Multiple voltage 45kVA prime power Isuzu engine

Similar documents
Model name XATS 138 XAHS 108 Normal effective Working Pressure Bar(g) 7 8, Psi (g)

The power to evolve. QAS generators

XAS185 KD T4F Product Reference. Product Reference XAT(V)S 186 Jd Stage IV. Portable compressor. Standard Scope of Supply.

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Magnum Mobile Generator MMG75 Specifications

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

RENTAL DIESEL GENERATOR SET

Magnum Mobile Generator MMG75 SS Specifications

Magnum Mobile Generator MMG235 Specifications

Mobile Generator MMG25FHI Specifications

Mobile Generator MMG130 Specifications

Mobile Generator MMG130 Specifications

Specifications. Standard MMG100D** MMG130D** MDG150DF4

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

Magnum Mobile Generator MMG175 Specifications

Mobile Generator MMG75D Specifications

Magnum Mobile Generator MMG330 Specifications

Magnum Mobile Generator MMG125 Specifications

DCA400SSI4F. WhisperWatt 400. MQ POWER Whisperwatt Series. Prime Rating 320 kw (400 kva) Standby Rating 336 kw (420 kva)

10,000 Watt Diesel Generator AGi9P E

13,000 Watt Diesel Generator AGi13P E

SPECIFICATIONS. File _RDA150T3_SA200

60 Hz FEATURES. Exclusively from your Caterpillar dealer

POWERBLOCK GENERATION SYSTEMS

57 KW / 71 KVA POWERED by

customer driven unsurpassed value

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

Model NA 2 L

700 KVA / 550 KW POWERED by

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

640 KW / 800 KVA POWERED by

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

WPS60/S EP Series. Features:

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

MOBILE DIESEL GENERATORS

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

WPS100/S EP Series. Features:

PGDLS352KW 380/ / / / / / / / /

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

PGDLS / / / / / / / / /

DIESEL GENERATOR SETS

WPS350/S EP Series. Features:

Rating Definitions and Conditions

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Diesel generator set QSX15 series engine

28 KW / 28 KVA POWERED by

1000 KW / 1250 KVA POWERED by

WPS150/S EP Series. Features:

45 KW / 55 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMR - 67P 67P 09/05/2016 GMR - 067P

80 KW / 100 KVA POWERED by

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET. 60 Hz FEATURES

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Mobile Diesel. Generators

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

PGDLS / / / / / / / / /

WPS250/S EP Series. Features:

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Model MP150 W W

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva Sound Attenuation: at 7m / 23 ft

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

130 KW / 165 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

70 KW / 90 KVA POWERED by

Rating Definitions and Conditions

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

Rating Definitions and Conditions

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

130 KW / 165 KVA POWERED by

TPD2250H6.3 TECHNICAL DATA

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

Rating Definitions and Conditions

Rental Power 800 kw. Specification sheet. Description. Features. Options

Diesel generator set 6BT5.9 series engine

APD-ULJ250. Standby Power

Spark-ignited generator set

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Diesel generator set QSB7 series engine

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

600 KW / 750 KVA POWERED by

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

Transcription:

XAS185 KD T4F Product Reference QAS 25-45 ID T4F Mobile Generator Standard Scope of Supply The Atlas Copco QAS 25 & QAS 45 ID T4F generators are prime power, multi-voltage, sound attenuated, mobile generators. They are powered by an Isuzu Tier 4 Final, liquid-cooled, four cylinder diesel engine. The units consist of an alternator, diesel engine, cooling system, electrical distribution and control systems - all enclosed within a sound attenuated enclosure fabricated from powder coated galvanealed steel. A broad range of undercarriage formats and options are available. Special attention has been given to the overall product quality, user friendliness, ease of serviceability, and economical operation to ensure best in class total cost of ownership. Available Models QAS 25 ID QAS 45 ID Multiple voltage 25kVA prime power Isuzu engine Multiple voltage 45kVA prime power Isuzu engine Standard Features Benefits Compact, sound attenuated, corrosion resistant enclosure with single point lifting and 110% fluid containment Available as a skid mounted unit with forklift pockets, or on a single axle trailer Heavy Duty alternator with AREP excitation and marine grade protection Extremely durable and environmentally sensitive, designed to be used for everything from the oil patch to special event power Versatility, giving you the flexibility to match your machine to the correct application Start-up power for the most demanding sites with 300% over load starting capabilities DeepSea controller Reliable and intuitive controls for ease of use and diagnostic capabilities Single side servicing with long run filters and 500 hour service intervals Extremely reliable and durable Isuzu 4LE engine with EGR & DOC after-treatment and limited 5 year limited warranty Identical enclosures and maintenance points between both models Heavy duty oil, air and fuel filters extend the maintenance interval to 500 hours for reduced total cost of ownership Reduces maintenance costs with long intervals easy access for mechanics Proven engine platform with high reliability, a simple maintenance free Diesel Oxidization Catalyst only after treatment Reduces stock of service kits and inventory of parts with rental ROI kept in mind Emergency Stop External, recessed emergency stop for increased safety Remote Start / Stop Allows connection as a critical back-up unit via a 2 wire dry contact connection in the distribution panel

Technical Data 1 Generator Units QAS 25 ID QAS 45 ID Rated Prime Power 3Ø kw / kva 20/25 36/45 Rated Standby Power 3Ø kw / kva 22/28 40/50 3Ø Power Factor 0.8 3Ø Voltage In 480V Switch Position (Series Star w/ Neutral) V 480Y/277 Amp Capacity @ 480V A 30 54 3Ø Voltage In 240-208V Switch Position (Parallel Star w/ Neutral) V 240YY/139-208YY Amp Capacity @ 240V A 60 108 Amp Capacity @ 208V A 60 125 Rated Prime Power 1Ø kw / kva 16/16 27/27 1Ø Power Factor 1.0 1Ø Voltage In 120-240V Switch Position (Zig-Zag) V 240/120 Amp Capacity @ 240V A 67 90 Amp Capacity @ 120V A 67 x 2 90 x 2 Alternator (4 Pole, 12 Wire) Leroy Somer LSA 40 M5 LSA 42.3 S5 Excitation AREP Automatic Voltage Regulator (+/- 0.5%) Leroy Somer R438 Insulation Class H Frequency Hz 60 60 Main Breaker - Shunt Trip A 63 125 Power Distribution Terminal Board 5 Wire (L1, L2, L3, N, Ground) Terminal Board Connections Bare Wire Terminals Maximum Terminal Cable Size 350MCM Convenience Receptacles 2 2 x NEMA 5-20R & 2 x 125/250V 50A CS6364 Engine Units QAS 25 ID QAS 45 ID Model Isuzu 4LE2T 4LE2X US EPA Family ESZXL02.2ZTB ESZXL02.2PXB US EPA Tier Tier 4 Final Displacement L 2.18 Cylinders # 4 Continuous Engine Power Output HP (kw) 31.5 (23.5) 59 (44) Gross Engine Power Output HP (kw) 40 (30) 66 (49) Rated Speed RPM 1800 Engine Control ECU Aspiration Turbocharged Turbo w/ Intercooler Engine oil capacity 3 US Gal (L) 1.9 (7.2) Engine coolant capacity US Gal (L) 3 (11.4) 2.11 (8) Maximum Ambient Temperature (@ Sea Level) 4 F ( C) 122 (50) Minimum Starting Temperature (Without cold weather options) F ( C) 14 (-10) 14 (-10) Minimum Starting Temperature (With cold weather kit) 5 F ( C) TBA TBA Electrical System (Negative Ground) V 12 12 Engine Alternator Output A 50 50 Battery Capacity (Cold Cranking Amps) A 650 650 Sound Pressure Level @ 23 (7 m) @ 75% Load 6 db(a) 67 66 Fuel System Units QAS 25 ID QAS 45 ID Fuel Consumption @ 25% load US Gal/hr (L/hr) 0.7 (2.6) 1.2 (4.6) Fuel Consumption @ 50% load US Gal/hr (L/hr) 1.0 (3.8) 1.8 (6.9) Fuel Consumption @ 75% load US Gal/hr (L/hr) 1.4 (5.3) 2.15 (8.1) Fuel Consumption @ 100% load US Gal/hr (L/hr) 1.6 (6.1) 2.76 (10.4) Fuel Type Ultra Low Sulfur Diesel ONLY 7 Fuel Tank Capacity US Gal (L) 73 (274) Fuel Autonomy @ 75% load 8 Hr 46.6 30 1 All ratings are at a reference condition of 0 altitude and 20 C (72 F) 2 Please see receptacle voltage configuration in Power Distribution section on page #5 3 Engine oil to meet CJ-4 (low ash oil) 4 Please see Derate Table for altitude and temperature calculations on page #4 5 Cold start option comes with 120V block heater and 0W40 synthetic engine oil 6 Measured in accordance with ISO 2151 under free field conditions @ 7m distance 7 Engine and emissions require the use of Ultra Low Sulfur Diesel in accordance to ASTM-D975 Grade No.1-D S15 & No.2-D S15 8 Based on 90% volume of fuel tank

QAS 25-45 ID T4F Product Reference Dimensions Trailer Mounted Skid Mounted Weight - Wet (ready to operate) Units QAS25 ID QAS45 ID Trailer Mounted Skid Mounted lbs (Kg) lbs (Kg) 2,396 (1,086) 2,290 (1,040) 2,625 (1,191 2,440 (1,109) Dimensions Trailer Mounted (L x W x H) Skid Mounted (L x W x H) Inches Inches 129.5 x 54 x 66 75 x 34 x 55

Principle Data Alternator The Leroy Somer LSA alternators are designed for heavy duty continuous applications, with marine winding protection and Leroy Somer s AREP excitation system. AREP Excitation for superior motor starting capabilities Marine grade (relative humidity >95%) protection External multi-voltage selector switch (3 position) 4 pole brushless design with single bearing, Class H insulation and IP23 rating Voltage regulation +/- 0.5% Full Load acceptance of prime power rating The AREP system uses 2 independent auxiliary windings located in the main stator to send supply voltage to the AVR: The voltage delivered by the first auxiliary winding H1 is proportional to the alternator output voltage (shunt characteristic). The voltage delivered by the second auxiliary winding H3 is proportional to the current drawn by the alternator and is a function of the applied load (compound characteristic booster effect). The resulting phase-to-phase voltage supplies power to the AVR. This power supply to the AVR power circuit is independent of the voltage sensing measured on the alternator output terminals. Therefore, the excitation current delivered by the AVR to the alternator exciter is independent of any voltage distortions (harmonics) due to the load. The AREP system gives the alternator a high overload capacity (load impact or starting electric motors) and a short-circuit capability (300% - 10 s) in order to provide discriminating protection: the alternator with AREP excitation is shorter than the one with PMG excitation. It is particularly suitable for demanding applications. Performance @ Altitude and High Ambient Conditions When using at altitude and high ambient conditions the engine and alternator will de-rate as per chart below. Temperature C ( F) Height m (Feet) 0 (32) 5 (41) 10 (50) 15 (59) 20 (68) 25 (77) 30 (86) 35 (95) 40 (104) 45 (113) 50 (122) 0 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 500 (1640) 100% 100% 100% 100% 100% 100% 100% 100% 100% 97% 94% 1000 (3280) 100% 100% 100% 100% 100% 100% 100% 100% 100% 97% 94% 1500 (4921) 100% 100% 100% 100% 100% 100% 100% 99% 97% 94% 91% 2000 (6561) 100% 100% 100% 100% 100% 98% 97% 95% 94% 91% 88% 2500 (8202) 100% 100% 100% 100% 100% 95% 94% 92% 91% 88% 86% 3000 (9842) 100% 100% 100% 100% 100% 91% 90% 88% 87% 84% 82% 3500 (11,482) 100% 100% 100% 100% 94% 88% 84% 81% 80% 78% 77% 4000 (13,123) 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% F Rev 1.2 PM# 2958 0106 00

Power Distribution The main power is connected from the alternator through a 3 position voltage selector switch to the main power cubicle. The cubicle incorporates all power distribution, controls, sensing and protection devises. 3 position Voltage Selector Switch (VSS) Current transformer x 3 (1 each leg) Single main breaker w/shunt trip Individual breakers for each receptacle Convenience receptacles located on outside of unit for easy access Terminal board for hard wiring Cam-Lock external quick connect (available as option) External emergency stop switch (recessed) Neutral bonded to Ground with a removable bonding link accessible in the control cubicle Please refer to the chart below for power distribution and voltages. NOTE: All voltages below are subject to change, depending on set point of Fine Voltage Adjustment potentiometer and Voltage Selector Switch. All voltages are adjustable with the Fine Voltage Adjustment potentiometer located on the control panel. Therefore voltage may be different then what is shown in the above table. All voltages should be verified before connection to the unit.

Controller The QAS25 and QAS45 comes equipped with a DeepSea 4510 control module. This is a fully diagnostic ECU controller with large 3 display, that is intuitive and easy to operate with all functions conveniently at your fingertips. The controller also manages the engine ECU operating system, and a number of safety warnings and shut downs on various parameters (listed below). The controller is powered by a main On/Off switch located next to unit. DeepSea 4510 Controller Functionality: Home Page (displayed while running, scrolling every 3seconds) Generator voltage (ph-ph) Generator Page Generator voltage (ph-n) Generator voltage (ph-ph) Generator frequency Load Page Generator current (A) Load ph-n (kw) Total load (kw) Load ph-n (kva) Total Load (kva) Load ph-n (kvar) Total Load (kvar) Power factor ph-n Power factor average Accumulated load (kwh, kvah, kvarh) Event Page Displays the last 15 events Operational Buttons Start button Stop button Automatic mode (external remote start) Up/Down arrows Info Page Model number USB identification number Configured engine type Module s date and time Scheduler setting Engine Page Engine speed Oil pressure Coolant temperature Fuel level Engine battery voltage Engine run time Engine Maintenance due Oil (if configured) Engine Maintenance due Air (if configured) Engine Maintenance due Fuel (if configured) Engine DTC Page This page contains any active Diagnostic Trouble Codes that the engine ECU is currently generating. These alarms are conditions detected by the engine ECU and displayed on the DSE controller. Remote Start/Stop Automatic start stop via 2 wire dry contact connection

Engine Isuzu 4LE2 Isuzu 4LE2 Tier 4 Final, turbo charged, intercooled (QAS 45 only), four-cylinder, liquid-cooled diesel engine provides ample power to operate the generator continuously at full-load. Meets all US EPA, CARB and Environment Canada exhaust legislations with Tier 4 Final compliance. The engine utilizes a Diesel Oxidation Catalyst (DOC) to meet Tier 4 Final emissions. All functionality of the engine is controlled automatically on the DeepSea 4510 controller. The engine has the capability to start the generator at 14 F (-10 C) with standard glow-plug aid. The 73 Gal (274L) fuel tank is sufficiently sized to operate the unit at full-load condition for long run times (see chart on page 2 for specifications). The engine operates on a 12V negative ground electrical system with a 35A charging alternator. The cooling system is suitably designed for continuous operation in ambient conditions up to 122 F (50 C), with canopy door closed. Fuel System A large 73 US Gal (274L) steel fuel tank provides safe diesel storage while eliminating tank corrosion contaminants from being introduced to your fuel system. With integrated fuel water separator and filter, the system is designed to help maintain clean and trouble free diesel supply to the engine for reliable trouble free operation. Pad-lockable diesel fill cap Fuel / Water separator Inline priming pump (w/ filter) Fuel pre-filter Fuel supply pump (w/ strainer) Fuel level sensor Low fuel shut down feature (programmable level) Scheduled maintenance Standard equipped with filters sized and designed to allow 500 hour service intervals under normal operating conditions. Extended time between services reduces down time and total cost of ownership of the unit over its lifetime. 500 Hour Service Interval: Air filter Oil filter Fuel filter Fuel / water separator 1000 Hour Service Interval: Air filter Oil filter Fuel filter Fuel / water separator V-Belt NOTE: Site specific operating conditions such as; poor fuel quality and low load profile may require more frequent service intervals. Enclosure & Frame The generator enclosure is designed for extreme applications to provide superior performance and reliability. The enclosure is fabricated from galvaneal coated polyethylene which is powder coated for corrosion resistance. The enclosure and frame are fully sealed from the radiator to the back of the unit, providing a true 110% containment of all fluids. Galvanealed, powder coated enclosure Heavy duty base frame 110% fluid containment Larger 73 gallon, polyethylene fuel tank Convenient 2 NPT drain at rear of machine to clean out the containment frame Superior level of rain ingress protection and design features Pad-lockable doors and fuel cap Engine fluid plumbed to exterior of frame for ease of service Central lifting point Sound dampening material and design to allow quiet operation at 67 & 66 db(a) respectively

Undercarriage The QAS 25 and QAS 45 are available with two undercarriage alternatives, providing utmost flexibility in installation, site handling or towing. Both the skid frame and the trailer mount the same way and can be interchanged for versatility. Trailer: Single axle Available with hydraulic or electric brakes (optional no brakes available for the QAS 25 only) DOT/Federal MVSS 49CFR571 approved light package and 7 flat blade RV style plug Adjustable height pintle hitch (3 lunette) 15 Rims w/ ST205/75D15 Tires for trailer use Heavy Duty torsion axle rated at 3,500lbs w/ brakes 3,000 w/o brakes Safety chains Screw jack leveling, with pad foot, 3,000 lbs static capacity Single point lifting structure D-Ring Tie down points x4 Skid mounted: Sub-frame skid with integrated forklift pockets Heavy duty design for use in extreme conditions Frame is ¼ wider then machine to reduce damage from forklifts Built-in locations for straps or chains to secure the unit for transport Single point lifting structure Factory Options Available Single axle trailer with hydraulic 2 or 2 5/16 ball hitches (shipped loose) Trailer stabilizer jacks Trailer mounted tool box Cold start kit (120V block heater, 0W40 synthetic engine oil) Battery charger (12V, 6A) Battery isolation switch (lockable) Heavy duty battery (800CCA Optima, Spiralcell AGM, Redtop) Inlet shutdown valve CSA approval External fuel quick connects (3 way valve, located inside of enclosure for spill containment and protection) Cam-Lok quick connections (5 x 400A) LoJack (Stolen Vehicle Recovery System) Telematics system (DSE Webnet System)

Manufacturing & Environmental Standards The QAS 25 & QAS 45 ID T4F are manufactured following stringent ISO 9001 regulations, and by a fully implemented Environmental Management System fulfilling ISO 14001 requirements. Attention has been given to ensure minimum negative impact to the environment. The QAS 25 & QAS 45 ID T4F meets all current US EPA, CARB and Environment Canada exhaust and noise emission directives. Supplied Documentation The unit is delivered with documentation regarding: Hard copies of the Atlas Copco Operators Safety and Instruction Manual, Atlas Copco Parts Book, Isuzu Engine Manual and Parts book, in English as well as electronic copies available on request. Warranty Registration card for engine and Atlas Copco Generators (Units must be registered upon receipt). Warranty Coverage Atlas Copco Generator: Warrantied to be free from defects with regard to material and workmanship for the period of eighteen (18) months from date of shipment from the factory, or twelve (12) months from date of initial startup, whichever occurs first, without limitation of running hours. Isuzu Engine: Warranty from Isuzu Motors America Inc. Unit must be registered directly with Isuzu Motors America upon receipt to be eligible for warranty. Failure to register warranty upon initial startup may cause warranty claim delays or rejection of claim by Isuzu. One (1) years / unlimited hours or up to three (3) years / 3,000 hours of operation (whichever occurs first) * Two (2) years / 2,000 hours of operation (whichever occurs first) on all electrical, fuel system, and turbocharger components** Major Component Limited Warranty (MCW) for five (5) years / 5,000 hours (whichever occurs first) *** *Whichever occurs first. In the absence of a functional hour meter, the engine will be deemed to be in use for eight (8) hours per calendar day commencing from the start of the warranty period. ** Coverage for all electrical and/or electronic (including factory-installed wiring harnesses), fuel system, and turbocharger components are limited to two (2) years or 2000 hours, whichever occurs first. *** Major Component Limited Warranty (MCW) covers the following components only: cylinder block, cylinder head, crankshaft (excluding bearings), camshaft, connecting rods (excluding bushings), flywheel and flywheel housing. Leroy Somer Alternator: Warrantied to be free from defects with regard to material and workmanship for the period of twenty seven (27) months from date of shipment from the factory, or twenty four (24) months from date of initial startup or 10,000 hours, whichever occurs first. Extended Warranty Programs: Programs are available; please contact your local sales representative for more info.