TRANSFORMER SERVICE. ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

Similar documents
ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

ABB Ability Unlocking the true value of smart sensing devices through digitalization

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

When grids get smart ABB your partner for developing Smart Grids solutions

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

Exceeding the standards with MNS

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Overview Overvoltage protection

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Optimized cost of ownership See all the hidden costs without paying any. ABB Title Lorem Ipsum dolor sit Possible Subtitle

Service Fieldbus Engineering and Consulting

Low and medium voltage service. Power Care Customer Support Agreements

ZX-Family Gas-insulated medium voltage switchgear

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Operational Experience with Startup Optimization for Steam Boilers. E.ON s Staudinger, Heyden, Ingolstadt und Zolling Power Plants

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

Product Brochure. Torque-Arm II

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

DODGE MECHANICAL. Grain industry Delivering solutions that solve industry challenges

Western Alberta Transmission Line (WATL) HVDC Project

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Product Brochure. Grip Tight ball bearings

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Learning paths. The path to higher performance ABB UNIVERSITY. ABB University. Learning paths

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

ZX2 Gas-insulated medium voltage switchgear

Dr. Christopher Ganz, ABB, Group Vice President Extending the Industrial Intranet to the Internet of Things, Services, and People (EU6)

Product Brochure. Grip Tight ball bearings

EU MEPS for low voltage electric motors

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Electrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance

Overcoming Motor Driver Heat-Transfer Challenges in Robotic Applications

Product Brochure. E-Z Kleen and Ultra Kleen ball bearings

ABB Ability Performance Optimization for power generation

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

ABB life cycle services Uninterruptible power supplies

EMPAC Metal enclosed capacitor bank for wind applications

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

More power for railway lines Maximum efficiency with proven system behavior

Where flows of liquid, vaporous or gaseous media have to be controlled or shut off

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Marine generators Proven generators for reliable power on board

Product Brochure. Setscrew mounted ball bearings

ABB central inverters PVS to 2091 kva

ABB POWER SYSTEMS CONSULTING

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Optimizing Battery Accuracy for EVs and HEVs

Navigator 550 Sodium wet-section

Simple. Smart. Ready. Whatever your needs, whoever responds.

Life cycle services for protection and control relays Full support from start to finish

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

LV Capacitors QCap-L series Capacitors for power factor correction

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

NEMA MOTORS. Aggregate motors

Baldor-Reliance Food Safe Stainless steel NEMA motors

Fault management for grid automation Advanced fault location solution

MNS PDUpro Intelligent power distribution unit

ABB Services for Low Voltage equipment Your choice, your future

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Hydro Plant Risk Assessment Guide

Unit C of the Scholven Power Plant Automated with System 800xA

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Voltage limiting device HVL

Orchestrate your entire home from a single interface. The beauty of interoperability.

Engineered to Perform. Faster Data Transmission Performance and Reliability Increased Fuel Efficiency Process Optimization CIVIL AEROSPACE

Straight Talk. About the Smart Grid. Introduction

Surge arrester POLIM-H..SD

Product brochure. MagnaGear XTR gear reducers

TwinLine The new system of wall-mounting and floor-standing cabinets

Mahindra REVA case study

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

Service and Rehabilitation Electrical Power Systems

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

2018 AER Social Research Report

Emergency stops Award winning design

ZX-Family Gas-insulated medium voltage switchgear

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Voltage limiting device HVL

Installation and Maintenance Manual CORRUGATED RIVETED GALVANIZED STEEL WATER STORAGE TANKS

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

Guideline for Parallel Grid Exit Point Connection 28/10/2010

Transforming Transforming Advanced transformer control and monitoring with TEC

Surge arrester POLIM-H.. ND

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

Transcription:

TRANSFORMER SERVICE ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

2 ABB ABILIT Y INSPECTION FOR TR ANSFORMERS TXPLORE Use ABB's inspection service to examine the internal structure of your power transformer without having to remove the oil or sending an inspector into confined spaces.

3 TXplore World s first submersible inspection robot TXplore inspection benefits Ability to perform an internal inspection of an oil filled transformer without needing to drain the oil. Safety Eliminates the need for a human to enter harsh and confined-space environments Can reach zones inaccessible to humans Inspection team works from outside the transformer Speed Immediate deployment Significantly reduces outage time (from weeks to days) Simplicity Minimal oil is handled as the TXplore can enter through a top manhole cover No need for a confined-space on-site rescue team Expert support Near real-time images are available to ABB experts Experts from around the world are able to support inspection as it happens ABB Ability platform provides remote access to images Option for customers to receive a comprehensive report with solutions to resolve issues identified by the TXplore Informed decisions The challenge of oil handling and entering the transformer can be a barrier to performing an inspection Guesswork is eliminated with the support of high-quality images Inspections can become more routine The TXplore can assist in emergency inspections of critical transformers when operational issues are detected. TXplore can be deployed as soon as the transformer is de-energized. This additional data supports a more accurate evaluation of the transformer s ability to continue to operate reliably. TXplore can become part of a routine periodic inspection, combined with typical oil samples analyzed for chemistry, dissolved gases and electrical tests such as ratio, power factor, SFRA and others. This evaluation allows the transformer operator to confirm asset readiness/reliability and to use baseline data for future condition comparisons.

4 ABB ABILITY INSPECTION FOR TRANSFORMERS TXPLORE 01 02 01 TXplore in demonstration tank 02 TXplore s perspective of transformer core support structure The need for understanding your asset condition Power transformers are critical to moving electrical energy over long distances. They have very long service lives, typically providing reliable energy transfer for several decades. To ensure a long service life, maintenance must be carried out as the transformer ages and issues arise. The largest transformers are typically filled with mineral oil, which acts as a coolant and provides electrical insulation for the high voltages the transformer must withstand. Both the mineral oil and cellulose insulation break down from the stresses of use and aging. The challenges of traditional inspections In the past, to evaluate if a specific internal component or system required repairs, it was necessary for someone to perform an internal inspection of the transformer. This required bringing oil processing and storage equipment to the site and removing the oil from the transformer. An internal inspection expert would then enter the transformer and perform the inspection. All of this causes a significant outage and considerable expenses for the customer. The internal inspection is quite challenging because spaces are tight and the environment is not humanfriendly. It is also dangerous, as the confined space requires effort to ensure the air inside is breathable. The process can result in the need for extensive processing to remove gas, moisture and re-establish oil impregnation of the insulation system. device through a top manhole cover. This completely eliminates the need to place a human inspector at risk and expose the transformer s internal structure to external contaminants and potential damages from the weight of a human performing an inspection. An on-site operator directs the TXplore using a wireless controller. The TXplore has multiple lights and high-definition cameras that are able to provide photographs and video during the internal inspection. With local communication and support through the ABB Ability platform, transformer experts and customers can watch inspections in near real-time from remote locations. This feature allows ABB to bring the experts in to help with the evaluation and remotely direct operators to look at specific areas in more detail, improving the ability to accurately identify the root cause of a problem. Get connected and make better decisions TXplore inspection can be viewed by our experts via an internet connection. Experts can review information collected during the inspection and develop action plans to improve the reliability of the critical transformer asset. TXplore service can be scheduled to take advantage of a planned outage with little or no increase in the outage duration. ABB can also deploy a team to perform an inspection when unforeseen issues are encountered with same- or next-day response. The ability to perform an internal inspection while the transformer is filled with oil ABB has developed the TXplore to function as a remotely controlled inspection submarine. This allows an inspection of the transformer with minimal to no oil being removed by inserting the

5 Traditional and advanced internal inspection comparison Traditional Disconnect Drain and store oil Connect breathable dry air system and purge transformer 4-10 days Assemble confined-space rescue team Perform human inspection Advanced Remove breathable air system, seal transformer and place under vacuum Reprocess oil and vacuum-fill transformer Disconnect Set time and basic testing 1-2 days Perform TXplore inspection Reconnect and return to service Reconnect and return to service Let s not forget Health, Safety and Environment! No longer necessary for personnel to physically enter transformer Minimized environmental hazards (i.e., oil spillage and soil contamination)

6 ABB ABILITY INSPECTION FOR TRANSFORMERS TXPLORE Frequently asked questions 1. What is the advantage of the TXplore compared to a periscope camera, borescope or other methods used today? Previous devices are very useful for inspecting areas close to the opening on the cover. However, the TXplore system is not limited by distance from the point of entry or the need to maneuver through or around structures inside the transformer. Wireless communications allow it to reach areas far from the opening used for the inspection. 2. We are not expecting the oil to be clear. Is the TXplore proven for different types of oil and different oil conditions? Testing has taken place with both new and service aged oils that is significantly darkened. The images in aged oil are very good, but limited in distance. The unique LED arrangement and illumination help collect good close-up images in dark oil. 3. Is there a chance the TXplore can introduce contamination or cause damage to the transformer being inspected? In our development efforts, we have done extensive testing to make sure that contamination or bubbles are mitigated during the course of an inspection. This has been confirmed through multiple oil samples analyzed after the completion of pilot inspections. The momentum of the robot and control of the speed ensure the device cannot damage transformer structures. 4. Is there a maximum oil viscosity for the TXplore system? The TXplore service can be offered for mineral oil, ester fluids and silicone. It is configured as standard based on the density of mineral oil. Adjustments in the buoyancy control system are required for other density liquids. 5. Can the TXplore inspect a transformer that contains PCB contaminated oil? Yes. For every inspection, an oil analysis must be performed before we enter the transformer. If PCBs are present, there will be an extra cost once the inspection is complete. The extra cost will cover the additional cleaning process of the TXplore. 6. How quickly can ABB respond to a request for an inspection? We can essentially respond as quickly as we can drive or fly to the inspection site pending availability of the TXplore. The entire TXplore system is transportable in two packages, which can be checked as baggage by airlines since each case weighs less than 20 kg (44 lbs). 7. What is the smallest size transformer that the robot will fit? The system is able to fit into any space where a human can fit. Since the TXplore is much smaller [18 cm x 20 cm x 24 cm (7 x 7.9 x 9.3 )] than a human inspector, it can get into much tighter spaces. The final determination will be the specific design of the transformer being inspected. An opening on the top of the transformer must be available for inserting the robot. 8. Can the TXplore inspection be used to accomplish requirements set by NERC/FERC for safe non-destructive inspection methods for substations that are documented with recordable data? Yes. This requirement must be identified during the proposal development. If video documentation is required, an extra charge will be applied to cover the cost of providing a video documenting the internal inspection that can be preserved by the customer or by ABB (for an additional fee).

7 Frequently asked questions 9. How many transformer inspections has the TXplore performed? Orders are being executed on a regular basis in the US. A listing of customers is being developed, as we re just out of the pilot phase and able to quote and book orders. We are now focused on our global rollout strategy to ensure system availability and fast deployments across the Transformer Service network. 10. Can ABB offer the service to other OEMs when they have issues on their test floor? Yes. TRES is able to offer this service for any customer. Our trained operators will always operate the system. In the case of working for other OEMs or equipment manufacturers, they would be expected to provide technical assistance and transformer preparations for the inspection when working with the TRES operator. 11. Will future designs enable inspection when the transformer is energized? Inspecting an energized transformer would put the transformer in great risk as the robot would have a dramatic impact on the electromagnetic fields inside. At this point in time it is not possible to introduce such a device and disturb the fields with an acceptable margin of safety. 12. Can ABB offer demos for interested customers? We are in the process of rolling out the TXplore across our global service network. Transformer Service locations with the TXplore capabilities might be able to offer pilot inspections based on scheduling and availability.

ABB Inc. Transformer Services (TRES) www.abb.com/transformerservice TXplore webpage Additional information We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. 1LAB000654 08.2018