing the BMS16T or BMS24T for your vehicle.

BATTERY CHARGER RS-1000 Instruction Manual

WT6000. Wearable Terminal Quick Start Guide MN

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Leica GKL221 Charger User Manual

Power Guide. TimeMate /OPEN OK 2.78 ToGo 001:45: Flexible and reliable power system

OPERATING INSTRUCTIONS

SmartON / SmartON+ Installation and Use Manual

ENGINE PROTECTION BOARD PDM1

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

General Purpose Relay

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

Instruction of connection and programming of the VECTOR controller

Updated: October 2012

MODEL PS-4 DIGITAL PORTION SCALE

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Instruction Manual BALANCE CHARGER/DISCHARGER FOR NICD/NIMH/LITHIUM/PB BATTERIES

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

Mounting and Operating Manual Non-Return valves Swing-Check valves

Digital Pressure Regulator Sentronic PLUS Series 614

RU BMS Power Supply and Battery Management System Owners Guide

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

General Description. BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management

Battery Charger Series EASY Charger

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

UP100AC INSTRUCTION MANUAL

Operation Manual. Kino Flo/BlockBattery

Battery Charger. Series EASY Charger. User s manual

Learning Objectives:

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

SPOTLIGHT 30 MILLION CANDLEPOWER

HIGH POWER SOLENOID DRIVER 1

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

User Manual. Solar Charge Controller 3KW

HP Adjustable Depth Fixed Rail Kit Installation

Intelligent NiMH/NiCd/Li-ion Charger TN456

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

DV2003L1. Fast Charge Development System. Control of On-Board Linear Current Regulator or External Current Source. Features. Connection Descriptions

Operating instructions

Sinewave Inverters. SWING 150VA and 300VA. User s manual

NEC Energy Solutions ALM 12V35 Batteries with

Specifications. Special features

Super PWRgate PG40S Spring City Drive Waukesha, WI

Modular Solar Controller / Charger (Patent Pending)

80W. Operating Manual. Dual Power. Intelligent Balance Charger LiPo/LiFe/LiIon: NiMH/NiCd: Pb: Charge Power: Charge Rate: Discharge Rate:

User's Guide of BST-360 Battery System Tester. BST-360 Battery System Tester User's Guide 1 / 15

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Operating Instructions Inline Detonation Flame Arrester and

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

Pure Sine Wave Inverter Charger

CBI All in One DC UPS Power Solutions

OPERATING MANUAL. Wind / Solar Hybrid - Charge Controller 24V 1000w. i/hcc Charge Controller

Battery Management System (BMS) Installation guide and manual

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

All In one uninterruptible power supply solutions

Installation instruction Sound Booster Pro Active Sound

Installation Manual Model 3800/3810

Operating instructions Flow monitor SI / / 2014

Installing the Switch Chassis

Overview Overvoltage protection

EZ SDI TM Booster Pump Assembly

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

TomTom-Tools GmbH Zelgli 20 Phone: Arni

Fast Charger SL01/02

MSR01. Water heating controller with solar panel support

FEATURES Charges two 6- to 8-cell NiCd/NiMH battery packs simultaneously Fully automatic operation Multi-color LEDs indicate state of charge at a

Model C230 Pump Controller

MIC4 IGNITION CONTROLLER

MAX712 Linear-Mode Evaluation Kit


Turnigy FATBOY 8. User s Guide. Copyright 2012 Hobby King 01/18/2012

DV2000S1 and DV2000TS1

Preparing and programming of ESGI 2 LPG supply system manual

when it comes to quality! BMR GmbH 1

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Moisture meter. Operators manual

Transcription:

HIQEL GmbH Page 1 PS24 application instruction Description In some applications a supply to system parts is necessary even during a supply breakdown. You maybe have to save machine run time data or system parameters when a supply breakdown occurs. If you use a short message unit you might even have to send a SMS containing the breakdown information. For all these and many other applications you can use the PS24 to secure the power supply throughout the breakdown. The PS24 (ninteruptable Power Supply 24V) offers a supply voltage of 24VDC, with an AC adapter of 24VDC, without interruption. Mounting 38,5 45 A 65 The PS24 switches from a current of 24VDC from the mains to a storage-battery voltage, simultaneously there is a electronic charger available for the storage-battery (accumulator). The electronic is placed within a 22,5mm wide plastic box for DIN rail mounting. 22,5 85 The accumulator (Akku-Pack) is placed outside of the PS24 and is connected directly to the PS24. For easy installation this component is also ready for DIN rail mounting. The accumulator has short ended leads, so you have to place it next to the PS24. 40 control elements PS24 S1 42 95 Front panel with displays and On the front side of the PS24 you can find five LED and one button. The LED are hidden behind the front panel, so you can just guess where they are by symbols on the front panel. ninterruptable Power Supply The button just juts out a few millimetres. That way an unintentional activation and a damage during installation can be avoided.

HIQEL GmbH Page 2 Element external supply available S1 button for switching on the voltage output status display accumulator active no external supply available or too little voltage voltage breakdown at the accumulator Wiring The figure on the left shows the provided wiring. Terminals "M-" and "A-" are connected inside of PS24 and have the same level. Pay attention to this, if you want to disconnect the accumulator from the load with input "" and a external potential has to be injected here. The supply from an external AC adapter has to be connected with terminals LIN" and "M-". For the connection of the accumulator use terminals "A" and "A-". Wire those devices which need an interrupt free supply with terminals "LOT" and "M-". messages or accumulator status. se terminals C, 14 and 24 for supply status If you want to disable the supply by the accumulator, you have to connect 24VDC with terminal. Terminal LIN Description voltage input, external supply connect the output of a 24VDC adapter to this terminal. M- reference potential A positive pole of the accumulator A- negative pole of the accumulator input to disable the accumulator supply LOT voltage output M- reference potentiall C common terminal for both output signals 14 output signal terminal 14 voltage supply too little or breakdown 24 output signal terminal 24 accumulator voltage near breakdown

HIQEL GmbH Page 3 Accumulator (storage-battery) If a breakdown of the external 24VDC supply occurs the accumulator will maintain the power supply. The switch happens automatically and without interruption. With continuing life-span, the capacity of the accumulator also sinks. This is very strong influenced by the ambient temperature, the environmental conditions and the load cycle. Therefore you can give no exact statement about the waste graph. Because of safety reasons it is recommended to test the accumulator once a year. From experience you should change the accumulator every five years. If the AKK-PACK doesn t meet your desired expectations, you can connect a different accumulator to the PS24. To avoid problems refer to the technical informations for accumulator loading and power rating of the PS24. You can use any NiCd and NiMH accumulator with capacities beween 50mAh and 500mAh. Testing the accumulator se a very easy connection to find out about the capacity of the accumulator. Take a look at the figure on the left. S1 is a button or a jumper and K1 is a 24VDC-relay (coil voltage between 10 and 50mA). To startup active S1 briefly. In this period of time, the coil of the relay will be passed through by power and K1 brings the circuit to a self-hold state. Now just the time must only be measured. The capacity of the accumulator can now be calculated approximatively with the following formula: t time in seconds (relay activated) R coil resistance capacity in mah = t/(r*150) Please note that the capacity of the accumulator is also influenced by the load. The less the resistance of the relay is, the less is the accumulator capacity. This effect cannot be influenced. The advantage of this circuit is the deep discharge protection of the accumulator, because K1 falls if the accumulator voltage falls below a certain value. Note that the relay falls at the latest at a voltage of 8VDC below the holding voltage. Maybe it is necessary to connect two relays serially to get this effect. Accumulator load The loading of the accumulator happens independent. For example, if the supply falls below 20V, the accumulator will be activated and simultaneously loaded. To make this possible, the PS24 has an own voltage increase circuit with current and voltage limiting.

HIQEL GmbH Page 4 Switch from AC mains supply to accumulator supply If the external supply falls below 20VDC, the accumulator will be activated. Because of possible jumpers the device will only switch back to AC mains supply if the external supply reaches 22VDC again. Status message accumulator voltage The discharging graph of a NiCd-accumulator is very flat, only when the capacity comes near an end it steeps. Now it depends on the current taken out how quick the voltage falls. There is one status LED and one status output to detect this instant. Both status signals become active at an accumulator voltage between 18VDC and 22VDC. If the voltage falls below 18VDC at the accumulator, the accumulator service will be disabled in order to avoid a deep discharge. Activate accumulator service In some cases you could have to activate the accumulator manually, for example if the PS24 has been just connected and no external supply is available. Activate the accumulator with button S1 at the front side of the PS24. The accumulator will not be active if the voltage is below 22VDC. Disable accumulator service You can save accumulator capacity by setting input. This is very useful if breakdowns occur more often and the accumulator cannot be charged within the available time. Status messages L IN A A- S1 L OT M- M- 14 C 24 Message external supply available Note: There is no information about the level of external supply. status display If input is activated, the status message will become active. Note: The display will be active very briefly (0,1s) if you disable the accumulator service. accumulator active The output will be supplied by the accumulator. No external supply available or too little voltage A failure of the external supply will be displayed here. accumulator voltage breakdown The display becomes active shortly before the breakdown occurs. Terminal 14 The connection C at 14 is simultaneously active with. Terminal 24 The connection C at 24 is simultaneously active with.

HIQEL GmbH Page 5 Technical information Data PS24 Accumulator Supply voltage 24VDC 24VDC Supply voltage range 18VDC < in < 30VDC Nominal current drain < 25mA Accumulator type NiCd Rated capacity 110mAh Operating temperature 0 C < temp < 60 C 0 C < temp < 45 C Storage temperature -30 C < temp < 70 C -30 C < temp < 50 C Switchover voltage from AC mains supply to 20VDC /-1V accumulator supply ("LIN" - "M-") Switchover voltage from accumulator supply to 22VDC /-1V AC mains supply ("LIN" - "M-") Accumulator deep discharge protection ("A" - 18VDC /-0,5V "A-") Accumulator minimum voltage ("A" - "A-") 22VDC /-1V Charging current for the accumulator (you can find the typical charging graph below) ("A" - "A-") < ("LIN" - "M-")? --> [("LIN" - "M-") - ("A" - "A-")]/400 ("A" - "A-") < 28V? --> ~9mA Switching voltage terminal C to 14 Switching voltage terminal C to 24 Switching current terminal C to 14 Switching current terminal C to 24 0,5VDC < < 50VDC 0,5VAC < < 40VAC 0,5VDC < < 50VDC 0,5VAC < < 40VAC 0,1mADC < < 200mADC 0,1mAAC < < 150mAAC 0,1mADC < < 200mADC 0,1mAAC < < 150mAAC Mounting EN50022 sym. DIN-rail 35mm EN50022 sym. DIN-rail 35mm Screw-type (tightening torque) Pozidrive No. 1 (0,6-0,8Nm) Philips M2,5 (0,6-0,8Nm) Slotted 4mm (0,6-0,8Nm) Weight 90g 170g Dimensions (B*H*T) 22,5*85*65mm 42*95*40mm

HIQEL GmbH Page 6 Typical accumulator charging graph Charging 0,020 0,015 Current [ma] 0,010 0,005 0,000 0 21.600 43.200 64.800 86.400 108.000 129.600 151.200 172.800 194.400 Time [min] Typical accumulator discharging graph Circuit diagram see Testing the accumulator. K1 = JW2SN-DC24V, Rspule= 1k065 Ohm (connect two relay coils serially), Rgesamt=2k3 Ohm. Discharging 30,000 25,000 Accumulatorvoltage [VDC] 20,000 15,000 10,000 5,000 0,000 0 200 400 600 800 1000 1200 1400 1600 Time [min] After the relays fall the accumulator voltage will rise. Accumulator capacity: (1300*60)/(2300*150)= 0,226mAh. In fact it is a little lower but these numbers are sufficient for testing.

HIQEL GmbH Page 7 Content PS24 APPLICATION INSTRCTION... 1 FNCTION... 1 DESCRIPTION... 1 Mounting... 1 Front panel with displays and control elements... 1 Wiring... 2 Accumulator (storage-battery)... 3 Testing the accumulator... 3... 3 Technical information... 5 CONTENT...7 Copyright 2003 HIQEL GmbH, Bairisch Kölldorf 266, A-8344 Bad Gleichenberg This manual is subject to copyright law. All rights are reserved. Great care has been taken in the creation of the text, illustrations and program examples in this manual. Neither HIQEL, their authors nor their interpreters may be held responsible for any errors herein, nor can they be held responsible or liable for consequences arising from any errors herein. This manual may not be copied in part or whole in any form including electronic media without the written consent of Hiquel. Neither may it be transferred in any other language suitable for machines or data processing facilities. Also rights for reproduction through lecture, radio or television transmission are reserved. This documentation and the accompanying software is copyrighted by Hiquel.