PGDLS / / / / / / / / /

Similar documents
PGDLS352KW 380/ / / / / / / / /

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PGDLS / / / / / / / / /

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGKT / / / / / / / / / / / /

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

WPS60/S EP Series. Features:

WPS20/S EP Series. Features:

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

TPD2250H6.3 TECHNICAL DATA

WPS350/S EP Series. Features:

SIVASA Doosan Series. SD250 Technical Data

WPS250/S EP Series. Features:

13,000 Watt Diesel Generator AGi13P E

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

GMS100C/S EC Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

10,000 Watt Diesel Generator AGi9P E

GMS350C/S EC Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMS200C/S EC Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

Rating Definitions and Conditions

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Model MP150 W W

Model NA 2 L

Rating Definitions and Conditions

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

APD-ULJ250. Standby Power

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Rating Definitions and Conditions

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET. 60 Hz FEATURES

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

DIESEL GENERATOR SET MTU 12V1600 DS660

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SETS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

CGT Stamford UCI 274 E1

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel Generating Set

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

DIESEL GENERATOR SET MTU 10V1600 DS500

RENTAL DIESEL GENERATOR SET

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

APD-NG400. NG Standby Power

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

8,000 Watt Diesel Generator

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENERATOR SET DG00660D5

Transcription:

PGDLS460 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps HCI 544D 380/220 3 416/520 460/575 790.1 FPA35-4002 208/120 3 416/520 460/575 1443.4 FC520X-K DP158LC 220/127 3 416/520 460/575 1364.7 230/132 3 416/520 460/575 1305.4 480/277 3 416/520 460/575 625.5 Ratings: All three Phase generator sets are rated at 0.8 power factor. All single-phase generator sets are rated at 0.8 or 1.0 power factor. POWERGEN reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Prime Power: Available continuously at variable load in lieu of commercially purchased power for an unlimited number of hours per year in accordance with ISO8528-1, and an overload of 10% permitted for one hour in every twelve hours of operation in accordance with ISO 3046-1. Standby Power: Emergency Standby Power in variable load applications in accordance with ISO8528-1 in the event of a utility power failure. No overload available for this service as relevant alternators are peak continuous rated at 27. Overall Dimensions (mm) & Weight (kg) Length:4550 Width:1600 Height: 2250 Weight (kg) :4500

Standard and optional accessories System Standard Optional Air Intake System Cooling System Exhaust System Fuel System Lubrication System Alternator and Electric Switch Control System Silent / Base Start / Charge Standard air filter Air filter overload alarm 50 radiator Low water level alarm Fan and belt guard Discharge valve Stainless steel bellow Residential silencer Complete exhaust pipe Rain cap 8 Hours integrated base fuel tank Standard fuel filter Fuel level gauge Fuel filling cap Fuel hose Standard oil filter Manual oil pump and drain Shunt or self excited Class H insulation H class temperature rise DELIXI MCCB Terminal connection lugs (L1, L2, L3, LN) Comap Nano Plus for 4 cylinders engine Comap InteliLite AMF20 for 6 cylinders or ECU engine 67-72 db(a) @ 3 meters 4mm -6mm Steel base Transportation support leg Single hook Power coating enclosure Anti-vibration mounting between engine /alternator and baseframe Emergency stop mounted outside the canopy Standard color: Ral 3020 Battery with bracket and cables Engine battery charger 3A Mains charger Air prefilter Heavy air filter Antifreeze Water jacket heater Stainless steel silencer Stainless steel exhaust pipe 6 Hours double wall base fuel tank Fuel-water separator Oil level sensor 1 2 Automatic fuel top up system 1 Oil heater Lube oil level indicator Oil temperature indicator 1 PMG or AREP( only) Alternator space heaters PT100 winding temperature sensors Weaver AVR Weaver prolapse transformer F class temperature rise 4 Pole circuit breaker with leakage protection Circuit breaker - 4 pole ABB MCCB MCCB auxiliary contact and shunt tripping device Panel lighting Forklift holes Enclosure color: Trailer for off road or on road Low temperature starting batteries Battery swtich High current charger(10a,20a) Remark: 1 When you need the automatic oil top up system, you have to use the electrical oil level sensor. 2 You can choose either electrical oil level sensor or oil temperature sensor.

Engine Engine specifications Manufacture DOOSAN DAEWOO Engine Model DP158LC Engine Type 4-Cycle, V-type Engine Speed 1800 r.p.m Prime Power 466 kw Standby Power 513 kw Governor Type Electronic Aspiration Turbo charged & intercooled (air to air) Displacement 14.618 L Bore * Stroke 128mm 142mm NO. of Cylinders 8 Compression Ratio 15.0:1 Intake Air Flow 32.3 m3/min Rotation Counter clockwise viewed from flywheel Mean Piston Speed 8.5 m/s Noise Level @3m 67-72 dba Exhaust System Exhaust Gas Flow 93 m3/min Exhaust Gas Temperature 518 Maximum Back Pressure 5.9 kpa Exhaust Pipe Size N/A Air Intake System Max. static pressure after Radiator 0.125 kpa Maximum Intake Air Restriction. With Clean Filter Element 2.16 kpa. With Dirty Filter Element 6.23 kpa Alternator Lubrication System Oil Capacity (Max.- Min.) 22-13 Litres Lubrication Method Fully forced pressure feed type Oil Pump Gear Type Driven by Crank-shaft Gear Maximum oil temperature 120 Fuel System Type Injection System Fuel Feed Pump Capacity Fuel Consumption at 100% Standby Power Fuel Consumption at 100% Prime Power Fuel Consumption at 75% Prime Power Fuel Consumption at 50% Prime Power Fuel Consumption at 25% Prime Power Fuel Tank Capacity Cooling System Direct Injection 315 liters / hr 122.7 Litres/hour 111.5 Litres/hour 83.4 Litres/hour 57.7 Litres/hour 32.3 Litres/hour 6 hours Coolant Capacity- Engine Only 20 Litres Coolant Capacity - with Radiator 79 Litres Standard Thermostat (Modulating) Range 71-85 Maximum for Standby and Prime 103 Coolant Flow Rate 660 liters / min Electric System Electrical System Voltage Battery Connecting Cables Thermal Data Radiated Heat to Ambient Heat Rejection to Coolant Heat Rejection to Exhaust 24V Maintenance-free Auailable 42-46 kw 197-219 kw 413-458 kw 60Hz/1800R.P.M General Data Insulation Class H Power Factor Cos = 0.8 Bearing Single Excitation Shunt / Brushless Altitude 1000 m Ratings Prime Power Standby Power Brand Alternator Number of wires AVR Model PH Voltage(V) kw/kva kw/kva HCI 544D FPA35-4002 450/562 500/625 12 AS440 3 380/220 500/625 538/673 12 KR440 440/550 484/605 AS440 SX440 3 208/120 488/610 420/525 432/540 534/668 455/569 474/2923 425/531 468/585 12 AS440 3 220/127 440/550 480/600 12 SX440 432/540 474/2923 AS440 SX440 3 230/132 440/550 465/581 432/540 484/605 505/631 474/2923 456/570 200/625 12 AS440 3 480/277 475/594 515/644 SX440 432/540 474/2923

Control System Viewable parameters Generator protection Comap Comap InteliLite Comap Nano Plus InteliLite AMF25 AMF20 Phase voltage 3 3 3 Wire voltage 3 3 3 Current Instrument 3 3 Frequency Active power Reactive power Apparent power Power factor Electric energy metering Abnormal voltage Over-current warning Over current protection Over Frequency protection Short circuit protection MCCB MCCB+ MCCB+ Engine figure Engine protection Function Oil pressure Water temperature Fuel level Speed Battery voltage Elapsed time Low oil pressure warning Low oil pressure protection High temperature warning High temperature protection Overspeed warning Overspeed protection Charge fault Remote start-stop AMF Programmable input 3 7 7 Programmable output 6 7 7 Port extension USB Remote monitoring Communication port CAN Start/Stop time control Maintenance tips Fault record Multi-language function Remark: Standard Optional NA

Automatic Transfer Switch (Safety Installation: Detect - Control Switch System) A.T.S - 4 Poles POWERGEN offers not only a changeover switch but also an integrated mains detection and switch system for your 24 Hour Power Protection. The system enables automatic start-up and operation of the generating set in the event of a mains power failure, overvoltage or loss of phase; and also mains automatic re-transfer once it come back. The system has a wide application such as hospital, bank, telecom, air port, broadcasting station and hotels. System Advantages Automatically transfer and re-transfer load from main power to gen-power without operator intervention.operation. (Both automatic and manual) ATS Controller (AMF function), seamless integration with Intelligent 5.0 Available from 32 3200A, better protection for 4 pole switch. Available in standard, bypass isolation and service-entrance configurations. Configurable in open, closed and programmed transition operating modes. Designed to interface seamlessly with POWERGEN generators and switchgear. Drip Proof IP23 Enclosure. Easy Installation: Wall-mounted & Floor standing Comes fully loaded with the technology to do the job. Rated Current Breakey Type A Chinese ABB Socomec 32 B 63 A B B 80 B 100 A B B 125 B B 160 B B B 200 B 250 C B B 300 315 C 400 C C C 630 C D D 800 D D D 1000 D D D 1250 D D D 1600 D D E 2000 E E E 2500 E E E 3200 E E Dimensions : mm A:400 200 500 C:600 400 1200 E:1000 800 1600 B:500 300 650 D:800 600 1400

Controller Standard Parameters Gen phase voltage Generator frequency Engine speed Battery voltage Engine running hours cou t r n e Engine temperature Oil pressure Warning and Shutdown Alarms Low oil pressure High engine temperature Over speed Under speed Start failure Stop failure Emergency stop High/low battery voltage Aux. shutdown alarm Aux. Warning