DESCRIPTION RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today s popular ceiling systems and is available with a number of options and accessories for application versatility. The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Catalog # Project Comments Prepared by Metalux Date SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral rid-lock feature for safety and convenience. Controls Metalux LED luminaires come standard with -1V dimming drivers (1% standard). Options compatible with s Connected Lighting Systems: WaveLinx sensor LumaWatt Pro sensor SVPD sensor DLVP sensor and driver Fifth Light DALI driver Other options include stepdimming and 3rd party drivers. Refer to the Connected Lighting options page and ordering information for more details. Electrical Long-Life LED system coupled with electrical driver to deliver optimal performance. LED s available in 3K, 3K or 4K with a minimum CRI of 8. Projected life is 6, hours at 93% lumen output. culus listed. Electronic drivers are available for 12-277V applications. Emergency Battery Pack Option Optional 12V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 9-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/ indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. Emergency/generator transfer options available see ordering information for details. Hinging/Latching Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. Frame/Sheilding Die formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens. Compliance Modules are UL recognized components and indoor luminaires are culus listed for 2ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-8 standards. DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. 24RLN LED 2' X 4' TROFFER LED MODULE Specification rade Troffer Rectilinear Shielding Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 9% reflective white enamel for superior performance. Warranty Five year warranty. RECTILINEAR 3-1/4" [83mm] 23-3/4" [63mm] MOUNTIN DATA DOOR FRAMES CERTIFICATION DATA 23-3/4" [63mm] 47-1/16" [1218mm] RLN Flat, White Steel culus198 Damp Location Listed IC Rated LM79/LM8 Compliant ROHS Compliant DesignLights Consortium Qualified 47-3/4" [1212mm] Safe and convenient means of disconnecting power
24RLN LED RECTILINEAR SHIELDIN CEILIN COMPATIBILITY rid/lay-in Standard Concealed T Slot rid Ceiling Exposed rid Concealed T Slot rid Trim (Verify compatibility/ consult factory.) ENERY AND PERFORMANCE DATA BY CATALO NUMBER Stock or Delivered Efficacy Watts MTO Catalog Logic (Rectilinear Shielding) Lumens (lm/w) MTO 24RLN-LD-31-UNV-L83-CD1-U 32 22.9 133 MTO 24RLN-LD-31-UNV-L83-CD1-U 3179 22.9 139 MTO 24RLN-LD-31-UNV-L84-CD1-U 3179 22.9 139 MTO 24RLN-LD-36-UNV-L83-CD1-U 3 26. 132 MTO 24RLN-LD-36-UNV-L83-CD1-U 361 26. 138 MTO 24RLN-LD-36-UNV-L84-CD1-U 361 26. 138 MTO 24RLN-LD-42-UNV-L83-CD1-U 44 31.2 129 MTO 24RLN-LD-42-UNV-L83-CD1-U 428 31.2 13 MTO 24RLN-LD-42-UNV-L84-CD1-U 428 31.2 13 MTO 24RLN-LD-4-UNV-L83-CD1-U 436 34. 128 STOCK 24RLN-LD-4-UNV-L83-CD1-U 447 34. 134 STOCK 24RLN-LD-4-UNV-L84-CD1-U 447 34. 134 MTO 24RLN-LD--UNV-L83-CD1-U 48 37.8 127 MTO 24RLN-LD--UNV-L83-CD1-U 37.8 132 MTO 24RLN-LD--UNV-L84-CD1-U 37.8 132 MTO 24RLN-LD--UNV-L83-CD1-U 332 42.7 12 STOCK 24RLN-LD--UNV-L83-CD1-U 4 42.7 13 STOCK 24RLN-LD--UNV-L84-CD1-U 4 42.7 13 MTO 24RLN-LD-6-UNV-L83-CD1-U 9 47.7 121 MTO 24RLN-LD-6-UNV-L83-CD1-U 999 47.7 126 MTO 24RLN-LD-6-UNV-L84-CD1-U 999 47.7 126 MTO 24RLN-LD-67-UNV-L83-CD1-U 648 3.9 12 MTO 24RLN-LD-67-UNV-L83-CD1-U 6 3.9 12 MTO 24RLN-LD-67-UNV-L84-CD1-U 6 3.9 12 MTO 24RLN-LD-74-UNV-L83-CD1-U 7136 61.6 116 MTO 24RLN-LD-74-UNV-L83-CD1-U 7433 61.6 121 MTO 24RLN-LD-74-UNV-L84-CD1-U 7433 61.6 121 MTO 24RLN-LD-8-UNV-L83-CD1-U 773 67. 11 MTO 24RLN-LD-8-UNV-L83-CD1-U 87 67. 119 MTO 24RLN-LD-8-UNV-L84-CD1-U 87 67. 119 LUMEN MAINTENANCE Ambient Temperature 9 CRI TM-21 Lumen Maintenance (6, hours) Theoretical L7 (Hours) 2 C > 93% > 31, Lumen Adjustment Factors 8->9 CRI 3K.86 3K.861 4K.883 K n.a. Example of Lumen Adjustment Calculation 24RLN-LD-4-UNV-L93-CD1-U at 9CRI at 3K Lumen Adjustment Factor =.861 Total Light Output = 4,47 lm x.861 = 3,914 lm Efficacy = 3,914 lm = 11.1 lm/w 34 W Peachtree City, A 3269 P: 77-486-48
24RLN LED RECTILINEAR SHIELDIN PHOTOMETRICS 444 888 1332 1776 24RLN-LD-4-UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.2 x mounting height, ( ) 1.21 x mounting height Lumens: 447.1 Input Watts: 34W Efficacy: 133.7 lm/w Test Report: 24RLN-LD-4-UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 8 8 9 1774 1774 1774 1767 1762 1771 1738 1733 1741 1689 1684 1693 1619 1617 1629 134 133 147 1434 1432 1448 1318 1317 1332 1197 1194 124 16 162 169 934 92 929 83 79 788 662 6 646 32 12 42 376 366 278 22 241 166 14 126 67 48 4 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 89 91 89 87 8 1 92 8 8 97 9 84 79 86 81 77 83 79 8 77 73 71 91 81 73 67 89 79 72 66 76 7 6 74 68 64 71 67 63 6 84 72 63 7 81 71 63 6 68 61 6 66 6 64 8 4 2 77 64 6 49 63 49 61 4 48 9 3 48 7 2 47 4 71 8 49 43 69 7 49 43 48 42 4 47 42 2 46 42 4 66 3 44 38 64 2 44 38 43 38 49 42 37 48 42 37 3 62 48 4 34 6 48 4 34 46 39 34 4 38 34 44 38 33 32 8 44 36 31 6 44 36 31 43 36 31 42 3 3 41 3 3 28 4 41 33 28 3 4 33 28 39 33 28 39 32 28 38 32 28 26 42 18 1627 2169 24RLN-LD--UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.2 x mounting height, ( ) 1.21 x mounting height Lumens: 4. Input Watts: 42.7W Efficacy: 13.1 lm/w Test Report: 24RLN-LD--UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 8 8 9 2167 2167 2167 216 211 2162 2124 2117 2129 261 29 267 1979 1977 1989 1871 1872 189 1748 11 1769 1612 161 163 1462 146 1472 134 1298 131 1142 113 114 976 964 962 814 792 783 649 623 613 492 49 44 34 38 289 24 17 16 81 9 48 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 89 91 89 87 8 1 92 8 8 97 9 84 79 86 81 77 83 79 8 77 73 71 91 81 73 67 89 79 72 66 76 7 6 74 68 64 71 67 63 6 84 72 63 7 81 71 63 6 68 61 6 66 6 64 8 4 2 77 64 6 49 63 49 61 4 48 9 3 48 7 2 47 4 71 8 49 43 69 7 49 43 48 42 4 47 42 2 46 42 4 66 3 44 38 64 2 44 38 43 38 49 42 37 48 42 37 3 62 48 4 34 6 48 4 34 46 39 34 4 38 34 44 38 33 32 8 44 36 31 6 44 36 31 43 36 31 42 3 3 41 3 3 28 4 41 33 28 3 4 33 28 39 33 28 39 32 28 38 32 28 26 Zonal Lumen Summary Zone Lumens % Fixture -3 131 29.7-4 2178 47.9-6 37 81. -9 447 1. -18 447 1. Luminance Data Angle in Deg 4 6 8 -Deg 4-Deg 9-Deg 237 23 2316 2144 211 214 1928 186 1812 164 1491 1426 1177 844 73 Zonal Lumen Summary Zone Lumens % Fixture -3 161 29.7-4 266 47.9-6 426 81. -9 4 1. -18 4 1. Luminance Data Angle in Deg 4 6 8 -Deg 4-Deg 9-Deg 282 2812 2838 266 274 269 232 228 2222 212 1823 171 1423 137 844 Peachtree City, A 3269 P: 77-486-48
24RLN LED RECTILINEAR SHIELDIN ORDERIN INFORMATION SAMPLE NUMBER: 24RLN-LD-4-UNV-L83-CD1-U Rating [Blank]= Standard ATW-SW4= Chicago Rated Series () 24RLN=2x4 RLN Series Door Frame Standard=Flat White Steel Door (Leave Blank) Lamp LD=LED. Stock Lumen Output 4=4 Lumen = Lumen MTO Lumen Output 31=31 Lumen 36=36 Lumen 42=42 Lumen = Lumen 6=6 Lumen 67=67 Lumen 74=74 Lumen 8=8 Lumen Shielding Blank=Standard Lens RDP=Rectilinear with Round Pattern Insert Voltage (2) 347V=347 Volt (6) UNV=Universal Voltage 12-277 48V=48 Volt Low-voltage (Class 2) Options Emergency EL7W=7-watt, 12V-277V emergency battery pack installed (3) EL14W=14-watt 12V-277V emergency battery pack installed (3) ELV7W=7-watt, DLVP-compatible low voltage emergency battery pack installed (C) ELV14W=14-watt DLVP-compatible low voltage emergency battery pack installed (C) TR2=Bodine enerator Transfer Relay (7) ETRD=Iota Emergency Transfer Relay with dimming control (7) CCT L83=3K L83=3K L84=4K L93=3K L93=3K L94=4K Flex A3/8-4/18DIM=3/8" Flex with -1V Dimming Leads Multiple other configurations available. See below for details. Driver CD=-1V Dimming Driver (1%-1% Dimming) SR=Sensor-ready Dimming Driver for LWIPD1 option (1%-1% Dimming) (B) LTD=Fifth Light DALI Driver (4), (E) (1%-1% Dimming) Number of Drivers 1=1 Driver 2=2 Drivers LTHD=Fifth Light Dimming Driver (1%-1% Dimming) (E) LV1=DLVP Dimming Driver (%-1% Dimming) (C) SD=Step Dimming Driver (% or 1% Dimming) (4) LH=Lutron HiLume (LDE1 series) 1%-1% EcoSystem Driver with Soft-on Fade to Black dimming (F) L=Lutron Series (LDE-Series) %-1% EcoSystem Driver (F) LU=Lutron HiLume (L3D series) 1%-1% EcoSystem/3-wire Driver (F) Integrated Sensing Systems SWPD1=WaveLinx Wireless Integrated Sensor (A) LWIPD1=LumaWatt Pro Wireless Integrated Sensor (B) LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (B) SLVPD1=DLVP Low-voltage Integrated Sensor (C) SVPD1=-1V Stand-alone Integrated Sensor (D) Packaging U=Unit Pack PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) DF-24-W=2' x 4' Drywall Frame Kit DF1P-C =Decorator Dimmer, -1V SF1P- =Decorator Slide Dimmer, -1V SK-24-WS=Field Install Surface Mount Kit, Shallow SK-24-WT=Field Install Surface Mount Kit, Tall ISHH-1=Programming Remote for Integrated Sensor (D) ISHH-2=Personal Control Remote for Integrated Sensor (D) NOTES: (1) An EQ rid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2) Products also available in non-us voltages and frequencies for international markets. (3) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (1 lm/w x 7=7 lumens). IES-format photometry for luminaire under emergency operation available. (4) 31, 36 Lumen packages not available with Step- Dim (SD) and Fifth Light (LTD) driver option. () DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. (6) 347V versions are not available with emergency options. (7) Used to bypass local control during outage. Must be used in conjunction with UL 18 device (provided by others). TR2 option includes 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 12V or 277V when ordering these devices. Integrated Sensing and Control System Options NOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) Consult LumaWatt Pro system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. Flexible Metal Conduit Options Flex options available for -1V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 9 enclosed FMC connector. Not all options may be combined and installation ratings vary by type. A3/8-4/18DIM series notes: Factory installed dimming option 3/8 flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed -1V +/- control wires. Meets UL 66, 83, 1479, 169, 181, 26. NEC 2.118, 3.22(C), 392, 396, 33, 1, 2, 3, 3, 4,, 18, 2, 3, 64, 72; Federal Specification A-A-944 (formerly J-C-3B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC ; Environmental Air-Handling Space Installation per NEC 3.22(C ). Specifications & Consult your Representative for availability and ordering information. SHIPPIN DATA Catalog No. 24RLN-LD-4 24RLN-LD- Wt. 1 lbs. 1 lbs. Peachtree City, A 3269 P: 77-486-48
LO SET MIN INTERATED SENSOR 24RLN LED RECTILINEAR SHIELDIN The RLN with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RLN delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RLN delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-1). The integrated sensor personal remote (Catalog Number: ISHH-2) provides code compliant manual raise, lower, ON, OFF control. The RLN with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 2 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. 1 Energy Savings Opportunities Light Level (DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level (DU) Unoccupied Level Unoccupied Occupied Unoccupied Occupied Target light level default: lux at 8 ft. Coverage Top View C L 3.3m [1 ft.] Side View m [ ft.] Major Motion m [ ft.] m [ ft.] Reccomended Mounting Height 8 12 ft. Optional Remote Control Raise/ Lower Time Out HI 1 ES 1 2 Occ MAX To Set Output Un Occ 1. Raise, Lower or Press Min.,, Max. 2. To save press SET 3. Select Occ or Un Occ Programming Remote ISHH-1 ISHH-1 Remote Peachtree City, A 3269 P: 77-486-48