UP6-PV 12V UP6-PV 24V

Similar documents
US - UP2/OIL 12V US - UP2/OIL 24V

UP14-PV 12V UP14-PV 24V

TK1/2 12/24V TK2/2 12/24V

US - UP3-R 12V US - UP3-R 24V

C - UP6/A-AC 220V

UP9/E 12/24V

US - UP2/E 12/24V

DP9/E 12/24V

UP66/E-DX 12V UP66/E-DX 24V UP66/E-DXP 12V UP66/E-DXP 24V

UP12/E-DX 24V

C - VP45/AC 220V

UP6A 12 V UP6A 24 V

DP12 12 V DP12 24 V

SP2 12V / 24V

M-3025CB-AV Fuel Pump

POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE

TPHK Series Immersible Pump

12v / 24v Diesel Transfer Pump Kit

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

PNEUMATIC PUMP Series

TPHK Series Immersible Pump

POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Mod: KLD6-12/35XLAS-N

80 Litre Suction Oil Drainer With Inspection Chamber

TPAK Series COOLANT PUMP

SUBMERSIBLE WATER PUMP

ESE Series Cast Iron Sewage Pumps

MOD. MASTER METER INSTALLATION OPERATION AND MAINTENANCE. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

G8 Portable Fuel Transfer Pump Owner s Manual

BELT CONVEYOR CB/M5 Series

AdBlue Electric Transfer Pump 12V & 24V DC

Matala. VersiFlow Series. Instruction and Maintenance Manual

Swing Piston Compressors and Vacuum Pumps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SUBMERSIBLE WATER PUMP

A408 GB. Pneumatic oil and diesel pumps 1:1

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

GARDEN HOSE UTILITY PUMP

MICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

User s manual. Air purifier ZeroAir

BELT CONVEYOR PNL/4 Series User and maintenance manual

Model &

Micro Diaphragm Gas Sampling Pumps

Type 6213 EV, 6281 EV

Instruction and Maintenance Manual

240V AdBlue Electric Transfer Pump

ENGINE DRIVEN 3 FULL TRASH PUMP

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

June14. Type

RIDUTTORE PER MOTORI ENDOTERMICI REDUCTION GEAR FOR GASOLINE & DIESEL ENGINES

12V Oil Extractor Pump

User s Manual. Automatic Switch-Mode Battery Charger

MOUNTING INSTRUCTIONS

ILED Aquarius Illuminated Windsock. User Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OWNERS MANUAL ECODIVER

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

GeyserMax-Flow Series

DIAPHRAGM PUMPS: Instruction Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Telescopic Sliding doors SLT series

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

AUTOMATIC AIRSPRAY GUN

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , ,

CFT24 &CFT230 PART NOS:

Water pump Owner's Manual

Battery Booster Pack. Instruction Manual for P/N

SUBMERSIBLE DIRTY WATER PUMP

Troubleshooting 3Z8 038 Rev B

240V AdBlue Transfer Pump Stations

DIAPHRAGM LIQUID PUMP NF 1.30

5. FUEL SYSTEM FUEL SYSTEM 5-0

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

1200W INVERTER GENERATOR

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

SUBMERSIBLE WATER PUMP

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

OWNER S MANUAL PRODUCT CODE: BOD1907

DIAPHRAGM LIQUID PUMP NF 2.35

Operation & Service Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

P-200 Plastic Utility Pump for Petroleum Products

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Plunger Heads Use and Maintenance Manual

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Voltmaster Centrifugal Trash Pumps

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

VB Unloader Valve (discharging)

SIZING OF SOLAR GENERATOR

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

XT Winches. Installation and Maintenance Manual XT16.2AL, XT16.2CH, XT16.2R XT30.2AL, XT30.2CH, XT30.2R

Transcription:

ELETTROPOMPA AUTOADESCANTE PER TRAVASO LIQUIDI SELF-PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS AVVERTENZE D USO INSTRUCTIONS FOR USE 6/03/ Rev.05 6 063 - UP6-PV V 6 063 3 - UP6-PV V 0

ATTIVAZIONE VALVOLA DI SFIATO / AIR VENT VALVE ACTIVATION Al primo avvio della pompa, oppure in caso di svuotamento del serbatoio, agire brevemente sulla valvolina manuale per sfogare l'aria e favorire l'adescamento pompa. Una volta azionata la pompa, richiudere la valvolina. When starting the pump, or when emptying the tank, slightly open the small valve, in order to let the air out and facilitate the pump priming. As soon as the pump is operating close the small valve. 0

PRODUCT DESCRIPTION A Self-priming electric pump for the transfer of liquids of varied nature (except those listed in section G) for discontinuous or intermittent usage. The pumping elements are made up of PTFE gear drives which can possibly even run dry for brief periods. Completely equipped with in-line filter on the inlet side and integrated check valve. TECHNICAL DETAILS B CODE TYPE 6 063 UP6-PV 6 063 3 C VOLT FUSE FLOW RATE PRESSURE 6 l/min bar 5 A 7,5 A WEIGHT P.CS x CART. 3, kg 6 AMBIENT CONDITIONS TEMPERATURE: min. -0 C / max. +60 C RELATIVE HUMIDITY: max. 90 % WARNING: the above indicated temperature ranges are applicable to all components of the the pump and these limits must be respected in order to avoid any possible damage or malfunctioning. D ELECTRICAL CONNECTIONS The electric pump must be connected to a source of direct current (either battery or DC power supply) with an amp rating of 5A (V) and 7,5A (V). The pump must be protected by suitable rated fuse. E OPERATING CYCLE The pump has been designed for discontinuous use. Under conditions of high operating pressures (eg. with closed or blocked outlet, excessive length of the delivery circuit and/or excessive pressure due to accessories), the pump can be subjected to elevated stresses and overheating and therefore should not be used for prolonged periods under such conditions. F APPLICATIONS There are numerous fields of applications for the pump, however only exclusively with the allowed liquids mentioned: - transfer of diesel fuel between tanks, refuelling of tractors and earth moving Equipment; - bilge pump for boats; - water pressure system; - transfer of light weight lube oils, antifreeze, etc. 8 0

FLUIDS ALLOWED / NOT ALLOWED G ALLOWED: FRESH WATER - SALT WATER NOT ALLOWED: RELATED DANGERS PETROL (GASOLINE) FLAMMABLE LIQUIDS with PM < 55 C LIQUIDS WITH VISCOSITY > 0 cst FOODSTUFF LIQUIDS CORROSIVE CHEMICAL PRODUCTS FIRE EXPLOSION FIRE EXPLOSION MOTOR OVERHEATING FOODSTUFF LIQUID CONTAMINATION PUMP CORROSION INJURY TO PERSONNEL FIRE EXPLOSION DAMAGE TO SEALS SOLVENTS TRANSPORTATION AND HANDLING H Due to limited weight and dimensions the pump does not require the use of any special handling or lifting equipment. When handling manually, normal personal protective gear should be worn (safety shoes with toe piece, etc.) The pump is carefully packed prior to shipment. Upon receiving, the pump packaging should be inspected for damages and the pump stored in a dry area. INSTALLATION I It is recommended that the use of the pump be according to normative safety standards and also as per the precautions listed below. PACKAGING ENVIRONMENTAL DISPOSAL I- The user is invited to effect a proper waste separation, in order to facilitate the recycling of the materials of which the packing is composed; disposal like CER 5.0.0/0 PRELIMINARY CHECKS I- Check that there has been no damage to the pump during transportation or storage. Both inlet and outlet ports should be carefully cleaned removing possible dust or residual packaging material. Verify that the available electrical power supply corresponds to the pump specification requirements. POSITIONING OF THE PUMP The pump can be mounted in any position. Fix the pump utilizing suitable screws corresponding to the antivibration mounts supplied with the pump. 9 0 I-3

WARNING: THE PUMP MOTOR IS NOT EXPLOSION PROOF. Do not install the pump where flammable vapours or gases may be present. Install the pump in an accessible place for inspection. It is good practice to avoid any pump contact with water splashes. TUBING CONNECTIONS I- Ø Ø Ø Ø Ø Prior to making any tube/hose connections, check that the inlet ports have no end caps; Do not position the pump at a excessive height with respect to the minimum level of the fluid to be transferred. Damage may occur if this height is exceeded as the pump may not draw fluid. Make sure that the outlet tube is empty and without chokes; Avoid choking the inlet or outlet tubes so that efficiency is optimized. The use of an inlet filter is recommended especially with fluids containing impurities (ASTM mesh 35). In this case frequent cleaning and maintenance of the filter is advisable. The standard filter withstands a maximum positive pressure of 0.5 bar. Utilize tubes and connection pieces that are resistant to the fluid types handled and avoid any possible environmental dispersion. PUMP INSTALLATION I-5 The electrical installation of the pump must include a protection fuse which is suitably rated as indicated on the motor label. WARRANTY EXPIRES IF NO FUSE IS UTILIZED Always mount the anti vibration rubber fittings supplied with the pump kit. Their usage ensures a consistent reduction in noise and vibration levels. Electrical cabling size should depend on the distance between pump and battery power supply. Up to m length: mm The use of undersized cabling can cause overheating of the electrical wiring and subsequent fire hazard. There will also be a voltage drop at the motor terminals with a consequent reduction in efficiency. The flow rate value indicated on the motor label is obtained with a 6 mm internal tube diameter. Tubes with inferior diameters will cause an increase in current with potential risk of motor overheating. 0 0

To ensure the correct directional flow of the fluid as indicated by the arrow on the top of the pump, it is necessary to connect the positive pole ( + ) of the battery supply to the red wire on the motor end-cap and the negative pole ( - ) to the black wire. Electrical connections must be made using adequate terminal blocks and connectors ensuring a tight fitment of the electrical cables. Bad wiring can cause power losses and/or overheating of the cabling itself. WARNING: it is the responsibility of the installation technician to ensure a correctly designed circuit installation fitted according to regulations. Environmental risks must be taken into account with the installation. TROUBLESHOOTING L CHECK POINTS IF THE PUMP HAS STOPPED OR WILL NOT START L- - Check the effectiveness of the battery power supply (voltage activity); - Check if the fuse has blown; - Check for any foreign matter present in-between the pump gear drives. To do this, disconnect the power supply and unscrew the four fixing screws, remove the pump front cover plate and inspect the pump chamber. Replace the cover plate in the same initial position after inspection; - Avoid running the pump dry for more than a few minutes. Pumps found defective that have run dry in the absence of fluid are not covered by warranty; - The average life span of the motor commutator brushes is approximately 700 hours under normal operating conditions. Stoppages are possible due to brush wear and tear after such a time period. WHY THE PUMP WILL NOT PRIME ITSELF? L- - The pump is fitted at a height greater than,5m above the fluid level; - The pump has run dry for too long a period; - Long periods of inactivity. In this case it is advisable to add liquid directly into the pump chamber before start-up. It is also advisable to add, before running the pump, a drop of Lubricating oil inside the pump only; - Air leak at the suction pipe due to the following reasons: possible cuts in the pipe, inadequate hose clamps, malfunctioning of the filter due to defective/worn seals or filter clogged. - Air leak at the pump front plate cover due to the following reasons: loose fixing screws, poor effectiveness of the seal; - Faulty electrical cable connections; - Presence of obstructions or restrictions in the suction or delivery pipes or the use of special devices(eg. automatic spray pistol or aqua-stop); - Presence of liquid loops in the outlet tube. GOOD PRACTICES ENSURING A WELL FUNCTIONING PUMP L-3 No particular maintenance is required if the pump is utilized for the transfer of diesel fluids. If it is expected that the pump will not be used for a period of at least 30 days, especially in the case of usage with fresh or salty water, it is advisable to run fresh water through the pump and to then loosen the pump front plate screws. 0

Upon re-use, run the pump briefly (a few seconds) and then tighten the screws again. Check under conditions of maximum operating pressure that the motor current value is within the motor label specifications. L- NORMAL MAINTENANCE - Check frequently and keep the inlet filter clean. - Check every month the pump chamber and keep clean from any foreign matter. - Check every month that electrical wiring is in good condition. - Every 700 hours of pump operation substitute the motor brushes. - Every season check the mechanic of the pressure switch and keep it lubricated. L-5 INDICATORS THAT THE PUMP IS FUNCTIONING CORRECTLY - Temperature of pump body and motor frame is within 60 C - 70 C; - Regular flow and constant pump noise levels; - Amp-draw within the limits indicated in the technical details. L-6 TO OPEN THE PUMP It is recommended that a specialized service technician be consulted for any pump repair work or the replacement of worn out internal components, exclusively with original spare parts; During the warranty period, only by authorized Marco personnel, failing which the warranty will expire. M ENVIRONMENTAL DISPOSAL Do not dispose of pumps into household waste.pumps that are no longer usable, must be collected separately and disposed of in an environmentally correct manner. N WARRANTY.The Warranty period is years from date of purchase on production of the appropriate sales invoice.. Should the original sales invoice not be available, then the year warranty period will be valid from production date. 3. The Warranty becomes null and void in the case of incorrect utilization or disregard of the instructions contained herein.. The Warranty only covers original production defects. 5. The Warranty does not cover any related installation costs involved. 6. Transport costs are refundable only in the case where warranty has been duly recognized and accepted by Marco Spa. These costs will be limited to the actual shipment costs between Marco Spa warehouse and the client's delivery address. 7. No credit notes or replacement items will be issued prior to the receipt and proper testing of any Marco goods that are deemed faulty. 0

SCHEDA DI ASSEMBLAGGIO / EXPLODED VIEW Pos. Q.tà 3 5 6 7 8 9 0 3 5 Pos. Q.tà Descrizione CORPO ANELLO DENUTA PERNO TIRANTE INDOTTO CUSCINETTO ANELLO ONDULATO CARCASSA CALOTTA RONDELLA DADO VALVOLA DI NON RITORNO 6 7 8 9 0 3 5 6 7 8 9 30 O Descrizione NIPPLO INGRANAGGIO FOLLE LINGUETTA INGRANAGGIO TRAINANTE PIATTELLO VITE TAPPO DI SFIATO TAPPO NIPPLO PORTAGOMMA FILTRO ANTIVIBRANTE 3 7 0 6 8 8 7 5 9 9 6 3 7 3 7 30 5 8 5 6 9 7 0 8 Pos. Q.ty 3 5 6 7 8 9 0 3 5 Pos. Q.ty Description PUMP BODY RUBBER LIP SEAL IDLE SHAFT ROD ARMATURE BALL BEARING COMPENSATION SPRING PUMP FRAME BRUSH HOLDER WASHER NUT NON RETURN VALVE 6 7 8 9 0 3 5 6 7 8 9 30 3 0 Description NIPPLE IDLE GEAR KEY DRIVING GEAR TOP PLATE SCREW AIR VENT CAP CAP NIPPLE TUBE OUTLET FILTER ANTIVIBRATION MOUNT

INGOMBRI / DIMENSIONS P 8 98 80 58 7 3 9 7 38 0 78 09 70 39 60 5 98 60 0

DIAGRAMMI / DIAGRAMS Q DIAGRAMMA PORTATA FLOW RATES DIAGRAM 30 l/min 5 0 5 0 5 0 0 0,5,5,5 bar DIAGRAMMA ASSORBIMENTI AMPERE-DRAW DIAGRAM 0 V A 5 0 V 5 0 0 0,5,5 bar 5 0,5

Associato AIB associazione industriale bresciana DICHIARAZIONE DI CONFORMITA C.E. E.C. DECLARATION OF CONFORMITY Confermiamo che il prodotto: We confirm that the product: 6 063 - UP6-PV V Pompa ad ingranaggi 6 l / PTFE Gear pump 6 063 3 - UP6-PV V Pompa ad ingranaggi 6 l / PTFE Gear pump E conforme alla Direttiva 00/08/CE (ex.89/336/ce) relativa alla Compatibilità Elettromagnetica. Is in conformity with the Directive 00/08/EC (ex.89/336/ec) relating to Electromagnetic Compatibility. Questa dichiarazione è valida per tutti gli articoli prodotti secondo la documentazione tecnica che è parte di questa dichiarazione. In caso di eventuali verifiche pertinenti alla Compatibilità Elettromagnetica sono state applicate le seguenti normative: This declaration is valid for all products which are produced in accordance with the technical documentation which is a part of this declaration. For verification of conformity with regard to Electromagnetic Compatibility the following standards are applied: EN 550- Compatibilità elettromagnetica. Requisiti per gli elettrodomestici, gli utensili elettrici ed apparecchi similari. Parte : Emissione. Electromagnetic compatibility. Requirements for household appliances, electric tools, and similar apparatus. Part : Emission. Questa dichiarazione è rilasciata sotto la responsabilità esclusiva di: This declaration is given under the sole responsibility of: MARCO S.P.A. Via Mameli 0-50 Castenedolo - Brescia - Italy Tel. 030/3. Fax 030/3.300 6 0

NOTE / NOTES 7 0

NOTE / NOTES 8 0

NOTE / NOTES 9 0

Per ulteriori informazioni vedere nostro sito internet - www.marco.it Marco S.p.A Via Mameli 0-50 Castenedolo (Brescia) - Italia tel. +39 030 3. / Fax +39 030 3.300 For further information visit our web site - www.marco.it Marco S.p.A Via Mameli 0-50 Castenedolo (Brescia) - Italy tel. +39 030 3. / Fax +39 030 3.300