SENTRON VL Series Product Specifications

Similar documents
3VT Kompaktleistungsschalter bis 630A

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

3VT2 Molded Case Circuit Breakers up to 250 A

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

3VT1 Molded Case Circuit Breakers up to 160 A

3VU13, 3VU16 Circuit-Breakers

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

3VF3 to 3VF8 Circuit-Breakers

Product Line Overview. The Most Logically Designed Contact Assembly

3VT5 Molded Case Circuit Breakers up to 1600 A

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Protection Equipment. 5/2 Introduction

Siemens AG VT3 Molded Case Circuit Breakers up to 630 A

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

3 - Protection components Motor circuit-breakers

3VT3 Molded Case Circuit Breakers up to 630 A

Protection Equipment

MS General Information Extended Product Type: MS

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

3VT5 Molded Case Circuit Breakers up to 1600 A

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

DMX 3 -I 2500 switch disconnectors

VL Circuit Breaker DG 150A frame

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Control Circuit Protection

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

D509E. Manual Motor - Starters

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX earth leakage DPX 3 -I earth leakage

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Protective Devices: Circuit-Breakers 1 )

Protection components

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

MOULDED CASE CIRCUIT BREAKERS BC160N

Motor Protection Circuit Breakers 3VU13 and 3VU16

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Overcurrent releases - description, specifications, characteristics specifications specifications description...

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

DPX 1600 Electronic release

DPX Magnetic only

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX moulded case circuit breakers

DATA SHEET 3VT3 MCCB ACCESSORIES

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Thermal magnetic and trip-free switches

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Vistop TM isolating switches 63 to 160A

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Air Circuit Breakers

max pole for t=15 ms

Moulded case circuit breakers

DPX Electronic + earth leakage

UMBW-UL489 and UL1077 Listed

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

DPX 630 Electronic release

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Air Circuit Breakers

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Manual Motor Starters. Meta-MEC

Low voltage moulded case circuit breaker EB2

Phone: Fax: Web: -

Motor Starter Protectors

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

cor Long Run Experience

Motor Circuit Breakers C4

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

MOULDED CASE CIRCUIT BREAKERS BC160N

3VT Molded Case Circuit Breakers up to 1600 A

SENTRON Switching and Protection Devices Switch Disconnectors

MCCB Accessories to suit AF

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Technical data for manual motor starters Type MS325

SIRIUS 3RU2 Thermal Overload Relays

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

DRX 250 B/N/H Circuit breaker (not adjustable)

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Molded Case Circuit Breakers

WORKSHOP SPECIFICATIONS

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Transcription:

SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped with factory supplied Nut Keeper Plates for both incoming and outgoing terminals. Customer determines need for termination devices. A = Designates frame only B = Line protection with LI functions C = Line protection LIG functions residual earth for 3 phase 4 wire systems D = Line protection with LIG functions residual earth for 3 phase 3 wire systems E = Line protection with LS functions (instantaneous override) G = Line protection with LSG functions-residual earth for 3 phase 3 wire systems H = Line protection with LSG functions-residual earth for 3 phase 4 wire systems J = Line protection with LIG functions-for earth return systems K = Line protection with LSIG functions for earth return systems ETU TRIP RELEASE 315 12-315 3VL4731 - B 4-0AA0 400-400 3VL4731 - B 4-0AA0 4 = 4 poles A = Line protection with LI functions (N) pole protected B = Line protection with LI functions (N) pole not protected C = Line protection LIG functions residual earth (N) pole not protected D = Line protection with LIG functions residual earth (N) pole protected E = Line protection with LS functions (fixed override) (N) pole not protected F = Line protection with LS functions (fixed override) (N) pole protected G = Line protection with LSG functions (fixed override) (N) pole not protected H = Line protection with LSG functions (fixed override) (N) pole protected LCD TRIP RELEASE 315 12-315 3VL4731 - C - 0AA0 400-400 3VL4740 - C - 0AA0 3 = 3 poles 4 = 4 poles H = Line protection with customer set LI/LS/LSI functions 3 pole only J = Line protection with customer set LI/LS/LSI functions 4 pole only L = Line protection with LSIG functions for 3 phase 3 wire systems M = Line protection with LSIG functions for 3 phase 4 wire systems N = Line protection with LSIG functions for 3 phase 4 wire systems 4 pole only P = Motor / generator protection with LI functions Hand held test kit for electronic trip releases Test kit: (battery powered) for ETU/LCD releases, as well as interface with laptop or PC Cat.no 3VL9000-8AK00 Communications adapter: Allows for testing of ETU/LCD release as well as parameterization of LCD releases by interface with laptop or PC Cat.no 3VL9000-8AM00

VL400 Stand: 1/00 http://www.siemens.de/sentron-vl http://www.siemens.de/energieverteilung Automation and Drives Group Low-Voltage Controls and Distribution P. O. Box 32 40, D-950 Erlangen, Germany Siemens Aktiengesellschaft Subject to change without prior notice 01/00 Order No. E20001-P285-A000-X-0000 Dispostelle 2704/SEK 30191 SEVL.52.9.01 PA Excellence in Automation & Drives: Siemens

SENTRON VL400 Specifications

SENTRON VL Series Product Specifications VL400 Frame 400 s Specifications: Category A IEC 0947-2 EN0947 3-4 Poles 200-400 s, 220/240Vac, 380/415Vac, 90Vac 50-0hz. U i 750Vac U imp 8kV Type U E I CU I CS ICM VL400N 200-400A 220/240~ 5kA 5kA 143kA 380/415~ 45kA 45kA 94.5kA 90~ 20kA ka 42kA VL400H 200-400A 220/240~ 0kA 75kA 220kA 380/415~ 70kA 70kA 143kA 90~ 22kA 12kA 4.2kA VL400L 200-400A 220/240~ 200kA 150kA 440kA 380/415~ 0kA 75kA 220kA 90~ 25kA 12kA 52.5kA CE Marked Calibrations for 50 C ambient Permissible Load for various ambient temperatures close to the circuitbreaker, related to the rated current of the circuitbreaker used for line protection. @ 40 C--0% @ 50 C--0% @ 0 C--93% @ 70 C--8% Catalog Information 200 to 200 3VL4720 - - 0AA0 250 200 to 250 3VL4725 - - 0AA0 315 250 to 315 3VL4731 - - 0AA0 400 315 to 400 3VL4740 - - 0AA0 Endurance 20,000 operations @ 120 per/hour Watts loss (power loss) at maximum rated current I n 3 phase symmetrical load for line protection----175 watts Permissible mounting position 90 0 30 0 30 0 90 0 Reverse feed-- All VL400 frame circuit breakers are suitable for reverse feed applications. Breaker shipping weight 3 pole = 11.9 lbs. / 5.5kg. 4 pole = 15.7lbs. / 7.2kg. Adj. thermal overload 80 to 0% x Adj. short circuit releases I i Short circuit release I i 200 00-2000 250 1200-2500 315 1575-3150 400 2000-4000 Thermal/magnetic circuit-breaker All VL400 circuit-breakers are shipped with factory supplied Nut Keeper Plates for both incoming and outgoing terminals. Customer determines need for termination devices. D = Thermal/magnetic protection---3 poles E = Thermal/magnetic protection---4 poles 3 = 3 poles 4 = 4 poles w/ left pole (N) switching C = Adjustable thermal overload & short-circuit releases (N) pole protected when using with 4 pole (N) pole = 0% protected E = Non-adjustable circuit-breaker = 400A only K = Starter protection only -- = 200A, 250A, 400A 3 pole only J = 4 pole (N) without protection

Internal accessories: 3HS (*) Switch kits: Maximum internal accessory combinations N - pole left 3HS 1AS 2HS/1AS 2HS (1NO +1NC) 2HS (1NO +1NC) + 1AS (1NO) 1AS (1NC +1NO) use 1 switch only Individual Auxiliary switch: 3SB3400-0K (NO contact) 3SB3400-0J (NC contact) + + + + + + + + right 3HS 1AS 2HS / 1AS U< (*) Do not use N - pole is accessories are installed in left pole Catalog Number 3VL9400-2AB00 3VL9400-2AD00 (left pole only) 3VL9400-2AG00 (left pole only) Rated thermal current I th ---Amps Rated making capacity-------amps Shunt trip releases Catalog Number Power Consumption 48-0Vac 3VL9400 01SM00 158 to 200va 1-127Vac 3VL9400-1SR00 13 to 350va 208-277Vac 3VL9400-1ST00 277 to 350va 380-00Vac 3VL9400-1SV00 158 to 237va 12Vdc 3VL9400-1SB00 1 watts 24Vdc 3VL9400-1SC00 1 watts 48-0Vdc 3VL9400-1SJ00 1 to 172 watts 1-127Vdc 3VL9400-1SK00 220 to 254 watts 220-250Vdc 3VL9400-1SQ00 97 to 220 watts Undervoltage releases 1-127Vac 3VL9400-1UG00 4.5va 208Vac 3VL9400-1UM00 4.5va 220-250Vac 3VL9400-1UH00 4.5va 227Vac 3VL9400-1UQ00 4.5va 380-415Vac 3VL9400-1UJ00 4.5va 440-480Vac 3VL9400-1UK00 4.5va 550-52Vac 3VL9400-1UL00 4.5va 00Vac 3VL9400-1UL00 4.5va 12Vdc 3VL9400-1UT00 3.5watts 24Vdc 3VL9400-1UN00 3.5watts 48Vdc 3VL9400-1UP00 3.5watts 0Vdc 3VL9400-1UU00 3.5watts 1-127Vdc 3VL9400-1UR00 3.5watts 220-250Vdc 3VL9400-1US00 3.5watts AC Volts Rated operational voltage 24 48 1 230 Rate operational current 400 3 00 1 (AC-12) (AC-15) DC Volts Rated operational voltage 24 48 1 230 Rate operational current 5 2.5 1 3 1.5 0.7 0.3 (DC-12) (DC-13) External Accessories Rotary Drives Direct drive Standard-------------------------3VL9400-3HA00 Emergency Stop---------------3VL9400-3HC00 Rotary drive extended Standard-------------------------3VL9400-3HF00 Emergency Stop---------------3VL9400-3HG00 Without knob-------------------3vl9400-3he00 Door-coupling rotary operating mechanism kit to be used with operator 3VL9400-3HE00 Standard--------------------------8UC212-1BD22 Emergency Stop---------------8UC222-3BD22 Kit consists of (1) proper handle with masking plate (1) coupling driver for 8mm shaft (1) 8mm extension shaft 300mm long (1) shaft coupling for 8mm shaft Standard or Emergency-stop rotary drive operator auxiliary switch kit(s). Each switch is a change over contact design 1 - leading OFF to ON 3VL9400-3AS 2 - leading OFF to ON 3VL9400-3AT 1 - early-break ON to OFF 3VL9400-3AU 2 - early-break ON to OFF 3VL9400-3AW Changeover switch specifications Rated thermal current l th -----------2A Rated making capacity 2A resistive - 0.5A inductive AC-----------------------------------------pf 0.7 Rated operational voltage---------220vac Rated operational current---------2a Rated making capacity 2A resistive - 0.5A inductive Cyclinder lock kit for field installation: (key removal when circuit-breaker is in the OFF position) Ronis------------------------------3VL9715-8HA00 CES--------------------------------3VL9711-8HA00 Walking-beam interlock mechanism: Fixed mounted circuit-breakers------------- 3VL9400-8LC00 Draw-out/Plug-in mounted--------------------3vl9200-8ld00 Cable interlock system: Kit contains operator plates only for two circuit-breakers------------------------3vl9400-8la00 Recommended 1.0m long cable------------3vl9000-8lh20

External accessories Stored energy operators with cylinder lock installed Voltage Power Power 24 Vdc 3VL9400-3MJ00 < 500 watts 3VL9400-3MK00 < 500 watts 42-48 Vac/Vdc 3VL9400-3ML00 < 500 watts 3VL9400-3MM00 < 500 watts 0 Vac/Vdc 3VL9400-3MS00 < 500 watts 3VL9400-3MT00 < 500 watts 1-127 Vac/Vdc 3VL9400-3MN00 < 500 watts 3VL9400-3MP00 < 500 watts 220-250Vac/ Vdc 3VL9400-3MQ00 < 500 watts 3VL9400-3MR00 < 500 watts Ronis cylinder lock kit for field installation---------------- 3VL9715-8HA00 Front busbar extensions: Rear terminals: requires the use of a Nut Keeper Plate for each pole (round stock) Straight Short length (1 piece) 3VL9400-4RA00 1 piece-----------------------------3vl9400-4ea00 Long length (1 piece) 3VL9400-4RB00 1 set = 3 pieces ------------------3VL9400-4EC30 Kit: (2) short + (1) long (3 pieces) 3VL9400-4RC30 1 set = 4 pieces ------------------3VL9400-4EC40 (2) short + (2) long (4 pieces) 3VL9400-4RF40 Flared (flat terminals) 1 set = 3 pieces ------------------3VL9400-4ED30 Short length (1 piece) 3VL9400-4RK00 1 set = 4 pieces ------------------3VL9400-4ED40 Long length (1 piece) 3VL9400-4RL00 Kit: (2) short + (1) long (3 pieces) 3VL9400-4RM30 (2) short + (2) long (4 pieces) 3VL9400-4RN40 Terminal connectors: Steel wrap around box terminal for VL400 1 piece-------------------------------3vl9400-4tc00 1 set = 3 pieces--------------------3vl9400-4tc30 1 set = 4 pieces--------------------3vl9400-4tc40 Aluminum body box terminal (1 cavity) 1 piece-------------------------------3vl9400-4td00 1 set = 3 pieces--------------------3vl9400-4td30 1 set = 4 pieces--------------------3vl9400-4td40 Aluminum body box terminal (2 cavity) 1 piece----------------------------- 3VL9400-4TF00 1 set = 3 pieces-------------------- 3VL9400-4TF30 1 set = 4 pieces-------------------- 3VL9400-4TF40 Wire range Wire range Wire range solid wire---------------- 2.5 to 70mm 2 stranded with sleeve end--- 2.5 to 70mm 2 flexible bus (w x h) 12 x mm 1 piece solid or stranded wire---------- 50-240mm 2 2 pieces solid or stranded wire---------- 50-120mm 2 Terminal covers: Inter-phase shield 3 pole extended-------------------3vl9400-8ca30 3 pole standard--------------------3vl9400-8cb30 1 piece---------------------------- 3VL900-8CE00 4 pole extended-------------------3vl9400-8ca40 4 pole standard--------------------3vl9400-8cb40 Plug-in socket assembly: Includes base plate, sockets, busbar cover, mounting screws, base interlock, (does not include interphase shields) Rear connected 3 pole 3VL9400-4PA30 RCD load end mounted to 3 pole 3VL9400-4PB00 4 pole 3VL9400-5PA40 RCD load end mounted to 4 pole 3VL9400-4PB40 Front connected 3 pole 3VL9400-4PC30 RCD load end mounted to 3 pole 3VL9400-4PD30 4 pole 3VL9400-4PA40 RCD load end mounted to 4 pole 3VL9400-4PD40 Plug-in socket for accessory voltage supply each plug-in socket contains 8 positions --maximum of 3 sockets can be used with the VL400 Catalog no. 3VL9400-4PJ00 Draw-out assembly: Includes base plate, sockets, crank handle, baseinterlock, necessary shields Rear connected 3 pole 3VL9400-4WA30 RCD load end mounted to 3 pole 3VL9400-4WB30 4 pole 3VL9400-4WA40 RCD load end mounted to 4 pole 3VL9400-4WB40 Front connected 3 pole 3VL9400-4WC00 RCD load end mounted to 3 pole 3VL9400-4WD30 4 pole 3VL9400-4WC40 RCD load end mounted to 4 pole 3VL9400-4WD40 Position signaling switch to indicate connected or unconnected position of plugin or draw-out assembly. Kit consist of 1 change over switch. Each base can accept up to 2 switches. Catalog no. 3VL9000-4WL00 Handle padlocking device: Mounting screw kit Catalog no. 3VL9400-3HL00 4 screws 3VL9500-8SA40