your reliable partner ROBA-stop -M Electromagnetic safety brakes C US LR K.891.V16.EN

Similar documents
your reliable partner ROBA-stop -M K.891.V17.EN

your reliable partner ROBA-stop K.800.V09.EN

your reliable partner ROBA-stop -silenzio K.896.V16.EN

your reliable partner ROBA-stop -silenzio Stage and Elevator Brakes C US LR K.896.V14.EN

Installation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _.

ROBA -topstop. Brake systems for gravity loaded axes. ROBA-stop

your reliable partner Safety brakes IMG.803.V14.EN

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Installation and Operational Instructions for ROBA-stop -M Brake Type 891. _. _ Sizes 2 500

Installation and Operational Instructions for ROBA-stop -silenzio Type 896. _. Sizes

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and operational instructions for ROBA-stop -M Brake Type 891. _. _ Sizes 2 500

ROBA-stop -silenzio. Stage and Elevator Brakes

your reliable partner ROBA -topstop K.899.V14.EN

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

ROBATIC ROBA -quick ROBA -takt. Reliable coupling and braking.

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes

Please read these Operational Instructions carefully and follow them accordingly!

Installation and Operating Instructions for ROBA-stop -silenzio Type 896._3_. Sizes

ROBATIC, ROBA -quick ROBA -takt

Translation of the Original Operational Instructions B.8.8.EN. ROBA -topstop Type 899. _. Sizes

ROBA-stop -M Electromagnetic safety brakes

Motor mounted Brakes. Safety. Made in Germany.

Installation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes

Electromagnetic clutches and brakes INTORQ and INTORQ

Installation and Operational Instructions for ROBA -D Couplings Type 91_. _

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

COMBIBOX. Program Schedule. Design. COMBIBOX clutch-brake-combination type 10 / 09 / 06. Attachments

Installation and Operating Instructions for ROBA -takt Switch Gear Type

COMBIBOX Program Schedule. Design. COMBIBOX Clutch-brake-combination type 10 / 09 / 06. Attachments input

Torque Limiter with overload and load separation functions for

Installation and Operational Instructions for EAS -smartic synchronous clutch Type 48_. 5._ Sizes 01 2

The controllableollable Torque Limiting Clutch for

Electromagnetic clutch-brake combinations INTORQ

COMBIBOX. Program Schedule. with an energised to engage single sided clutch without brake... COMBIBOX 09

Installation and Operational Instructions for EAS -Compact overload clutch, Type 49_. 4._ Sizes 4 and 5

Please read these Operational Instructions carefully and follow them accordingly!

Installation and Operational Instructions for EAS -Compact overload clutch Type 49_. 4._ Sizes 01 to 3

D58 Series Brake Instructions

Standard with cone bushing. Backlash-free Safety Clutch

COMBISTOP NEW. Spring applied brakes

Armature Actuated Brakes RoHS Compliant- meets the requirements of the Restriction of Hazardous Substances Directive

ELECTROMAGNETIC DISC BRAKES H2SP SERIES WITH CONSTANT BRAKING TORQUE

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HT) Sizes

MADE IN GERMANY. Electromagnetic Technology

Ship & offshore. Safety.

Steering column and sensor

Electromagnetically actuated clutches and brakes

setting the standard BFK468 spring-applied brake The Performance Standard 100-2,400 Nm

KEB-sähkömagneettiset jarrut ja kytkimet

Brakes. KNOTT Electromagnetic Release Spring-Applied Dual-Surface Fail-Safe Brakes TYPE ERA, ERB, ERC ELECTROMAGNETIC

Flexible Couplings N-BIPEX Series

Installation and Operational Instructions for EAS -Compact -R, EAS -Compact -RA rustproof synchronous clutch Type 49A. 5.

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

! CAUTION! Damages on the machine possible.

Chapter 2: Directional Control Valves

Installation and Operating Instructions for ROBA -ES couplings Type 940. _. _ Sizes 14-48

Brakes ELECTROMAGNETIC. KNOTT Electromagnetic Single Disc Brakes TYPE EAA, EAR

Hydraulic Caliper Disc Brakes SFRA 5

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Electromagnetic tooth clutch Type 546

BRAKE MOTORS. 1. Brake motors TECHNICAL CATALOGUE. M Series / Standard / IEC

Technical Documentation

Lenze spring applied brakes

Installation and Operational Instructions for ROBA -ES Couplings Type 940. _. _ Sizes 14 65

MAGNETTECHNIQUE. More than 30 years experience in the field of Electromagnetic technology. KEB Germany. KEB China. KEB America.

Essential equipment for all your requirements

Datasheet. Pitch Motor PMSM SP190C8

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Datasheet. Pitch Motor PMSM SP190F8

POWER TRANSMISSION. Product range

Lenze. Drives with worm gearboxes 52.

Directional Control Valve Series D1VW

6 Project Planning for Components on the Input Side

3-phase stepping motors

Stromag Dessau. safety in motion PRODUCT CATALOGUE. NFF4F-LS Brake. for Slow-Running High Torque Drivelines, in harsh environment

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Service Instructions BZFM V7

FACTORY OF ELECTRIC APPARATUS EMA ELFA

Micro Contactor MA Series

Electronic Ballast EVG 2000-T

3TM Vacuum Contactors

Plug-in relays Mini ISO relays

FLENDER Standard Couplings

Datasheet. Pitch Motor PMSM SP260B8

5-Phase Stepper Motor

Selection Tool. on the Internet at in the section MÄDLER -Tools. Other sizes and designs on request. Connecting Shafts Page 766

Accessories smart additions for efficiency and intelligent performance

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electromagnetic single-face clutch. Operating Instructions E00 ACTIVE CLUTCH LINE

Locking Assemblies & Locking Elements

DEVICE STATE/BYPASSED FAILURE OVERLOAD

GEARLESS Z6 - Z20 A.C.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

HIGH POWER SOLENOID DRIVER 1

Energy Supply Systems

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Transcription:

ROBA-stop -M Electromagnetic safety brakes C US LR 0897 K.89.V6.EN www..com

Your Reliable Brake Easy installation Class of insulation F; 00 % duty cycle C US Short switching times Different torque variants due to variable equipment Completely enclosed design IP4 / IP6 Minimum torsional backlash due to accurate toothing Long service lifetime Low wear Advantages for Your Applications Simple installation Brake outer diameter completely enclosed (higher protection can easily be realised) Magnetic coil is designed for a relative duty cycle of 00 % Magnetic coil and casting compound correspond to class of insulation F The nominal air gap is specified by design and inspected Short switching times Maintenance-free over the entire service lifetime of the rotor Certain ROBA-stop -M brakes can be used for safety-relevant applications acc. ISO 3849- (for Permitted Types, see page 6). For information on the safety parameters, please contact mayr power transmission. Function ROBA-stop -M brakes are spring applied, electromagnetic safety brakes. Spring applied function: In de-energised condition, helical springs (6) press against the armature disk (). The rotor (3) is held between the armature disk () and the corresponding mounting surface of the machine. The shaft is braked via the toothed hub (). Electromagnetic: When the power is switched on, a magnetic field is built up. The armature disk () is attracted to the coil carrier () against the spring pressure. The brake is released and the shaft is able to rotate freely. Safety brakes: The brake brakes reliably and safely in the event of a power switchoff, a power failure or an EMERGENCY STOP. 3 6

ROBA-stop -M Page 4 s to 000 Braking torques 0.7 to 400 Nm (Standard design) 4 to 600 Nm (Holding brake) Permitted shaft diameter Ø 8 to 90 Type 89..0 Type 89..0 Type 89. 4. Type 89. 4. Standard design Page Standard design with friction disk IP6 design with flange plate Tacho attachment design with flange plate Short Description Installation Page 6 Brake Dimensioning, Friction-Power Diagrams Page 8 Further Options Page 0 Switching Times, Electrical Connection, Electrical Accessories Page Guidelines on safety-critical applications (acc. ISO 3849-) Page 6 Guidelines Page 7 Order Number Nominal torque holding brake 0 0 Without additional parts Hand release ) Friction disk 7) 00 % Nominal torque standard 84 % Nominal torque 6) 68 % Nominal torque 6) 3 3 0 % Nominal torque 6) 4 4 34 % Nominal torque 6) Nominal torque adjustable ) 6) 6 % Nominal torque 6) 7 % Nominal torque 6) 8 ) 7) Hand release/friction disk Flange plate 8) ) 8) Hand release/flange plate / 8 9.. / / / s to 000 Standard brake metal rotor 3) Holding brake metal rotor Standard brake Friction lining rotor 4) 0 Standard ) Enclosed design IP6 ) Tacho design ) Central torque adjustment ) 0 3 Coil voltage 9) [VDC] 4 0) 04 80 07 Bore Hub Ø d (please observe dimensions pages 4-, Table, page 7) Keyway acc. DIN 688/ or DIN 688/3 Example: 6 / 89..0 / 4 / 6 / 688/ For Further Options, see page 0. ) Hand release not installed on size size 00. 000: Hand release only available as emergency hand release. Hand release for IP6 design only ex works. ) On request 3) From size 60 4) Up to size 3 (for brake operation in hoisting device drives, please contact the manufacturer) ) Not in combination with friction disk 6) See Technical Explanations pages 6 7 7) s 60 8) Standard tacho brake flange plate 9) Brake operation only possible with overexcitation on size 00 from 700 Nm onwards and on size 000. 0) Not possible on size 000. ) Standard and tacho design are identical on size 000. Order number for standard (tacho design) on size 000: 000 / 89. _. / _ / _ / _ ROBA-stop -M safety brakes are also available in ATEX design according to the directive 94/9 EC (ATEX 9). (Please contact the manufacturer separately for this). On request ROBA-stop safety brakes can also be delivered with UL approval. E8978 3

ROBA-stop -M electromagnetic safety brakes Type 89..0 F Ø f 90 (3x0 ) s K H L +0, a -0,0 Air gap (+ 0. on size 00) (+ 0,/- 0,0 for 000) F x 0 (x80 ) Ø D h9 Ø M Ø R Ø r Ø d H7 l Ø G 4 Cable approx. 400 mm long for sizes 60, for sizes 00 00 approx. 600 mm long for size 000 approx. 000 mm long c Technical Data Braking Torque 4 8 6 3 60 00 0 0 00 000 Standard brake ) Type 89.0._ M N [Nm] 4 8 6 3 60 00 0 0 Type 89.._ 9) Holding brake.) Type 89.._ M N [Nm] 4 8 6 3 64 00 80 0 40.).) 4) 00 000 4) 4) 800 600 Electrical power P N [W] 9 9 38 46 69 88 98 0 60 Maximum speed n max [rpm] 6000 000 4000 300 3000 3000 3000 00 00 00 00 Weight Standard brake Type 89.0._ m [kg] 0.76..8 3.4 4. 7.4 3.6 9. 33.3 38 79 Type 89.._ 9) Holding brake Type 89.._ m [kg] 0.76..8 3.4 4. 7.4 3.6 9. 33.3 38 79 4 Bores H7 ) Bore Ø d Standard brake Type 89.0._ Type 89.._ 9) Holding brake Type 89.._ 4 8 6 3 60 00 0 0 00 000 min. [mm] 8 0 4 9 4 30 40.) 0.) 7 max. [mm] 0 30 3 4 0 60 80 90 Please observe Table, page 7 min. [mm] 8 0 4 9 4 30 40 0 7 max. [mm] 0 30 3 4 0 7 90 Please observe Table, page 7 Dimensions [mm] 4 8 6 3 60 00 0 0 00 000 a 0. 0. 0. 0. 0. 0. 0.3 0.3 0.3 0.4 0. b 30 30 36 4 60 78 84 96 30 80 b 30 30 36 4 6 - - - - - c 4 6. 8.7 3. 39. 0. 4 9 69 70 8 c 7. 9.7 36.8 40..8 - - - - - c 9 3. 34.7 4. 47. 8. 64 7 83 89 06 D 76 87 03 8 48 68 00 8 30 38 D 8 9 08 30 48 68 00 8 30 38 D 8 9 08 34 4 74 06 7 66 38 39 F 48. 4 63. 77 88 00. 3 33 3 79 - F 0. 08 7. 3 69 8. 67 347 494 - f 8 8 8 8 0 4 4 9 3 3 -

ROBA-stop -M electromagnetic safety brakes Type 89..0 Standard with friction disk K h L 3 L K Type 89. 4. Enclosed design (IP 6) with flange plate L 4 L h Type 89. 4. Tacho attachment design with flange plate L L K 3 h Ø D h9 * Ø b Ø s Ø D h9 * Ø b Ø G H8 Ø D Ø D g7 Ø b t z H7 Ø G Ø M Ø Z c c g c * Outer diameter friction disk: free size; outer diameter flange plate: -0. Missing dimensions are identical with Type 89.0.0 see page 4. Dimensions [mm] 4 8 6 3 60 00 0 0 00 000 G 6. 8 33 36 38 48 6 8 00 G 3. 8. 3. 40.. 60 7. 8. 9 3 00 G H8 - - 8 3 4 48 6 00 g 4 4 4 4 4 4 6 7 7 7 H 6 4. 7. 6 7 6 34 4 46 4. - h... - - - - - h 6 6 7 8 8 0 4 9 K 0 0.8..3 8.3 0 0 8. K 9 9.8.. 7. 0.8 - - - - - K 0 8.8. 0.3 0.3 4 8.. 7. K 3 0 9.8. 0.3 0.3 4 8 6 3 9 L 39 4. 4..7 6.7 7. 84 97 6 4 ) 6) 3 L 38 40. 44. 4.7 60.7 7. 83 96 3 3 6) L 3 40 4. 46. 7 63 73.8 - - - - - L 4 44 47.. 6.7 69.7 80. 94 09 30 33 70 ) L 43 46. 0. 6.7 68.7 79. 93 08 9 3 6 6) l 8 8 0 0 30 30 3 40 0 3) 70 supporting length of the key M 66 7 90 3 4 70 96 30 78 3 M 9 3 4 6 7 88 00 4. R 7 6 8 0 30. 4 78 06 3 300 r 4 4 3 70 83 94 06 40 6 90 s M4 M4 M M6 M6 M8 M8 M8 8) M0 8) 6 x M0 6 x M 7) s M3 M4 M4 M4 M M M M6 M6 6 x M8 6 x M6 t 6 0 0 0 0 0 0 0 0 3 x 0 0 0 0-0. 0-0. 0-0 - 3 0-3 0-3 3-4 0. Z 36 4 6 7 90 00 30 7 - z - Standard voltages 4; 04; 80; 07 V. Permitted voltage tolerance acc. DIN IEC 60038 (±0 %). ) Braking torque tolerance on size 0 = +30 %/-0 %, for other adjustments see Table 3, page 7 and type key page 3..) Braking torque tolerance = +40 %/-0 % (friction lining pairing conditioning necessary, see Operational Instructions B.8.._)..) Minimum bore not permitted for braking torque adjustment = %. ) The respective maximum bores are to be seen in relation to the corresponding keyways and their tolerances acc. Table page 7. 3) Hub facing side (both sides) 3 mm deep, Ø 97 recessed. We reserve the right to make dimensional and constructional alterations. 4) Brake operation only possible with overexcitation ) The IP6 design is equipped with a sealing cover on size 000: L = 49 mm, L 4 = 70 mm. 6) Projection screw plugs (emergency hand release): 8. mm 7) For flange plate securement: additional x M screws 8) For flange plate securement: additional M8/M0 screws 9) Only up to 3

ROBA-stop -M Short Description Installation Installation Conditions The eccentricity of the shaft end in relation to the mounting pitch circle must not exceed 0. mm. The positional tolerance of the threaded holes for the cap screws (Item 8, Fig. ) must not exceed 0. mm. The axial run-out deviation of the screw-on surface to the shaft must not exceed the permitted axial run-out tolerance acc. DIN 49 N. Larger deviations can lead to a drop in torque, to continuous grinding of the rotor and to overheating. 0 Fig. Installation 3 Inspection dimension x 4 7 3 9 Fig. F α. Mount the hub () onto the shaft and secure it axially (e.g. using a locking ring). Recommended tolerance of hub-shaft connection H7/k6. Avoid too tight hub-shaft connections (particularly on max. bores). Keep the friction surfaces free of oil and grease. Attention! Please observe supporting length of the key acc. Dimensions on page.. If necessary (dependent on Type), move the friction disk or the flange plate over the shaft and attach it to the machine wall (or screw on for size 000). If there are no suitable counter-friction surfaces made of grey cast or steel available, please use brake Types 89. /3._ (with friction disk (9)) or 89..4/._ (with flange plate). When using a brake with a friction disk (Type 89. /3._), please observe the stamp friction side on the friction disk. 3. Push the rotor (3) onto the hub () by hand. 4. If necessary, install the hand release (only on sizes - 00/the emergency hand release is partly assembled on size 000).. If necessary (dependent on Type, Type 89. _.), insert the O-ring into the axial recess of the coil carrier (). 6. Push the rest of the brake over the hub () and the rotor collar (3). 7. Attach the brake onto the motor bearing shield or onto the machine wall evenly all around using the cap screws (8) - please observe the seal dependent on the type - with a torque wrench and tightening torque (acc. Table, page 7). Attention! Only use mayr original screws (Table, page 7). 8 7 6 Braking Torque Adjustment Different torque adjustments can be made using different spring configurations (6) in the coil carrier () (see Table 3, page 7). Hand Release Installation (s 00) On Type 89. _. installation of the hand release is only possible if a request for a hand release is stated on the brake order form (completely enclosed coil carrier ()). For hand release installation, the brake must be dismantled and de-energised. Installation Procedure (Figs. and ):. Unscrew brake from the motor bearing shield or from the machine wall.. Remove the sealing plugs from the hand release bores in the coil carrier (). 3. Put the thrust springs (0) onto the threaded bolts (). The threaded bolts () come manufacturer-side assembled with a key as tension element and secured with adhesive up to M60. This connection must not be loosened. 4. Push the threaded bolts () with thrust springs (0) from the inside (you should be facing the magnetic coil (7)) into the hand release bores in the coil carrier ().. Push the O-rings (only with sealed hand release, Type 89. _.) over the threaded bolts () and insert them into the recesses of the coil carrier (). 6. Push intermediate plates (only with sealed hand release, Type 89. _.) over the threaded bolts (). 7. Mount the switch bracket (), add the washers (3) and lightly screw on the self-locking hexagon nuts (4). 8. Tighten both hexagon nuts (4) until the armature disk () lies evenly against the coil carrier (). 9. Loosen both hexagon nuts (4) by Y turns (see Table, page 7), thereby creating an air gap between the armature disk () and the coil carrier () or the inspection dimension x (see Page 7, Table ). Attention! An uneven adjustment dimension on the hand release can cause the brake to malfunction. 0. After installing the release cover, screw the hand release rod () into the switch bracket () and tighten it. The hand release rod () must be protected against loosening using a screw-securing product, e.g. Loctite 43. Maintenance ROBA-stop -M brakes are mainly maintenance-free. However, the rotor (3) is subject to operational wear. The friction linings are robust and wear-resistant. This ensures a particularly long service lifetime. If the rotor (3) does become worn due to the high total friction work, and the function of the brake can no longer be guaranteed, the brake can be re-set to its functional state by replacing the rotor. For this, the brake must be cleaned thoroughly. The wear condition of the rotor (3) is determined by measuring the release voltage (this must not exceed max. 90 % of the nominal voltage on a warm brake), or by measuring the rotor thickness on a dismantled brake ( minimum rotor thickness acc. Table in the currently valid Installation and Operational Instructions). On sizes 00 and 000 there is an air gap inspection opening. This means that the brake does not have to be dismantled. Attention! The brake function cannot be guaranteed on brakes with a reduced braking torque and/or operation with a fast-acting rectifier if the friction linings are heavily worn. Unpermittedly high wear relaxes the thrust springs (6), leading to a drop in torque. 6

ROBA-stop -M Short Description Installation Technical Data Installation 4 8 6 3 60 00 0 0 00 000 Inspection dimension x [mm] 0.9 +0. 0.9 +0.. +0..6 +0..8 +0.. +0.. +0.. +0..4 +0..4 +0. - Number of rotations Y [-].7.7..0.0.0.6.6.. - Release force Standard brake Type 89.0._ Type 89.._ Holding brake Type 89.0 _._ F [N] 0 3 70 00 30 0 60 90 30 30 - F [N] 6 4 90 70 300 340 30 430 470 - Release angle a [ ] 6 7 7 7 8 0 3 0 0 - Fixing screws (8) (Item 8, Fig., Page 6) Type 89. 0._ Type 89. 4._ [-] M4 x 4 M4 x 4 M x 0 M6 x 60 M6 x 60 M8 x 7 DIN 69 69 69 69 69 69 [-] DIN M4 x 0 476 M4 x 0 476 M x M6 x 6 69 69 M6 x 70 476 M8 x 8 476 M8 x 80 476 M8 x 90 476 M8 x 00 476 M8 x 0 476 M0 x 0 476 M0 x 30 476 6 x M0 x 0 476 6 x M0 x 30 476 6 x M x 30 476 6 x M x 0 476 Tightening torque T A [Nm]...0 9.0 9.0 4 4 83 Rotor thickness new condition [mm] 6.0 6.0 6.9 8 0.4. 4. 7 8. 8. Table Permitted Hub Bores Ø d max 4 8 6 3 60 00 0 0 00 000 Type 89.0._ Type 89.._ Type 89.._ Keyway JS9 Keyway P9 Keyway JS9 Keyway P9 688/ [mm] 3 3 8 30 3 4 4 7 90 688/3 [mm] 0-3 4 0 60 80-688/ [mm] 3 3 8 0 8 3 4 4 0 7 90 688/3 [mm] 0 30-4 0 80-688/ [mm] 3 3 8 30 3 4 4 7 90 688/3 [mm] 0-3 4 0 - - - 688/ [mm] 3 3 8 0 8 3 4 4 0 7 90 688/3 [mm] 0 30-4 0 - - Table Braking Torque Adjustments 4 8 6 3 60 00 0 0 00 000 ) Holding brake [Nm] 4 8 6 3 64 00 80 0 40 800 ) 600 Standard brake Table 3 Braking torque ) in % % [Nm]. 0 0 40 7 8 30 700 ) 400 % [Nm]. 4. 9 8 36 68 0 6 80 600 00 00 % [Nm] 4 8 6 3 60 00 0 0 00 000 84 % [Nm].7 3.4 6.8 3. 7 0 8 400 800 68 % [Nm].4.8. 4 70 00 80 30 700 0 % [Nm] 4 8 6 30 0 7 0 00 34 % [Nm] 0.7.4.8. - - - 00 400 ) Brake operation only possible with overexcitation. ) The braking torque (switching torque) is the torque effective in the shaft train of a slipping brake with a sliding speed of m/s in relation to the mean friction radius (acc. VDE 080/07.000). 7

ROBA-stop -M Brake Dimensioning Brake Selection. Brake selection Names: M erf. = t v = 90 x P J [kgm²] Mass moment of inertia x K M [Nm] n K [-] Safety factor (. according to conditions) J x n [sec] 9. x M M v erf. [Nm] Required braking torque M v = M N + (-)* M L [Nm] M L [Nm] Load torque * sign in brackets (-) is valid if load is braked during downward movement. Inspection of thermic load M N [Nm] Nominal torque (Technical Data page 4) Please observe the braking torque tolerance! J x n² M Q r = x [J/ braking] 8.4 M v n [rpm] Speed P [kw] Input power The permitted friction work (switching work) Q r zul. per braking for the specified switching frequency can be taken from the frictionpower diagrams (page 9). If the friction work (switching work) per braking is known, the max. switching frequency can also be taken from the Friction-Power Diagrams (page 9). t v [s] Braking action t [s] Connection time (Table 6 page ) Q r [J] Friction work present per braking Q r 0. [J] Friction work per 0. mm wear (Table 4) Q r ges. [J] Friction work up to rotor replacement (Table 4) Q r zul. [J] Permitted friction work (switching work) per braking action Due to operating parameters such as sliding speed, pressing or temperature the wear values can only be considered guideline values. When using a brake with a friction disk (Type 89.._), the max. friction work and friction power must be reduced by 30 % for s to 6 and by 0 % for s 3 60. The wear values Q r 0. and Q r ges. are therefore not valid. Friction Work per 0. mm wear up to rotor replacement Standard brake Type 89.0._ Type 89.._ Holding brake Type 89.._ Standard brake Type 89.0._ Type 89.._ Holding brake Type 89.._ 4 8 6 3 60 00 0 0 00 000 Q r 0. [0 6 J] 3 40 6 00 30 30 40 0 60 70 80 Q r 0. [0 6 J] 7 8 3 0 30 6 70 7 80 8 90 Q r ges. [0 6 J] 9 00 6 00 600 700 840 90 000 700 000 Q r ges. [0 6 J] 7 8 3 0 4 30 70 300 30 4 40 Table 4 Mass Moment of Inertia Rotor + hub with d max 4 8 6 3 60 00 0 0 00 000 Type 89.0._ (Metal rotor) Type 89.._ (Metal rotor) Type 89.._ (Friction lining rotor) J R+H [0-4 kgm²] 0. 0. 0.67.74 4.48 6.74 6.4 3.68 6.8.6 44 J R+H [0-4 kgm²] 0. 0.7 0.8.3 4. - - - - - - 8 Table

ROBA-stop -M Friction-Power Diagrams Type 89.0_._ and Type 89._._ (Standard brake) for 0 % of the maximum speed n max Permitted switching work per braking Q r zul. [J] 000 000 00 000 0 000 000 00 0 0 00 000 000 00 0 0 00 s 60 3 6 8 s 4 Diagram Switching frequency [/h] Type 89.0_._ and Type 89._._ (Standard brake) for the maximum speed n max Diagram Permitted switching work per braking Q r zul. [J] 000 000 00 000 0 000 000 00 0 0 00 000 Switching frequency [/h] 000 00 0 0 00 s 60 3 6 8 s 4 Type 89.0_._ (Haltebremse) bei 0 % der Maximaldrehzahl n max Type 89.0_._ (Haltebremse) bei Maximaldrehzahl n max 000 000 00 000 zulässige Schaltarbeit je Bremsung Q r zul. [J] Größe 000 00 000 Größe 00 Größe 0 0 000 Größe 0 0 000 Größe 00 Größe 60 000 000 Größe 3 Größe 6 Größe 8 00 00 Größe 4 Größe 0 0 0 0 0 0 Schalthäufigkeit [h - ] Schalthäufigkeit [h - ] Diagramm 3 Diagramm 4 zulässige Schaltarbeit je Bremsung Q r zul. [J] 9

ROBA-stop -M Further Options your reliable partner In addition to the standard brakes, mayr power transmission provides a multitude of further designs, which cannot be described in detail in this catalogue. Some of the most frequently requested options are: Microswitch / proximity switch for switching condition indication (release monitoring), Fig. Microswitch for wear indication (wear monitoring), Fig. Customer-specific flange plate, Fig. 3 IP6 design for continuous shafts, Fig. 4 Noise damping (O-ring damping between the gear hub and the rotor), Fig. ACH = Anti-Condensation heating, Fig. 6 Lockable hand release Please contact mayr power transmission for further information Double rotor design, Fig. 8 CCV-design, Fig. 9 ATEX design Special friction material Backlash-free design Special coil voltages Release monitoring When the magnetic coil in the coil carrier () is energised, the armature disk (3) is pulled towards the coil carrier (). The microswitch / proximity switch () emits a signal and the brake is released. 3 Air gap a Continuous shaft with IP6 The enclosed design (IP6) is equipped with a screw plug (sizes 8 to 00) or with a sealing cover (size 000) (see Type 89._4., page ) as part of the standard delivery. A radial shaft sealing ring () is installed in the coil carrier () on continuous shafts. Fig. Fig. 4 Wear monitoring Due to wear on the rotor (), the nominal air gap a between the coil carrier () and the armature disk (3) increases. If the limit air gap (see table in the Installation and Operational Instructions) is reached, the microswitch contact () switches over and emits a signal. The rotor () must be replaced. 3 Air gap a Damping rotor / toothed hub If vibrations in the drive line cannot be avoided, an O-ring () is used to damp backlash between the toothed hub (6) and the rotor (). Fig. Fig. 6 Special flange plate We offer a range of flange plates for customer-specific solutions, such as for example the special flange plate shown in Fig. 7 () with customertailored centering (8) and sealing (7). 7 8 Anti-condensation heating The anti-condensation heating () is used to prevent condensation formation inside the brake. Its usage is especially recommended at temperatures below 0 C or in high air humidity. Fig. 3 Fig. 6 0

ROBA-stop -M Further Options your reliable partner Lockable hand release In de-energised condition, the brake with lockable hand release can be released manually. By deflecting the hand release rod (), the armature disk (3) is pushed against the thrust springs (4) onto the coil carrier () and the braking torque is removed, Figs. 7a and 7b. 3 4 Fig. 7a 3 Fig. 7b Coil Hand release in starting position Hand release in engagement position Hand release in starting position Hand release in engagement position de-energised Shaft braked Shaft runs free Shaft braked Shaft runs free energised Shaft runs free Shaft runs free Shaft runs free Shaft runs free Double rotor design Double rotor design for increased torque at small outside diameter. CCV-design Cold Climate safety brake Type 89.4._ s 6-0 GL-certified up to -40 C. For further information please see brochure: ROBA-stop -M CCV P.89400.V Fig. 8 Fig. 9

ROBA-stop -M Switching Times Switching Times your reliable partner The values stated in the table are mean values which refer to the nominal air gap and the nominal torque on a warm brake. Switching times ) 4 8 6 3 60 00 0 0 00 000 Nominal torque (00 %) M [Nm] 4 8 6 3 60 00 0 0 00 000 Connection time DC-side switching t [ms] 0 8 0 30 0 68 80 00 00 80 AC-side switching t [ms] 00 60 0 30 400 00 640 730 00 00 00 Response delay DC-side switching t [ms] 6 6 3 3 38 40 0 30 70 on connection AC-side switching t [ms] 80 30 7 40 300 30 400 40 700 700 70 Separation ) t [ms] 33 36 4 84 0 80 6 64 348 480 336 3) Nominal torque (84 %) M [Nm].7 3.4 6.8 3. 7 8 400 840 Connection time DC-side switching t [ms] 6 9 3 48 80 88 09 8 60 60 88 AC-side switching t [ms] 60 6 3 640 800 04 68 760 760 90 Response delay DC-side switching t [ms] 9.6 9 6 40 6 6 6 64 80 48 on connection AC-side switching t [ms] 8 08 80 384 480 60 640 70 0 0 00 Separation time t [ms] 4 6 39 6 87 30 7 9 348 3 3) Nominal torque (68 %) M [Nm].4.8. 4 70 00 80 30 680 Connection time DC-side switching t [ms] 40 44 66 0 0 76 0 0 396 AC-side switching t [ms] 0 3 484 704 880 00 408 606 40 40 640 Response delay DC-side switching t [ms] 3 6 3 77 77 84 88 0 66 4 on connection AC-side switching t [ms] 76 86 38 8 660 770 880 990 40 40 60 Separation time t [ms] 3 34 3 7 3 3 6 8 300 03 3) Table 6 ) Standard brakes with a braking torque adjustment of 34% and 0 % have substantially longer connection times t and must not be used for switching time-relevant applications. ) The separation time t of holding brakes is.4 times longer than the separation time of standard brakes (00 %). 3) Value for operation with overexcitation M Names: M Br M L t 0, x M Br t M Br M L t t t U N = Braking torque = Load torque = Connection time = Response delay on connection = Separation time = Coil nominal voltage t t U N U t Diagram : Switching times for brake operation with coil nominal voltage

ROBA-stop -M Electrical Connection Electrical Connection and Wiring DC current is necessary for operation of the brake. The coil voltage is indicated on the Type tag as well as on the brake body and is designed according to the DIN IEC 60038 (±0 % tolerance). Operation can take place with alternating voltage using a mayr -DC voltage module or another suitable DC power supply. The connection possibilities can vary dependent on the brake equipment. Please follow the exact connections according to the Wiring Diagram. The manufacturer and the user must observe the applicable regulations and standards (e.g. DIN EN 6004- and DIN VDE 080). Their observance must be guaranteed and doublechecked! Earthing Connection The brake is designed for Protection Class I. This protection covers not only the basic insulation, but also the connection of all conductive parts to the protective conductor (PE) on the fixed installation. If the basic insulation fails, no contact voltage will remain. Please carry out a standardised inspection of the protective conductor connections to all contactable metal parts! Device Fuses To protect against damage from short circuits, please add suitable device fuses to the mains cable. Switching Behaviour The reliable operational behaviour of a brake is to a large extent dependent on the switching mode used. Furthermore, the switching times are influenced by the braking torque adjustment, temperature and the air gap between the armature disk and the coil carrier (dependent on the wear condition of the linings). I N I Current path Diagram 6 t M N * Overexcitation time t O Increased wear, and therefore an increasing air gap as well as coil heating lengthen the separation times t for the brake. For this reason, at least double the separation time t at nominal voltage must be selected as overexcitation time t O on each brake size The spring forces also influence the brake separation times t : Higher spring forces increase the separation times t and lower spring forces reduce the separation times t. M Braking torque path Operation with overexcitation requires an inspection of : - the required overexcitation time * - as well as the RMS coil capacity ** with a cycle frequency higher than cycle per minute (see page 4). t Magnetic Field Build-up When the voltage is switched on, a magnetic field is built up in the brake coil, which attracts the armature disk to the coil carrier and releases the brake. Field Build-up with Normal Excitation If the magnetic coil is energised with nominal voltage, the coil current does not immediately reach its nominal value. The coil inductivity causes the current to increase slowly as an exponential function. Accordingly, the build-up of the magnetic field takes place more slowly and the braking torque drop (curve, diagram 6) is also delayed. Field Build-up with Overexcitation A quicker drop in braking torque is achieved if the coil is temporarily placed under a higher voltage than the nominal voltage, as the current then increases more quickly. Once the brake is released, it needs to be switched over to the nominal voltage (curve, diagram 6). The relationship between overexcitation and separation time t is roughly indirectly proportional. This means that, using overexcitation voltage U O (= doubled nominal voltage U N ), the separation time t for release of the brake is halved. The ROBA -switch fast acting rectifier works on this principle. 3

** Coil capacity P P P N The coil capacity P must not be larger than P N. Otherwise the coil may fail due to thermic overload. Calculations: P [W] RMS coil capacity dependent on switching frequency, overexcitation, reduction in capacity and duty cycle P O x t O + P H x t H P = T P N [W] Coil nominal capacity (catalogue values, Type tag) P O [W] Coil capacity on overexcitation P O = ( U O U N )² x P N P H [W] Coil capacity at reduced capacity U H P H = ( U N )² x P N t O [s] Overexcitation time t H [s] Time of operation with reduction in capacity t off [s] Time without voltage t on [s] Time of operation (t O + t H ) T [s] Total time (t O + t H + t off ) U O [V] Overexcitation voltage (bridge voltage) U H [V] Holding voltage (half-wave voltage) U N [V] Coil nominal voltage Magnetic Field Removal AC-side Switching 3 4 6 7 8 N S F R ROBA -switch 0/07.000. U = 0,4 U~ 00-00V~ t: 0,0-sec 00-300V~ R: 0-0M 3 4 6 7 8 L IN R ROBA -switch 0/07.000. U = 0,4 U~ 00-00V~ t: 0,0-sec 00-300V~ R: 0-0M IN S DC S DC OUT 3 4 6 7 8 3 4 6 7 8 I max =,8A OUT DC-side Switching + Coil F: external fuse I max =,8A + R R The power circuit is interrupted in front of the mayr -DC voltage module. The magnetic field slowly reduces. This delays the rise in braking torque. When switching times are not important, please switch AC-side, as no protective measures are necessary for the coil and the switching contacts. AC-side switching means low-noise switching; however, the brake engagement time is longer (approx. 6 0 times longer than with DC-side switch-off), use for non-critical braking times. The power circuit is interrupted between the mayr -DC voltage module and the coil as well as mains-side. The magnetic field reduces extremely quickly. This causes a quick rise in braking torque. Time Diagram: t O t on t H T t off S F N L Coil F: external fuse When switching DC-side, high voltage peaks are produced in the coil, which can lead to wear on the contacts from sparks and to destruction of the insulation. U O DC-side switching means short brake engagement times (e.g. for EMERGENCY STOP operation); however, louder switching noises. U N U H 0 Diagram 7 For brakes, which do not require overexcitation, the holding voltage U H may be lower than the nominal voltage U N, e.g. on power reduction to reduce the coil temperature. Protection Circuit When using DC-side switching, the coil must be protected by a suitable protection circuit according to VDE 080, which is integrated in mayr -DC voltage module. To protect the switching contact from consumption when using DC-side switching, additional protective measures may be necessary (e.g. series connection of switching contacts). The switching contacts used should have a minimum contact opening of 3 mm and should be suitable for inductive load switching. Please make sure on selection that the rated voltage and the rated operating current are sufficient. Depending on the application, the switching contact can also be protected by other protection circuits (e.g. mayr -spark quenching unit), although this may of course then alter the switching times. 4

overexcitation (short separation time) and / or power reduction (reduction in coil capacity and temperature) no overexcitation and no power reduction fixed output voltage variable output voltage integrated DC-side disconnection without DC-side disconnection Type 09._00. Protection circuit Type 070.000.6 Type 08.00. Type 08.00. Type 08.000. Type 07.0. Type 07._00. Type 0.000.6 Type 04.000.6 ROBA - multiswitch ROBA -brakechecker Spark Quenching Unit Page 3 Safe Brake Control Type 0.00. ROBA -switch 4V ROBA -switch 4V ROBA -switch ROBA -switch Bridge Rectifier Half-wave Rectifier Reductions in switch-off voltage and wear on contacts ROBA -SBCplus Page 4 Controls and monitors up to two ROBA-stop safety brakes, especially in applications, which have to fulfill requirements regarding person protection according to the standards for functional reliability, such as for example ISO 3849 and IEC 606 Patent pending Electrical Accessories Functions of the DC Voltage Modules Page 6 Page 6 Page 7 Page 8 Page 9 Page 0 Page Page Application Allows short separation time Allows short separation time Allows short separation time Allows short separation time Standard application, preferred for noise-damped brakes Standard application + consistently controlled output voltage with variable input voltage + short connection time + short connection time + integrated release and drop-out recognition for permitted brakes For input voltages 4 VDC / 48 VDC For input voltage 4 VDC max. output current 0 A / A max. output current A max. output current. A no wear on contacts no wear on contacts Compact design Compact design For detailed information on our DC voltage modules, please go to: www.mayr.com

Half-wave and bridge rectifiers Type 0_.000.6 Application your reliable partner Rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA-quick, ROBATIC ), electromagnets, electrovalves, contactors, switch-on safe DC motors, etc. Function The AC input voltage U I is rectified in order to operate consumers with DC voltage U O. Also, voltage peaks, which occur when switching off inductive loads and which may cause damage to insulation and contacts, are limited and the contact load reduced. Dimensions (mm) Electrical Connection (Terminals) + Input voltage 3 + 4 Connection for an external switch for DC-side switching + 6 Coil 7 0 Free nc terminals (only for ) ØD A C E 9 B Order Number / 0. 0 0 0. 6 up to 4 4 Half-wave rectifier Bridge rectifier A B C ØD E 34 30 3. 4. 4 30 44 4..0 3/4 64 30 4 4..0 Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 8030 6 Technical Data Bridge rectifier Half-wave rectifier Calculation output voltage VDC = VAC x 0.9 VDC = VAC x 0.4 Type /0 /0 /04 /04 3/04 4/04 Max. input voltage ± 0 % U I [VAC] 30 30 400 400 00 600 Max. output voltage U O [VDC] 07 07 80 80 70 Output current 0 C I RMS [A].. 3.0 4.0 4.0 4.0 at max. 8 C I RMS [A].7.7.8.4.4.4 Max. coil nominal capacity at U AC = VAC 0 C P N [W] 60 60 - - - - up to 8 C P N [W] 77 77 - - - - U AC = 30 VAC 0 C P N [W] 7 7 3 46 46 46 up to 8 C P N [W] 3 3 87 0 0 0 U AC = 400 VAC 0 C P N [W] - - 40 70 70 70 up to 8 C P N [W] - - 34 43 43 43 U AC = 00 VAC 0 C P N [W] - - - - 900 900 up to 8 C P N [W] - - - - 40 40 U AC = 600 VAC 0 C P N [W] - - - - - 080 up to 8 C P N [W] - - - - - 648 Peak reverse voltage [V] 600 600 000 600 000 000 Rated insulation voltage U RMS [V RMS ] 30 30 00 00 630 630 Pollution degree (insulation coordination) Device fuses To be included in the input voltage line. Recommended microfuse switching capacity H The microfuse corresponds to the max. possible connection capacity. If fuses are used corresponding to the actual capacities, the permitted limit integral I t must be observed on selection. FF 3. A FF 3. A FF 4 A FF A FF A FF A Permitted limit integral l t [A s] 40 40 0 00 0 0 Protection IP6 components, encapsulated / IP0 terminals Terminals Cross-section 0.4. mm (AWG 6-4) Ambient temperature [ C] - to +8 Storage temperature [ C] -40 to +8 Conformity markings UL, CE UL, CE UL, CE UL, CE UL, CE CE The installation position can be user-defined. Please ensure sufficient Installation conditions heat dissipation and air convection! Do not install near to sources of intense heat!

ROBA -switch Type 07._00. Application your reliable partner ROBA -switch fast acting rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ) as well as electromagnets, electrovalves, etc. Fast acting rectifier ROBA -switch 07._00. Consumer operation with overexcitation or power reduction Input voltage: 00 00 VAC Maximum output current I RMS : 3 A at 0 VAC UL-approved Function The ROBA -switch is used for operation at an input voltage U I of between 00 and 00 VAC, depending on the size. They can switch internally from bridge rectification U O output voltage to half-wave rectification U H output voltage. The bridge rectification time can be modified from 0.0 to seconds by exchanging the external resistor (R ext ). Dimensions (mm) Electrical Connection (Terminals) Type 07.000. + Input voltage (fitted protective varistor) 3 + 4 Connection for external contact for DC-side switch-off + 6 Output voltage (fitted protective varistor) 7 + 8 R ext for bridge rectification time adjustment 4 Ø4. 9 30 Technical Data 7. Input voltage see Table Output voltage see Table Protection IP6 components, IP0 terminals, IP0 R ext Terminal nom. cross-section. mm (AWG -4) Ambient temperature - C bis +70 C Storage temperature -40 C up to +70 C.6 4. 64 4 48. Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 ROBA -switch s, Table 3 Input voltage ± 0 % Type 07.000. Type 07.00. 0 0 0 0 U I [VAC] 00 0 00 00 00 0 00 00 Type 07.00. 4 Ø4. 9 Output voltage U O [VDC] 90 80 40 90 80 40 U H [VDC] 4 3 90 4 3 90 30 7. Output current at 4 C I RMS [A].0.8 3.0.0 at max. 70 C I RMS [A].0 0.9..0 Conformity markings up to 300 V.6 4. 64 4 Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 Order Number / 0 7. 0 0. 0 73.6 0 0 0 UL-approved up to 300 V up to 00 V 69 7

ROBA -switch Type 07.0. Application your reliable partner ROBA -switch fast acting rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ) as well as electromagnets, electrovalves, etc. Fast acting rectifier ROBA -switch 07.0. Integrated DC-side disconnection (shorter connection time t ) Consumer operation with overexcitation or power reduction Input voltage: 00 00 VAC Maximum output current I RMS :. A UL-approved Function The ROBA -switch with integrated DC-side disconnection is not suitable for being the only safety disconnection in applications! Dimensions (mm) The ROBA -switch is used for operation at an input voltage of between 00 and 00 VAC, depending on the size. They can switch internally from bridge rectification U O output voltage to half-wave rectification U H output voltage. The bridge rectification time can be modified from 0.0 to seconds by exchanging the external resistor (R ext ). 4 Ø4. 9 30 7. Apart from this, the ROBA -switch has an integrated DC-side disconnection. In contrast to the usual DC-side disconnection, no further protective measures or external components are required. The DC-side disconnection is activated in standard mode (terminals 3 and 4 are not wired) and causes short switching times on the electromagnetic consumer..6 4. 64 4 Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 The integrated DC-side disconnection is deactivated by fitting a bridge between the terminals 3 and 4. The coil is de-energised via the freewheeling diode. This has the advantages of softer braking and a lower switching noise. However, this substantially lengthens the switching times (approx. 6 0x). 73.6 Electrical Connection (Terminals) + Input voltage (fitted protective varistor) 3 + 4 Switching between DC- and AC-side disconnection + 6 Output voltage (fitted protective varistor) 7 + 8 R ext for bridge rectification time adjustment 69 0 8 Technical Data Input voltage see Table Output voltage see Table Protection IP6 components, IP0 terminals, IP0 R ext Terminal nom. cross-section. mm (AWG -4) Ambient temperature - C up to +70 C Storage temperature -40 C up to +70 C Order Number / 0 7. 0. 0 0 ROBA -switch s, Table Input voltage ± 0 % Output voltage Output current Conformity markings 0 0 U I [VAC] 00 0 00 00 U O [VDC] 90 80 40 U H [VDC] 4 3 90 at 4 C I RMS [A].. at max. 70 C I RMS [A] 0.7 0.7

ROBA -switch 4V Type 08.000. Application your reliable partner ROBA -switch 4V fast switching modules are used to operate DC consumers with overexcitation or power reduction, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ), electromagnets, electrovalves, etc. Fast switching module ROBA -switch 4V 08.000. Consumer operation with overexcitation or power reduction Integrated DC-side disconnection (shorter connection time t ) Input voltage: 4 VDC Max. output current I RMS :. A CAUTION The ROBA -switch 4V with integrated DC-side disconnection is not suitable for being the only safety disconnection in applications! Dimensions (mm) 4 Function The ROBA -switch 4V units are used for an input voltage of 4 VDC. They can switch internally, meaning that the output voltage switches to holding voltage from the input voltage (= overexcitation voltage) via pulse-width modulation using 0 khz. The overexcitation time and holding voltage can be switched. Electrical Connection (Terminals) Control input + 3 Input voltage, ground 4 + Input voltage +4V 6 Output voltage + 7 Output voltage - 8 + 9 Selection of overexcitation time 9 + 0 Selection ofholding voltage.6 Ø4. 4 4. 64 9 30 48.6 7. Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 Technical Data Input voltage U I 4 VDC (8 3 VDC) SELV/PELV Output voltage U O Input voltage U I Output voltage U H see Table Output current I RMS at 4 C. A Output current I RMS at max. 70 C Protection. A IP6 components, IP0 terminals Terminal nominal cross-section. mm² (AWG -4) Ambient temperature - C up to +70 C Storage temperature -40 C up to +70 C ROBA -switch 4V, Table Article number Overexcitation time t O [ms] Holding voltage U H [VDC] without with without with Bridge 8+9 Bridge 9+0 8378 40 0 ½ x U I / U I Order Number / 0 8. 0 0 0. Example: Order number / 08.000. and article number 8378 9

3 4 6 7 8 9 0 ON ON ROBA -switch 4V Type 08.00. Application your reliable partner ROBA -switch 4V fast switching modules are used to operate DC consumers with overexcitation or power reduction, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ), electromagnets, electrovalves, etc. Fast switching module ROBA -switch 4V 08.00. Consumer operation with overexcitation or power reduction Integrated DC-side disconnection (shorter connection time t ) Input voltage: 4 VDC Max. output current I: A UL-approved CAUTION The ROBA -switch 4V with integrated DC-side disconnection is not suitable for being the only safety disconnection in applications! Dimensions (mm) Ø4. 4 9 Function The ROBA -switch 4V units are used for an input voltage of 4 VDC. They can switch internally, meaning that the output voltage switches to holding voltage from the input voltage (=overexcitation voltage) via pulse-width modulation using 0 khz. The overexcitation time can be adjusted via a DIP switch to 0 ms, 40 ms, s,. s and. s. The holding voltage can be adjusted via a further DIP switch to ¼, /3, ½ and /3 of the input voltage (equals 6 V, 8 V, V and 6 V at an input voltage of 4 V)..6 4. 64 4 30 7. Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 Apart from this, the ROBA -switch 4V has an integrated DC-side disconnection. In contrast to the usual DC-side disconnection, no further protective measures or external components are required. The DC-side disconnection is activated in standard mode and causes short switching times on the electromagnetic consumer. This can, however, be deactivated by installing a bridge between terminals 7 and 8 in order to produce soft brakings and quieter switching noises. However, this substantially lengthens the switching times (approx. 6 0x). 69 3 4 3 4 0 73.6 Electrical Connection (Terminals) + 3 Input voltage, ground 4 Control input 7 Input voltage + 4 VDC 8 + 9 Output voltage + 0 Output voltage - Technical Data Input voltage U I 4 VDC + 0 % / - 0 % Output voltage U O SELV/PELV 0 Input voltage U I Output voltage U H ¼, /3, ½, / U I ± 0 % can be selected via a DIP switch Output current I RMS at 4 C.0 A Output current I RMS at max. 70 C. A Protection IP00 Terminal nominal cross-section. mm² (AWG -4) Ambient temperature - C up to +70 C Storage temperature -40 C up to +70 C Order Number / 0 8. 0 0.

ON your reliable partner ROBA -brake-checker Type 08.00. Application ROBA -brake-checker monitoring modules are used to operate safety brakes with overexcitation while at the same time monitoring the condition. Monitoring module ROBA -brake-checker 08.00. Consumer operation with overexcitation or power reduction Controlled output voltage (on reduction) Simple adjustment of holding voltage and overexcitation time via a DIP switch Fast or slow switch off Brake condition recognition (release and drop-out recognition) Wear recognition and error recognition Wide input voltage range Maximum output current I RMS : 0 A / A Maximum overexcitation current I O = 0 A / 0 A Automatic reduction of the holding voltage U H Dimensions (mm) 4 CAUTION The ROBA -brake-checker with integrated DC-side disconnection is not suitable for being the only safety disconnection in applications! Ø4. 9 30 7. Function The ROBA -brake-checker monitoring module is intended for use with an input voltage of 4 or 48 VDC. The module monitors the switching condition of the brake and emits a signal to provide information on the respective switching condition. Critical conditions (line breakages, wear) can be recognised and the respective signal can be emitted via the warning signal output. Switching of the output voltage to a controlled holding voltage (see Table ) is available as an option. After a brake-specific overexcitation time period, the integrated automatic mode adjusts to the pre-set reduction voltage. The automatic mode can be switched off using a DIP switch. Electrical Connection (Terminals) Power Terminal Supply voltage +4 VDC / +48 VDC Output voltage + 3 Output voltage - 4 Supply voltage 0 VDC Signal Terminal Supply voltage 0 VDC Switch-off fast/slow (input) 3 Signal output (release monitoring) 4 4 V (auxiliary voltage for bridging) Supply voltage +4 VDC 6 Start (input) 7 Error output max. 300 ma Technical Data Input voltage see Table Output voltage see Table Protection IP6 components, IP0 terminals, IP0 DIP switch Terminal nominal cross-section Power terminals 4 mm, (AWG 0-) Signal terminals. mm, (AWG 30-4) Ambient temperature - C up to +70 C Storage temperature -40 C up to +0 C.6 Input voltage, power terminal Input voltage, signal terminal Output voltage Output current 3 4 6 7 8 ROBA -brake-checker s, Table Conformity markings Order Number 4 4 VDC 48 VDC SELV/PELV U I [VDC] 8 30 4 4 U I [VDC] 4 (9 8) ± % U O [VDC] Input voltage U I 6 8 6 ± % U H [VDC] 6 4 3 at 4 C I RMS [ADC] 0.0.0 at max. 70 C I [ADC].0. RMS / 0 8. 0 0. 4 4. 64 4 69 0 73.6 Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809

ON ROBA -multiswitch Type 09._00. Application your reliable partner ROBA -multiswitch fast acting rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ) as well as electromagnets, electrovalves, etc. Fast acting rectifier ROBA -multiswitch 09._00. Consistently controlled output voltage in the entire input voltage range Consumer operation with overexcitation or power reduction Input voltage: 00 00 VAC Max. output current I RMS : A; 4. A UL-approved ROBA -multiswitch units are not suitable for all applications, e.g. use of the ROBA -multiswitch when operating noise-damped brakes is not possible without taking additional measures. The product s suitability should be checked before use. Dimensions (mm) 4 Ø4. 9 Function The ROBA -multiswitch is used for operation at an input voltage of between 00 and 00 VAC, depending on the size. After switchon, it emits the rectified bridge voltage for 0 ms and then adjusts automatically to a pre-programmed overexcitation voltage. After the overexcitation time ends, it regulates to the permanently programmed holding voltage. For the overexcitation voltage and holding voltage values of the standard design, please see Table. On special designs, deviating values are possible. The overexcitation time can be adjusted via a DIP switch to 0 ms, 40 ms, s,. s and s. Electrical Connection (Terminals) + Input voltage (fitted protective varistor) 3 + 4 Connection for external contact for DC-side switch-off + 6 Output voltage (fitted protective varistor) Technical Data Input voltage see Table Frequency 0 60 Hz Output voltage see Table Output current Type 09.00. A at 4 C; A at max. 70 C Type 09.00. 4. A at 4 C;. A at max. 70 C Protection IP6 components, IP0 terminals, IP0 DIP switch Terminal nominal cross-section. mm (AWG -4) Ambient temperature - C up to +70 C Storage temperature -40 C up to +70 C Order Number / 0 9. 0 0. 0 0 max..0 A I RMS max. 4. A I RMS.6 3 4 ROBA -multiswitch s, Table Type Input voltage * Output voltage * Article number ± 0 % ± 0 % acc. EN 060 U O ** U H ** [VAC] [VDC] [VDC] 0 09.00. 00 7 90 88686 0 4. 64 4 69 09.00. 00 00 80 04 889 09.00. 00 00 80 04 8494 09.00. 30 07 30 880 09.00. 30 07 30 837887 09.00. 300 00 40 8094 * On special designs, deviating values are possible. The values stated on the Type tag are decisive. ** U O : overexcitation voltage; U H : holding voltage 30 73.6 (Type 09.00.) 03 (Type 09.00.) 7. Accessories: Mounting bracket set for 3 mm rail acc. EN 607: Article No. 809 Example: Order number 0 / 09.00. and article number 880

Application your reliable partner Spark Quenching Unit Type 070.000.6 Reduces spark production on the switching contacts occurring during DC-side switch-off of inductive loads. Voltage limitation according to VDE 080 000-07, Item 4.6. Reduction of EMC-disturbance by voltage rise limitation, suppression of switching sparks. Reduction of brake engagement times by a factor of 4 compared to freewheeling diodes. Function The spark quenching unit will absorb voltage peaks resulting from inductive load switching, which can cause damage to insulation and contacts. It limits these to 70 V and reduces the contact load. Switching products with a contact opening distance of > 3 mm are suitable for this purpose. Dimensions (mm) Electrical Connection (Terminals) (+) Input voltage ( ) Input voltage 3 ( ) Coil 4 (+) Coil Free nc terminal 6 Free nc terminal Ø3. 34 4. 30 9 Technical Data Input voltage max. 300 VDC, max. 6 V peak (rectified voltage 400 VAC, 0/60 Hz) max. 9 J / ms max. 0. Watt Switch-off energy Power dissipation Rated voltage nc terminals Protection Ambient temperature - C up to +8 C Storage temperature -40 C up to +8 C Max. conductor connection diameter. mm / AWG 6- Max. terminal tightening torque 0. Nm 0 V IP6 components, IP0 terminals Accessories Mounting bracket set for 3 mm rail acc. EN 607: Article No. 8030 Order Number / 0 7 0. 0 0 0. 6 3

ROBA -SBCplus The safe brake control - for use up to PLe and SIL CL3 Application The safe brake control ROBA -SBCplus is used to control and monitor two ROBA-stop safety brakes, especially in applications, which have to fulfill requirements regarding person protection according to the standards for functional reliability, such as for example ISO 3849 and IEC 606. Patent pending 4 Characteristics: Safe electronic switching of two brakes Input voltage power circuit 4-48 VDC Connection for up to brakes up to 4. A / 4 VDC or. A / 48 VDC (08 W) Output voltage (holding voltage) can be selected 6,8,,4,48 VDC Power reduction, temperature reduction, electricity costs reduction Overexcitation time configurable Feedback inputs release monitoring for proximity switch or microswitch Monitoring for plausibility of the feedback Error diagnostics of the brake Status and error outputs for feedback to the control No mechanic contacts for controlling and monitoring High reliability, no wear, independent of cycle frequency and cycle rate Fast ( DC-side ) or slow ( AC-side ) switch off possible Galvanic separation between the control part and the power part Prevention of EMC issues Four integrated functions: Contactor, 4 VDC fast-acting rectifier, safety relay, spark quenching Safe holding voltage and overexcitation time Safety functions are programmed into the RO- BA -SBCplus and only have to be parameterised Plausibility check integrated and must not be programmed and validated Applicable up to PLe and SIL CL3, Type examination TÜV Süd (German Technical Inspectorate) Maximum switching reliability The brake control must safely interrupt the current in the magnetic coil on switching off the brake. The RO- BA -SBCplus module works with wear-free electronic semiconductors and thus achieves almost unlimited switching frequencies and switching reliability. Safe inner configuration Amongst other things, the internal diagnostics inspections for short circuits, earth short-circuits and line breaks as well as safe overexcitation for releasing the brake and switching to reduced holding voltage when the brake is opened are the components required for fail-safe inner configuration. Numerous safety functions Numerous safety functions permit comprehensive error diagnostics. The brake voltage is monitored. An excessively high voltage could dangerously extend the drop-out time on switch-off, if, for example, this were to cause a vertical axis to drop to an unpermittedly low level. The monitoring of the switching times, which influence the braking distance, is therefore another component of error diagnostics. Safe switching condition monitoring The signal evaluation of the release monitoring with plausibility check permits a switching condition monitoring of the brake. The plausibility is controlled as follows: If voltage is applied, the brake must be opened after a defined time and vice versa. The switching condition monitoring can be used to reliably prevent the drive starting up against a closed brake. In this way, creeping errors, such as gradually increasing wear, which affects the switching times, can be detected.

ROBA -torqcontrol Adapted braking - Intelligent braking torque control module In contrast to car brakes, safety brakes can only distinguish between two operating conditions due to their design, namely braking torque present and no braking torque present. This is the reason why every braking procedure is carried out with the maximum braking torque available. Just as in a car, gradual, even deceleration is also often desired for devices and machine applications with dynamic braking actions. The new, intelligent braking torque control module ROBA -torqcontrol by mayr power transmission therefore offers an economically attractive solution to generate a variable braking torque for ROBA-stop safety brakes, making it possible to decelerate machines evenly and gently. Continuous braking torque changes when in operation Up to now, brakes have been dimensioned with regard to the maximum load where devices with variable loads, for example forklift trucks, are concerned. In case of partial loads, a stronger deceleration than necessary with the full braking torque can lead to damage to the transported goods or even to sliding of the wheels. If, however, the system detects the operating conditions and converts this information into a default signal for the new, intelligent control module by mayr power transmission, electronic braking torque regulation is possible. Using the new system, the brake specialists have succeeded in continuously changing the contact force on the brake linings and therefore also the braking torque during operation. In this way, machines can be decelerated smoothly, adapted to the respective system requirements. Using the new, intelligent control device by mayr power transmission, the resulting clamping force for the brake rotor can be specified to %, 0% or 7% of the nominal spring force by means of two digital inputs. Alternatively, a continuous, analogue default signal from 0 to 0 V is possible. The switching device determines without using a sensor whether the armature disk is attracted or has dropped. This makes it possible to adjust the overexcitation time automatically as desired. With the new braking torque control module, mayr power transmission provide the possibility to build up control circuits and brake movements intelligently ideal prerequisites for application in the smart, interconnected machines of the future. Technical Data Supply voltage Output current Inputs Outputs Adjustable voltage reduction/overexcitation Automatic overexcitation time or manually adjustable Release and drop recognition for safety brakes Dimensions L x W x H Intelligent braking torque control module ROBA -torqcontrol 4 V or 48 V 0 A or A Start/Stop digital braking torque pre-selection %, 0%, 7% or analogue 0 0 V equals 00% torque release signal 0 69 x 30 mm