Technical Requirements. Test criteria for the fabrication of highly acid resistant glass-lined steel piping and valves. 850p 800

Similar documents
GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

Broetje-Automation Company Standard Structural component specification for welded parts

B38 01/12. Installation and Operating Instructions Combi Gauges for Rail Cars Models Rg Fz, RChg Fz, DRg Fz, DRChg Fz. Contents

RFID114. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes or street light charging points.

SITRANS P measuring instruments for pressure

WEDGE & SLAB GATE VALVES

PTFE Lined Pipe and Fittings

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

PIPE LOG BOOK. Project no:... Project:... Construction section:... On behalf of:... Commissioned by:... Order no:... Date:... Construction period:...

Series MNK-X, MNK-XB, SCK-X Frame-mounted Chemical Vortex Pumps

Ductile Iron. Fittings and Accessories for pressure pipelines. 1 st issue

Weld-Ring Gaskets. Weld-Ring Gaskets. Absolutely leak proof gasketing. Characteristics and Advantages Page 1. Hollow Lip Weld-Ring Gaskets Page 2

SUPPLEMENTARY INSTALLATION AND OPERATING MANUAL Translation of the original manual. Series MNK-X, MNK-XB, SCK-X Frame-mounted Chemical Vortex Pumps

Profile Gaskets. Profile Gaskets with Covering Layers. Grooved Gaskets with Standard Profile. Grooved Gaskets with Convex Profile.

Grooved gaskets. Types of gaskets

HYGIENIC TUBE & PROCESS COMPONENTS DIN 11866

Long Face to Face. Bonded Liner Butterfly Valve Mono Flanged Type (Long) Series 130. Document : S130 Revision : 3 Year : 2014

Garlock Butterfly Valves Technical Catalog Trusted throughout the chemical, petrochemical & many other industries

Mono Flanged Type Long Face to Face

FlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Short Face to Face. Bonded Liner Butterfly Valve Mono Flanged Type (Short) Series 120. Document : S120 Revision : 2 Year : 2014

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

FITTINGS AND VALVES. Novo Plug-in System The Intelligent Solution. The thrust-resisting joint system for valves and fittings with Düker etec enamel

AIR RESERVOIRS. Product Catalogue

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

UNIJOINT is a company of. UNIJOINT Eurocoup Flange Adaptors & Couplings

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

product catalogue Q215 ISO 9001:2008 certified

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Bonded Liner Butterfly Valve Double Flanged Type Series 150

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Horizontal Pre-Piped Bladder Tanks with Proportioner

Declaration of Conformity as per Directive 97/23/EC

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Vertical Pre-Piped Bladder Tanks with Proportioner

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Cylindrical Valves SCP Series

CertRom. BUCHAREST, S5 Calea 13 Septembrie 231A; Ph: , Fax: ;

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

Ford Fabricated Steel Products

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Flanged Ball Valves KHBF / KHMF / KHMFF

NEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE. Industrial hoses, with and without fabric lining

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

TYPE APPROVAL CERTIFICATE

Butterfly valves. Introduction. Made of ductile cast iron

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

Expanded Graphite SIGRAFLEX UNIVERSALPRO

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Operating Instruction for Flowmonitor. Model: DF-WM

h Technical Product Data FW Pressure Pipe Systems

Thermowell For sanitary applications Model TW22

Worcester Controls F819/829. Full Bore Firesafe Flanged Ball Valves

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Assembly and operating Instructions. Bypass Flow Meter DST

THOMAS. Unifit Premier Series. Couplings & Flange Adaptors Non Restrained Products PIPE PRODUCTS

RMA-monoblock-insulating joints

Strainer. ARI-Strainer. ARI-Strainer Y-pattern with flanges. ARI-Strainer Y-pattern with flanges. ARI-Strainer Y-pattern with butt weld ends

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p.

Operating Instructions

Process Inline Filter Protective filter PLF2-9HF

Diaphragm Valve, Metal

Safety Equipment for Hydraulic Accumulators

Data sheet: S3 Bar and structural products Profiles, dimensions & tolerances. Introduction

Plastic-Lined Piping Systems The Next Generation of Safety, Quality and Innovation

Technical Manual. Register 10 CONTENTS - ASG

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Insulating joint IK. Insulating joint IK. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

P.E.D. 2014/68/EU Butterfly Valves Series SL, SLT and SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

Operating Instructions Inline Detonation Flame Arrester and

EU Declaration of conformity

Broad Base. Best Solutions.

OPTIMASS 2000 Technical Datasheet

Ex m Solenoid Operator Type 0519

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

SUITABLE FOR EXAMPLES OF USE APPROVALS. TS EC type examination. Requirements AD 2000 Data sheet A2 DIN EN ISO PED 2014/68/EU

SUITABLE FOR EXAMPLES OF USE APPROVALS. Type approval Deutsche Bahn. Requirements. AD 2000 Data sheet A2 DIN EN ISO PED 2014/68/EU

Expanded Graphite. TALuft SIGRAFLEX HOCHDRUCKPRO

ERHARD is a company of. ERHARD ECLI butterfly valve

SUITABLE FOR EXAMPLES OF USE APPROVALS. Requirements PED 2014/68/EU

Flow Measurement SITRANS F C

THE FUTURE NEEDS STEEL

Ball Valves SBV Series full-port

High adaptability and tightness even at low surface loads

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

TECHNICAL GUIDE. EBP from 0,07 to 100 bars

REPAMAX. Versatile Stainless Steel Coupling. Versatile Stainless Steel. By Krausz Wide-Range Couplings. Joins as a coupling. Repairs as a clamp.

Materials : Carbon steel or stainless steel

Transcription:

GLASS LINING TECHNOLOGIES Technical Requirements Test criteria for the fabrication of highly acid resistant glass-lined steel piping and valves email850p email800

Contents Certifications Safety through approved quality Certifications Page 3 Fabrication Page 4 Technical requirements for fabrication Page 6 Enamel and enamel-tests / External protection Page 7 Material and quality certificates for raw materials Page 8 Pressure Equipment Directive 97/23/EG Page 9 Highest standards are set by the pharmaceutical and chemical industry for safety through operation and production as well as in maintenance and servicing. Technical enamels of Düker can meet all these demands at all levels. A quality management system in accordance with ISO 9001 was already incorporated in the Düker quality policy in 1994. All the glass lined Division Works at all locations have been successfully audited by the appropriate German authorities and have been awarded the TÜV Certificate. The production of pressure parts according to the ASME-Code (American Society of Mechanical Engineers) calls for specially defined materials, welding processes and documentation. Highly efficient quality management with dedicated employees ensures documented safety at all levels. Operating Instructions Excerpt from our installation instructions for glass lined pipework Page 10 has implemented and maintains an Occupational Health and Safety Management System. has implemented and maintains an Energy Management System. made to specification, ductile iron shut-off valves and pressure pipe fittings, highly acid-resistant glass-lined components. made to specification. BS OHSAS 18001 : 2007 ISO 50001 : 2011 Certificate registration no. Date of certification 511876 BSOH 2015-05-12 2018-05-11 2015-05-12 Certificate registration no. 511876 EMSt 2015-06-04 2018-06-03 Date of certification 2015-05-12 has implemented and maintains an Environmental Management System. has implemented and maintains a Quality Management System. made to specification, ductile iron shut-off valves and pressure pipe fittings, highly acid-resistant glass-lined components. made to specification, ductile iron shut-off valves and pressure pipe fittings, highly acid-resistant glass-lined components. ISO 14001 : 2004 + Cor 1 : 2009 ISO 9001 : 2008 Certificate registration no. 511876 UM 2015-07-10 2018-07-09 Date of certification 2015-05-12 Certificate registration no. 511876 QM08 2015-03-24 2018-03-23 Date of certification 2015-03-21 2 3

Fabrication Düker only uses pipe material in grades of steel suitable for glass-lining with all necessary quality certificates. The stub flanges and pipe components are joined on automatic welding machines. The root is laid by inert gas-shielded tungsten arc welding (TIG) and the final pass provided by inert gas metal arc welding (MAG). Inert gas welding is a reliable and fast method particularly for smaller nominal diameters. Submerged arc-welding is particularly suitable for larger nominal diameters. It guarantees extremely low weld seam porosity as well as fast welding. Düker welds one final pass on both the inside and outside. The dried parts are fired in electric or gas heated furnaces at temperatures between 800 C (1472 F) and 900 C (1652 F). This firing is repeated six to seven times until the glass-lining will have the required thickness. Apart from mechanical gripping at a high firing temperature a chemical reaction takes place which leads to positive adherence of metal and glass (composite material) Special parts are produced on semi-automatic welding machines. The root, fill and pass are welded in two to three welding operations by this method. A first visual inspection takes place immediately after glasslining. All glasslined parts are subject to a spark test to identify any porosity. All weld seams are machined and slurred. Absolutely non-porous and clean round weld seams are essential for glass-lining. Before glass-lining, each piece is checked for exact dimensional accuracy. Other test criteria include measuring the thickness of the glass coating and testing the angularity and plane parallelism. The tested glass-lined parts are provided with a quality seal by the QA-department. Two ground coats of glass are applied to the previously annealed and sandblasted parts. These serve as the bonding layer between the base material and the cover-lining. The enamel is applied by spraying, dipping or pouring. Glass lined products from Düker have excellent characteristics against corrosion resistance, wearing and diffusion resistance. 4 5

Technical Requirements for Fabrication Enamel & Enamel Tests / External Protection 1. Materials Düker only uses the materials listed in DIN EN ISO 28721-4 with quality certificates in accordance with the AD Directives, Series W, for producing highly acid resistant glass-lined pipeline components. In case parts are subject to an acceptance procedure the material has to be marked prior to cutting to size. Our workers have the approval for restamping granted by the appropriate German authorities (TÜV). 2. Welding Düker has its own technique for melting the mixture of quartz, minerals and metal oxides into a glass frit at a temperature of 1.400 ºC (2552 F). In this way samples are constantly analysed and compared with given standards in order to guarantee a consistent quality. According to following standards the tests are going to be carried out on enamelled samples: Acid resistance: DIN EN ISO 28706-2 Alkali resistance: DIN EN ISO 28706-4 Thermal shock: DIN EN ISO 13807 All weld seams are produced in two final passes. Our welding methods comply by AD2000 leaflet HPO and DIN EN ISO 3834-2. Our qualified welders have valid test certificates issued by the appropriate German authorities (TÜV). These must be renewed every two years. 3. Tests Welds are subject to a non-destructive test according to AD 2000, HP 100 R, Tafel 3. The spark test follows after glass-lining. Since pore-free glass-lining automatically calls for a perfect surface on the weld seam, these tests also serve as a substitute for the water pressure test. Our QA-department subjects every glass-lined part to the following tests: 1. Preliminary spark test of 20.000 V. 2. Check on lining thickness (especially on all convex radii) according to DIN EN ISO 28721-4. 3. Dimension and tolerance check according to DIN 2 873. 4. Visual examination of surface condition by refraction. 5. Final 12.000 V spark test and visual recheck prior to despatch. 4. Certificates If required by the customer, we supply glass-lined pipe parts and fittings with Works Certificates (Certificate 2.2 to EN 10 204). The type of certificate demanded for special conditions ( i.e. highly toxic media, large nominal dia meters and higher pressures) is to be agreed when ordering. After glass-lining all pieces are sandblasted and, unless other instructions are specified by the customers, prepared with a heat-resistant anti-rust primer (dry coat thickness min. 60 μm). 6 7

Materials for pressure vessels, pipes and fittings Pressure Equipment Directives (PED) in accordance with PED 97/23/EG Description Material codename Material No. Standard Regulation Our glass lined products are subject to PED if they are considered as being valves, columns, vessels and pipe parts. Düker products are in accordance with PED 97/23/EC Pipes, fittings Sheet metal P 235 G1TH 1.0305 DIN EN 10 216-2 AD 2000-W4 P 235 TR 2 1.0255 P 235 GH 1.0345 DIN EN 10 216-1 1 DIN EN 10 217-1 2 AD 2000-W4 DIN EN 10 216-2 DIN EN 10 217-2 + 5 AD 2000-W4 S 235 JR+N 1.0038 AD 2000-W1 P 265 GH 1.0425 DIN EN 10 218-2 AD 2000-W1 Stub ends S 235 JR+N 1.0038 Loose flanges S 235 JR+N 1.0038 Flanges S 235 JR+N 1.0038 Dished heads P 265 GH 1.0425 Dished heads P 265 GH 1.0425 Housing (valves) S 235 JR+N 1.0038 DIN EN 10 273 DIN EN 10 216-1 + 2 DIN EN 10 273 DIN EN 10 216-1 + 2 AD 2000-W9 AD 2000-W9 AD 2000-W9 AD 2000-W1, AD 2000-W12 (AD 2000-W13) AD 2000-W1, AD 2000-W12 (AD 2000-W13) AD 2000-A4, AD 2000-W4, AD 2000-W13 GE S8 1.0420 DIN EN 10 213-2 AD 2000-W4, AD 2000-W5 Düker handles the PED as follows: 1. Valves to module A 1, monitored by TÜV with CE-mark (CE 0036). 2. Pipelines, columns and vessels to module G, single inspection by TÜV, with CE-mark (CE 0036). 3. Pipe spools to module A1, monitored by TÜV with CE-marking DN 32-100 (CE), DN 125-350 (CE 0036) Konformitätserklärung Declaration of Conformity gemäß Druckgeräterichtlinie 97/23/EG in accordance with Pressure Equipment Directive 97/23/EC Der Hersteller: The manufacturer TE Technisches - Email 63846 Laufach, Hauptstraße 39-41 Qualitätssicherungssystem Zertifiziert nach DIN EN ISO 9001:2008 Registrier-Nr. 515183 QM08 erklärt, dass die Rohrleitungsteile aus Stahl emailliert nach DIN 2873 / DIN EN ISO 28721-4: declares, that the single pipes made of steel, glass-lined acc. DIN 2873 / DIN EN ISO 28721-4: Herstelljahr: 2015 Year when built: AB-Nr. 0000000 Rohrleitungsteile, ohne Kategorie DN 15-25 Single pipe parts, without Category Rohrleitungsteile, Kategorie I, Modul A DN 32-100 Single pipe parts, Category I, module A Rohrleitungsteile, Kategorie II, Modul A1 DN 125-350 Single pipe parts, Category II, module A1 Max. zulässiger Druck PS (bar) -1/10 max. allowable pressure PS Zulässige max./min. Temperatur TS ( C) allowable max./min. temperature TS -10/200 Fluidgruppe Fluid group Kennzeichnung Marking 1 DN 15-25 - Düker-Serien-Nr. DN 32-100 - Düker-Serien-Nr. + CE DN 125-350 - Düker-Serien-Nr. + CE0036 1 seamless pipes 2 welded pipes Careful quality conformance inspection guarantees that only the correct materials are used. We check our pre-defined analysis by examining random samples with a spectrometer in our own laboratory. mit der Druckgeräterichtlinie 97/23/EG übereinstimmt. complies with the requirements of the Pressure Equipment Directive 97/23/EC. Angewandtes Regelwerk: AD 2000-Merkblätter / AD 2000-Code Applied code: Konformitätsbewertung nach: Conformity Assessment Procedure: Überwachende benannte Stelle: Monitoring notified body: Nummer der Konformitätsbescheinigung: Certificate of conformity number: Ort, Datum City, date Laufach, 19.03.2015 Modul A1 (Interne Fertigungskontrolle mit Überwachung der Abnahme) Module A1 (Internal manufacturing checks with monitoring of the final assessment) TÜV SÜD Industrie Service GmbH 97080 Würzburg, Petrinistr. 33a 0036 Z-IS-DD1-WZB-15-02-2394514-A1-002 Abteilung Unterschrift department signature TE Technisches - Email Gerd-Peter Imhof Glass Lining Technology FB GCH-GP-030-00.10 / 19.03.2015 8 9

Installation Instructions for glass lined pipes and fittings (part of our installation instructions) Transport and Storage Do not remove the protective caps from the pipeline parts Avoid external loads, vibration and impact Installation Use soft gaskets (PTFE or PTFE-envelope) Connection bolts are to be fastened with the recommended thightening torques Support system DN 25 bis 100: max. distances 3 000 mm DN 125 bis 400: max. distances 4 000 mm Select kind of support (fixed, guiding or loose support) Working conditions Pressure testing of the installed pipeline is to be carried out at 1,1 times of the admissible working pressure to AD 2000 - HP 30 Consider working pressure conditions (pressure, temperature) and admissible bending of the glass lined pipes General Do not weld on glass lined pipe parts Earthing studs are to be used in case where electrostatical charges are likely to occur (contact Düker) Please ask for our detailed installation manual or download from www.dueker.de 10 11

GLASS LINING TECHNOLOGIES JOBBING FOUNDRY FITTINGS AND VALVES DRAINAGE TECHNOLOGY 08.15 Specifications subject to change without notice. Hauptstraße 39-41 D-63846 Laufach Tel +49 6093 87-244 Fax +49 6093 87-303 Internet: www.dueker.de E-Mail: verkauf.tech-email@dueker.de