HELIOMOTION QUICK ASSEMBLY GUIDE PV-1300

Similar documents
HELIOMOTION QUICK ASSEMBLY GUIDE PV-650

HELIOMOTION QUICK ASSEMBLY GUIDE PV-3

HELIOMOTION QUICK ASSEMBLY GUIDE PV-650

Installation, Operation and Maintenance Manual

Sunwize Power Ready Express Quick Start

User Manual WatchPower App

Solar Hybrid Inverter SP Brilliant Grid Series

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA-5KVA INVERTER / CHARGER

Owner s Manual. Contents GP-PWM-10-SQ

Sunwize Water Pumping Kit Quick Start

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Solar Hybrid Inverter SP Brilliant Series

User Manual 1.5KVA-3KVA INVERTER / CHARGER

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Eclipse Solar Suitcase

The Traveler Series: Wanderer

Solar Hybrid Inverter SP Efecto Series

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

The Traveler Series: Wanderer

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

SOLARINVERTER MPPT 4KVA - 5KVA

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Oberbauer/ITEX Solar Power Systems

Solar Hybrid Inverter SP Efecto Series

Instruction of Solar Charge Controller. User s Manual

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

The Traveler Series: Adventurer

Duo Battery Charge Controller

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

Photovoltaics. MPI Hybrid Series

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Solar Hybrid Inverter SP Initial Series

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

Instruction of Solar Charge Controller. User s Manual

User Manual. Solar Charge Controller 3KW

according to VDE AR-E Manual V 3.1

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 3KW-5KW. Appliances. Airconditioning Fridge. Washing machine

HYBRID SOLAR INVERTER HYBRID SOLAR INVERTER 3KW-5KW. Appliances. Airconditioning Fridge. Washing machine

HYBRID SOLAR INVERTER

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 3KW 120VAC. Appliances. Airconditioning Fridge. Washing machine

F I R S T! Assembly* 4 Battery systems pull toward you, or 8 battery systems Lift up, both sides with a. Fig. B. *performed by licensed electrician

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

The Traveler Series TM : Adventurer

HYBRID SOLAR INVERTER

SGL2 Solar LED landscape Lamp. Instruction manual

SCC-MPPT Solar Charge Controller

HYBRID SOLAR INVERTER HYBRID SOLAR INVERTER 3KW-5KW. Appliances. Airconditioning Fridge. Washing machine

SCC-MPPT Solar Charge Controller

Solar Charge Controller

User Manual. UPower Series. Inverter/charger

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Owner s Manual. Solar Controller GP-PWM-30

SCC-MPPT Solar Charge Controller

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

DUAL/TRIPLE MPPT INVERTER / CHARGER. User Manual

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

ETATRACK active. Installation of Controller and Motor. 1 Function of the ETATRACK active Controller

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

User Manual 3KVA/5KVA 24V INVERTER / CHARGER. Version: 1.1

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

User Manual Solar Charge Controller 3KW

User Manual. Hybrid PV Inverter. Version: 2.1

Battery Power Inverters

Steca Solarix PLI. Inverter / Charger with Solar Charge Controller. Installation and operating instructions. Download manual at

User Manual G1 Solar MPPT Inverter Solar MPPT Charger English version..1

User Manual. Hybrid 4KW PV Inverter. Version: 1.2

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

SAFETY INSTRUCTIONS INTRODUCTION

100W Basic Kit (GS-100-Basic)

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

SOLAR INVERTER/CHARGER

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

MULTI-POLE MOUNT LARGE GROUND MOUNT. Assembly Instructions. Assembly Instructions. step-by-step assembly and installation

The Solar Power Kit includes the following components. Please be sure you have all listed components before beginning. 5/16" x 2" Carriage Bolt

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

ORVALDI Solar Infini 5kW

Steca Elektronik SOLARIX PLI

APPENDIX: APPROCIMATR BACK-UP TIME TABLE

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

OHY3P kW Hybrid Inverter (3-Phase) USER MANUAL V2.0

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

User Manual. SP10000 Premium

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

LS0512 Solar Charge Controller

Transcription:

HELIOMOTION QUICK ASSEMBLY GUIDE PV-1300

PART I - FOUNDATION 1x 1x

1 Make a hole for the concrete at your chosen location. Refer to the manual for recommended volume. 2 Fill the hole with concrete up to a few centimeters below ground level. 3 Push the rod unit into center of the concrete and let the flange rest on top of it. Use a spirit level to align the flange horizontally. Allow the concrete at least 1 week to set before assemling the remainder of the power plant. Cover the concrete with soil after it has cured for 4 weeks. Rod unit 1x

4 1x 1. Adjust bottom nuts to vertically align the column. 2. Tighten both top and bottom nuts to secure the column.

PART II - TRACKER 1x 4x

1 4x 1x Leave nuts loose 2 The tracker needs to be turned to face true south in the northern hemisphere or true north in the southern hemisphere. To do so follow these steps. 1. Launch the compass app on your smart phone. This compass is GPS compensated, making it more accurate than a regular compass. 2. Align the phone to true south (or north) according to the compass. 3. Turn the tracker so that the edge of the balk lines up with the edge of the phone. Make sure the compass is not distorted by being too close to any metal objects. 4. Tighten the bolts holding the tracker to the foundation column.

PART III - FRAMEWORK 2x 4x 1x 1x 2x 12x

1 970mm 485mm Slide nuts into the profile slots from the side. 1x 4x 1x 2 2400mm 2x 580mm

3 1120mm 2x 1120mm 4 8x 45mm 45mm 840mm 840mm

5 795mm 795mm PROFILE LENGTH 4x X 970mm Cut profiles to appropriate length if needed X PROFILE LENGTH = SOLAR PANEL WIDTH * 2 = mm X = PROFILE LENGTH - 970 = mm 2

PART IV - FORK M10x16 M10 M6x6 M6 1x 4x 4x 2x 2x 1x 1x

1 1x 4x 4x Align fork with forward marker 2 2x 2x

3 Angle rod R 1x Extension rod F 1x 1. Combine the angle rod and the extension rod. 2. Make sure both fork joints (F) are unscrewed halv a turn. 3. Attach rod ends (R) to the fork joints.

PART V - PANELS 4x M8 M8x20 M8x60 16x 6x 4x 2x 16x 16x 1x 2x 4x

1 B P 360mm 4x 16x 2 1. Lift a panel onto the frame. Make sure cable box (B) is facing inwards. 2. Position the panel as illustrated and lock it into place with four panel clamps (P). 3. Repeat these steps for the remaining three panels. 4x 2x 250mm 250mm 2x 4x 6x 400mm Attach weights so that they counterbalance the weight of the panels. Typical distances illustrated.

3 4 Remove the extension rod and attach the angle rod. 1. Connect the PV cables together according to application, making sure to leave the last two plus and minus connectors unconnected. 2. Attach PV cables to the frame using cable ties and selfadhersive clip anchors. When used with a grid-tied inverter the panels are typically connected in series to get a sufficiently high voltage. The voltage range for the SMA Sunny Boy 1.5 is 80-600 VDC. Series When used with a batterytied system the panels are typically connected in parallel as needed to limit the voltage. The voltage range for the MPPSolar 2424MSX is 30-115 VDC. Parallel+Series 16x 16x 55V 6A 55V 6A _ + _ + _ + _ + + _ + _ + _ + 220V 6A + _ 110V 12A +

Grid-tied system - Part I R P M V Q K 1. Use included U-bolt clamp (M) and support plate (P) to mount the inverter (V) at the top of the foundation column. 2. Mount the junction box (K) under the inverter using another included support plate (Q) and U-bolt clamp. 3. Attach the cable protection pipe (R) to the support plates using cable ties.

Grid-tied system - Part II A P V Fuse (F) R H R + - L N G Transformer (T) 24VDC AC switch (S) L N L N G Utility AC (U) Ground (J) The PV solar panels (P) and utility AC (U) must be connected by a certified electrician. However, the preparation work may be done by a layman as long as local code requirements are followed. Please read the inverter's user manual for additional information. AC wires must be at least 1.5mm² thick and use an outdoor cable (such as MCMK). Be mindful of the AC labels and wire colors: Neutral (N) is blue, Phase (L) brown and ground (G) green-yellow. 1. Connect the 24V cable in the pipe from the 24VDC transformer (T) to the ±24V terminal in the tracker s junction box (A). 2. Locate the AC and PV connectors that come with the inverter. 3. Mount the PV connector on the PV cable through the pipe. The PV connector with a plus (+) sign is to be mounted on the red wire. Then attach the PV connectors to the inverter. 4. Mount the AC connector on the AC cable (MCMK 2x2.5+2.5mm²) that is to be wired to the inverter. Note that the cable must first be pulled through the protective cover (H). Connect the AC connector to the inverter's AC terminal and then fasten the protective cover.

Grid-tied system - Part III 5. Fill out and attach the included self adhesive warning labels. These dual supply labels need to be provided near the inverter, the fuse box, and the utility meter, to indicate the presence of on-site generation and the placement of the AC switch (S). 6. It is necessary to ground (J) the installation and inverter to prevent them from causing electrical shocks in case of damage. The installation needs to be grounded by connecting a 6mm² copper wire from one of the threaded rods at the foundation to the AC ground in the junction box. Likewise, the inverter has a ground point on its back side. 7. Acquire a MCMK outdoor cable long enough to reach from the junction box (A) to the fuse box inside the house. A 1-phase inverter needs a cable with two wires plus a surrounding shield (2x2.5+2.5mm²). 8. Wire the cable from the junction box to the fuse box. It is recommended to pull underground sections through a cable duct. 9. Make sure that cable sections above ground are properly attached. Sections coming out of the ground need to be protected by for example a U-profile made of metall. 10. Fasten loose cable sections using cable ties around the installation. Contact a certified electrician and have them inspect the installation and carry out the remaining tasks. 1. Check that all cables are correctly wired in the junction boxes (A and K). 2. Connect the AC cable to the selected phase through a fuse in the fuse box. 3. Connect the PV cable connectors to the solar panels (P). 4. Turn on the AC switch (S) in the junction box (K) to power the inverter. 5. Turn on the fuse (F) to start the tracker. It takes a few minutes for it to start. 6. Turn on the DC switch on the left side of the inverter to connect the solar panels. 7. Check the status lights on the inverter. Grid feed-in starts after about 30 seconds, which is indicated by a green light either shining or pulsating.

Off-grid system - Part I M K P Use included U-bolt clamp (M) and support plate (P) to mount the junction box (K) at the top of the foundation column.

Off-grid system - Part II A P U V G +24V Ground PV- PV+ J B C K Breaker (F) The PV solar panels (D) and any utility AC must be connected by a certified electrician. However, the preparation work may be done by a layman as long as local code requirements are followed. Please read the solar station's user manual for additional information on how to install and configure the station. 1. Mount the solar station (V) indoors on a wall where you want it, preferably at face level. Use a small screwdriver to remove the service panel at the bottom of the station to access its terminals. 2. Put up the PV disconnect switch (J) and the junction box (C) on the wall near the solar station. Then connect a suitable two-wire cable (2x2.5mm²) from the solar station's PV input terminals to the terminals in the junction box through the PV switch. Make sure the switch is turned off. 3. Connect the batteries (B) together to get the required voltage for the solar station. Be very careful to avoid short circuiting the batteries. Use a voltage meter to confirm you have wired the batteries correctly. 4. Put up the battery disconnect switch (G) on the wall and make sure it is switched off. Connect the positive terminal from the battery array to the solar station's positive battery input terminal through the battery switch and through a 200A fuse. Use the red 1x16mm² cable. 5. Wire the black 1x16mm² cable from the negative terminal on the battery array to the solar station's negative battery input terminal.

Off-grid system - Part III 6. Wire a cable with two conductors from the 24V terminal in junction box (A) to junction box (K). Connect the +24V wire to the breaker (F) and the ground wire to one of the screwterminals next to the breaker. Make sure the breaker is switched off. 7. Wire a MCMK outdoor cable with four conductors (4x2.5mm²) from the four terminals in junction box (K) to the terminals in junction box (C). It is recommended to pull underground sections through a cable duct. Make sure that cable sections above ground are properly attached. Sections coming out of the ground need to be protected by for example a U-profile made of metall. 8. Connect the included PV cable to the remaining two screw terminals in junction box (K). Do not connect the PV contacts to the solar panels yet. 9. Fasten loose cable sections using cable ties around the installation. Contact a certified electrician and have them inspect the installation and carry out the remaining tasks. 1. Check that all wires are correctly installed in the indoor and outdoor junction boxes (A, K and C). 2. To power the solar tracker, wire a cable (2x2.5mm²) to the screw terminal in junction box (C) so that it connects to the 24V terminal in junction box (A). Join the 24V plus side to the terminal supplied with a fuse. After this has been done, connect the two wires directly to the battery's 24V plus and minus sides. Be careful not to short-circuit the battery's terminals. 3. Wire the AC output from the solar station to the fuse box to distribute power to outlets (U). 4. If the building has utility power then connect it to the AC input terminal at the solar station. 5. Connect the PV cable's connectors to the solar panels (P). Make sure that the polarity is correct at the PV switch (J) and from there to the solar station (V). 6. Reattach the service panel to the bottom of the solar station. 7. Switch on the breaker (F) in the junction box (K) to start the solar tracker. It takes a minute or two for the tracker to begin rotating. 8. Turn on the battery switch (G) to power on the solar station (V). The station will beep for a few seconds. 9. Turn on the PV switch (J) to enable solar charging. 10. Turn on the solar station's inverter using the switch found at the bottom right or right side of the device. 11. Confirm that wall outlets (U) connected to the solar station are powered.

Battery-tied inverter - Part IV The solar station can be configured using the buttons below the display. To access the settings hold the enter button on the right side of the display for a few seconds. Recommended settings are listed in the table below. Please refer to the solar station's manual for more information. Number Description Setting 01 Output source priority SbU (solar or battery) 02 Maximum charging current 60A 03 AC input voltage range APL 04 Power saving mode SdS (disabled) 05 Battery type Gel 06 07 Auto restart on overload Auto restart on high temperature LtE (enabled) TtE (enabled) 12 Voltage point back to utility 22V 13 Voltage point back to battery FUL (full charge) 16 Charge source priority OSO (only solar) 18 19 Alarm control Auto return to default screen bof (alarm off) EPS (yes) 20 Backlight control LON (on) 22 Beep when primary source interrupted AOF (off) 23 Overload bypass bye (enabled) 26 Bulk charging voltage 29.2V 27 Float charging voltage 27.0V 29 Low DC cut-off voltage 21.0V Keep in mind that batteries should not be left completely discharged for any longer period of time as it reduces their capacity and lifespan. If the winter season has little or no sunshine care must be taken to prevent the batteries from being drained in one of the following ways: 1. If utilty or generator power is available, setting 16 (charging priority) of the solar station can be switched from OSO (charge only from the sun) to CSO (charge from the sun if available, otherwise from utlity/generator). 2. If the system is not used during winter the batteries should be left fully charged and completely disconnected from all loads.