Uninterruptible power supply Supply MEg101.4

Similar documents
Fuse state indicator MEg72. User manual

Output Feeder Monitor Set MEg71

Switching DC Power Supply

EASY CHARGE Weather-resistant fixed mount Battery Charger

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Operating Instructions

362 Clamp Meter. Users Manual

c-go 24V/6A 24V/8A 24V/12A

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

HPSB 2512B v.1.0 HPSB 13,8V/2A/7Ah Buffer, switch mode power supply unit.

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Model 1693, 1694 Switching DC Power Supply

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

EASY CHARGE Waterproof portable Battery Charger

SCXI Power Supply/Float Charger Installation Guide


PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

Sinewave Inverters. SWING 150VA and 300VA. User s manual

362 Clamp Meter. Users Manual

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

MICRO-INVERTER OMNIKSOL M-300

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

Elmdene International Ltd

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

User s Manual. Automatic Switch-Mode Battery Charger

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

OPERATING INSTRUCTION

AWZ 200. AWZ 13,8V/2A/7Ah/L

Mini Multimeter with Non-Contact Voltage Detector (NCV)

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

Solar module user manual Conergy PM 225P-250P

PURE SINE WAVE DC TO AC POWER INVERTER

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Angle sensor AN2 series 30

323/324/325 Clamp Meter

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

IQL Helios Area-/Streetlight. User Manual

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

LEAD ACID BATTERY CHARGER

Autoranging Industrial Multimeter

190M. Medical ScopeMeter. Safety Information

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Battery Charger Series EASY Charger

SLA Battery Capacity Analyzer

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

BM kv Digital Insulation Tester USER MANUAL

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Battery Charger. Series EASY Charger. User s manual

USE AND INSTALLATION HANDBOOK

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Installation manual wall-mounted distributor

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

PSU-S-12V/L-3A/9/FTA/PTC-TR-MC AWZ v.1.0

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

FieldView External Charger. User Guide

POWER SUPPLY aps-412_en 06/16

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Powerware Vdc Extended Battery Cabinet User s Guide.

C3 Operating Instructions

Condensation monitor

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

i400s Calibration Information Introduction

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

DeltaSol AX * *

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Transcription:

Uninterruptible power supply Supply MEg101.4 MEgA Měřící Energetické Aparáty, a.s. 664 31 Česká 390 Czech Republic

Uninterruptible power supply Supply MEg101.4 Uninterruptible power supply MEg101.4 1/ Characteristics The uninterruptible power supply MEg101.4 is designed for feeding the measuring and communication devices with 12 V nominal supply voltage. Its core is a High-frequency voltage converter that converts the supply voltage with high efficiency to the output uninterruptible DC voltage. When the supply voltage is interrupted, the power supply delivers the output DC voltage from the internal supercapacitor for 3 sec at least or if an external a 12 V lead-acid accumulator is connected, it will extend duration of power supply according its capacity. If necessary, the uninterruptible power on the output of the power supply unit can be blocked. The output of the power supply is equipped with overcurrent protection and with a replaceable fuse on the input accessible from outside. The accumulator circuit is also equipped with a replaceable fuses. MEg101.4 also meets requirements of overvoltage category CAT IV / 300 V and therefore is suitable do LV distribution networks. 3

Měřící Energetické Aparáty 2/ Technical data Power supply MEg101.4 input Supply voltage: DC AC, f = 50 Hz Rated voltage: 220 V DC 230 V AC Minimum voltage: 150 V DC 150 V AC Maximum voltage: 300 V DC 300 V AC Rated current: 180 ma DC 180 ma AC Maximum current: 250 ma DC 250 ma AC Input power: Insulation voltage: Overvoltage category: Fuse FU1: 20 W / 45 VA 5.4 kv AC CAT IV / 300 V AC FSK001 / 1 A-T Accumulator Type, rated voltage, capacity: Fuse FU2: Fuse FU3: lead-acid, gel type, 12 V, 1.2 Ah to 24 Ah FSK001 / 2,5 A-T FSK001 / 0,16 A-T Power supply MEg101.4 output Rated output voltage: Output voltage range: Maximum output current, terminals 2, 3: Rated power: 12 V DC 10 V DC to 14 V DC 1.3 A 15 W Uninterrupted power supply period: 3 sec. / without external accumulator connected up to 4 hrs / when 6 Ah accumulator is connected Max. accumulator charging current, AKU, terminals 35, 36: 0.2 A Starting current inrush: 5 A / 3 ms 4

Uninterruptible power supply Supply MEg101.4 Design data Length width height: Weight: 108 90 63 mm 0.4 kg Installation: DIN rail TS 35 Terminal block, max. wire cross-section: 4 mm 2 Operating conditions Rated operating temperature: 22 C Operating temperature range: -20 C to +55 C Operation: Protection rating: interior, with cover panel of terminals outdoor, in waterproof case IP00 Relative humidity: 20 % to 90 % Altitude: Operating position: up to 2 000 m Safety: EN 61010-1:2010 EMC: EN 61326-1:2013 Pollution degree: 2 vertical with ventilation openings on upper side, installation on DIN rail 5

Měřící Energetické Aparáty 3/ Explanation of symbols in user manual for power supply MEg101.4 Danger, electric shock risk Note in documentation / Danger, risk of danger Ground, grounding terminal for RF grounding IP kód Degree of protection provided by enclosure The product is intended for recycling and collection spots Declaration of Conformity European Community 4/ Construction The uninterruptible power Supply MEg101.4 is built in a plastic case made of self-extinguishing polycarbonate. The power supply is installed on the DIN rail TS 35 using upper or lower spring latches. The power supply can be located in the case together with the external accumulator. Global configuration of the MEg101.4 power supply is on Fig. 1. The LED indicator RUN is on the unit's panel, indicating the presence of 12 V DC voltage on the output of the units on terminals with label OUTPUT. The group of terminals POWER with AC or DC supply voltage and the group of OUTPUT terminals with 12 V DC output voltage and blocking are located on the lower part of the unit and their denotation and explanation are given in Tab. 1. The group of AKU terminals is designed for possible connection of an external accumulator and it is found on the upper part of the unit. Maximum cross-section of the connected wire is 4 mm 2. The replaceable input fuse FU1 is in socket under the screwed cover next to the input supply POWER voltage terminals. Both replaceable fuses FU2 and FU3 in the external accumulator circuit are found under the cover located next to the group of AKU terminals. The rated voltage of the external gel gas-tight lead-acid accumulator is 12 V DC and the accumulator can have the capacity up to 24 Ah. Without the external accumulator, the supercapacitors used in the uninterruptible power supply provide power with the voltage drop from 12 V to 10 V for 3 sec at 15 W load. 6

Uninterruptible power supply Supply MEg101.4 Tab. 1: Power supply MEg101.4 terminals Terminal number Terminal denotation Terminal description 1 OUTPUT STOP Uninterruptible output voltage blocking 2 OUTPUT GND Output ground of power supply MEg101.4 3 OUTPUT +12 V Uninterruptible output voltage +12 V DC 14 16 POWER L POWER + POWER N POWER AC phase conductor or DC supply voltage positive pole AC neutral conductor or DC supply voltage negative pole 18 POWER RF grounding 35 AKU + Positive pole of the 12 V lead-acid accumulator 36 AKU Negative pole of the 12 V lead-acid accumulator Fig. 1: Power supply MEg101.4 unit FU2 FU3 FU1 On the left side of the MEg101.4 power supply unit, there is a rating label with detailed information about the power supply, see the example in Fig. 2. 7

Měřící Energetické Aparáty Obr. 2: MEg101.4 rating label example Supply MEg101.4 Power: U n =230V, (150-300) V, f n=50hz U n=220v, (150-300) V I n =180mA, I max =250mA Output: U n = 12V, (10-14)V I total=1,5 A (term.2-3 and 36-35) I =0,2 A (term.36-35) max Made in Czech Republic 5/ Safety information Maximum attention must be paid to this information Warnings draw attention to the facts, constituting safety risks to the operator. Cautions indicate conditions and facts that may cause damage to the uninterruptible power supply MEg101.4. The operator engaged in installation of the power supply MEg101.4, commissioning, maintenance and dismantling must be equipped with personal protective equipment against electrical shock and must use other protection devices as well. The operator engaged in installation of the power supply MEg101.4, commissioning, maintenance and disassembly must have qualifications for work near dangerous voltages. The operator must also be trained to administer first aid. The power supply MEg101.4 may be operated by skilled personnel only. The power supply MEg101.4 may be connected to supply by permanent maximum voltages 300 V AC and 300 V DC, otherwise there is a risk of electrical injury. It is necessary to incorporate circuit breakers in the circuits of the power supply MEg101.4 with respect to the type of supply voltage, see Fig. 4. Repairs of the power supply MEg101.4 may only be carried out by the manufacturer or service organizations authorized by the manufacturer. The replacement of FU1 fuse for AC or DC supply voltage may be carried out only with the supply voltage switched off. When connecting an external 12 V battery the terminals must not to be short circuited and as the last the inlet connects to positive pole of the supply source. 8

Uninterruptible power supply Supply MEg101.4 6/ Installation and putting in operation If the uninterruptible power supply MEg101.4 is used in ways other than originally intended, the protection provided by the power supply may be impaired. The uninterruptible power supply MEg101.4 is a Class A product designed for industrial environments. It may cause radio interference in other environments. The power supply MEg101.4 unit is placed only in vertical position and is always installed on DIN rail (35 mm) in the case or under the terminal cover panel so that protection rating, fire resistance, mechanical impact resistance for the required environment can be reached. Due to protection against electrical injury and mechanical impact resistance improvement require overlapping the terminals cover by the cover panel. The uninterruptible power supply MEg101.4 may only be installed by the person authorized to work with input voltage and equipped with personal protection equipment against electrical injury and familiarized with the instruction manual. The denotation of supply terminals in the POWER L and N section applies to AC mains supply and the denotation + and applies to DC supply voltage. The power supply MEg101.4s with the external lead-acid accumulator is delivered unconnected. When handling the accumulator, its output terminals must not be short-circuited. When installing the MEg101.4 set with the external accumulator, the correct polarity must be respected. In case of incorrect connection of the accumulator to the power supply terminals (terminal 35 is + pole, terminal 36 is pole), the fuse FU2 (2.5 A) will burn out. In case of short-circuit of the accumulator terminals (terminals 35 and 36) the fuse FU3 (0.16 A) will burn out. Regardless of the power supply voltage direction or way of grounding (DC or AC, none or one grounded pole), it is neccessary to connect both supplying wires via fuse switch-disconnector according to Fig. 4. It is also neccessary to place the fuse switch-disconnector as close as possible and as easily reachable as possible. The uninterruptible power supply MEg101.4 is installed always on the DIN rail TS 35. The MEg101.4 is always in vertical position with ventilation openings on upper side and the inscription on the unit's panel is readable from left to right, see Fig. 3. Power supply MEg101.4 wiring is in Fig. 4. 9

Měřící Energetické Aparáty Fig. 3: Example of installation source unit in vertical position to box with DIN rail The power supply terminal (18) for RF grounding must be connected to the grounding system in the power supply installation site. Based on the type of power supply, AC or DC supply voltage is brought to terminals (14) and (16). The power supply MEg101.4 can be fed by AC voltage ranging from 150 V AC to 300 V AC. The power supply MEg101.4 can be fed by DC voltage ranging from 150 V DC to 300 V DC. When the uninterruptible power supply MEg101.4 is used for feeding external devices, the uninterruptible output voltage is +12 V / max. 1.3 A is available at terminals (2) and (3). The terminal (1) connected with terminal (2) is used for blocking the uninterruptible supply voltage. In this way, it is possible to block unnecessary discharging of the external accumulator, e.g. during functional checks and inspections. After connection of the input supply voltage, the LED indicator RUN on the power supply panel is lit and the output DC voltage U nom = +12 V DC is available on the output and internal supercapacitors and also alternatively the external lead-acid accumulator connected are charged at the same time. When the supply voltage is interrupted, the power supply unit is fed by DC output voltage ranging from 10 V to 14 V for the period of 10

Uninterruptible power supply Supply MEg101.4 uninterruptible power supply. The termination of uninterruptible power supply is indicated by the LED indicator RUN turned off. Renewal of the uninterruptible power supply is started up also by short-term renewal of the input supply voltage. Fig. 4: Power supply MEg101.4 wiring Lead-acid Accu 12V, max.24ah FU2 FU3 FU1 STOP 12VDC +12V DC Power +/L -/N 150V DC to 300V DC 150V AC to 300V AC,50Hz The discharged accumulator with capacity 6 Ah is fully charged in 48 hours even with maximum load of the power supply. The uninterruptible power supply MEg101.4 has an internal power source (supercapacitors) so it is not permitted to remove its cover when it is in operation. 11

Měřící Energetické Aparáty 7/ Maintenance requirements The repairs of the power supply MEg101.4 during the warranty period may only be carried out by the manufacturer's skilled and trained personnel or by the manufacturer's service organizations. The contact to the manufacturer's service is indicated on the website www.e-mega.cz. The power supply MEg101.4 unit may not be exposed to chemicals. The power supply MEg101.4 may be transported in its original container only. The power supply MEg101.4 has no requirements for forced cooling. When polluted, the power supply unit is carefully cleaned with a damp cloth without using cleaning agents. When the power supply MEg101.4 with external lead-acid accumulator is stored for a long time or the input voltage is not connected, it is necessary to charge the battery, preferably through the MEg101.4 power supply, after 1 year at the latest. The minimum charging time for the 6 Ah accumulator is 48 hours. When an external lead-acid accumulator with a different capacity is connected, the charging time will be modified proportionally. It is recommended to perform preventive inspections after every 4 years of operation. The preventive inspection includes: checking the unit for mechanical integrity, checking the level of output DC voltage, checking the output DC voltage blocking by connecting the power supply contacts (1) and (2) with disconnected supply voltage, checking the capacity of the external lead-acid accumulator or preventive replacement of the accumulator. When the power supply is used without the external accumulator connected, check the function of the uninterruptible power supply from internal supercapacitors in such a way that the power supply is connected for 10 minutes to the supply voltage and then the time of uninterruptible power supply is checked according to loading level, see Tab. 2. 12

Uninterruptible power supply Supply MEg101.4 Tab. 2: Informative periods of uninterruptible power supply without connected external accumulator with voltage drop to 10 V P [W] 10 15 t [sec] 8 4 8/ Disposal When the power supply MEg101.4 service life is over, have the unit recycled in waste disposal sites according to rules for electronic waste disposal. The power supply set may include the accumulator as well. 9/ Contents of the set Basic set Uninterruptible power supply MEg101.4 1 pc fuse FU1 type FSK 001 / 1 A-T 1 pc fuse FU2 type FSK 001 / 2,5 A-T 1 pc fuse FU3 type FSK 001 / 0,16 A-T CD with user description Optional parts of the set DIN rail TS 35 with accessories n pc fuse FU1 type FSK 001 / 1 A-T n pc fuse FU2 fuse type FSK 001 / 2,5 A-T n pc fuse FU3 type FSK 001 / 0,16 A-T 2-pole disconnector OPVA 10-2 13

Měřící Energetické Aparáty 10/ Warranty It is not permitted to open the power supply MEg101.4 during warranty period. The power supply MEg101.4 design is covered by a 24-month warranty from the date of purchase, however, 30 months after removal from the manufacturer storage at longest. Defects originating during this period as a demonstrable result of defective design, manufacturing or using improper material will be repaired free of charge by the manufacturer or his service organization The external lead-acid accumulator delivered in the MEg101.4 power supply set is covered with a warranty in compliance with delivery terms of the accumulator supplier. During the warranty period, after 1 year at the latest, it is necessary to connect the power supply with the external lead-acid accumulator to the rated supply voltage for 48 hours at least. The warranty becomes invalid if the user carries out unauthorized modifications or changes on the power supply if he connects the power supply incorrectly or if operated contrary to technical conditions and user description. The defects on the power supply and its accessories originating during the warranty period shall be claimed by the user to the manufacturer or to the service organization authorized by the manufacturer. The manufacturer bears in any case no responsibility for subsequent damages caused by using the MEg101.4 power supply. No responsibility which would exceed the price of the power supply follows for the manufacturer from this guarantee. 11/ Manufacturer MEgA Měřící Energetické Aparáty, a.s. 664 31 Česká 390, Czech Republic tel. +420 545 214 988 e-mail: mega@e-mega.cz www.e-mega.cz 14

Uninterruptible power supply Supply MEg101.4 MEgA Měřící Energetické Aparáty, a.s. 664 31 Česká 390 Czech Republic www.e-mega.cz Edition: 7/2015