Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

Similar documents
TP Series OWNER S MANUAL. Price Computing Scale (VER.2)

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Crane Scale. NC Series OWNER S MANUAL

CASTON OWNER S MANUAL

Model 8000XL OPERATOR MANUAL

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS

GRAVITY MEASUREMENT, INC.

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

OVERVIEW OF CONTROLS

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User Guide. Digital Shipping Scale S150

Price Computing Scale DS Series Operation Manual

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

CITIZEN. series. Precision Balances

Model 7400 OPERATOR MANUAL

Peninsula Folding Lift Table Manual

Compact Scales. Software Revision V1.25 & above

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Price Computing Scale D Series Operation Manual

SPC Series. Digital Scale. Operation Manual

Midmark Electric Lift Table Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Model Insulation Tester / Megohmmeter. User Manual

Operating and Service Manual

SSP-Series Portable Balances Operation Manual

Quick Guide. brite Advanced Retail scale

LE.3k Operation Manual

PORT-A-WEIGH CRANE SCALES

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Weighing Scale IDS-802. User Manual

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

TABLE OF CONTENTS 10.0 WARRANTY

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

PolyStat Immersion Circulators

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Axle Load Scale XTR686

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

IAQ-CALC TM Indoor Air Quality Meter

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

PEANUT ROASTER Instruction Manual Model #5081

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

Premier Mobile Electric Lift Table Setup Manual

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Fairbanks Scales OPERATING MANUAL. HAZARDOUS ENVIRONMENT INDICATOR Model H D. BULLETIN SJ4572 / Issue #2

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

BroadBand PowerShield. 20 AHr Battery. User Manual

STAINLESS STEEL LCD DIGITAL SCALE

MODEL PS-4 DIGITAL PORTION SCALE

Breath Alcohol Tester

Digital Body Weight Scale

Breath Alcohol Tester

Adam Equipment CPW COMPACT SCALE

Model 594KL Digital Chair Scale

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

OPERATION AND MAINTENANCE

uline.com

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

OCS-T High Resolution Digital Crane Scale

IAQ-CALC TM Indoor Air Quality Meter

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

Model DS7060 Handrail Scale. User Manual

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

3000 SERIES DRY-BLOCK HEAT SOURCE

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free


Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Indoor Air Quality Meter

This document is hosted by Old Will Knott Scales GBK and GFK Series

Model Battery Powered Milliohm Meter

User s Manual. quattro. Version 1.0

Valor 2000 Series Instruction Manual

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH DOCU-M

Kompensator External Low Voltage Heating Cable System

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Type Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 BARNSTEAD THERMOLYNE

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

Adam Equipment AE 401 INDICATORS. (P.N. 9520, Revision B3, September 2008)

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS. Model No LT1186X4 5/1/00

Transcription:

Easy Weigh OWNER S MANUAL MODEL: AC-100 ADVANCED COUNTING SCALE VER 1.00

TABLE OF CONTENTS SPECIFICATIONS... 1 NOMENCLATURE... 1 FUNCTION KEYS... 2 DISPLAY... 3 ACCURACY SPECIFICATIONS... 4 UNPACKING & ASSEMBLY... 5 SAFETY PRECAUTIONS... 6 OPERATING THE SCALE... 6 PROGRAM MODE... 9 OPTIONS & ACCESSORIES... 12 TROUBLESHOOTING & ERROR MESSAGES... 12 PREFACE Easy Weigh would like to thank you for purchasing our model AC-100 Advanced Counting scale. We are committed to creating high quality low maintenance products and supplying our customers with diligent customer service. This manual contains information on the proper assembly and use of the scale. Disclaimer: This company makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties of merchantability or fitness for any particular purpose. Any software described in this manual is sold or licensed as is. Should the programs prove defective following their purchase, the buyer (and not this company, its distributors, or its dealers) assumes the entire cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. Further, this company reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes. Brand and product names are trademarks and/or registered trademarks of their respective companies.

Specifications Model: AC-100 Maximum Capacity: 10 lb ( 5 kg) 20 lb (10 kg) 50 lb (20 kg) 100 lb (50 kg) Minimum Graduation: 0.001 lb (0.5g) 0.002 lb (1 g) 0.005 lb (2 g) 0.01 lb (5 g) Maximum Tare: Full Capacity Internal Resolution: 200,000 Counts (1/100,000 minimum) A/D Conversion Rate: 6 Updates / second Indirect PLUs: 200 Vacuum Weight: 5 Digits, 999.99 (60 lb max) Fluorescent Unit Price: 6 Digits, 9999.99 max Displays: Total Price: 6 Digits, 9999.99 max Platter Size: Width: 350 mm / 13.8 Length: 270 mm / 10.6 Width: 365 mm / 14.4 Product Size: Length: 365 mm / 14.4 Height: 160 mm / 4.0 Power Requirements: 120 Volts AC @ 60 Hz Operating Temp: 10 C ~ 40 C Humidity RH 35% ~ 85%(no condensation) Power consumption Approx. 6 Watt Fuse rating 250V / 0.2A Nomenclature 1

Function Keys 0 ~ 9 C ZERO Numeric keys, used to enter piece weight, tare, programming, etc. Clear key, used to release error conditions and to clear erroneous entries. Zero key, used to manually set the zero point. TARE Tare key, used to enter tares and clear tares.. UNIT WEIGHT SAMPLE ADD SUM Decimal Point key, used to enter a decimal point. Unit Weight key, used to enter the piece weight. The piece weight is also called the unit weight. Sample key, used to take samples from a known count and determine the piece weight. Add key, used to add the current count to a running total. Sum key, used to totalize the running total generated by the Add key. 2

WEIT CONV MODE M Weight Conversion key, used to change from pound mode and gram mode. Mode key, used to switch between Limit Counting mode and Weight Counting mode. Memory Write key, used to store PLUs. M SET Memory Recall key, used to recall PLUs. key, reserved for future use. Used to display percent accuracy. Set key, used as enter key in Limit Counting mode. Display Zero lamp indicates that the scale is a gross zero. Stable lamp indicates that the weight on the scale is stable. Net lamp indicates that there is a tare set. lb / g lamps indicate whether scale is displaying pounds or grams. Accumulator lamp indicates that there is a running count total. Ls lamp indicates a lack of sample condition. 3

Lu lamp indicates a lack unit weight condition. % lamp indicates the percent of accuracy in counting. 1000 pcs / lb lamp indicates the weight in pounds per 1000 pieces. 1 pcs g lamp indicates the weight of one (1) piece in grams. Limit mode lamp indicates that the scale is in Limit mode. Accuracy Specifications The Ls Lamp will flash when a sample s Total Weight is < 0.5% of capacity. Maximum Capacity: 10 lb ( 5 kg) 20 lb (10 kg) 50 lb (20 kg) 100 lb (50 Minimum Graduation: 0.001 lb (0.5g) 0.002 lb (1 g) 0.005 lb (2 g) 0.01 lb (5 g) 0.5% of capacity: 0.050 lb (25 g) 0.100 lb (50 g) 0.250 lb (100 g) 0.50 lb (250 g) 1/100,000 0.0001 lb (0.05 g) 0.0002 lb (0.1 g) 0.0005 lb (0.2 g) 0.001 lb (0.5 g) The Ls Lamp will turn off once the Weight on the platter surpasses 0.5% of the scale s capacity. When the Ls Lamp is flashing, it means that you need to use more parts in your sample in order to get improved accuracy. As you place more parts on to the platter, the scale will automatically re-sample. You will notice that re-sampling has taken place when the Weight display flickers after you add more parts to the platter. The Lu Lamp will flash when a sample s Piece Weight is < 0.005% of capacity. Maximum Capacity: 10 lb ( 5 kg) 20 lb (10 kg) 50 lb (20 kg) 100 lb (50 Minimum Graduation: 0.001 lb (0.5g) 0.002 lb (1 g) 0.005 lb (2 g) 0.01 lb (5 g) 0.005% of capacity: 0.0005 lb (0.25 g) 0.0001 lb (0.5 g) 0.0025 lb (1 g) 0.005 lb (2.5g) 1/100,000 0.0001 lb (0.05 g) 0.0002 lb (0.1 g) 0.0005 lb (0.2 g) 0.001 lb (0.5 g) The Lu Lamp will turn off once the Unit Weight surpasses 0.005% of the scale s capacity. When the Lu Lamp is on, it means that the part you are trying to count is very close to the scale s minimum detectable weight of 1/100,000. This can affect the scale s accuracy. You can use the key in order to get a better picture of how accurate your tally will be. The key will display the percent accuracy value only after the scale automatically re-samples. 4

Unpacking & Assembly Your AC-100 scale should come with the following: NO Parts Name Units QTY 4-1 IN CARTON BOX EA 1 4-2 STYROFOAM EA 2 4-3 BODY POLY BAG EA 1 4-4 MANUAL POLY BAG EA 1 4-5 AC CORD EA 1 4-6 MANUAL EA 1 4-7 CAL SEALING BOLTS EA 2 4-9 FUSE EA 1 4-10 CAL PLATE AND SEAL EA 1 4-12 FUSE POLY BAG EA 1 4-13 STYROFOAM PAD EA 2 4-14 BOX PAD EA 1 4-15 SILICA DESICANT EA 2 5

Safety Precautions Place the scale on a flat and rigid surface Place the scale far from strong RF interference Level the scale using its adjustable feet Do not subject the platter to sudden impacts Do not spill the water or any other liquid on the scale Do not use any solvents to clean the scale Do not remove the safety ground on the power cord Operating the Scale Make sure the platter is sitting properly on top of the platform and that there is nothing on top of the platter. Also, make sure that the scale is plugged into the proper outlet. Place the power switch into the ON position. The scale displays will run through a self test, count down to zero, and then beep. All of your displays should look as follows: 0.00 0 0 The number of significant digits on the weight display may vary depending on the scale s capacity and the current weighing unit being displayed. Manual Tare Entry 1. Make sure the Zero and Stable Lamps are on. 2. Select the weighing unit you wish to use by pressing the WEIGHT CONV. Key. 3. Type the tare weight of the item that you wish to tare. Do not use the decimal point key as the scale will always automatically insert the decimal point. 4. Press the TARE key. 6

Platter Tare Entry 1. Make sure the Zero and Stable Lamps are on. 2. Select the weighing unit you wish to use by pressing the WEIGHT CONV. Key. 3. Place the item you wish to tare onto the platter. 4. Make sure that the Stable Lamp is on. 5. Press the TARE key. Counting by Unit Weight Entry 1. Make sure the Zero and Stable Lamps are on. 2. Follow the platter or manual tare entry procedures if necessary. 3. Place the parts that you wish to count on the platter. 4. Type the unit weight. You may use the decimal key if necessary. Remember that when you are in pound mode you are entering the Unit Weight for 1000 pieces not for 1 piece. 5. Make sure that the Stable Lamp is on. 6. Press the UNIT WEIGHT key. Steps 3 & 4 can be interchanged. The scale will now display a unit weight and a count. The scale may also flash the Ls or Lu Lamps depending on certain criteria specified on page 4. You can begin counting. Counting by Sample Entry 1. Make sure the Zero and Stable Lamps are on. 2. Follow the platter or manual tare entry procedures if necessary. 3. Place the parts that you wish to count on the platter. 4. Enter the number of parts that you placed on the platter by using the numeric keys. You cannot use the decimal key. 5. Make sure that the Stable Lamp is on. 6. Press the SAMPLE key. Steps 3 & 4 can be interchanged. The scale will now display a unit weight and a count. The scale may also flash the Ls or Lu Lamps depending on certain criteria specified on page 4. You can begin counting. 7

Counting by Using PLUs 1. Make sure the Zero and Stable Lamps are on. 2. Place the parts that you wish to count on the platter. 3. Enter the PLU number of the part that you wish to count. PLU numbers range from 0 to 199. 4. Make sure that the Stable Lamp is on. 5. Press the M key. Steps 2 & 3 can be interchanged. The scale will now display a unit weight and a count. The scale may also flash the Ls or Lu Lamps depending on certain criteria specified on page 4. You can begin counting. Using the ADD Function 1. Get into counting mode by using any of the 3 ways of counting (counting by unit weight, sample, or PLU.) 2. Place the batch of parts that you wish to add onto the platter. 3. Make sure that the Stable Lamp is on. 4. Press the ADD key. The displays will show: Add 1 500 5. The Count display above shows 500 as an example. The number in the Count Display represents the Running Total Count. The Number in the Unit Weight display shows the number of times batches have been added to the Running Total Count. 6. Remove the batch of parts that have just been added. 7. If there is another batch of parts you wish to add go to step 2 otherwise continue on to step 8. 8. Press the SUM key. The displays will show: total 10 5000 8

9. The Count display above shows 5000 as an example. The number in the Count Display represents the Running Total Count. The Number in the Unit Weight display shows the number of batches that have been added to the Running Total Count. 10. If you wish to add more batches then press the SUM and return to step 2; otherwise, you can press the C key to clear the current Running Total and start a new one. When the Acc Lamp is on, it means that there is an active Running Total. Program Mode Programming PLUs by Sample: 1. Make sure the Zero and Stable Lamps are on. 2. Select the weighing unit you wish to use by pressing the WEIGHT CONV. Key. 3. Place the parts that you wish to count on the platter. 4. Enter the number of parts that you placed on the platter by using the numeric keys. You cannot use the decimal key. 5. Make sure that the Stable Lamp is on. 6. Press the SAMPLE key. 7. Press the M key. The displays will show: tare 0 8. Enter the tare weight for this PLU using the numeric keys. You may use the decimal key if necessary. Keep in mind the weighing unit (pounds or grams) for this PLU when you enter the tare. 9. Press the M key. The displays will show: Unit 0 9

The Number in the Unit Weight display represents the Weighing Unit for the PLU: 0 = grams and 1 = pounds. 10. Press 1 for pounds or 0 for grams. 11. Press the M key. The displays will show: Addr 0 The Number in the Unit Weight display represents the PLU number. It can range from 0 to 199 for a total of 200 PLUs. 12. Enter the PLU number using the numeric keys. Keep in mind that if you use an existing PLU number it will be overridden by the new data that you have just entered. 13. Press the M key. The PLU is stored. Programming PLUs by Unit Weight Entry: 1. Make sure the Zero and Stable Lamps are on. 2. Type the unit weight of the part. You may use the decimal key if necessary. Remember that when you are in pound mode you are entering the Unit Weight for 1000 pieces not for 1 piece. 3. Press the M key. The displays will show: tare 0 4. Enter the tare weight for this PLU using the numeric keys. You may use the decimal key if necessary. Keep in mind the weighing unit (pounds or grams) for this PLU when you enter the tare. 5. Press the M key. The displays will show: Unit 0 10

The Number in the Unit Weight display represents the Weighing Unit for the PLU: 0 = grams and 1 = pounds. 6. Press 1 for pounds or 0 for grams. 7. Press the M key. The displays will show: Addr 0 The Number in the Unit Weight display represents the PLU number. It can range from 0 to 199 for a total of 200 PLUs. 8. Enter the PLU number using the numeric keys. Keep in mind that if you use an existing PLU number it will be overridden by the new data that you have just entered. 9. Press the M key. The PLU is stored. Programming & Using Hi and Lo Limits: 1. Make sure the Zero and Stable Lamps are on. Press the MODE key. The displays will show: L im i t Lo 0 The Number in the Count display represents the low limit for Limit Counting. When you are counting: if the Current Count > 0 and Current Count < Low then the Limit Lamp will flash and the scale will continuously beep. 2. Enter the low limit using the numeric keys. If you do not want a low limit press the C key. 3. Press the SET key. The displays will show: L im i t H igh 0 11

The Number in the Count display represents the high limit for Limit Counting. When you are counting: if the Current Count > High then the Limit Lamp will flash and the scale will continuously beep. 4. Enter the high limit using the numeric keys. If you do not want a high limit press the C key. 5. Press the SET key. To disable the use of Limit Mode simply enter 0 as the low limit and 0 as the high limit. Options & Accessories The following options are available through your Easy Weigh Authorized dealer: Description Part Number Spill-Proof Overlay (Wet cover) 101-00001-020000 AC Power cord 690-00001-02002M Adjusting feet (set of 4) 4B0-00001-020000 For any type of service or troubleshooting, please contact your nearest Easy Weigh Authorized dealer. DO NOT attempt to service, repair, or disassemble this or any scale as this is legally permissible to only licensed professionals. Troubleshooting & Error Messages Error Description Solution Zero Initial zero range error Empty the platter, turn OFF and ON. If this occurs again then call service AdC Analog circuit failure Call service EEP Memory failure Call service PArA Parameter failure Call service For more information go to: http://www.atronsystems.com 12

13

Easy Weigh www.atronsystems.com Copyright 2005, All rights reserved. 800-10002-020000