Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output NPN2 output uto shift input PNP2 output to 5 V output PNP2 output 4 to 2 m output PNP2 output uto shift input PSE3 M Clean series Option Without cable Power supply / Output connection cable Power supply/output connection cable -ZS-28- Note) t the factory, the cable is packed together without being connected. Description Part no. Note Power supply / Output connection cable (2 m) Bracket Sensor connector Front protective cover -ZS-28- -ZS-28-B -ZS-28-C -ZS-27-C -ZS-27-D With M3 x 5L (2 pcs.) pc. With M3 x 8L (2 pcs.) With M3 x 8L (2 pcs.) nit specifications Note ) Nil With unit switching function Note 2) M Fixed SI unit Note ) nder the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note 2) Fixed unit For vacuum/low pressure/low differential pressure/compound pressure: kpa For positive pressure: MPa (for MPa) kpa (for 5 kpa) Option 3 Nil C Option 2 Nil None Bracket B D M3 x 5L Panel Without connector With sensor connector Sensor connector (e-con connector) Note) t the factory, the connector is packed together without being connected. M3 x 5L Bracket Mounting screw (M3 x 8L) Front protective cover Panel Front protective cover Mounting screw (M3 x 8L) Note) These options are unassembled in the factory, but are included with the shipment. 366 Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE3 Specifications Refer to the SMC website for Pressure Switches Precautions (M-E3-3) and Specific Product Precautions (Operation Manual). Model -PSE3 Set (differential) pressure range to kpa to kpa to kpa to MPa 5 to 5 kpa.2 to 2 kpa Note ) Pressure range For compound pressure For vacuum pressure For low pressure For positive pressure For low differential pressure Rated (differential) pressure range to kpa to kpa to k Pa to MPa to 5 kpa to 2k Pa Power supply voltage Current consumption 2 to, Ripple (p-p) % or less (with power supply polarity protection) 5 m or less (Current consumption for sensor is not included.) Sensor input Hysteresis Switch output Maximum load voltage Residual voltage Output protection Response time nti-chattering function Repeatability nalog output Current output Display accuracy (ambient temperature 25 C) Display Indicator light Note 2) uto shift input Enclosure Environment resistance Temperature characteristics Connection Material nalog Output Number of inputs Input protection Maximum load current Voltage output Note 2) ccuracy (to display value) (25 C) Note 2) ccuracy (to display value) (25 C) Operating temperature range Operating humidity range Withstand voltage Insulation resistance to 5 VDC (Input impedance: pprox. MΩ) input With excess voltage protection (up to 26.4 V) Hysteresis mode: Variable, Window comparator mode: Variable NPN or PNP open collector output: 2 outputs 8 m 3 VDC (at NPN output) V or less (with load current of 8 m) With short-circuit protection ms or less Response time selections with anti-chattering function: 2 ms, 6 ms, 64 ms, 28 ms ±% F.S. or less Output voltage: to 5 V (within rated (differential) pressure range),.6 to V (within extension analog output range); Output impedance: pprox. kω Linearity: ±.2% F.S. or less (not including sensor accuracy); Response time: 5 ms or less ±.6% F.S. or less ±.% F.S. or less ±.5% F.S. or less Output current: 4 to 2 m (within rated (differential) pressure range), 2.4 to 4 m (within extension analog output range) ±.5% F.S. ±2 digits or less Maximum load impedance: 3 Ω (2 VDC), 6 Ω (), Minimum load impedance: 5 Ω Linearity: ±.2% F.S. or less (not including sensor accuracy), Response time: 5 ms or less ±.% F.S. or less ±.5% F.S. or less ±2.% F.S. or less ±.5% F.S. ± digit or less 3/2 digit, 7 segment indicator, 2 color display (red/green), Sampling cycle: 5 times/sec OT: Lights up when ON (green), OT2: Lights up when ON (red) No-voltage input (reed or solid state), Low level input: 5 ms or more, Low level:.4v or less IP4 Operating: to 5 C; Stored: to 6 C (with no freezing or condensation) Operating and stored: 35 to 85% RH (with no condensation) VC for min. between live parts and case 5 MΩ or more (measured by 5 VDC mega meter) between live parts and case ±.5% F.S. or less (based on 25 C) Power supply/output connection: 5P connector, Sensor connection: 4P connector Front case: PBT; Rear case: PBT Weight With power supply and output connection cable Without power supply and output connection cable 85 g 3 g Power supply/output connection cable Standards Cleanliness class (ISO class) Oilproof heavy-duty vinyl cable, 5 cores, ø4., 2 m, Conductor area:.2 mm 2 Insulator O.D.:.2 mm CE, L/CS (E26656), RoHS Class 3 Note ) Pressure range can be selected during initial setting. Note 2) uto shift function can not be selected when analog output option is selected. lso, analog output option can not be selected when auto shift function is selected. Note 3) The following units can be selected with unit conversion function: Caution For vacuum/compound pressure: KPa kgf/cm 2 bar psi mmhg inhg For positive/low pressure: MPa kpa kgf/cm 2 bar psi This product is blown with air and double For low differential pressure: KPa mmh2o packed in a Class M3.5 (ISO Class 5) clean room. to 5 V DC nalog output [V] 367 5 C nalog output [m] B Pressure D Differential pressure 4 to 2 m DC 2 4 C Range For vacuum pressure For compound pressure For low pressure For positive pressure Range For low differential pressure B Pressure D Differential pressure Rated pressure range to kpa kpa to kpa to kpa to MPa to 5 kpa Rated differential pressure range to 2 kpa kpa C B kpa kpa kpa MPa 5 kpa D 2 kpa
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE3 Internal Circuit -PSE3 NPN open collector output: 2 outputs, Maximum 3 V, 8 m, Residual voltage: V or less nalog output: to 5 V Output impedance: pprox. kω Brown DC () Gray nalog output Black OT White OT2 Blue DC () -PSE3 NPN open collector output: 2 outputs, Maximum 3 V, 8 m, Residual voltage: V or less nalog output: 4 to 2 m Maximum load impedance: 3 Ω (2 VDC) 6 Ω () Minimum load impedance: 5 Ω Brown DC () Black OT White OT2 Blue DC () Gray nalog output -PSE32 NPN open collector output with auto shift input: 2 outputs, Maximum 3 V, 8 m, Residual voltage: V or less Brown DC () Black OT White OT2 Blue DC () Gray uto-shift input 2 to 2 to 2 to -PSE33 PNP open collector output: 2 outputs, Maximum 8 m, Residual voltage: V or less nalog output: to 5 V Output impedance: pprox. kω Brown DC () Gray nalog output Black OT White OT2 Blue DC () -PSE34 PNP open collector output: 2 outputs, Maximum 8 m, Residual voltage: V or less nalog output: 4 to 2 m Maximum load impedance: 3 Ω (2 VDC) 6 Ω () Minimum load impedance: 5 Ω Brown DC () Black OT White OT2 Blue DC () Gray nalog output -PSE35 PNP open collector output with auto shift input: 2 outputs, Maximum 8 m, Residual voltage: V or less Brown DC () Black OT White OT2 Blue DC () Gray uto-shift input 2 to 2 to 2 to Flow Control Directional Control Valves ir Preparation Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 368 Pressure Switches/ Pressure Sensors
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE3 Dimensions 3 3 3 Power supply / Output connector 2± 2-M3 x.5 Thread depth 4.5.5 3.2 8.2 Sensor connector Power supply / Output connection cable (-ZS-28-) DC () Brown 5 OT Black 4 OT2 White 3 nalog output or auto shift input Gray 2 DC ( ) Blue 2 22 Sensor connector PIN no. 2 3 4 Terminal DC () N.C. DC ( ) IN ( to 5V) With bracket 3 2 5 4.2 4 3.5.6 26.5 46 7.2 22 Bracket 4 35 View With panel mount adapter 34.5 7 24 With panel mount adapter Front protective cover 42.4 34.5 24 8.75 Panel thickness.5 to 6 Front protective cover 369
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE3 Dimensions Panel fitting dimensions Stacking mount of multiple units (n pcs.) (horizontal) Directional Control Valves 3 -.4 pc. mounting 3 -.4 -.4 24 or more 3 24 or more 3 x n pcs. 3.5 x (n pcs. -) 3 x n pcs. 3.5 x (n pcs. -) Stacking mounting of multiple units (n pcs.) (vertical) 3 -.4 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control 37 Pressure Switches/ Pressure Sensors
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE2/-PSE3 Functions uto shift function When there are large fluctuations in the supply pressure, the switch may fail to operate correctly. The auto shift function rectifies such supply pressure fluctuations. It measures the differential pressure at the time of auto shift signal input and uses it as the reference (differential) pressure to correct the set value on the switch. Set value correction by auto shift function Pressure (differential pressure) Supply pressure normal P_ (P_3) ON OFF Switch output (2) uto shift input Hi Lo H_ (H_2) Supply pressure drop Rectified value B -PSE2 ms or more 5 ms or less -PSE3 5 ms or more ms or less Supply pressure increase Rectified value When the auto shift is input, "ooo" will be displayed for approx. second, and the pressure value at that point will be saved as a rectified value "C_5"(CH for -PSE2 and -PSE3) or "C_3" (CH2 to CH4 for -PSE2). Based on the saved rectified values, the set value Note) "P_" to "P_4" (-PSE2) or "P_", "H_", "P_3", and "H_2" (-PSE3) will be rectified. Note) pon reverse output, "n_" to "n_4" (-PSE2) or "n_", "H_", "n_3", and "H_2" (-PSE3) are rectified. Possible set range for auto shift input -PSE2 Set (differential) pressure range Possible set range Compound pressure. to. kpa. to. kpa Vacuum pressure. to. kpa. to. kpa Low pressure. to. kpa. to. kpa to. MPa. to. MPa Positive pressure - - Low differential pressure - - -PSE3 Compound pressure Vacuum pressure Low pressure Set (differential) pressure range. to. kpa. to. kpa to. kpa Possible set range. to. kpa. to. kpa. to. kpa Positive pressure to. MPa. to. MPa 5 to 5 kpa 5 to 5 kpa Low differential pressure.2 to 2. kpa 2. to 2. kpa uto shift zero (-PSE3 only) Basic function of auto shift zero is the same as the auto shift function. The only difference is that assuming the pressure value when an auto shift is input to be "", display value is also rectified. B Rectified value Switch output response time when auto shift is input B uto preset function When auto preset function is selected in the initial setting, it calculates and stores the set value from the measured (differential) pressure. The optimum set value is determined automatically by repeating vacuum and release with the target workpiece several times. dsorption verification Formula for calculating the set value P_ or P_3 -PSE2 P_(P_3)= ( B)/4 -PSE3 C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed. Displayed values of the pressure sensors can be adjusted to within ±5%. Displayed pressure value High Vacuum Max. P_ H_ P_2 Min.B tmosphere ±5%R.D. bsorption Work Work 2 Release Work Work 2 Work n pplied pressure Work n P_2(H_) or P_4(H_2) P_2(P_4) = B ( B)/4 H_(H_2) = ( B)/2 Displayed value at the time of shipment Precise adjustment range of displayed value Note) When the precision indicator setting function is used, the set (differential) pressure value may change ± digit. D Peak/Bottom hold display function This function constantly detects and updates the maximum and minimum values and allows to hold the display value. Series -PSE3 allows the hold value to be reset by pressing and at the same time for one second or more while holding the display value. E Key lock function This function prevents incorrect operations such as accidentally changing the set value. F Reset function This function clears and resets the zero value on the display of measured (differential) pressure. It is possible to rectify within ±7%F.S. from the factory-set value. 37
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE2/-PSE3 Functions G Error indication function Error Error indication function Description name -PSE2 -PSE3 Current exceeding 8 m is applied to switch output (OT). Current exceeding 8 m is applied to switch output OT2. Overcurrent error Residual pressure error pplied pressure error System error uto shift error H Copy function (-PSE2 only) Information that can be copied includes the following: ()Pressure set values (2)Range settings (3)Display units (4)Output modes (5)Response times. When CH is copied to CH2, CH3, and CH4, information of OT in CH will be copied. When CH2, CH3, or CH4 is copied to CH, information of OT in CH2,CH3, or CH4 will be copied only to OT in CH. Note ) When the copy function is used, the regulating pressure value of the copied channel may change ± digit. I Pressure exceeding ±7%F.S. is applied during the zero reset operation. fter displaying the error code for 3 seconds, the switch automatically returns to the measuring mode. Due to individual product differences, the setting range varies ±4 digits. Supply pressure exceeds the maximum set (differential) pressure or upper limit of the display pressure. sensor may not be unconnected or miswired. Or, supply pressure is below the minimum set (differential) pressure or lower limit of the display pressure. The value measured at the time of auto shift input is outside the set (differential) pressure range. fter displaying the error code for approx. second, the switch returns to the measuring mode. Displayed when internal data error has occurred. Displayed when internal data error has occurred. Displayed when internal data error has occurred. Displayed when internal data error has occurred. uto identification function (-PSE2 only) This function automatically identifies the pressure range of the pressure sensor that is connected to the multi-channel pressure sensor monitor, thus eliminating the need of having to reset the range again after replacing the sensor. This function will be activated either when "on" is set in the auto identification mode or when the power is turned back on in that condition. However, this function only works in conjunction with specific pressure sensors (SMC: Series PSE53 ). When other pressure sensors are used, this function will not work. When using other types of pressure sensors, first set the auto identification mode to "of" and then proceed to the range setting. Turning the power back on while in the "on" setting can cause a malfunction. J nti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the supply pressure. This function prevents such momentary drops from being detected as abnormal pressures by changing the response time setting. <Principle> The pressure values measured within the response time that are selected by the user are averaged. By comparing this average pressure value with the set pressure value, switch output (ON/OFF) is determined. Pressure Momentary change Pressure range P- Switch output operation in normal ON conditions. OFF Switch output operation when anti- ON chattering function OFF is on. -PSE2 -PSE3 H_ Possible response time settings 2 ms, 6 ms, 64 ms 2 ms, 6 ms, 64 ms, 28 ms t (ms) t (ms) Time <veraging> <veraging> Time Time K Channel selection function (-PSE2 only) This function displays the measured pressure of any channel. L Channel scan function (-PSE2 only) This function displays measured pressure for each channel in order at approx. 2-second intervals. 372 Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors
Remote Type 2-Color Display Digital Pressure Sensor Controller -PSE2/-PSE3 Functions M Display unit switching function Display units can be switched with this function. nits that can be set vary depending on the range of the pressure sensors connected to the controller. -PSE2 Pressure range For compound pressure For vacuum pressure For low pressure For positive pressure pplicable -PSE533 -PSE53 -PSE53 pressure -PSE543 -PSE54 -PSE532 -PSE54 sensor -PSE563 -PSE56 -PSE56 Set (differential) to kpa to kpa to kpa to MPa pressure range kpa MPa kgf/cm 2 bar psi.2 inhg mmhg -PSE3 Pressure range For compound pressure For vacuum pressure For low pressure For positive pressure For low differential pressure pplicable -PSE533 -PSE53 -PSE53 pressure -PSE543 -PSE54 -PSE532 -PSE54 -PSE564 -PSE55 sensor -PSE563 -PSE56 -PSE56 Set (differential) to kpa to kpa to kpa to MPa 5 to 5 kpa.2 to 2. kpa pressure range kpa.2 MPa kgf/cm 2.2 bar.2 psi.5.2.2.2 inhg mmhg 2 mmh2o 373