U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Similar documents
U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

For installation into ductwork

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

HCD-230 Industrial Control Damper

BR 20b Ball valve. PFA-lined. Application: Versions:

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

VAV TERMINAL BOXES TYPE: BA BT

Zero Leakage Isolation Damper

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Regulation and shut-off damper SPB and SPC

series RVV Variable flow rate controllers

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Drain ball valve BR 21a

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VOLUME CONTROL / REGULATING DAMPERS

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

OPTIVENT Housing HVSA, HVSL

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

AMD-33 Air Measuring Station with VCD-33 Control Damper

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Series HCD Airfoil Control Damper

VAV Terminal Units SDS

Pressure relief dampers

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Motorized Fire Dampers

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

BR 11e Centric Control and Shut-off Butterfly Valve

NAF-Torex butterfly valves DN , Size 3-28, PN 10-40, ANSI Class 150, 300

Rotary Plug Valve BR 23e

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Marine Fire and Gas Dampers

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Series 14b - Type HD

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

INDEX. Chapter1 6. air master. Volume Control Dampers

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

VARYCONTROL VAV Dual Duct Terminal Boxes

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Non Return Damper, Type RK-E20

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Ceiling swirl diffusers

AL/ST AIR GRILLES WITH MOBILE VANES. Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems.

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Thermal Isolation. Break

FSD60/MFSD60 Multi-blade Fire Damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

BR 14p - PSA. High-Performance Control and Shut-off Butterfly Valve. Application:

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Bonded Liner Butterfly Valve Double Flanged Type Series 150

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

GDD - Supply Grille. Halton GDD. Supply Grille

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

AL-Maraj Central A/C Systems Accessories Mfg Co.

Type 1a Globe Control Valve

VOLUME CONTROL DAMPER

SD-1250 and SD-1600 Series Smoke Dampers

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Parts and characteristics

Type NAK. Gas-tight shut-off damper with pneumatic actuator

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

ID-141x 12-Gauge Hat Channel Industrial Damper

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

627 Series Pressure Reducing Regulators

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

CONSTANTFLOW Volume Flow Controllers

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model VCD-20 3V CONTROL DAMPER

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

VCD-23. Flange Options. Size Limitations

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Technical information

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

Pressure control damper ERPA

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Short Face to Face. Bonded Liner Butterfly Valve Mono Flanged Type (Short) Series 120. Document : S120 Revision : 2 Year : 2014

DATASHEET PRODUCT CODE EXAMPLE:

MOTORIZED VOLUME DAMPER

Series 26d Ball Valve

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Transcription:

Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation of U dampers are easy considering their light weight and good mechanical resistance. There are suitable for HVAC commercial applications. CODIFICATION U range Commercial CONSTRUCTION Width U X Y Steel frame 130 mm In option : 110 mm W L Gear wheels Linkage 130 O G S E Frame s width in mm Non classifi ed Class 1 Class 3 Class 4 Aluminium frame 110 mm Thickness 1.0 mm 2.0 mm Material Galvanized steel Z275 In option: Stainless steel AISI 304L - 1.4307, AISI 316L - 1.4404 or painted steel (standard RAL) Aluminium 6060 Bearings None Polyamide PA 6.6 Drilling Flanges Ø10 mm in each angle In option: specifi c drilling 30 mm Undrilled In option: specifi c drilling Control Manual Motorised Square shaft 12mm - length 100mm Lever and manual locking Square shaft 12mm - length 100mm In option : actuator supplied and assembled in factory Linkage Gear wheels (UW type) Linkage (UL type) Opposed blade operation In option: parallel blade operation (linkage version only) Blades Galvanized steel Z275, thickness of 2 x 0.5mm In option: stainless steel AISI 304L - 1.4307, AISI 316L - 1.4404, painted steel (standard RAL) or profi led aluminium Pitch: 100mm Shaft Ø20 1

PERFORMANCES Seals Volume control O type None Antifrost G type Lateral stainless steel seals Top and bottom L shaped profi les Shut-off S type Lateral stainless steel seals Top and bottom L shaped profi les EPDM seals on the blades Airtight E type (aluminum blades only) Lateral stainless steel seals Top and bottom L shaped profi les EPDM seals on the blades Blades airtightness* Non classifi ed Class 1 Class 3 Class 4 Frame s airtightness* Class A In option: class B or class C Acceptable pressure 1 000 Pa (for a length of 1m) Maximum air velocity Operating temperatures *Airtightness classifi cation according to EN 1751 standard. Pressure (Pa) 500 250 100 50 Class 4 ULE 110 - Aluminium DIN 1946 10 m/s From -20 C to +80 C Leakage rate according to EN 1751 standard UWS 130 - Galvanized steel Class 3 Etanchéité suivant la norme EN1751 Class 2 1 2.77 10 100 Leakage rate (l.s -1.m -2 ) Class 1 Class C 2

DIMENSIONS Height H from 200 to 1400 mm with a pitch of 50mm Length L from 200 to 1400 mm with a pitch of 50mm Actual sizes H+10 x L+10 WEIGHT (kg) 130 (or 110) H + 70 H + 10 Flanges 30 200 400 600 800 1200 1400 200 3 5 6 7 8 9 11 400 5 6 8 9 11 13 14 600 6 8 10 12 14 16 18 800 7 10 12 14 17 19 21 9 11 14 17 19 22 25 1200 10 13 16 19 22 25 28 1400 11 15 18 22 25 28 32 L + 70 L + 10 = = L + 30 Ø10 Other dimensions on request. In option: circular fl ange up to Ø1120 H L Weights given for dampers in galvanized steel. A coeffi cient of 0.9 must be applied to the mentionned data for a damper equipped with aluminium blades. 100 H + 30 PRESSURE LOSSES The following pressure losses (Pa) are given according to the blades opening angle (in ) and air velocity (m/s). Damper type UWO equipped with gear wheels,.opposed blade operation. Air velocity (m/s) Opening angle 0 30 60 1 < 5 < 5 40 2 < 5 22 115 4 < 5 70 335 6 < 5 145 680 8 9 230 1070 10 15 345 1530 Opening angle 0 = fully open damper 90 = closed damper 3

DYNAMICS REGENERATION Damper type UWO equipped with gear wheels. Opposed blade operation. Air flow noise Lw in db ( blades openning angle 30 ) Air velocity (m/s) USE LIMITS Fréquency (Hz) 63 125 250 500 2000 4000 8000 Global 2 33.9 38.2 32.4 26.4 25.5 26.8 35.0 39.0 43.6 4 45.8 48.4 46.4 50.2 45.0 39.8 37.7 39.2 54.9 6 58.2 59.0 54.5 54.7 55.7 51.9 48.5 44.5 64.2 8 62.8 66.6 61.3 61.4 62.5 59.4 57.8 51.1 71.0 10 71.8 72.4 67.7 67.3 67.5 65.0 63.1 58.0 77.4 Datas are given for a damper 500 x 500 mm. For different sizes of dampers, you can use the formula below : X = Air fl ow nosie in db S = Damper section in m 2 x + 10 log ( S ) 0.25 They correspond to the difference between the upstream and downstream pressure that dampers of the U range can withstand. Pressure in Pa Blades length in mm Use limit Recommended limit 4

MOTOR TORQUE The following motor torques are given in Nm for a volume control damper type UWO or ULO. A coefficient of 1.3 must be applied to the mentioned data for an G, S or E type damper. Length (mm) 1400 1200 800 600 400 750 500 250 2 4 6 8 10 12 14 P (Pa) Example : P = 500 Pa UWO 130 damper L = mm, H = mm => motor torque = 8 Nm 200 400 600 Motor torque (Nm) 800 1200 1400 Height (mm) 5