Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com
Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Turn off electrical power before installing or servicing fixture in any way. 5. Do not install in wet locations. For dry and damp use only. 6. Turn off electrical power before installing or servicing fixture in any way. 7. To reduce the risk of fire and overheating, make sure all connections are tight. 8. This product is suitable for continuous row mounting. Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Coupez l alimentation électrique avant d installer ou de réparer le luminaire de quelque manière que ce soit. 5. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 6. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 7. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. 8. Ce produit convient au montage en ligne continue. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. LP3.5 Suspended Installation Guide 2 of 12 102-000024 - IG121818-A.0
Table of Contents Luminaire Overview 4 Diagrams 4 Components 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Prepare Ceiling 5 Standard Suspension 5 Connecting Multiple Sections 7 Troubleshooting 10 Wiring Diagrams 11 LP3.5 Suspended Installation Guide 3 of 12 102-000024 - IG121818-A.0
LUMINAIRE OVERVIEW To Building Power Ceiling Fitting / Suspension Bullet J-Box Canopy Power Cord Suspension Cables Cable Gripper Fixture Body Integrated LED Driver STANDARD SUSPENSION COMPONENTS Canopy Assembly Suspension Bullet Suspension Cable Ceiling Fitting Parts (by others) 4 Square or Octagonal Junction Box Wood Screws, #10, 1.5 long Tools Required Drill #2 phillips bit Wire strippers 1/8 Hex Key (for Joining) 5mm Hex Key (for Joining) Quick Specs Input Voltage / Frequency: See product label Rated Power: See product drawing Ambient Temperature: -4 120 F (-20 50 C) Environment: Dry and damp locations LP3.5 Suspended Installation Guide 4 of 12 102-000024 - IG121818-A.0
Installation: Prepare Ceiling Installation: Standard Suspension A C L SAMPLE DRAWING 1 See Final/Record Drawings for Mounting Locations See final/record drawings for mounting locations. Install framing CHECK FOR or strut channels with consideration ELECTRICAL for WIRING: alignment of wiring and suspension mounting locations. MUST 3A Install Ceiling Fitting - Framing Ceiling Fittings may be installed directly into framing with appropriate hardware. A T C L SAMPLE DRAWING 2 Install Canopy J-Box Install 4 square or octagonal Canopy J-Box (sold separately) at power feed location per final/record drawing. CHECK FOR ELECTRICAL WIRING: 3B Install Ceiling Fitting - Toggle Bolts Ceiling Fittings may also be mounted using toggle bolts. MUST T! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching heatsink. 3C Install Ceiling Fitting - 1/4-20 Threaded Rods Ceiling Fittings may also be mounted on 1/4-20 Threaded Rods. LP3.5 Suspended Installation Guide 5 of 12 102-000024 - IG121818-A.0
Installation: Standard Suspension (Cont.) 4 Route Suspension Cable and Attach to Ceiling Route Suspension Cable through Suspension Bullet. Ball end should sit in Suspension Bullet. Screw Suspension Bullet to Ceiling Fitting. 7 Raise Fixture to Suspension Cables Raise fixture to Suspension Cables, and attach fixture by inserting Suspension Cable through Cable Grippers. 6" 5 Cut Suspension Cables to Desired Length 8 Adjust Suspension Cable Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. 6 Connecting Multiple Sections (If Necessary) Please see steps 12 through 25 for directions on connecting multiple sections. 9 Connect High Voltage Wiring Bring wiring and canopy assembly to J-box. Refer to page 11 and final/record drawing to make wiring connections. CAUTION: High Voltage Wire Ensure Power is OFF prior to connecting wiring. LP3.5 Suspended Installation Guide 6 of 12 102-000024 - IG121818-A.0
Installation: Standard Suspension (Cont.)! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. Installation: Connecting Multiple Sections 10A Mount Canopy Bracket to J-Box & Secure Canopy Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. CAUTION: Do not pinch wire connections. 12 Remove Lens Carefully remove lens using suction cup or similar.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. 10B Combo Canopy Installation Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. Attach bullet (with cable) to canopy. CAUTION: Do not pinch wire connections. 13 Remove Heatsink/Reflector Screws Remove heatsink/reflector screws that attach to housing. Set aside. 11 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. 14 Remove Heatsink/Reflector Remove heatsink/reflector and hang over side of fixture. CAUTION: Do not apply excessive tension to wires! LP3.5 Suspended Installation Guide 7 of 12 102-000024 - IG121818-A.0
Installation: Connecting Multiple Sections (Cont.) 15 Align and Join Sections Together Join sections together, as shown, ensuring correct alignment. See final/record drawing for more details. CAUTION: Do not pinch wires while joining! 18 Tighten Set Screws on Outer Corner Tighten set screws to secure outer corner bracket to joined section using a 1/8 hex key. Ensure each section is properly aligned and that there are no gaps between sections. 16 Tighten Joiner Screws Tighten joiner screws, as shown, using a 5mm hex key. Ensure each section is properly aligned, and that there are no gaps between sections. 19 Tighten Joiner Screws on Inner Corner Tighten joiner screws, as shown, using a 5mm hex key. Ensure each section is properly aligned, and that there are no gaps between sections. 17 Mitered Corners: Join Sections Join sections together, as shown, ensuring correct alignment. See final/record drawing for more details. CAUTION: Do not pinch wires while joining! 20 Connect Wiring Between Sections Connect wiring quick-connects between sections. Match each color, as shown. NOTE: Color combinations may vary. LP3.5 Suspended Installation Guide 8 of 12 102-000024 - IG121818-A.0
Installation: Connecting Multiple Sections (Cont.)! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching heatsink. 23 Install Diffuser Shim Install Diffuser Shim at each joined location to prevent light leak between lens sections. Re-install at endcap locations, as necessary. 21 Re-install Heatsink/Reflector Re-install each heatsink/reflector section. CAUTION: Do not pinch wires while reattaching! 24 Re-install Lens Carefully re-install lens, ensuring lens sits properly within Lens Clips. 22 Re-install Heatsink/Reflector Screws Re-install heatsink/reflector screws to attach back to housing. 25 Ensure Lens Sits Properly Between Lens Clips Ensure the lens is properly installed between the Lens Clips. LP3.5 Suspended Installation Guide 9 of 12 102-000024 - IG121818-A.0
Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure all wire connections are made. Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. LED driver may be defective. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TEST. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. LP3.5 Suspended Installation Guide 10 of 12 102-000024 - IG121818-A.0
Wiring Diagrams Traditional On/Off Canopy/Power Feed L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground White Green 0-10V Dimming Canopy/Power Feed L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground White Green DIM- DIM+ 0-10VDC (Dim-) 0-10VDC (Dim+) Grey Purple DMX Canopy/Power Feed AC 50/60Hz L N Line Voltage (Hot) Line Voltage (Neutral) Ground White Green DMX In Shield DMX in - DMX in + DMX in shield DMX in - DMX in + Clear Red DMX Out Shield DMX out - DMX out + DMX out shield DMX out - DMX out + Clear White LP3.5 Suspended Installation Guide 11 of 12 102-000024 - IG121818-A.0
Wiring Diagrams (Cont.) DALI Canopy/Power Feed L Line Voltage (Hot) N AC 50/60Hz Line Voltage (Neutral) Ground White Green DATA + Data + Purple DATA - Data - Grey Canopy/Power Feed Lutron LDE L Line Voltage (Hot) N AC 50/60Hz Line Voltage (Neutral) Ground White Green E1 E1 Purple E2 E2 Grey LP3.5 Suspended Installation Guide 12 of 12 102-000024 - IG121818-A.0