Packing Data Installation Instructions

Similar documents
Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Allen-Bradley 1397 Pulse Encoder Interface Card

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains

Global Dialysis - Cost per Dialysis Session

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

Imports of seed for sowing by country Calendar year 2011 Source: ISF compilation based on official statistics and international seed trade reports

BP Statistical Review of World Energy June 2017

FEDERAL RESERVE statistical release

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

9.01 ICT use for business-to-business transactions

Charging and testing unit FPU for Bladder, Piston and Diaphragm Accumulators

Global Competitiveness Index Rankings

Table 23 Production of minor oil products from refineries - by type Thousand metric tons

Infographics on Electromobility (January 2019)

Summary of debt securities outstanding

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

5.01 Secondary education enrollment rate

CSM-K. high capacity clean steam generator

Table 5 Production, trade and supply of hard coal Thousand metric tons and kilograms per capita

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

Table 5 Production, trade and supply of hard coal Thousand metric tons and kilograms per capita

Production of minor oil products from refineries - by type Thousand metric tons

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

2.01 Availability of latest technologies

Section III Macroeconomic environment

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

Microsoft Social Engagement Translation Guide Last Updated: October 2017

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min

LPI ranking and scores, 2014

control & instrumentation solutions The AEL6 series smart electric actuator

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Table 16 Refinery distillation capacity, throughput and output Thousand metric tons

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Production (bbl/day)

Spain s exports by oil product group and country of destination

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

CrimpTest-1 kn. Calibration Bracket

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Product Overview INCH

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

I. World trade in Overview

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Table 16 Refinery distillation capacity, throughput and output Thousand metric tons

19,000 38,500. Mean Crop. 5, ,827 Max , ,869 Last Year 6, ,

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

EVOline Socket Modules

Rectangular photoelectric proximity switches

D6.. Butterfly valves. For controlled operation.

World Air Conditioner Demand by Region

Coal. 36 Reserves and prices 38 Production and consumption. 67 th edition

35,000 52,000 87,000 1,600 8, ,400 76,600. Mean Crop. Monthly YTD Min ,671 8,211 Max. 2017

Spain s exports by oil product group and country of destination. Year Corporación de Reservas Estratégicas de Productos Petrolíferos

testing to perfection MultiTest-i Technical Datasheet

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

Potential Danger of Fire or Explosion Read this letter now!

Fiche 1 Quelques données de la Banque Mondiale


Summary of Contributions to UN Peacekeeping by Country and Post.

Spain s imports by oil product group and country of origin

The new STx chain hoist NEW. Sophisticated technology prepared for the future

Climate control for the future Holistic process protection

Natural gas. 26 Reserves 28 Production and consumption 33 Prices 34 Trade movements. 67 th edition

Citrus Fruit - Fresh and Processed Statistical Bulletin 2016

Instruments and accessories

FLUID REPLACEM Brake fluid and engine coolant (antifreeze and water solution) must be completely replaced at specific intervals. See table below. Your

AlixPartners Automotive Electrification Index. Second Quarter 2017

Spain s imports by oil product group and country of origin

YOUR PARTNER IN MIXING

2014/ /2015 Ghana / /2015 Syrian Arab Republic / /2015

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

The Great Transition: Shifting from Fossil Fuels to Solar and Wind Energy Supporting Data - Hydropower

World real merchandise trade grows faster than output

Fork through-beam sensors

testing to perfection MultiTest-i Technical Datasheet

Fork through-beam sensors

Kernel Wt. 533,229,317 1,005,999,479 1,539,228, ,964, ,947, ,911, Crop Year

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

STATISTICAL ANNEX NOTE ON QUARTERLY PROJECTIONS

UAE draft regulation for Electric Vehicle

up to and including 31 December 2002

Agrarfrost GmbH & Co. KG

SUMMARY OF GHG EMISSION FACTORS FOR PEPSICO INTERNATIONAL OPERATIONS

TASK FORCE TIPS. *** Automatic Nozzle ***

NI PS-15/16/17 Side Mount Brackets

sigma No 3/2009 World insurance in 2008 May 15, 2003 life premiums fall in the industrialised countries strong growth in the emerging markets

Production of heat by type Terajoules

High-current and generator switchgear from Siemens siemens.com/generatorswitchgear

Switzerland. A. Definitions and sources of data

Transcription:

Packing Data PK Installation Instructions This document describes how to install a Dataliner DL10 display in a panel or enclosure and connect power. European Union Directive Compliance wiring and safety guidelines enclosures required tools mounting dimensions clearances installing the DL10 display in a panel connecting AC power For more information on the Dataliner DL10 display, refer to the Dataliner DL10 User Manual (Publication 2706-800).

2 Dataliner DL10 Message Display European Union Directive Compliance If a Dataliner Message Display is installed within the European Union or EFTA regions and has a CE mark, the following regulations apply. EMC Directive This apparatus is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) using a technical construction file and the following standards in whole or in part. EN 50081-2 EMC Generic Emission Standard, Part 2 - Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 - Industrial Environment Dataliner products are intended for use in an industrial environment. Low Voltage Directive This apparatus is tested to meet Council Directive 73/23/EEC Low Voltage (LVD) with amendments, including 93/68/EEC using the pertinent sections of the following standards. EN 61131-2:1992 EN 60950:1992 Programmable Controllers - Equipment Requirements and Tests Safety of Information Technology Equipment Intended Use of Product According to these Standards, the factor which determines, for EMC purposes, whether an apparatus is deemed to be Industrial or Residential, commercial and light industrial, is given in Clause 1 of EN50081-2 as follows:

Dataliner DL10 Message Display 3 Apparatus covered by this standard is not intended for connection to a public mains network but is intended to be connected to a power network supplied from a high- or medium-voltage transformer dedicated for the supply of an installation feeding a manufacturing or similar plant. This product is intended for use solely in an industrial environment as defined above. When installed in Europe, any other application is in contravention of European Union Directives, and a breach of these laws. Wiring and Safety Guidelines Install the Dataliner DL10 display using publication 70E, Electrical Safety Requirements for Employee Workplaces. In addition to the NFPA general guidelines, follow these recommendations: Connect the Dataliner display to its own branch circuit. The input power source should be protected by a fuse or circuit breaker rated at no more than 15 amps. Route incoming power to the DL10 display by a separate path from the communications cable. Where power and communication lines must cross, they should cross at right angles. Communications lines can be installed in the same conduit as low level DC I/O lines (less than 10 Volts). Grounding minimizes noise from Electromagnetic Interference (EMI) and is a safety measure in electrical installations. To avoid EMI, shield and ground cables appropriately. A source for grounding recommendations is the National Electrical Code published by the National Fire Protection Association of Boston. Enclosures Mount the DL10 display in a panel or enclosure to protect the internal circuitry. The display meets NEMA Type 12/13, 4 (indoor use), and 4X (for stainless steel faceplate versions) ratings only when properly mounted in a panel or enclosure with the equivalent rating.

4 Dataliner DL10 Message Display Allow enough space within the enclosure for adequate ventilation. Consider heat produced by other devices in the enclosure. The ambient temperature around the display must be between 0 and 50 C (32 and 122 F). Make provisions for accessing the back panel of the display for wiring, maintenance, and troubleshooting. Required Tools Other than the tools required to make the panel cutout, the tools required for installation are: 3/8 inch deep well socket wrench small slotted screwdriver torque wrench (in. / lbs). Installing Display in Panel To install the Dataliner display:! ATTENTION: Disconnect all electrical power from the panel before making cutout. Make sure the area around the panel cutout is clear. Take precautions so that metal cuttings do not enter any components that may already be installed in panel. Failure to follow this warning may result in personal injury or damage to the panel components.

Dataliner DL10 Message Display 5 Mounting the DL10 The following figures provide panel cutout dimensions and overall dimensions for the DL10. You can mount the DL10 in a custom panel or enclosure. Dataliner enclosure Catalog Number 2706-NE2 (four-line display) is available. When the DL10 is properly installed, the faceplate of the DL10 provides a NEMA Type 12/13, Type 4 (indoor use only), and 4X (for stainless steel faceplate version) enclosure integrity. To install the DL10, perform the following steps: 1. Cut and drill the appropriate mounting holes in the enclosure or panel.! ATTENTION: Do not install the display in the panel or enclosure until all cutouts and holes are completed. Metal filings accumulated when cutting and drilling could enter ventilation holes on the display and cause the display to fail. 2. Remove the six mounting nuts from the hardware kit included with the DL10. 3. Position the DL10 in the panel or enclosure mounting hole. 4. Install and tighten the six nuts on the mounting studs to a torque of 14 in lbs (1.6N m) each.! ATTENTION: Mounting nuts must be tightened to a torque of 14 inch-pounds to provide a proper seal and to prevent potential damage to the display. Allen-Bradley assumes no responsibility for water or chemical damage to the display or other equipment within the enclosure because of improper installation.

6 Dataliner DL10 Message Display Mounting Dimensions Figure 1 Four Line Dimensions Dimensions in Inches (Millimeters) 0.12 Typ. (3.2) 13.30 (337.8) Top View 0.53 (13.5) Six 0.50 (12.7) Mounting Studs 14.37 (365.0) 8.83 (224.3) 1.63 (4.14) 2.94 (74.7) 6.18 (157.0) Front View 0.125 (3.2) (Gasket Thickness) 0.104 (2.6) (Panel Thickness) 0.53 (13.5) Side View 5.12 (130) 4.44 (112.8) 5.11 (129.8) 0.53 (13.5)

Dataliner DL10 Message Display 7 Clearances Allow adequate clearances for mounting, air flow, maintenance, and wiring. See Figure 2. Figure 2 Minimum Mounting Clearances Side, Top and Bottom Clearances Leave 25 mm (1 in.) for Mounting and Air Flow Display Cutout Front View Leave 25 mm (1 in.) for Mounting and Air Flow Leave 38 mm (1.5 in.) for Mounting and Air Flow Leave 25 mm (1 in.) for Mounting and Air Flow

8 Dataliner DL10 Message Display Cutout Dimensions Figure 3 shows the required cut-out dimensions. Figure 3 Dimensions in Inches (Millimeters) Four Line DL10 Display 0.218 (5.5) DIA. HOLE (6 PLACES) 0.12 (3.0) 6.94 (176.1) 6.81 (173.0) 13.87 (352.3) 13.62 (345.9) Cut Out 5.26 (133.6) Cut Out 5.68 (144.3)

Dataliner DL10 Message Display 9 EMI Power-Line Filters (EU Installations Only) DL10 displays intended for use in the European Union require a power-line filter. One line filter is required for each installed display. Two filter models are available. These filters are functionally identical, they differ only in termination style. Schaffner Part No. FN 660-3/06 FN 660-3/07 Termination Style Fast-On (Spade) connectors Wire leads Line filters are available from an authorized Schaffner distributor. 27mm (1.06 in.) Part Number (FN 660-3/07) 30mm (1.18 in.) 12 mm (0.47 in.) 65 mm (2.56 in.) 85 mm (3.35 in.) 75 mm (2.95 in.) Part Number (FN 660-3/06) 5.3 mm (0.21 in.) 54 mm (2.13 in.) When properly installed, power-line filters prevent interference currents in the power lines. Interference currents can affect other devices on the same power line and other nearby equipment. Connect the Dataliner message display to the power-line filter as shown on the following page.

10 Dataliner DL10 Message Display Connecting AC Power The table below shows the electrical ratings for the Dataliner DL10 display. Catalog Number Supply Voltage Power Consumption 2706-A41C 2706-A41J 2706-A42C 2706-A42J 120V ac, 60 Hz 240V ac, 50 Hz 55 VA maximum 55 VA maximum!!! ATTENTION: Terminal 3 (Protective Earth) must be connected to a reliable low impedance earth ground to protect the display from electrical noise. This ground connection will also protect personnel from electrical shock if the electronics short to the DL10 case. ATTENTION: The Dataliner DL10 display is designed for safe use when installed in a suitably rated NEMA Type 12, 13, 4X (indoor use only), IP54 or IP65 enclosure. ATTENTION: Do not apply power to the display until all wiring connections have been made. Failure to do so may result in electrical shock.

Dataliner DL10 Message Display 11 Wiring Guidelines (EU Installations Only) 10 cm (4 in.) Maximum To Dataliner AC Input L1 L2N L1 L2N To AC Mains Supply For installations within the European Union use the following guidelines to minimize Radio Frequency Interference (RFI) and achieve maximum Electromagnetic Compatibility (EMC). Follow all local safety regulations regarding proper grounding. Output leads from the power-line filter to the Dataliner must be 10 cm (4 in.) or less. Both Dataliner and power-line filter must be connected to a low impedance earth ground. All parts of the grounding system must be connected together with low impedance connections. Keep all ground connections as short as possible. Power-line filter must be connected to earth ground before connecting the power source. Do not run signal wiring and power wiring in the same conduit. When control or communication wires must cross, they should cross at an angle as close to 90 degrees as possible. Follow Dataliner display shielded cable requirements as specified in the user manual. Make sure cable shielding connections and terminations are connected as specified in the appropriate Dataliner User Manual. Keep the filter line side leads well separated from the load side leads.

12 Dataliner DL10 Message Display Wiring Diagram The following diagram shows how to connect the power-line filter for installations within the European Union. For non-european Union installations, the power-line filter can be omitted. For all other wiring connections refer to the DL10 User Manual (Publication 2706-800). L1 240 VAC L2N RS-422 IN OUT + + RS-232 I N O U T G N D 1 2 3 4 5 6 7 8 9 10 11 12 10 cm (4 in.) Maximum L1 LOAD FN 660 LINE FILTER LINE L2N

Dataliner DL10 Message Display 13 Fuse Replacement The four line Series B and later DL10 display has two fuses. To determine if one of the fuses is bad, remove power to the display and then remove the top cover of the display by loosening the three cover screws. Check and replace one or both fuses if necessary. Main Fuse 1.5 Amp, Type MDL, 250V ac FU1 on Auxiliary Power Supply 0.375 Amp, Type MDL, 250V ac. Top View (cover off) Auxiliary Power Supply Board Main Fuse Auxiliary Power Supply Fuse (FU1) Display Front

14 Dataliner DL10 Message Display AC Power Connections Connection 120/240V ac, 3 Wire U.S. Color Code 120/240V ac, 3 Wire European Harmonized Color Code L1 Black (Line) Brown (Line) L2N White (Neutral) Blue (Neutral) P.E. Green (Earth Ground) Green/Yellow (Protective Earth) Additional Information For additional information on communication port wiring and display configuration, refer to the Dataliner DL10 User Manual (Publication 2706-800).

Notes: Dataliner DL10 Message Display 15

Worldwide representation. Argentina Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile China, PRC Colombia Costa Rica Croatia Cyprus Czech Republic Denmark Ecuador Egypt El Salvador Finland France Germany Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Ireland Israel Italy Jamaica Japan Jordan Korea Kuwait Lebanon Malaysia Mexico Netherlands New Zealand Norway Pakistan Peru Philippines Poland Portugal Puerto Rico Qatar Romania Russia CIS Saudi Arabia Singapore Slovakia Slovenia South Africa, Republic Spain Sweden Switzerland Taiwan Thailand Turkey United Arab Emirates United Kingdom United States Uruguay Venezuela Yugoslavia Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 41061-017-01(B) Copyright 1999 Allen-Bradley Company, Inc. Printed in USA