Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Similar documents
3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

Solenoid valve VDHT standard BSP (British Standard Pipe)

Solenoid valve VDHT standard BSP (British Standard Pipe)

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS

Nessie High-Pressure Pumps for technical water, type PAH

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

Assisted lift operated 2/2-way solenoid valves Type EV251B

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Nessie Water Mist Nozzles

Servo-operated 2/2-way solenoid valves Type EV220A

High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Assisted lift operated 2/2-way solenoid valves Type EV250B

2/2-way assisted lift operated solenoid valve type EV250B

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

PAHT pump PAHT X

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Reliable season change

APP pump instruction APP and APP 16-22

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Data sheet APP

APP pump instruction APP 21-43

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Servo-operated 2/2-way solenoid valves for high pressure

APP S 674 pumps APP S / APP S APP S

Solenoid valves 2/2-way servo operated type EV220B 15 50

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Energy Recovery Device isave 21-40

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Solenoid valve Types EV220B 15 - EV220B 50

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Danfoss Saginomiya 4 - Way Reversing Valves

Solenoid valve Types EV220B 15 - EV220B 50

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

Premounted Midi Shunts

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

Filter solutions for Danfoss PAH, APP and CLP pumps

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Valve bodies type RA-N with integrated presetting

Parallel coupled APP pumps

The precise step to take

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

Servooperated. 2/2-way solenoid valves EV220A. The Home of Control & Automation in Ireland

Control Card VLT FC Series

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

High Capacity Valve Body, Type RA-G

Reliable season change

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Technical Data Sheet

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

Automatic balancing valves ASV-PV DN (3rd gen.)

Advanced efficiency, precision cooling Design an HVAC system like no other

Oil pump type RSA. Catalogue 1. Burner Components

Advanced efficiency, precision cooling Design an HVAC system like no other

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

ATEX instruction APP S 674 pumps APP S , APP S and APP S

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

PAH / PAHT / PAHT G pumps

Advanced efficiency, precision cooling Design an HVAC system like no other

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

PVG 120 Proportional Valves. Service Parts Manual

Solenoid valves Type EVU for fluorinated refrigerants

Flow-compensated temperature controller AVTQ DN 15

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

Changing pistons APP and APP 16-22

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Solenoid valves Type EVU

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Pilot-Operated Directional Control Valves Series D3 - D11

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Specification. Bore No.

Solenoid valves for drinking water Types EV220BW and EV228BW

TMVW Orbital Motors. Technical Information

APP S pumps APP S / APP S / APP S 21-38

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

OML and OMM Orbital motors. Technical Information

The manifolds can be powered through various fieldbus systems, multipole or common terminals.

Transcription:

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge" Generally The Nessie 3/2 way valves have in particular been designed for applications in high-pressure humidification and adiabatic cooling systems. Each valve has an IN, OUT and DRAIN port. When the valve is not in operation the connection between IN and OUT is closed while the connection between OUT and DRAIN stays open. This allows to instantaneously relief the pressure at shut down from the application, typically a nozzle branch, to prevent the nozzles from dripping. If desired, the nozzle branch can be entirely drained after shut down to avoid bacterial growth. Furthermore, each valve has its individual properties to match exactly the specific needs in size and functionality. All Nessie valves are made of stainless steel (AISI 304) and are suitable for potable and technical water. They have an extremely long service life for at least one million operations and are even then very easy to service. Inline valves are available with European BSP thread (G-thread) and American National Pipe Thread (NPT). For the VDHT 15EC and VDH 30EC Danfoss offers a wide range of single and multiple manifolds. The enclosure rating is IP 67, including any standard solenoid coil. A large variety of coils for various supply voltages is available for all Nessie valves. 04-2006 DKCFN.PD.040.A2.02 521B0820 Nessie is a trademark of Danfoss A/S

Generally (continued) The VDM 2E is a very small and compact valve for minor flow rates up to 1.8 litres per minute (0.5 gpm). It is a direct operated type of valve with just one coil. It is suitable for systems with many zones with few nozzles and is a very cost effective solution. The VDHT 15E is a medium size single inline valve for flow rates up to 15 litres per minute (4 gpm). It is based on the latest Nessie valve technology, comprising a piston type NC valve and a NO pilot stage in one housing. It covers a very wide flow range already starting from 1 litre per minute (0.26 gpm) and is the ideal solution instead of using 2 separate valves (1 NC and 1 NO). The VDHT 15E requires 2 solenoids activated by a common signal (i.e. 24 V AC). The VDHT 15EC 3/2 is the Cetop 3 variant of the VDHT 15E, by means that connections are made through a valve block or multiple valve manifold. In multiple valve applications up to 5 valves can be installed on a common manifold side by side, saving time, space and plumbing effort. The VDH 30EC is a highly dedicated valve for demanding applications, i.e. with long pipe runs or very large flow rates up to 30 l/min (8 gpm). It consists of one NC and one NO pilot operated piston type valve in one housing. A very special feature of this valve is the so called Soft-Charge functionality; when operating the two solenoid coils with a time delay, the valve works as a flow divider, allowing to fill the application pipes at a reduced flow rate (less pressure). Therewith water hammering and pressure shocks at switch-on and shut-off can be eliminated. Furthermore, the valve is prepared for individual adjustment to a certain flow rate; by inserting an orifice in the OUT (B-) or DRAIN (T-)- port the flow diversion can be manipulated. 2 DKCFN.PD.040.A2.02 521B0820

HVAC Block The HVAC blocks are especially designed for induct applications where an additional flush valve installed on the block allows to flush the system for improved hygiene. 3 different types are available for 1, 2 or 3 VDHT 15EC or VDH 30EC plus one additional 2/2-way VDHT flush valve. The blocks comprise one common connection for the pressure line from the pump station and one common drain port for pressure relief and flushing. For each discharge an outlet port is available. The HVAC block is a very cost efficient solution i.e. in in-duct systems with 6-step valve control. Each VDH/VDHT valve is operated by two coils (NC and NO), while the flush valve is a single coil NC valve. Please also refer to the list of code numbers on page 5. Picture fully equipped blocks 1+1, 2+1 and 3+1 Sub-base valve manifolds Danfoss offers sub-base manifolds for installing 3, 4 or 5 VDH/VDHT 3/2 way valves side by side. Just as the HVAC blocks, the sub-base manifolds represent a very cost efficient solution, saving significantly on time, space and plumbing effort, as the number of connections is minimized. Picture sub-base manifolds and simple inline block Both multiple valve concepts are very service friendly as the valves can individually be detached from the manifold for service within a few minutes. VDHT 15EC valves can be service while installed on the block. The HVAC block and the multiple valve manifolds are interconnectable, i.e. in systems with more than 5 valves. Danfoss recommends bonded seal fittings for all connections. All manifolds can be connected from both sides, allowing a high level of flexibility for placing them i.e. directly on the pumping station. For a spare block position Danfoss offers a bind plate to cover the connections when not in use. DKCFN.PD.040.A2.02 521B0820 3

3/2-way principle Solenoid coil(s) de-energized Solenoid coils energized Soft-Charge principle Both coils de-energized NC coil energized only Both coils energized P-port (IN) closed, P-, T-and B-port P- and B-port (IN and B- and T-port connected (IN, OUT and DRAIN) OUT) connected, T-port (OUT and DRAIN), application connected; flow partially (DRAIN) closed, full flow pipe drained to application and drain to application Technical Data VDM 2E VDHT 15E VDHT 15 EC VDH 30 EC Max. continuous inlet pressure in bar/psi 80/1150 140/2000 140/2000 140/2000 Max. peak inlet pressure in bar/psi 100/1450 160/2300 160/2300 160/2300 Min. operation pressure at IN port in bar/psi 0 2/29 2/29 5/73 Drain opening pressure in bar/psi 80/1150 80/1150 80/1150 140/2000 Max. flow IN to OUT in l/min/gpm 1.8/0.5 15/4 15/4 30/8 Min. flow IN to OUT in l/min/gpm 0 1/0.26 1/0.26 2/0.53 Max. flow to DRAIN in l/min/gpm 0.3/0.08 5/1.3 5/1.3 30/8 Opening/closing time in ms 250 250 250 150 Max. water temperature in C/ F 50/122 50/122 50/122 50/122 Service life min 1 million operations Weight without coil(s) in kg/lbs 1.1/2.4 1.5/3.5 1.5/3.5 2.7/6 Pressure losses at different flows VDM 2E3/2 VDHT 15E3/2, VDHT 15 EC3/2 VDH 30EC3/2 4 DKCFN.PD.040.A2.02 521B0820

Code Numbers Valves and blocks VDM 2E G ¼ VDM 2E ¼ NPT VDHT 15E G 3 8, 3 8, ¼ VDHT 15E 3 3 8 NPT VDHT 15EC (Cetop 3) VDH 30EC (Cetop 3) Single in-line block G 3 8 for VDHT 15 EC or VDH 30EC Single in-line block 3 8 NPT for VDHT 15 EC or VDH 30EC HVAC block 1+1 (1 valve + flush valve) HVAC block 2+1 (2 valves + flush valve) HVAC block 3+1 (3 valves + flush valve) VDHT 30EC NC 2/2-way (flush valve) Sub-base manifold for 3 VDHT 15EC/VDH 30EC Sub-base manifold for 4 VDHT 15EC/VDH 30EC Sub-base manifold for 5 VDHT 15EC/VDH 30EC Blind plate (to cover spare position) Code number 180L3006 180L3007 180L0173 180L0174 180L0240 180L0051 180L0200 180L0201 180L0181 180L0182 180L0183 180L0096 180L0261 180L0262 180L0263 180L0079 Coils Supply Voltage Power Code number Standard clip-on coils NC+NO 24 V/50 Hz 220V/50 Hz 240V/50 Hz 24 V/60 Hz 110 V/50/60 Hz 220 V/60 Hz 240 V/60 Hz 018F7920 018F7921 018F7924 018F7922 018F7923 018F7925 018F7926 UL Recognized (UR) coils NC+NO 24 V/50/60 Hz 110 V/50/60 Hz 208-240 V 50/60 Hz 14 W 14 W 14 W 018F7907 018F7909 018F7908 Plug for UR coils with DIN spade all voltages 180Z0183 Service parts Service kit for VDM 2E Piston kit for VDHT 15E NC Piston kit for VDH 30EC NC+NO Code number 180Z0041 180Z0015 180L5005 Water Quality, Filtration All types of Nessie valves are suitable for operation with potable water or technical water such as reverse osmosis water, de-mineralised water or de-ionised water. The water must be filtered to a minimum of 10 μm absolute. Installation The VDM 2E and VDHT 15E can be mounted selfsupporting by the pipes or can be mounted with 2 bolts to any surface (see below). The VDHT 15EC and VDH 30EC are installed according to the Cetop standard. 4 bolts and O-rings for block mounting are supplied with the valve. DKCFN.PD.040.A2.02 521B0820 5

Dimensions, mm (in) VDM 2E3/2 VDHT 15E3/2 VDHT 15EC 6 DKCFN.PD.040.A2.02 521B0820

Dimensions, mm (in) VDH 30EC3/2 HVAC Blocks 1+1, 2+1 and 3+1 DKCFN.PD.040.A2.02 521B0820 7

Dimensions, mm (in) Manifolds Multiple blocks for 3, 4 and 5 valves VDHT/VDH Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 DKCFN.PD.040.A2.02 521B0820 Produced by Danfoss Industri Service - Advertising 06.02.BPV.E