Similar documents
Rhino SD3/XD3 Air Motor

Rhino SD3/XD3 5-Gallon Follower Modules

EcoLiner Compound Gun

Universal Automatic Non-Conductive Fluid Regulator

Mastic Gun. Customer Product Manual Part A. Issued 2/04 NORDSON CORPORATION AMHERST, OHIO USA

2 8 CC Ejector Gun. Customer Product Manual Part

Ink-Dot Hydraulic System with Reservoir Manifold

A7A Single and Dual Automatic Airless Spray Guns

Auto-Flo II Dispense Valves for Pro-Meter-S and -S2K Applications

High-Pressure Fluid Filters

Rhino SD2/XD2 Frames

Pro-Meter Gear Metering Pump

A16A Inside Stripe Gun

Trilogy Air Spray and LVLP Automatic Spray Guns

Prodigy HDLV Generation II Pump Panel

Trilogy Air-Assisted Airless Manual Spray Gun

CleanSpray XT Spray Guns

MEG Inside Stripe Applicator

Low-Pressure Color Change Manifold

Pro-Swirl Applicator and Controller

Encore HD Powder Spray System with Prodigy Pump Cabinet

7- and 10-Inch Air Motors with Air Valve

Circulating and Non-Circulating Color Change Manifolds

Trilogy GP Air Spray and LVLP Gravity Fed Manual Spray Guns

Flow-Through-Felt Gravity Feed Applicator Tool

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Pump Manifold and Circuit Board

StediFlo 3:1 and 6:1 Low Pressure Pumps

Rhino SD2/XD2 Hydraulic Section

Flow-Through-Felt Controller for Gravity Feed Applicators

Encore HD Automatic System Standalone Pump Stand

EP2 Pump System. Customer Product Manual Part A02

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Auto-Flo II Anti-Drool Dispense Valves

RA-20 Rotary Atomizer

HIVISC CE20 Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

0 8 CC Accu-Drop Ejector Dispense Gun

SureMix Dispensing System

Auto-Flo Air-Assist Automatic Dispensing Valve

Kinetix Electrostatic Spray Gun Automatic Version 60 kv Air Spray and KVLP Waterborne

Trilogy Waterborne Electrostatic HVLP and Air Spray Automatic Gun

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Kinetix Electrostatic Spray Gun Automatic Airless

. OBSOLETE, THIS DOCUMENT IS NO LONGER MAINTAINED. 2K Meter with Servo Drive

CS-2T Timer. Customer Product Manual Part A

Econo-Coat Manual Powder Spray Gun

Sure-Max Powder Transfer System

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Manual Clear Primer Application System

Tribomatic II Extended Automatic Powder Spray Gun

Tribomatic II Purgeable Automatic Powder Spray Gun

Pro-Meter S-Series Dispensers

NVR-Series Vertical Reciprocators

Big Bag Unloader. Customer Product manual Part Number Issued 07/17

Vantage Manual Powder Spray Gun

EP-2 Si Three-Piston Pump

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Paint/Solvent/Dump Valve and Flow-Through Valve

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

EP-2 Three-Piston Pump

Inverted High Pressure Fluid Filters

Circulation Kits for CP Pumps

Encore HD Pump. For parts and technical support, call the Finishing Customer Support Center at (800)

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump

Pro-Meter S-Series Dispensers

Installing an H-200 Integral Right-Angle Module

Pro-Meter S2K-Series Dispensers

0-800 psi Carbide Seat Fluid Pressure Regulator

Two-Component Meter. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

RA-20 Paint/Solvent/Dump Valve

Hard Seat Fluid Pressure Regulator

Versa-Spray IPS Manual Electrostatic Porcelain Enamel Powder Spray Gun

Instructions Parts List

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800)

Spray Pressure Control Manifold

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Standard and Conical AN Series Air Spray Nozzles

SP30 10:1 Piston Pump

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Prodigy Manual Powder Spray Guns

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Spray Pressure Control Manifold

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

902 Powder Coating Booth

Liquidyn P-Dot CT Jet Valve

0 900 psi Pressure-Reducing Diaphragm Regulator

Prodigy HDLV Pump Generation III, Pump Manifold and Circuit Board

Prodigy Automatic Powder Spray Guns

Inverted Dual High-Pressure Fluid Filter Assemblies

Pro-Flo r III Standard Flow Dispensing Gun

Model C-1 Electrostatic Airless Spray Gun OBSOLETE. Customer Product Manual. Part D NORDSON CORPORATION AMHERST, OHIO USA

TCU Flushing Manifold and RTD Installation

INSTRUCTIONS PARTS LIST

TWO COMPONENT SYSTEM METERING VALVE

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

0-500 PSI Soft Seat Fluid Pressure Regulator

SB-E ISS.05. Operation Manual AA4400A Automatic Air Assisted Airless Spray Gun

Versa-Spray IPS Automatic Electrostatic Porcelain Enamel Powder Spray Gun

Pro-Swirl Manifold Air Heater

Transcription:

A7A Lancing pray Guns Customer Product Manual Issued 8/18 For parts and technical support, call the Industrial Coating ystems Customer upport Center at (800) 33-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version. NORDON CORPORATION AMHERT, OHIO UA

Table of Contents afety... 1 Qualified Personnel... 1 Intended Use... 1 Regulations and Approvals... 1 Personal afety... 1 High-Pressure Fluids... 2 Fire afety... 2 Halogenated Hydrocarbon olvent Hazards. 3 Action in the Event of a Malfunction... 3 Disposal... 3 Description... Introduction... pecifications... 5 Equipment Labels... 5 A7A M Lancing pray Gun ATEX Markings (P/N 16083)... 5 Operation... 6 Installation... 7 Recommended Circuit A7A Circulating Lancing pray Gun... 7 Recommended Circuit A7A M Lancing pray Gun... 8 Mounting... 9 Fluid Connections... 9 Air Connection... 9 Nozzle Installation... 9 Pressure Transducer... 10 CO-Plate... 10 CO-Plate Installation... 10 Troubleshooting... 11 Repair... 12 Preparation... 12 Disassembly... 12 Assembly... 12 Parts... 15 ervice Kits... 19 Adhesives, ealants and Lubricants... 19 Options... 19 Air Release Valve... 19 Pressure Transducer... 19 CO-Plate... 20 Nozzles... 21 Contact Us Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General information about Nordson can be found on the Internet using the following address: http://www.nordson.com. Address all correspondence to: Nordson Corporation Attn: Customer ervice 555 Jackson treet Amherst, OH 001 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 1997. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks itrax, Nordson and the Nordson logo are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owners.

Change Record i Revision Date Change 03 9/17 Added transducer to parts list. 0 8/18 Revised ATEX label. 05 8/18 Added new part number for O- ring lubricant. Change Record

ii Change Record

A7A Lancing pray Guns 1 A7A Lancing pray Guns afety Read and follow these safety instructions. Taskand equipment-specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure all equipment documentation, including these instructions, is accessible to persons operating or servicing equipment. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. ome examples of unintended use of equipment include using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. Personal afety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment. While operating manual spray guns, make sure you are grounded. Wear electrically conductive gloves or a grounding strap connected to the gun handle or other true earth ground. Do not wear or carry metallic objects such as jewelry or tools. If you receive even a slight electrical shock, shut down all electrical or electrostatic equipment immediately. Do not restart the equipment until the problem has been identified and corrected.

2 A7A Lancing pray Guns Personal afety (contd) Obtain and read afety Data heets (D) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. Make sure the spray area is adequately ventilated. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. High-Pressure Fluids High-pressure fluids, unless they are safely contained, are extremely hazardous. Always relieve fluid pressure before adjusting or servicing high pressure equipment. A jet of high-pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning. If you suffer a fluid injection injury, seek medical care immediately. If possible, provide a copy of the Dfortheinjectedfluidtothehealthcare provider. The National pray Equipment Manufacturers Association has created a wallet card that you should carry when you are operating high-pressure spray equipment. These cards are supplied with your equipment. The following is the text of this card: WARNING: Anyinjurycausedbyhigh pressure liquid can be serious. If you are injured or even suspect an injury: Go to an emergency room immediately. Tell the doctor that you suspect an injection injury. how him this card Tell him what kind of material you were spraying MEDICAL ALERT AIRLE PRAY WOUND: NOTE TO PHYICIAN Injection in the skin is a serious traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Consultation with a plastic surgeon or a reconstructive hand surgeon may be advisable. The seriousness of the wound depends on where the injury is on the body, whether the substance hit somethingonitswayinanddeflectedcausing more damage, and many other variables including skin microflora residing in the paint or gun which are blasted into the wound. If the injected paint contains acrylic latex and titanium dioxide that damage the tissue s resistance to infection, bacterial growth will flourish. The treatment that doctors recommend for an injection injury to the hand includes immediate decompression of the closed vascular compartments of the hand to release the underlying tissue distended by the injected paint, judicious wound debridement, and immediate antibiotic treatment. Fire afety To avoid a fire or explosion, follow these instructions. Ground all conductive equipment. Use only grounded air and fluid hoses. Check equipment and workpiece grounding devices regularly. Resistance to ground must not exceed one megohm. hut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Do not heat materials to temperatures above those recommended by the manufacturer. Make sure heat monitoring and limiting devices are working properly.

A7A Lancing pray Guns 3 Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local codes or your material D for guidance. Do not disconnect live electrical circuits when working with flammable materials. hut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shutoff valves, and fire extinguishers are located. If a fire starts in a spray booth, immediately shut off the spray system and exhaust fans. hut off electrostatic power and ground the charging system before adjusting, cleaning, or repairing electrostatic equipment. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: Disconnect and lock out system electrical power. Close hydraulic and pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the system. Disposal Dispose of equipment and materials used in operation and servicing according to local codes. Halogenated Hydrocarbon olvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components. Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage. Halogenated hydrocarbon solvents contain one or more of the following elements: Element ymbol Prefix Fluorine F Fluoro- Chlorine Cl Chloro- Bromine Br Bromo- Iodine I Iodo- Check your material D or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your Nordson representative for information about compatible Nordson components.

A7A Lancing pray Guns Description Introduction The Nordson A7A Lancing pray Guns are air-operated, high-cycle, airless spray guns used primarily in the aerosol container industry. The guns are available in a standard model, the A7A Circulating Lancing pray Gun, and in a non-circulating itrax r compatible model, the A7A pray Monitor (M) Lancing pray Gun. The guns are designed to spray solventborne or waterborne coatings. They are constructed of stainless steel with a 293 mm (11.53 in.) extension. An optional air-release valve can be used for quick gun response over long distances. NOTE: These spray guns use Nordson Tube Lining Cross-Cut nozzles. The nozzles are optional and must be ordered separately. Contact your Nordson representative for nozzles suited for your application. A7A Circulating Lancing pray Gun (hown without Nozzle) A7A pray Monitor (M) Lancing pray Gun (hown without Nozzle) Figure 1 A7A Lancing pray Guns

A7A Lancing pray Guns 5 pecifications pecification 17096 A7A Circulating Lancing pray Gun 16083 A7A M Lancing pray Gun Extension length: 293 mm (11.53 in.) 293mm(11.53in.) Gun Body Dimensions: Length Width Height 103 mm (.07 in.) 38 mm (1.5 in.) 38 mm (1.5 in.) 103 mm (.07 in.) 38 mm (1.5 in.) 6 mm (2.52 in.) Weight 1180 grams (2.6 lbs) 1270 grams (2.8 lbs) Maximum Air Pressure 8.27 bar (120 psi) 8.27 bar (120 psi) Minimum Air Pressure 2.75 bar (0 psi) 2.75 bar (0 psi) Maximum Fluid Pressure 117 bar (1700 psi) 117 bar (1700 psi) Nozzle Mounting Threads #10-32 #10-32 Equipment Labels A7A M Lancing pray Gun ATEX Markings (P/N 16083) A7A EXTENDED M GUN AMHERT, OHIO UA 001 P/N: 16083 /N: XXXXXXXXXX File ref: 001 hiibt6gb

6 A7A Lancing pray Guns Operation ee Figure 2. When the spray guns are open, compressed air enters the air inlet fitting (2) and lifts the piston (1) and shaft (), compressing the packing cartridge spring (3) and pulling the ball (7) off the seat (6). When the air pressure is removed, the packing cartridge spring forces the ball back into the seat and stops the flow of coating material. When the standard A7A spray gun is closed, coating material circulates through the fluid fitting (5), through the shaft (), around the seat (6), then back to the return fitting. When the A7A M Lancing pray Gun is closed, coating material circulates through the gun body only. 1 2 3 5(Return) 7 6 A7A Circulating Lancing pray Gun (hown with nozzle) 9 8 2 10 11 1 3 7 6 A7A M Lancing pray Gun (hown without nozzle; fluid fittings and transducer plugs not shown) 9 Figure 2 A7A Lancing pray Gun Components and Operation 1. Piston 5. Fluid fittings 2. Air inlet fitting 6. eat 3. Packing cartridge spring 7. Ball. haft 8. Nozzle (Optional) 9. Barrel 10. CO-plate plug 11. CO-plate (Optional)

A7A Lancing pray Guns 7 Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Before installing the gun, relieve fluid pressure and shut off electrical power. WARNING: Install an approved pressure relief device set at 117 bar (1700 psi) in the fluid line to the spray gun. Fluid supply hoses must have a minimum burst pressure of 117 bar (1700 psi). Recommended Circuit for A7A Circulating Lancing pray Gun ee Figure 3 for a typical spray gun system, single gun. Review this recommended plumbing circuit before installing any parts into the system. Additional customer-supplied parts may be required. 1 2 3 5 6 7 9 8 10 11 Figure 3 Typical pray Gun Installation (A7A Circulating Lancing pray Gun) 1. CP pump (or other with similar output) 5. olenoid valve 2. Heater 6. Air pressure regulator 3. Fluid filter 7. Air supply line. Fluid pressure regulator 8. A7A spray gun 9. Circulation valve 10. Drain valve 11. Coating supply

8 A7A Lancing pray Guns Recommended Circuit for A7A M Lancing pray Gun ee Figure for a typical dual or multiple spray gun system using pray Pressure Control. Review this recommended plumbing circuit before installing any parts into the system. Additional customer-supplied parts may be required. 5 6 7 3 2 1 DRAIN DRAIN UPPLY DRAIN 10 9 8 Figure Typical pray Gun Installation (A7A M Lancing pray Gun) 1. EP Pump (or other with similar output) 5. Pressure-reducing regulator 2. Two-way ball valve 6. pray gun 3. Heater 7. PC manifold assembly. Filter 8. Back pressure regulator 9. Two-way ball valve 10. Three-way ball valve (drain)

A7A Lancing pray Guns 9 27 mm (1.063 in.) 5 2 6 8 1 3 A7A Circulating Lancing pray Gun (hown without Nozzle) 8 3 7 1 5 2 A7A M Lancing pray Gun (hown without Nozzle) 6 Figure 5 Mounting and Connections 1. 1 / 8 NPT fitting (air) 2. 1 / 2-20 JIC fitting (supply) 3. 1 / 2-20 JIC fitting (return). Barrel nut 5. Barrel 6. Nylon washer Note: Fluid fittings (2, 3) for A7A M Lancing pray Gun can be used for either supply or return. 7. CO-Plate plug and O-ring 8. Mounting holes Mounting Use two #10 screws to mount the gun. Fluid Connections CAUTION: Do not overtighten the fluid fittings. Overtightening may cause damage to the gun body. Nozzle Installation The nozzles used with this gun are Tube Lining Nozzles. If not already installed, install a nylon washer (6) on the end of the barrel (5), then screw the nozzle on and tighten it securely. Loosen the barrel nut () and rotate the barrel to point the nozzle in the desired direction. ee Figure 5. Connect 1 / 2-20 JIC fluid hoses to the 1 / 2-20 JIC fluid fittings (2, 3). Air Connection NOTE: Do not use an air hose any longer than necessary between the gun and the solenoid. The longer the air hose, the longer the pneumatic delays, causing slow on and off cycling. Connect the solenoid directly to the air inlet, if possible. ee Figure 5. Connect an electro-pneumatic solenoid to the 1 / 8 in. NPT fitting (1).

10 A7A Lancing pray Guns Pressure Transducer When the A7A M Lancing pray Gun is installed as part of a itrax spray monitor system, install a pressure transducer in the gun body to monitor fluid pressure at the gun. Refer to Pressure Transducer on page 19 for transducer ordering information. Refer to the pressure transducer instruction sheet for more installation instructions. There are two plugged ports on opposing sides of the gun body for installing a pressure transducer. Either port can be used. Remove the plug and O- ring from the desired port and install the pressure transducer. Tighten the transducer securely. CO-Plate When the A7A M Lancing pray Gun is installed as part of a itrax spray monitor system, install a carbide CO-plate in the gun body to produce a controlled pressure drop when the gun is spraying. Refer to the CO-Plate election Chart on page 20 for CO-plate ordering information. CO-Plate Installation 1. (ee Figure 5.) Remove the CO-plate plug and O-ring (7) from the top of the circulation block. 2. (ee Figure 6.) Loosely thread the CO-plate onto the CO-plate puller tool shipped with the spray gun. 3. Insertthepullerintotheportandpushittoseat the O-ring. Partially unscrew the puller from the CO-plate then push it again to make sure the CO-plate is seated.. Unscrew the puller from the CO-plate. 5. Reinstall the CO-plate plug and O-ring and tighten securely. (7) CO-Plate Puller Tool Installation of CO-Plate Fully Installed CO-Plate Figure 6 CO-Plate Installation

A7A Lancing pray Guns 11 Troubleshooting WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. These troubleshooting procedures cover only the most common problems. If you cannot solve a problem with the information given here, contact your local Nordson representative for help. Problem Possible Cause Corrective Action 1. Gun leaks around nozzle Dirty or damaged nylon washer Relieve system fluid pressure. Remove the nozzle and clean or replace the nylon washer. 2. Gun leaks around barrel nut 3. Gun leaks through the weep hole in the gun body directly behind the fittings Dirty or damaged metal sealing surfaces Worn packing cartridge Relieve system fluid pressure. Remove the barrel nut and clean or replace the barrel. Replace the packing cartridge and seals. Refer to Parts for the seal kit and packing cartridge part numbers.. Gun spits Dirty or worn ball tip or seat Relieve system fluid pressure. Clean or replace the ball tip and seat. 5. On/Off cycle response is poor or non-existent Long trigger air lines Air trapped in fluid system Airpistonwornoroutof adjustment Mount the solenoid valve on or as closeaspossibletothegun. Purge the air from the fluid system. Adjust or replace the air piston assembly. Low pressure to the air solenoid Increase the air pressure to 2.7.13 bar (0-60 psi). Long trigger air lines High fluid pressure Mount the solenoid on or as close as possible to the gun. Reduce the fluid pressure at the pump. The maximum pressure allowed is 117 bar (1700 psi).

12 A7A Lancing pray Guns Repair WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Preparation 6. Flush the gun with a compatible solvent before you remove it from the system. WARNING: Relieve system fluid pressure before disconnecting the fluid hoses. Failure to observe this warning may result in serious injury or death. 7. Relieve both fluid and air pressure to the gun. 8. Disconnect the air and fluid lines and remove the spray gun from its mounting. Disassembly eefigures7and8. 1. Remove the nozzle and nylon washer (21). 2. Remove the screws (20), lockwashers (), and air cylinder (19). 3. Remove the gasket (18).. Use the wrenches provided with the gun to unscrew the lock nut (6A). 5. Use the wrenches to unscrew the piston assembly seal nut (6B). 6. Remove the piston assembly (6). 7. Unscrew the barrel nut (10) and remove the barrel (5). 8. Discard the O- ring (22) in the extension body. 9. Insert a small screwdriver through the hole in the ball tip (12) and unscrew the ball tip from the shaft (11). 10. Remove the screws (3) and lockwashers (). Carefully pull the extension body (2) off the shaft. 11. tandard A7A gun only - Remove the seal retainer (1) and seal (13) from the extension body with a screwdriver. 12. Unscrew the shaft (11) from the spring end of the packing cartridge (8). 13. Push the packing cartridge out of the gun body (16). 1. Remove the O-ring (17) from the gun body. 15. Unscrew the old seat (12) from the barrel. Install a new seat and O-ring (12A). Tighten theseatto1.7-2.2ndm (15-20 in. lbs). Assembly NOTE: Use only water-based lubricant on the O-rings and seals. 1. Install a new O-ring (17) in the gun body (16). 2. Coat the packing cartridge (8) with a small amount of lubricant and install it in the gun body. 3. Thread the shaft (11) onto the packing cartridge and tighten it securely.. tandard A7A gun only - Install the seal (13) and the seal retainer (1) into the extension body (2). Tighten the seal retainer with a screwdriver. 5. Install a new O-ring (15) on the extended gun body. 6. Install the extended body over the shaft and secure it to the gun body with the screws (3) and lockwashers (). 7. Install the new ball tip (12) on the shaft. 8. Install the new seat (12) on the barrel (5). 9. Install a new O- ring (22) on the extension body. 10. Install the barrel over the shaft and onto the extension body. Tighten the barrel nut (10) securely. 11.Installthepistonassembly(6)onthepacking cartridge stem. Do not tighten the lock nut (6A). 12. crew the piston assembly onto the packing cartridge stem clockwise until it comes to rest against the gun body. Turn the piston assembly counter-clockwise 1 1 / 2 turns. 13. Apply a drop of thread-locking compound to the lock nut threads. Hold the packing cartridge stem with a wrench and tighten the lock nut. 1. Install the air cylinder gasket (18) and air cylinder (19). ecure the cylinder with the screws (20) and lockwashers ().

A7A Lancing pray Guns 13 20 19 6 6A 18 17 16 8 7 6 6B 6C 15 11 2 1 13 9 11 10 22 3 12 12A 5 12 21 ervice Notes: Apply O-ring lubricant part 1612251 (Parker O-Lube or equivalent) before installing. Apply 9002 threadlock compound to threads before tightening. Apply 90081 pipe adhesive/sealant to threads before installing. Ball and eat are a matched set and must be replaced together. Ball Tip eat Figure 7 Repair (A7A Circulating Lancing pray Gun)

1 A7A Lancing pray Guns 20 19 6 6A 18 17 16 8 7 6 6B 6C 15 2 23 2 11 10 3 11 22 5 12 12A ervice Notes: Apply O-ring lubricant part 1612251 (Parker O-Lube or equivalent) before installing. Apply 9002 threadlock compound to threads before tightening. Ball Tip eat 12 21 Apply 90081 pipe adhesive/sealant to threads before installing. Ball and eat are a matched set and must be replaced together. Figure 8 Repair (A7A M Lancing pray Gun) 2. Extension body 8. Packing cartridge 3. crews (2 in. long) 9. Elbows (stainless steel). Lockwashers 10. Barrel nut 5. Barrel 11. haft 6. Piston assembly 12. Ball and seat module 6A. Lock nut 12A. O-ring (EPR) 6B. eal nut 13. eal (PTFE) 6C. O-ring (brown Viton) 1. eal retainer 7. Elbow (brass) 15. O-ring (EPR) 16. Gun body 17. O-ring (EPR) 18. Gasket 19. Cylinder 20. crews (1 in. long) 21. Nylon washer 22. O- ring (EPR) 23. CO-plate plug 2. CO-plate

A7A Lancing pray Guns 15 Parts eefigures9and10. Item Part (A7A Circ) Part (A7A M) Description Quantity Note ------ 17096 ------ GUN, A7A, circ, 11.53 (293 mm) 1 ------ ------ 16083 GUN, A7A M Lancing pray Gun, 11.53 (293 mm) 1 1 703191 703191 PLUG, pipe, socket, flush, 1 stainless steel, 1 / in. NPT 2 160708 160708 BODY, extension 1 3 981127 981127 CREW, fil, 10-32 x 2.00 in., 6 steel, zinc 983120 983120 WAHER, lock, split, #10, steel, 8 nickel 5 17931 17931 BARREL, 11.53 (293 mm) 1 6 ------ ------ PITON, locknut, assembly 1 B 6A ------ ------ NUT, lock, 10-32, upper 1 B 6B ------ ------ NUT, seal lock 1 B 6C ------ ------ O-RING,Viton,0.208in.IDx 0.070 in. wide, brown 1 B, E 7 973125 973125 ELBOW, pipe, 1 / 8 in.npt,brass 1 8 17097 17097 CARTRIDGE, packing, stainless 1 steel, EPR 9 972177 972177 ELBOW, male, 37, 1 / 2-20x 2 1 / in. NPT, stainless steel 10 123200 123200 NUT, nozzle, anti-foul,stainless 1 steel 11 17921 17921 HAFT, 11.53 (293 mm) 1 12 ------ ------ MODULE, ball and seat 1 A 12A ------ ------ O-RING, EPR, 0.258 x 0.336 x 0.039 in. 1 A, C, E 13 ------ ------ EAL, PTFE, 0.156 x 0.375 x 1 C 0.1 in. 1 17938 ------ RETAINER, seal, A7A 1 15 ------ ------ O-RING, EPR, 0.688 x 0.813 x 1 B, C, E 0.063 in. 16 ------ ------ BODY, gun 1 17 ------ ------ O-RING, EPR, 0.563 x 0.688 x 1 B, E 0.063 in. 18 153031 153031 GAKET, gun, H20 1 B 19 153028 153028 CYLINDER 1 20 98110 98110 CREW, fil, 10-32 x 1.00 in., steel, zinc 21 1080835 1080835 WAHER, flat, 0.19 x 0.375 x 1 A, E 0.062 in. Nylon 22 95067 95067 O-RING, EPR, 0.375 x 0.50 x 1 E 0.063 in. 23 ------ 2761 PLUG, CO-plate 1 2 ------ 95020 O-RING, CO-plate 1 E 25 ------ ------ CO-PLATE 1 D

16 A7A Lancing pray Guns Item Part (A7A Circ) Part (A7A M) Description Quantity 26 ------ 973299 PLUG, transducer 1 N 901911 901911 WRENCH, adjustable, module 1 N 152999 152999 WRENCH 1 N ------ 27638 PULLER, CO-plate 1 N 901905 901905 BRUH 1 N 2766 2766 CARD, medical alert, injection 1 NOTE A: Included in 1797 ervice Kit, Ball and eat, A7A. B: Included in 1795 ervice Kit, Piston w/epr eals. C: Included in 1796 ervice Kit, haft eal. D: Optional - ee Table 1. E: Included in 160703 ervice Kit, oft Goods, A7A N: Not hown Note

A7A Lancing pray Guns 17 19 6 6A 6B 20 7 18 17 6C 16 8 9 1 15 2 13 1 11 9 22 10 5 3 10 5 12A 12 12 21 Figure 9 Parts (A7A Circulating Lancing pray Gun)

18 A7A Lancing pray Guns 6A 6B 6 6C 19 20 18 17 7 7 8 15 16 25 2 2 23 9 23 9 26 11 1 22 10 3 10 5 5 12A 12 21 Left View Cross ection Front View Right View Figure 10 Parts (A7A M Lancing pray Gun)

A7A Lancing pray Guns 19 ervice Kits Use these kits to rebuild the spray gun. Refer to the spray gun parts list for kit contents. Part Description Note 17097 CARTRIDGE, packing, stainless steel, EPR 1797 ERVICE KIT, ball and seat, A7A 1796 ERVICE KIT, shaft seal 1795 ERVICE KIT, piston w/epr seals 160703 ERVICE KIT, soft goods, A7A Adhesives, ealants and Lubricants Usethesewhenmakingrepairstothespraygun. Part Description Note 9002 COMPOUND, threadlock, VC-3 90081 ADHEIVE, pipe/thread/hydraulic sealant 1612251 LUBRICANT, O-ring, Parker, 2 oz Options Air Release Valve Use this optional air release valve for quick gun response over long distances. Part Description Note 901028 VALVE, air release, normally closed Pressure Transducer >>> 1 <<< Use this pressure transducer with the itrax spray monitor system. It has a 30 cm (10 ft) armored cable from the transducer to the amplifier, and a 2 cm (8 ft) cable from the amplifier to the spray monitor. Refer to the instruction sheet shipped with the transducer for specifications. Part Description Note 16085 TRANDUCER, 90 degree, 0-600 psi 1611151 TRANDUCER, 160F, 90 degree, INT AMP, 0-1000 psi

20 A7A Lancing pray Guns CO-Plate Use carbide CO-plates with the itrax spray monitor system. Cross-reference your nozzle size with your spray pressure to find the correct CO-plate part number. Contact your Nordson representative for more information on CO-plates for your application.>>> 2 <<< Table 1 CO-Plate election Chart pray Pressures Nozzle ize (GPM) 27 Bar (00 psi) 3 Bar (500 psi) 1 Bar (600 psi) 8 Bar (700 psi) 55 Bar (800 psi) 62 Bar (900 psi) 69 Bar (1000 psi) 76 Bar (1100 psi) 0.015 27707 (015) 27707 (015) 27708 (02) 27708 (02) 27708 (02) 27709 (025) 27709 (025) 27709 (025) 0.03 27709 (025) 27710 (03) 27710 (03) 27711 (0) 27711 (0) 27711 (0) 27712 (05) 27712 (05) 0.0 27710 (03) 27711 (0) 27711 (0) 27712 (05) 27713 (06) 27713 (06) 27713 (06) 2771 (075) 0.06 27712 (05) 27713 (06) 27713 (06) 2771 (075) 2771 (075) 27715 (09) 27716 (105) 27716 (105) 0.075 27713 (06) 2771 (075) 2771 (075) 27715 (09) 27716 (105) 27717 (12) 27718 (1) 27718 (1) 0.09 2771 (075) 27715 (09) 27716 (105) 27717 (12) 27717 (12) 27718 (1) 27718 (1) 27719 (16) 0.12 27716 (105) 27717 (12) 27718 (1) 27719 (16) 27719 (16) 27720 (20) 27720 (20) 27720 (20) 0.1 27717 (12) 27718 (1) 27719 (16) 27719 (16) 27720 (20) 27720 (20) 27721 (25) 27721 (25) 0.20 27719 (16) 27720 (20) 27721 (25) 27721 (25) 27722 (30) 27722 (30) 0.30 27721 (25) 27722 (30) CO-plate part number NOTE: The CO-plate designation is on the front of the CO-plate. 27722 (30) CO-plate designation NOTE: pring range is pressure range of spring used in pressure control system regulator.

A7A Lancing pray Guns 21 Nozzles This gun uses Nordson Tube Lining Cross-Cut nozzles. Refer to ection B7, Tube Lining Nozzles, in the Nordson Nozzle Catalog, or contact your Nordson representative for help in ordering new nozzles for your spray gun. Figure 11 Tube Lining Nozzles

22 A7A Lancing pray Guns

EU DECLARATION of Conformity Product: Automatic Airless pray Applicators, A7A Models: A7A ingle, A7A Dual, A7A Extended Lancing Description: These are all air operated high pressure airless spray guns. The Lancing one listed above is used for lancing into an object to be coated. Applicable Directives: 2006/2/EC Machinery Directive tandards Used for Compliance: EN/IO12100 (2010) EN1953 (2013) Principles: This product has been manufactured according to good engineering practice. The product specified conforms to the directive and standards described above. Quality Certification: DNV - IO9001 Date: 22 June 2017 Hallie mith - Petee Engineering Manager Industrial Coating ystems Amherst, Ohio, UA Nordson Authorized Representative in the EU Person authorized to compile the relevant technical data. Contact: Operations Manager Industrial Coating ystems Nordson Deutschland GmbH Heinrich-Hertz-traBe 2- D-0699 Erkrath Nordson Corporation Westlake, Ohio DOC13023-02

EU DECLARATION of Conformity Product: Automatic Airless pray Applicators, A7A Models: A7A Quattro Modular, A7A Dual Modular, A7A ingle Modular, A7A Extended Lancing with pray Monitor Port Description: These are all air operated high pressure airless spray guns. The Lancing one listed above is used for lancing into an object to be coated. Applicable Directives: 2006/2/EC - Machinery Directive 201/3/EU - ATEX Directive tandards Used for Compliance: EN/IO12100 (2010) EN/IO80079-36 (2016) EN/IO80079-37 (2016) Principles: This product has been manufactured according to good engineering practice. The product specified conforms to the directive and standards described above. Flammable Atmosphere Marking: Ex h IIB T6 Gb Tech File: Notified Body #0518, ira, UK DNV - IO9001 ATEX Quality Notification G Baseefa (UK) Date: 22 June 2017 Hallie mith - Petee Engineering Manager Industrial Coating ystems Amherst, Ohio, UA Nordson Authorized Representative in the EU Person authorized to compile the relevant technical data. Contact: Operations Manager Industrial Coating ystems Nordson Deutschland GmbH Heinrich-Hertz-traBe 2- D-0699 Erkrath Nordson Corporation Westlake, Ohio DOC1302-02