& DEPYROGENATION OVENS

Similar documents
GMP dry heat ovens for depyrogenisation and sterilisation

DEPYROGENATING TUNNELS

Mobile recleanable HEPA filter units for a flow of m 3 / h

Vari-Disk Service. Inline disc filters to meet your needs. Inlet and outlet connectors. Filter housing

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with mechanical convection

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

RHF hightec RH13 / H Mobile recleanable filter unit

Heating oven with mechanical control

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Safety drying ovens. Advantages: Areas of application: FDL series 115

Heating oven with natural convection

Multiport Valves. Why Multiport Valves?

Introducing NJK Precision Airflow Measuring Stations

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

A CLEAN AIR WORLD. Rigid, gas tight, shock and vibration resistant. Operating pressure guaranteed to ± 8000 Pa. Functional design, userfriendly

INSERTION flow sensor for continuous flow measurement

HAAKE Viscotester VT550 Plug & Play Application Packages

CM5-6 A-R-A-E-AQQE C-A-A-N

Multiport Valves. Why Multiport Valves?

INSTALLATION INSTRUCTIONS

Cutting-edge technologies backed by a century of experience

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Short Form Catalogue AJ Thermosensors

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Process Industry. Diaphragm Seal Solutions

C.3 CHRONO MISCELLANEOUS. Contents. turn-tilt- and tilt-turn window

CM1-2 A-R-A-E-AQQE F-A-A-N

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Process Filtration From Pure to Sterile

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

ABS System. Inductive Digital Comparator µmaxµm. Features. Technical Data. The most valueable electronic indicator for high production measurements.

Refrigerated incubator with Peltier technology

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Your Brakes. Fundamentals of Braking

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Process Filtration From Pure to Sterile

User Manual dpette+ Electronic Pipette 2016-ver.1

CM5-5 A-R-G-V-AQQV F-A-A-N

For air / gas dampers and control valves of oil or gas burners

ABS submersible sewage pump AFP

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Safety drying ovens with expanded temperature range

geoliner 680 and geoliner 780

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

CM3-5 A-R-I-E-AQQE F-A-A-N

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Safety drying oven with expended temperature range

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

CM1-8 A-R-I-E-AQQE F-A-A-N

A. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6

Closed-loop pressure and flow control system

Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method) 1

Accurate to 0.1 NIST Traceable Advanced PID Algorighm USB Port Free datalogging/control software. Controllers I N S C O N TA G N

ACCESSORIES AND DIAPHRAGM SEAL

DATA & FACTS Clean Rooms Fresh Heaven MAXX Fresh Heaven MAXX POWER. Laminar Air-Flow Units for Industrial Applications and Ceiling Installation

TPE /2-S-A-F-A-BAQE 3X400 50HZ

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

CM3-11 A-R-G-E-AQQE F-A-A-N

Combustion Control Problem Solution Combustion Process

MEPFSGEN. Pall Polypropylene Filters Selection Guide

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

CM10-1 A-R-A-E-AQQE F-A-A-N

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Process Filtration From Pure to Sterile

CM3-6 A-R-G-E-AQQE C-A-A-N

Gerotor pump, fixed displacement volume

Process Filtration From Pure to Sterile

PFLT008ENc. Pall Polypropylene Filters Selection Guide

VFC-5 to VFC-500 FLO-COATER

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :


The PMAC Dynamic Scale Loop

Mediclean Complanate Ultra Clean Ventilation

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

Undercarriage Systems and Support UNDERCARRIAGE

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

FLEXIBLE CONDUIT SYSTEM

JIS G4051 Carbon steel for Machine Structural Use

CM5-9 A-R-I-E-AQQE F-A-A-N

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

CM10-3 A-R-G-V-AQQV F-A-A-N

Nuclear Qualified Temperature Switches

JC BALL VALVES ASSEMBLY AND MAINTENANCE MANUAL

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

Transcription:

FOD Class

Sterilization and depyrogenation ovens represent an important product line with Fedegari, introduced in the late 19s thanks to an agreement with Vismara, followed by thirty years of technical and business cooperation. FOD ovens, like autoclaves, develop a discontinuous (batch-type) process and are intended for sterilizing different solids, such as glassware, parts of filling machines and stainless steel tanks and containers in general; they represent the ideal solution for any production when the variability of products, batches and formats does not allow the use of continuous sterilizers, such as tunnels. The distinctive feature of these sterilizers lies in particle contamination class. In order to ensure that both machine and process comply with the requirements of Federal Standard 209 E, Fedegari, as usual, has broken down the oven into its main elements for understanding the technology and the relevant limits. Then, Fedegari has developed appropriate solutions for each of them. The results are innovative and original. Detail view of the door. Note the tubular silicone gasket, which is seated in its slot without any locking device; the corners have a wide bending radius. Also note one of the wedge-shaped locking lugs. Detail view of the chamber. Note one of the three locking rollers which, by sliding upward, engage the three wedge-shaped lugs. At the same time, Fedegari has cooperated with a leading Italian research center in the development of a special high temperature air sampling device. Thanks to these activities, the measurements taken are, from a scientific standpoint, absolutely reliable and such a critical result has not been invalidated by a primitive and inadequate detection system. The company has thus ensured a particle contamination level in the chamber that does never exceed the values prescribed by the class not even during transient phases (the most critical), such as heating and cooling, during which the filters release considerable amounts of particles, due to temperature-related deformations. What characterizes Fedegari ovens compared to alternative products? Process performance (particle contamination, temperature uniformity, process repeatability), the specific features of these sterilizers and other details common to all Fedegari machines! FOD Class

The winning cards of FOD ovens are represented by uniform performance, regardless of dimensional variables. The use of design and production models ensure reproducible performances also with machines of very different size. Considering the constructional variability, typical of custom manufacturing, design and production models are a critical factor which will save a lot of time during installation and validation, when no emergency, and usually makeshift, solutions are required to face any shortcoming, such as door tightness, process times other than those estimated or lack of temperature uniformity with real product batches. The use of common components, such as the process controller (i.e. hardware and software) or other electrical and piping devices, ensure a more economical operation-characteristics emerging from any machine manufactured by Fedegari. From a technical standpoint, Fedegari ovens are the most performing and value for money solution to discontinuous sterilization problems in the pharmaceutical industry. Don t you believe it? Ask us to prove it! A view of the batteries of HEPA circulation filters with 99.97% retention. The air flow deflector has been removed. Note one of the two pressure sampling devices (the one located downstream) for measuring the pressure loss across the HEPA circulation filters. Detail view of the air flow deflector individually adjustable. Stainless steel fan, manufactured in-house. The vanes are force-fitted and then continuously welded to the two supporting disks; the hub is fixed to the base disk without using threaded devices. This allows to reduce the weight of the fan by 40%, increases its efficiency and keeps it constant in time, simplifies balancing and drastically reduces noise. FOD Class

Prefilter and HEPA filter on the chamber pressurization loop. Differential pressure transducer. Electric heating coil with proportional control. Drive unit for the circulation fan. Fan drive package of a special design as it also includes the mechanical seal. The shortened shaft is hardened with a special process where the seal works. The HEPA filter at the end of the exhaust duct protects the chamber against back-flow contamination. Stainless steel water cooling coil. The quick-coupling of the piping are the same as for the autoclaves. Pt, four - wire, 1/3 DIN RTD for main control located in a fixed position behind the air return flow deflector. Exhaust duct without conventional regulating damper. The frames of the circulation HEPA filters are constantly kept at a pressure lower than the chamber. The gasket of the filters automatically compensates for temperature changes. Set of 4 flexible Pt, four-wire, 1/3 DIN, RTDs in the chamber. FOD Class

FOD Class FOD MODEL USEFUL CHAMBER DIMENSIONS WIDTH HEIGHT DEPTH 2 DOOR VERSION USEFUL CHAMBER CAPACITY LITERS OVERALL EXTERNAL DIMENSIONS WIDTH HEIGHT DEPTH FOD 1/1 512 183 188 120 FOD 2/1 8 183 208 150 FOD 4/1 1 208 150 FOD 5/1 115 125 1440 223 165 FOD 6/1 2 185 FOD 6/2 1 2610 220 FOD 6/3 210 3050 250 FOD 8/3 160 210 3700 213 268 250 FOD 6/4 2 4060 320 FOD 8/6 160 2 4930 213 268 320 The above mentioned data are to be intended as indicative. The manufacturer reserves itself the right to change them without notice. The dimensions of the process controller and of the electric panel board must be added to the unit overall external dimensions. Contact the factory for non standard dimensions. Albuzzano (PV) - Italia - tel. +39 0382 434111 - fax +39 0382 434150 - www.fedegari.com