LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

Test Sample Description Catalog Number: Description:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

LED Black Housing High Output Remote Capable

Test Sample Description Catalog Number: Description:

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

PHONE: (303) FAX: (303) WEBSITE:

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

Calibration Due Date Chroma Programmable AC Source 61604

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

Lisun Electronics Inc. Tel:+86(21)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Lisun Electronics Inc. Tel:+86(21)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Photometric Indoor Test Report

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

Integrating Sphere Test Report

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LIGHT EFFICIENT DESIGN

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

Integrating Sphere Test Report

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Integrating Sphere Test Report

LIGHT EFFICIENT DESIGN, LLC

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

Lighting Sciences

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Transcription:

Report of Test LLIA000785-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 11408 lm 112.1 W 101.8 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135, USA Page 1 of 5

Legend: All planes - Solid (cd) INTENSITY SUMMARY (cd) All Flux Flux Gamma Planes (lm) Gamma C0 (lm) 90 0 41707 90 134 5 38626 3253 95 88 98 10 25696 100 49 15 14857 4142 105 12 18 20 8002 110 1 25 3130 1619 115 0 1 15000 30 1433 120 0 35 866 570 125 0 0 60 40 644 130 0 45 543 429 135 0 0 50 501 140 0 55 448 398 145 0 0 30000 60 370 150 0 65 307 317 155 0 0 70 310 160 0 75 317 332 165 0 0 80 300 170 0 85 203 233 175 0 0 30 90 134 180 0 45000 (Rotational symmetry) ZONAL FLUX AND PERCENTAGES AVERAGE LUMINANCE (cd / m^2) Zone Flux (lm) %Lamp %Luminaire Gamma C0 0-30 9013 N / A 79.0 45.0 42310 0-40 9584 N / A 84.0 55.0 43073 0-60 10410 N / A 91.3 65.0 40036 0-90 11292 N / A 99.0 75.0 67524 40-90 1708 N / A 15.0 85.0 128141 60-90 881 N / A 7.7 90-180 116 N / A 1.0 0-180 11408 N / A 100.0 Total Light Output = 11,408 lm Signed: Spacing Criterion: 0-180 0.4 Spacing Criterion: 90-270 0.4 Michael L. Grather Date of test 31-May-2017 Authorized Signatory Date of report 2-Jun-2017 Page 2 of 5

Intensity (cd) and Flux (lm) data Gamma Intensity Flux Gamma Intensity Flux 0.0 41707 90.0 134 2.5 41113 92.5 106 5.0 38626 3253 95.0 88 7.5 33062 97.5 72 98 10.0 25696 100.0 49 12.5 19658 102.5 27 15.0 14857 4142 105.0 12 17.5 11157 107.5 4 18 20.0 8002 110.0 1 22.5 5146 112.5 1 25.0 3130 1619 115.0 0 27.5 2017 117.5 0 1 30.0 1433 120.0 0 32.5 1095 122.5 0 35.0 866 570 125.0 0 37.5 725 127.5 0 0 40.0 644 130.0 0 42.5 601 132.5 0 45.0 543 429 135.0 0 47.5 511 137.5 0 0 50.0 501 140.0 0 52.5 485 142.5 0 55.0 448 398 145.0 0 57.5 407 147.5 0 0 60.0 370 150.0 0 62.5 334 152.5 0 65.0 307 317 155.0 0 67.5 302 157.5 0 0 70.0 310 160.0 0 72.5 317 162.5 0 75.0 317 332 165.0 0 77.5 314 167.5 0 0 80.0 300 170.0 0 82.5 266 172.5 0 85.0 203 233 175.0 0 87.5 167 177.5 0 0 90.0 134 180.0 0 Page 3 of 5

Test Number: LLIA000785 003 Catalog Number: GTSOL5498 G2 HO SV BR 50D One Mean Well HLG 150H 24B LED driver. Coefficients Of Utilization Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99 1 113 109 107 104 110 107 105 102 103 101 99 99 97 96 95 94 93 91 2 107 102 98 94 105 100 97 93 97 94 91 94 91 89 91 89 87 85 3 102 96 91 87 100 95 90 87 92 88 85 89 86 84 87 84 82 81 4 98 91 86 82 96 90 85 81 88 84 80 86 82 79 84 81 78 77 5 94 87 81 77 93 86 81 77 84 80 76 82 78 76 81 77 75 73 6 91 83 78 74 90 82 77 74 81 76 73 79 75 72 78 74 72 70 7 88 80 74 71 87 79 74 70 78 73 70 76 73 70 75 72 69 68 8 85 77 71 68 84 76 71 68 75 71 67 74 70 67 73 69 67 66 9 82 74 69 66 81 73 69 65 73 68 65 72 68 65 71 67 65 63 10 80 72 67 63 79 71 66 63 70 66 63 70 66 63 69 65 63 62 For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic assumptions: 1) Room surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance. Circle of Light Plot Height(ft) Beam Width (across 50% Nadir Illum) Illuminance at Nadir (fc) 0 180 90 270 6.0 1158.5 2.42 2.42 8.0 651.7 3.22 3.22 10.0 417.1 4.03 4.03 12.0 289.6 4.84 4.84 14.0 212.8 5.64 5.64 16.0 162.9 6.45 6.45 Page 4 of 5

Test Distance 9.5 m Test Temperature 25.2 C Notes The laboratory has not participated in the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. Tested in accordance with the applicable sections of publications: IES LM-79-08 (Sec. 12), IES LM-16-93, IES LM-58-13, CIE 13.3:1995, CIE 15:2004, ANSI C78.377:2015, ANSI C82.77-10:2014. The luminous intensity values, and other derived quantities, contained in this report are based on the absolute data, as measured. Prorating the performance of the sample for the use of other component combinations (such as lamp / LED / Ballast / driver), or for use in different environmental conditions than that tested, may produce erroneous results. This report is free of erasures and corrections. Photometric intensity values are reported using the CIE Gamma coordinate system as defined in CIE publication number 121. This report may contain data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government. 02-Jun-17 15:44:34 REPORT program version: 3.808a Page 5 of 5