v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18

Similar documents
Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Installation Guide(s)

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

ELR Series Multi-Point Lock Installation Instructions

Installation Instructions RF4510-EA

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

IN100. with Aperio Technology. Mortise Lock Installation Instructions

Mortise Lockset IN100 with Aperio Technology Installation Instructions

Installation & Programming Guide

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

IN100. with Aperio Technology. Mortise Lock Installation Instructions A8190B 07/16

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

PASSPORT Cylindrical Lock Installation Instructions A8013H 04/16

IN120 WiFi. Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16

Motorized Electric Latch Retraction

V-D2425 and V-D2440 Digital Clock

PASSPORT Mortise Lock. Installation Instructions A8032G 04/16

1500 Series and 1600 Series Electric Strikes Installation Instructions

LED Recessed Troffer Retrofit Kit

Keypad (KP) Series. Standalone Access Control Products

1331 Series. Door Closers

P

Hendrickson Fit Adapter Installation Instructions

1500 Series and 1600 Series Electric Strikes Installation Instructions

20 Series. Exit Device

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

Table Of Contents. 30 Series Exit Device. On The Cover

Installer Guide smart connect

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

IN100. with Aperio Technology. Cylindrical Lock Installation Instructions A8189B 07/16

Electric Strikes for Adams Rite Deadlatches and Cylindrical Locks

TCPWI1/TCPIP1. Attention Installer

Automated Coupled Roller Shade Instruction Manual. link. Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount

422 Series. Cam Action Door Closer

Table of Contents 20 Series Exit Device

Auto-Lift Operating System

V9961 V9961

Learn & Discover Driver TM

Paxton. ins us. Paxlock US

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

268, 269 & 278. Concealed Door Closers

R

E-Plex 5700 Series E-PLEX

X0056. fisher-price.com

1130 Series. Door Closers. SARGENT Manufacturing Company 2004, 2007 All rights reserved


2010 Product Line Catalog

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

Smart Door Lock. Manufacturer's Installation Guide

PASSPORT Cylindrical Lock. Installation Instructions A8033G 04/16

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

5600 Series Power Operator Installation and Instruction Manual


Y9854. fisher-price.com

RETRO SOLUTIONS PRODUCT CATALOG

Press the buttons for fun sounds and music! fisher-price.com

ANSI/BHMA CODE. PRODUCT OPTIONS DEDUCT ADD LESS CYLINDER: Specify "x LC" Cylinder rings/collars not furnished with locksets ordered less cylinders.

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

integra trim ltd. Holiday Home: EASTER/SPRING Try Me Hang Tag - Children s Product I Play or I Sing Goes Here Name of Song TRY ME! Product Name 2 in.

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

J5242.

INSTALLATION INSTRUCTIONS

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

TRAC-Station BT Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

BFK51 CFD40 CHM41. fisher-price.com

XM Series. Quick Start Guide. Technology at Work XMCom9

Radio-Control Raceway

Select II Portable Braking System

Table of Contents Auxiliary Locks

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand

T

CK4400 Series. Standard Duty Cylindrical Knob Locksets

Solar Powered Wireless Temperature Station & Sensor

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US

RETRO SOLUTIONS PRODUCT CATALOG

Bear s Baby Laptop TM

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Quantity Keyset Cylinder Length Cam Keyway Finish 50 AA A01 CRA1 626

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG


9700/F9700 SERIES RIM EXIT DEVICE

Installation & Programming Manual. Quick Reference

CL3300 Series. Cylindrical Lockset Parts Manual

Product features and decoration may vary from the photograph above.

W

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Touchstone TB130 DC Output UPS

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Operation. Smooth. ML2000 Series Mortise Lock

CLASSIC II Portable Braking System

Transcription:

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18 Copyright 2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

1 2 3 4 5 6 7 8 9 Table of Contents Warning...3 General Description...4 Specifications...4 Features...4 Parts Breakdown...5 Installation Instructions...7 RF Technology Lock...15 Hardwire Wiring Options...16 Operational Check...21 1 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced TV technician for help This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme avec la norme NMB-003 du Canada.!! To comply with Fire Listed doors, the batteries must be replaced with alkaline batteries only. Do not install batteries if controller is powered by external power supply. Warning SARGENT Mfg. Co. locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. 1-800-810-WIRE www.sargentlock.com A7885C

2 General Description The SARGENT Profile v.g1.5/lk Mortise Lock is designed for areas which require stand alone authorized entry. It is a self-contained microprocessor-controlled keypad with non-volatile memory. The keypad holds a total of 100 (LK)/2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) different user codes. User codes 01 and 02 are utilized for Master and Supervisory Codes, respectively. SARGENT mortise locks are designed with quality components to provide high security, performance and durability. The Profile v.g1.5 Series provides enhanced software and hardware features. New v.g1.5 controllers replace v.g1 controllers. Product is still ordered as G1- prefix. Controllers are labeled G1.5. This product is operated by six (6) AA alkaline batteries. 3 Specifications Latch - Stainless steel Deadbolt - Stainless steel Guardbolt - Stainless steel, non handed Handed - Easily field reversible without disassembling the lock body Case - 12 gauge heavy duty wrought steel Outside lever controlled by any combination of keypad, proximity or RF technology Inside lever retracts latch and deadbolt Locks furnished for 1-3/4 doors. Can be furnished for other door sizes upon request.(consult factory) U.L. Listed 4 Features Non-volatile memory Motor driven, battery operated Battery operated with 6 AA Alkaline Low battery alert: 4 chirps after code entry External remote request to enter Master, Emergency or Supervisory code will unlock door when low battery has expired 100 (LK) or 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users Programming done at keypad or with a DTD (Data Transfer Device) using SoloPlus software and a Laptop/PC (G1-TA and G1-TP require software) SoloPlus works with PalmPilot; SofLink Plus software not supported with DTD. RF Fob and Proximity Card, Tag, and Fob are optional Operates utilizing any one to six digit code Digits may be repeated and codes may start with zero Cylinder override Entry of three wrong User Codes disables all codes for ten seconds. Yellow LED on solid Piezo horn can be heard with each keystroke or turned off by Master or Supervisory Code Last 15 transactions can be output to portable print via infrared link (LK Only) Last 2000 (Except LK) transactions can be output to PC via DTD/SoloPlus Software 4 1-800-810-WIRE www.sargentlock.com A7855D

5 Parts Breakdown 35 12 32 13 13 3 34 33 22 22 21 26 24 24 16 17 1 30 11 11 4 4 5 5 7 16 16 17 11 11 20 29 1727/28 20 2 8 9 15 15 14 31 Inside 23 24 24 25 21 22 26 18 18/1919 20 20 20 Outside 1-800-810-WIRE www.sargentlock.com A7855D 5

Parts Breakdown (Continued) ITEM PART No. DESCRIPTION REQ D ITEM PART No. DESCRIPTION REQ D 1 82-4190 Outside Escutcheon with Cylinder Hole and Key Pad, or Key 1 Pad/Prox (G1-LU, G1-PK, G1-TU, G1-TP) 82-4191 Outside Escutcheon without Cylinder Hole and Key Pad or Key 1 Pad/Prox (G1-LU, G1-PK, G1-TU, G1-TP) 82-4192 Outside Escutcheon with Cylinder Hole and Prox Only (G1-PA, 1 G1-TA) 82-4193 Outside Escutcheon without Cylinder Hole and Prox Only (G1-1 PA, G1-TA) 82-0493 Outside Escutcheon Housing Only without Cylinder Hole 1 82-0495 Outside Escutcheon Housing Only with Cylinder Hole 1 52-2432 Keypad/Proximity Bezel Assembly w/ Harness (LK) 1 52-2706 Proximity Only Bezel Assembly with Harness (G1-PA, G1-TA) 1 52-2704 Key Pad/Proximity Bezel Assembly with Harness (G1-LU, G1-PK, 1 G1-TU, G1-TP) 2 82-3837 Inside Escutcheon with Thumb Turn and 100 User Controller (LK) 1 82-3838 Inside Escutcheon without Thumb Turn and 100 User Controller 1 (LK) 82-4182 Inside Escutcheon with Thumb Turn and 2000 User Controller 1 (G1-LU) 82-4183 Inside Escutcheon without Thumb Turn and 2000 User Controller 1 (G1-LU) 82-4184 Inside Escutcheon with Thumb Turn Prox/Key Pad Controller (G1-PA, G1-PK) 1 82-4185 Inside Escutcheon without Thumb Turn Prox/Key Pad Cont. 1 (G1-PA, G1-PK) 82-4186 Inside Escutcheon with Thumb Turn & 2000 User Controller with 1 RF Technology (G1-TU) 82-4187 Inside Escutcheon without Thumb Turn & 2000 User Controller 1 with RF Technology (G1-TU) 82-4188 Inside Escutcheon with Thumb Turn & Keypad/Prox or Prox Only 1 Controller (G1-TA, G1-TP) 82-4189 Inside Escutcheon without Thumb Turn & Keypad Prox or Prox 1 Only Controller (G1-TA, G1-TP) 82-0492 Inside Escutcheon Housing Only without Thumb Turn 1 82-0494 Inside Escutcheon Housing Only with Thumb Turn 1 52-2440 100 (LK) User Key Pad Controller Assembly 1 52-2783 2000 (G1-LU) User Controller Assembly 1 52-2784 2000 User (G1-PA, G1-PK) Controller Assembly 1 52-2786 2000 User Keypad/Prox Controller Assembly with RF Technology 1 (G1-TA, G1-TP) 52-2785 2000 User Keypad Controller Assembly with RF Technology 1 (G1-TU) 3 52-0170 Battery Cover 1 52-2509 Battery Cover RF Technology (G1-TU,G1-TP, G1-TA) 1 4 01-1212 Security Screw 1 5 01-0297 Security Tool 1 7 82-0507 Thumb Turn 1 8 77-0772 Spindle (Thumb Turn) 1 9 01-0844 Washer (Thumb Turn) 1 10 01-0543 Spring Grip Fastener (Thumb Turn) 1 11 77-0168 Through-bolts #8-32 x 1 7/8 Flat Head Screw 2 12 52-0033 Fire Stop Plate 1 13 01-1500 Fire Stop Screws #8 x 1/2 Type AB Phillips Pan Head Self Tap 14 82-3088 Inside Spindle Adapter & Plate Assembly 1 15 01-1495 Screw #8-32 x 1/2 2 16 82-0368 Inside Spindle/Outside Spindle 2 17 82-0347 Inside Spring/Outside Spring 2 18 82-0081 Face Plate no Dead Bolt 1 19 82-0084 Face Plate with Dead Bolt 1 20 01-1028 Face Plate Screws Machine 8-32 x 1/4 2 21 01-2299 Lock Body Screws/Wood Door #12 x 1 1/4 2 22 01-1019 Lock Body Screws/Metal Door 12-24 x 1/2 2 23 82-0184 Cap Nut 1 24 01-0079 Washer 2 25 82-3082 Plate Assembly 1 26 81-0723 Post 2 27 01-1472 Lever Handle Screw, A, E & F Lever 1 28 01-1174 Lever Handle Screw, B, J, L, P & W Lever 1 29 Reference Profile Series catalog for available lever handles 30 Reference Profile Series catalog for available lever handles 31 825155 & 825095 Lockbody Assembly with deadbolt & cylinder 1 825155 & 825095 Lockbody Assembly with deadbolt only (no cylinder) 1 1 825154 & 825095 Lockbody Assembly with cylinder only (no deadbolt) 1 825154 & 825095 Lockbody Assembly without deadbolt & without cylinder 32 01-0803 Battery Alkaline ( AA cell - not shown) 6 33 52-0253 Battery Keeper 1 52-0344 Battery Keeper RF Technology (G1-TU, G1-TP, G1-TA) 1 34 10-0649 Gasket, weatherseal 1 2 6 1-800-810-WIRE www.sargentlock.com A7855D

6 Installation Instructions Step #1 Verify Hand and Bevel of Door A. Verify Hand and Bevel of Door Stand on outside/locked side of door when determining the door hand LH Left Hand Hinges Left Open Inward LHRB Left Hand Reverse Bevel Hinges Left Open Outward RH Right Hand Hinges Right Open Inward RHRB Right Hand Reverse Bevel Hinges Right Open Outward B. Prepare Door Fig. 1A Prep door according to Instruction Sheet A7454 and appropriate template: Manufacturer Door Template: 4533 Ribbon Cable Hole (Controller to Keypad) Inside Cylinder Hole Thumb Turn Lever Hole Lever Handle Hole Inside of Door Mortised Pocket Pre-drilled and/or Tapped Holes (2 places) Fig. 1B Wood Door Preparation Outside of Door Through-bolt Hole Outside Cylinder Hole (76 and 78 Functions) Lever Handle Hole Through-bolt Hole 1-800-810-WIRE www.sargentlock.com A7855D 7

Step #2 How to Change Hand of Lockbody A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A): 1. Position lock body with red surface of locking piece visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body. 3. Rotate the locking piece 180 until RED surface is on opposite side. Note: Red indicates locked side (outside). Locking Slide Red on Locked Side Right Hand Lock Shown Fig. 2A Push In B. Reverse Latch Hand Beveled surface of latchbolt must face strike (Fig. 2B). The deadlatch is self adjusting. To change the hand of the latchbolt: 1. Insert the blade of a slotted screwdriver (>1/4 ) into the spade shape slot behind latch. 2. Rotate the screwdriver 90 to push latchbolt out until back of bolt clears lock case front. 3. Rotate latchbolt 180 until the latchbolt drops back into the lock body. Note: Latch cannot be unscrewed. Spade Shaped Slot Fig. 2B Latchbolt Deadlatch 8 1-800-810-WIRE www.sargentlock.com A7855D

Step #3 Install Lock Body 1. Insert lock body into mortised cutout (Fig. 3A). 2. Hold lock body loosely in place with (2) lock body screws. Note: Do not completely tighten screws at this time. Non-Cylinder Side Harness exits Non-Cylinder side (2) #12-24 x 1/2 Flat Head Screws (Metal Doors) (2) #12 x 1-1/4 Flat Head Screws (Metal Doors) Fig. 3A Step #4 Exterior Door Options A. Fire Stop Plate (P/N 53-0033) Fire-rated doors require a fire stop plate on the outside of the door (Fig. 4A). 1. Drill (2) 1/8 x 1-1/4 deep holes in the door if not already present. Refer to template for fire-stop prep locations. 2. Attach with flap up and out using (2) #8 x 1/2 self-tapping screws for wood and metal doors. B. Weather Conduit (P/N 52-2847) Install weather conduit on NON FIRE-RATED exterior doors only. 1. Carefully insert the weather conduit into the ribbon cable hole on the inside of the door (Fig. 4B). 2. Place the O-ring around the weather conduit on the outside and up against the door (Fig. 4C). of 1-1/2 Diameter 1-1/2 7/8 Fig. 4A (2) 1/8 Diameter Holes Required Slot Fire Stop Plate (2) Self Tapping Screws #8 x 1/2 for Wood and Metal Doors Outside of Door Fig.4B Ribbon Cable Hole O-Ring Fig.4C Outside of Door 1-800-810-WIRE www.sargentlock.com A7855D 9

Step #5 Install Weatherseal Gasket (Exterior Doors) 1. Carefully remove the backing from the gasket. 2. Apply gasket to escutcheon: Starting in one place, press the adhesive side of the gasket firmly against the escutcheon. Work around the escutcheon, pressing the sticky side of the gasket firmly against the escutcheon edge. The gasket should be aligned so that all edges of the escutcheon are covered. 3. Attach escutcheon to the door. Note: The 43 cylinder may be used with or without a gasket. Fig. 5A Step #6 Install Outside Escutcheon and Lever Assembly 1A. For 12- fire rated doors: Feed ribbon cable with connector and ground wire from outside of door through weather seal gasket and fire stop plate (Fig. 6A). Note: Install ribbon cable with cable exiting down 1B. For non-12- fire rated doors: Feed ribbon cable with connector and ground wire from outside of door through weather seal gasket (if used) and weather conduit (not shown). Note: Install ribbon cable with cable exiting down, orienting with side marked TOP facing up. 2. With outside lever horizontal, locate the outside escutcheon on the door, while directing the mounting posts through the door and lock body (Fig. 6B). 3. Make certain the lever spindle is properly engaged in lock. 4. On the inside of the door, insert spindle into square hole of mortise lock. 5. Slide inside adapter and plate assembly over spindle and loosely secure with 2 through bolt screws (#8-32 x 5/8 ). Note: For 8276 and 8278, loosely thread cylinder through escutcheon and into the lock body before tightening the lock case screws and escutcheon through-bolts. Inside of Door Mortise Lock Body Connector and Wire Fig. 5B Keypad Ribbon Cable Connector TOP Ground Wire Outside of Door Fig. 6A 10 1-800-810-WIRE www.sargentlock.com A7855D Fig. 6B

Step #7 Inside Escutcheon Wire Connections Images are shown without gasket. If gasket is necessary, refer to Step #5. Before the controller is attached to the door: 1. Attach the reader assembly ribbon cable into the back of the controller assembly (side that faces towards the door when mounted (Fig. 7A). 2. Attach the ground wire to the bottom of the controller assembly (E1, Fig. 7A). 3. Connect the cable from the cylindrical lock to the bottom of the controller assembly (TB1, Fig. 7B). If Hardwiring is required, go to Hardwire Wiring Options on page 14. 4. Place extra wire inside door hole and/or outside escutcheon, being careful not to pinch wires. Connectors go on only one way. Do not offset connectors, and make sure they are completely seated. With Deadbolt Lock Body Wire Harness Without Deadbolt Lock Body Wire Harness 1 Outside Escutcheon 2 Ground Wire Reader Cable Black TB1 Red 1 Ground Wire TB1 3 Red Black Green Green Ground Motor Connector TB1 Reader Ribbon Cable Lock Cable 3 Fig. 7B Fig. 7A Inside of Door Remote Power REX Connector TB1 3 2 Inside Escutcheon (Back) 1-800-810-WIRE www.sargentlock.com A7855D 11

Step #8 Inside Lever Installation 1. Slide lever handle onto spindle until fully seated (Fig. 8A). 2. Insert #8-32 x 1-1/4 screws through inside escutcheon and thread into outside escutcheon. 3. Straighten escutcheons and tighten securely. 4. Tighten the set screw securely with 1/8 hex wrench. Inside of Door Fig. 8A Spindle Set Screw Step #9 Install and Secure Cylinder 1. Slide cylinder through the spring and rosette/collar and screw into lock body, rotating the cylinder clockwise (Fig. 9A). Cylinder should be flush with rosette/collar. Note: The 43 cylinder may be used when installing this product with or without a gasket. Note: SARGENT logo must be horizontal and on the top of the cylinder (Fig. 9B). 2. Secure the cylinder by tightening cylinder clamp screw located above the deadbolt using #2 Phillips screwdriver (Fig. 9C). 3. Using the key, test cylinder functions: 8278 Function: Key retracts latch 8276 Function: Key retracts latch and projects and retracts deadbolt Outside of Door Cylinder Clamp Screw #2 Phillips Screwdriver 12 1-800-810-WIRE www.sargentlock.com A7855D Fig. 9C Position cylinder so that the SARGENT logo is right-side up. Correct Fig. 9A Fig. 9B Outside of Door Incorrect Type 43 Cylinder Inside Lever Key

Step #10 Attach Front Plate Outside of Door Attach front plate with (2) flat head screws. Front Plate (2) Flat Head Screws Fig. 10A Lock Body Screws Step #11 Attach Battery Keeper and Cover 1. Secure the inside escutcheon using two #8-32 screws through top and bottom of the escutcheon (Fig. 11A). Thread into outside escutcheon. Note: For RF Technology versions (G1-TU, G1-TP, G1-TA), refer to RF Technology Lock section on page 14 to install through-bolt screws. 2. Straighten escutcheons and tighten securely, being careful to avoid pinching wires. 3. Attach inside cover to escutcheon making sure to line up tabs with retaining slots in cover. 4. Secure with security screw using security tool (P/N 01-0297) provided (Fig. 11A). Security Tool 01-0297 (Included) Battery Cover Security Screw Fig. 11A Battery Keeper #8-32 Screws Inside of door #8-32 Screws 1-800-810-WIRE www.sargentlock.com A7855D 13

Step #12 Install and Remove Batteries* A. Install Batteries and Keeper 1. Place (6) AA batteries into the compartment, being careful to properly align polarity (Fig. 12A). 2. To install battery keeper, insert the tabs on the bottom of the keeper into the battery compartment slots and press the keeper tightly against batteries and inserting tabs into bottom slots. For RF technology, use RF Technology lock information RF Technology Lock on page 14. IMPORTANT: * Do not install batteries if controller is powered by external power supply. Test for proper operation before closing door. B. Remove Battery Keeper To remove the battery keeper, pull the keeper away from the batteries (Fig. 12B). + - + + - + Tip Out Battery Keeper Bottom Tabs (Battery Keeper) Fig. 12A Step #13 Install Inside Cover 1. Attach inside cover to escutcheon making sure to line up tabs with retaining slots in cover. 2. Secure with security screw using provided security tool Fig. 13A). Tabs Keeper Tabs Fig. 12B Retaining Slots Fig. 13A 14 1-800-810-WIRE www.sargentlock.com A7855D

7 RF Technology Lock Installation for the RF Technology Lock for G1-TU, G1-TA, G1-TP is, for the most part, installed as described in section 6. In addition: The antenna board must be carefully moved to access the upper through-bolt screw. Care should be taken to prevent damage to the antenna retaining tabs during this process (Fig. 7A). 1. Press the two tabs away from the antenna board and lift the board off the mounting posts. 2. Insert the flat head through-bolt and secure the escutcheon in place. 3. After tightening the top through-bolt, replace the antenna board by placing it on the mounting posts and pressing into the retaining tabs. Antenna Board Mounting Posts Flathead Through-bolt Fig. 7A Antenna Board Antenna Board Retaining Tabs Controller Assembly 1-800-810-WIRE www.sargentlock.com A7855D 15

8 Wiring Options Hardwiring options include one or a combination of Forced/Propped Door, Hard Power and/or Remote Unlock (REX). Refer to the examples on the following pages: 1. Forced/Propped Door Option (DM-). 2. Hard Power and Remote Unlock (91-). 3. Hard Power and Remote Unlock (-91), with Forced Propped Door (DM-). Important 1. Caution: Disconnect all input power before beginning installation to prevent electrical shock and equipment damage. 2. Installer must be a trained, experienced service person. 3. All wiring must comply with applicable local electrical codes, ordinances and regulations. Installation Notes 1. With new applications, an ElectroLynx door harness with 8 and 4 pin connectors will be pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process. 2. Wiring to pigtail harness is per facility wiring requirement. ElectroLynx connector terminations and wire colors all match. 3. If door does not have an ElectroLynx type door harness, cut connectors off product and hard-wire, or consult factory for appropriate mating harness. ElectroLynx Connector System Notes The system is designed to be installation friendly with connectors from the electric hinge through the door to the rail. The only wiring required is to the loose wires on the pigtail harness assembly on the frame side of the electric hinge. IMPORTANT: The plug and receptacle connectors are designed to mate and lock together as shown in the figure. Plug the connectors into each other with the locking mechanism aligned as indicated. Do NOT force connectors on any other way. Receptacle ElectroLynx As part of their promise to provide innovative, fast and effective, and higher security solutions to their customers, ASSA ABLOY Group companies offer ElectroLynx, a universal quick-connect system that simplifies the electrification of the door opening. ElectroLynx is a registered trademark of ASSA ABLOY, Inc. Locking Mechanism Plug 16 1-800-810-WIRE www.sargentlock.com A7855D

A ElectroLynx Lock Wire Connections Door Position Switch (DPS) Install the SARGENT 3287 Door Status Switch according to instructions included in the kit. Wire the 3287 Door Status Switch to the ElectroLynx frame harness and to the door status wires: 1. Connect the common wire of the switch to the common wire of the harness. 2. Connect the normally open wire of the switch to the door position wire of the harness. Note: The third wire (normally closed) of the 3287 Door Status Switch is not used for this type of system. Before the controller is attached to the door (Fig. 1A): 1. Attach the reader cable to the controller. 2. Attach the connector from the lock into the bottom of the circuit board (TB2, Fig. 3B). 3. Plug the ground wire into the bottom of the controller assembly (E1, Fig. 3B). Fig. 1 4. Route the connector from the raceway through the top opening between the controller and the escutcheon, along the battery keeper, back under the bottom opening between the controller and escutcheon and attach at the bottom of the controller. Note: Connectors go on only one way. Do not offset connectors and make sure they are completely seated. C B A D Inside Escutcheon (Front) 1 2 4 2 1 3 4 Inside Escutcheon (Back) Fig. 1A 4 Inside of Door 1-800-810-WIRE www.sargentlock.com A7855D 17

Option #1 Forced / Propped Door (DM-) Installation 1. ElectroLynx System Wiring Instructions (Fig. 1, 1A and Fig. 2): a. Look for the mating part on ASSA ABLOY doors and frames. b. Plug in all connectors during product installation (Fig. 2). c. Hard wire door status switch as shown 2. Non-ElectroLynx System Wiring Instructions (Fig. 1 and Fig. 2): a. Cut the 4-pin connector off the Forced/Propped harness and hard wire to non-electrolynx two conductor door harness. b. DM- requires two conductors. c. Hard wire door harness to power transfer device. d. Hard wire door status switch to power transfer device. D Door Inside Escutcheon (TB1) Motor Connector (TB2) Remote/Power Unlock Connector B A D Door Status Switch *Wire for switch contact closure when door is opened - Typical locations shown in Fig. 1 C 1 - Red 2 - Black 3 - White 4 - Green Fig. 1 C A 1 - Red 2 - Black 3 - White (C) 4 - Green (*NC) Outside Escutcheon QC4A Electric Hinge With 4-pin connectors and pigtail harness Fig. 2 Forced/Propped Door Option ElectroLynx Wiring System B 4-pin Connector Ground Tab E3 Forced/Propped Door Connector J4 4 - Tan 3 - Pink 321 DM- Prefix (52-3409) Forced/Propped Door Harness ElectroLynx Door Harness With 8 and 4-pin connectors (Harness location dependent on door type) 18 1-800-810-WIRE www.sargentlock.com A7855D

Option #2 Remote Power and Remote Unlock (91-) C B A D Installation 1. ElectroLynx System Wiring Instructions (Fig. 1, 1A and Fig. 3): a. Look for the mating part on ASSA ABLOY doors and frames. b. Plug in all connectors during product installation (Fig. 3). c. Hard wire hard power and/or remote unlock (REX) (Fig. 3). 2. Non-ElectroLynx System Wiring Instructions (Fig. 1 and Fig. 3): a. Cut the 8-pin connector off the Remote Power/Unlock harness and hard wire to non-electrolynx door harness. b. Remote power requires three conductors and remote unlock requires two conductors. c. Hard wire door harness to power transfer device. d. Hard wire door status switch to power transfer device. *IMPORTANT: (6) AA batteries MUST be removed from controller when using 3267 power supply. Fig. 1 Door * Inside Escutcheon Note: Refer Supply to 3267 Power Instruction Sheet A7477 120VAC L/N/G * 3267 9VDC Power Supply Normally Open Momentary Switch (Remote Unlock REX Option) -9VDC +9VDC EGND 1 - Black 2 - Red 3 - White (NO) 4 - Green 5 - Orange (C) 6 - Blue 7 - Brown 8 - Yellow Outside Escutcheon 1 - Black 2 - Red 3 - White (NO) 4 - Green 5 - Orange (C) 6 - Blue 7 - Brown 8 - Yellow C A (TB1) Motor Connector Ground Tab E3 (TB2) Remote/Power Unlock Connector Fig. 3A Remote Powering and Remote Unlocking ElectroLynx Wiring System QC4A Electric Hinge With 8-pin connectors, 8 wires and pigtail harness B +9V (-) REX REX Data Out Data In RTS EGND 1 2 3 4 5 6 7 8 1 - Red 2 - Black 3 - White 4 - Orange 5 - Blue 6 - Brown 7 - Yellow 8 - Green 91-Prefix (52-3010) Remote Power and Unlocking Harness ElectroLynx Door Harness With 8 and 4-pin connectors - Harness location is dependent on door type 1-800-810-WIRE www.sargentlock.com A7855D 19

Option #3 Hard Power/Remote Unlock (91-) Combined With Forced/Propped Door (DM-) Installation C B Fig. 1 A D 1. ElectroLynx System Wiring Instructions (Fig. 1, 1A and Fig. 3): a. Look for the mating part on ASSA ABLOY doors and frames. b. Plug in all connectors during product installation (Fig. 3). c. Hard wire hard power and/or remote unlock (REX) (Fig. 3). 2. Non-ElectroLynx System Wiring Instructions (Fig. 1 and Fig. 3): a. Cut the 8 and 4-pin connectors off the Remote Power/Unlock harness and hard wire to non-electrolynx door harness. b. Remote power requires three conductors; and remote unlock and DM- require two conductors. c. Hard wire door harness to power transfer device. d. Hard wire door status switch to power transfer device. *IMPORTANT: (6) AA batteries MUST be removed from controller when using 3267 power supply. Door * Inside Escutcheon 120VAC L/N/G * 3267 9VDC Power Supply Note: Refer Supply to 3267 Power Instruction Sheet A7477 Normally Open Momentary Switch (Remote Unlock REX Option) D 1 - Black 2 - Red 3 - White (NO) 4 - Green 5 - Orange (C) 6 - Blue 7 - Brown 8 - Yellow -9VDC +9VDC EGND Door Status Switch *Wire for switch contact closure when door is opened - Typical locations shown in Fig. 1 Outside Escutcheon 1 - Black 2 - Red 3 - White (NO) 4 - Green 5 - Orange (C) 6 - Blue 7 - Brown 8 - Yellow 1 - Red 2 - Black 3 - White (C) 4 - Green (*NC) 20 1-800-810-WIRE www.sargentlock.com A7855D C A (TB1) Motor Connector Ground Tab E3 (TB2) Remote/Power Unlock Connector Fig. 3A Remote Powering and Remote Unlocking ElectroLynx Wiring System QC4A Electric Hinge With 8-pin connectors, 8 wires and pigtail harness B +9V (-) REX REX Data Out Data In RTS EGND 1 2 3 4 5 6 7 8 1 - Red 2 - Black 3 - White 4 - Orange 5 - Blue 6 - Brown 7 - Yellow 8 - Green 4 - Tan 3 - Pink 1 - Red 2 - Black 3 - White 4 - Green 321 ElectroLynx Door Harness With 8 and 4-pin connectors - Harness location is dependent on door type

9 Operational Check For devices with cylinders, insert key into cylinder and rotate. Check to see if: 1. The key retracts the latch. Key should rotate freely. Key should extend and retract the deadbolt (if applicable). 2. The inside lever retracts latchbolt. Thumbturn should extend and retract the deadbolt (if applicable). 3. Enter 1234* to unlock outside lever handle and retract latch and deadbolt if provided). Note: If the lock is prox only (G1-PA) or RF Technology with Prox (G1-TA), refer to keypad programming instruction manual A7857. ~½ 1-800-810-WIRE www.sargentlock.com A7855D 21

Profile Series v.s2 WiFi Mortise Lock Notes 22 A7786F

SARGENT Manufacturing Company 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) www.sargentlock.com Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company s customer base includes commercial construction, institutional, and industrial markets. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A7855D-04/18