Technical specification

Similar documents
1 / Genset general description

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

1 / Genset general description

28 KW / 28 KVA POWERED by

55 KW / 70 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

45 KW / 55 KVA POWERED by

95 kw. kva. 85 kw. kva. MECC ALTE ECP34-1S Control card

18 KW / 18 KVA POWERED by

1800 KW / 2250 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

2000 KW / 2500 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

600 KW / 750 KVA POWERED by

APD-ULJ250. Standby Power

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

70 KW / 90 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1000 KW / 1250 KVA POWERED by

16 KW / 20 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

80 KW / 100 KVA POWERED by

Standby Amper VOLTAGE

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

130 KW / 165 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

30 KW / 40 KVA POWERED by

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

TPD2250H6.3 TECHNICAL DATA

Standby Amper VOLTAGE

204 KW / 254 KVA POWERED by

640 KW / 800 KVA POWERED by

64 KW / 80 KVA POWERED by

Diesel generator set 6BT5.9 series engine

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

APD-NG400. NG Standby Power

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Rental Power QSB7 series engine

700 KVA / 550 KW POWERED by

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

23 KW / 29 KVA POWERED by

Better Soundproof, Better Life!

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

500 KW / 625 KVA POWERED by

Diesel generator set QSK60 series engine

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

300 KW / 375 KVA POWERED by

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Diesel generator set QSK23 series engine

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Diesel generator set QSK23 series engine

Diesel generator set QSL9 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

60 KW / 75 KVA POWERED by

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set QSX15 series engine

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSX15 series engine

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

57 KW / 71 KVA POWERED by

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS1100

Rental Power QSL9 series engine

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Transcription:

Technical specification Stand-by Generator Sets TECHNICAL INFORMATION Standby Power KVA 2500 (ESP) KW 2180 Prime Power KVA 2281 (PRP) KW 1975 Mechanical structure Open skid on base frame Engine CUMMINS QSK60-G6 Alternator STAMFORD PI734F Control card DEEP SEA 7310 Measures (L x W x H) mm 6000 x 2180 x 2850 Empty weight kg 18350 Fuel tank capacity (L) 1000 (External Fuel Tank) Voltage 230/400 254/440 266/460 Prime power(prp) (KVA) (KW) Standby Power(ESP) (KVA) (KW) 277/480 2281 1975 2500 2180 Notes: PRIME POWER: Electrical power data available at a variable load without limits of hours per year. An overload of 10% is allowed for 1 hour of every. In accordance with ISO 8528/1 (2005)-PRP. STANDBY POWER: Electrical power data at variable load in an emergency in accordance with standard ISO 8528/1(2005)-ESP. Overloads of emergency power are not allowed. The standard reference conditions are: 25 ºC, 100 kpa and 30% relative humidity. Gasoil density: 0.85 g/cm 3. Gasoline density: 0.68 g/cm. Page 1 of 8

INDEX General description Engine Alternator Bedplate Electric Panel ATS Regulation YB generators are available with CE certification along with the Installation Quality Assurance (IQA) from Cummins and designed in facilities certified to ISO 9001. Our Genset s accept load as per NFPA 110 We reserve the right to modify any characteristic of their equipment without prior warning. Photographs representing the product range, while able to include options. Weight and dimensions of a standard generator set. GENERAL DESCRIPTION Generator set for automatic operation due to a grid failure, including the electrical operations panel, installed on a bedplate. Start-up of the generator set will be carried out when a failure in the grid power supply is detected. Once the generator set has stabilized, a signal is sent to the switching panel to switch the grid position to generator set. When the grid power supply return is detected, a command is sent to the switching to switch to the generator set position of the grid. The generator set shuts-down after the applicable cooling period has elapsed. Page 2 of 8

ENGINE Cummins Diesel 4 stroke engine, rear cooling, with direct injection and engine regulation via ECM type electronic management and BELDEN connector wire for exporting data to the digital control panel. Engine brand CUMMINS Bore (mm) 159 Model QSK60-G6 Stroke (mm) 190 R.P.M 1800 Compression ratio 14.5:1 Net power (KWm) 1740 Type of regulation ECM GCS Fuel Diesel Europe exhaust emission EUO No. of cylinders 16 EPA exhaust emission EPA2 Engine Capacity (c.c.) 60200 TA Luft exhaust emission TA Luft 0 Cooling System Cooling of the sleeves using cooling fluid comprised of water and glycol at 50% in a closed circuit driven by the engine pump. Engine driven exhaust fan, radiator and expansion tank; original from the engine manufacturer. The circuit is completed with the cooling purge system towards the outside of the bedplate and protections of all running surfaces Cooling type Water Coolant capacity (L) 300 Design temperature radiator 50 C Generator Set Point Engine : Water jacket heater 277V Power Panel: 4 Poles Main Circuit Breaker Enclosure : Sound Attenuated Canopy Warranty: 5 years for standby application 2 years for prime application Alternator : Lubrication System Alternator Heater PMG kit Silencer : 9 db attenuation industrial silencer 25 db residential-delivered loose Gear pumps lubrication system driven by the engine and with original engine manufacturer lubricant filtering system. It is completed by an outward purge circuit by means of a manual purge pump. Oil capacity (L) 231 Air Intake System Air intake system for combustion with filtering device and filter change indicator; originals from the engine manufacturer. Intake air cooling after the turbo by means of an air/air exchanger. Intake air flow (litre/s) 2900 Page 3 of 8

Exhaust System Optional exhaust silencers with -13 db(a),-26 db(a) or -35 db(a) of attenuation, made in painted steel inside and out, highly resistant to corrosion and with a water drainage system Ya gas emission ( C) 475 Maximum exhaust back pressure (In Hg): 2 Gas flow (m 3 /min) 438.91 Start System Start system that uses an electrical motor, battery, battery dis-connector and battery charge alternator that is driven by the engine itself. The start motor and the battery charge alternator are originals from the engine manufacturer. Lead acid battery with Spiral cell recombining technology, sealed structure to prevent leaks, maintenance free, large start-up capacity maintaining the voltage due to its low internal resistance and small volume thanks to its rolled plate s design that guarantees it will withstand many discharges with large temperature changes. Starter voltage system (V) 24 Battery type 2*12V 200Ah Fuel supply system The fuel intake system has a high performance decanter filter that prevents particles greater than 30 microns from passing through them. Includes level sensor with low fuel alarm signal that indicates the amount of fuel available in the tank to the electrical panel. Fuel tank capacity (L) 1000 (External Fuel Tank) Fuel consumption panel (range according to the standard configuration) OUTPUT POWER FUEL CONSUMPTION % KWm hp kg/ lb/ litre/ US gal/ KWm h hp h hour hour STANDBY POWER 100 2180 2922 0.203 0.334 521 137.5 PRIME POWER 100 1975 2647 0.201 0.330 446 123.1 75 1481 1986 0.204 0.336 356 94.0 50 988 1324 0.213 0.350 247 65.3 25 494 662 0.249 0.409 144 38.1 CONTINUOUS POWER 100 1740 2332 0.201 0.331 412 108.7 Page 4 of 8

ALTERNATOR STAMFORD alternator with 4 poles, with a life time lasting greased bearing, H class insulation, without brushes, 2/3 coil pitch, IP23 and AVR (Automatic Voltage Regulator). Protection of the windings in environments with up to 95% relative humidity and in indoor marine use. Separately excited by PMG with overload capacity 3 times the nominal current for 10 s. Joining of engine and alternator is through a flexible disc coupling. Regulations: IEC 60034 NEMA MG 1.22 ISO 8528:3 CSA UL 1446 Low wave distortion: THC < 4% THD < 4% THF (IEC) < 2% TIF (NEMA)<50 Behavior during transients: Voltage drop below 18% for acceptance of the nominal load with a power factor of 0.8 Recovery time lower than 0.5 s for 20% voltage drops. Incorporates electromagnetic emissions suppressor in accordance with EN 55011, group 1, class B. Brand: STAMFORD IP Alternator: IP 23 Model: PI734F Excitation system: Separately excited by PMG Alternator power: 2345-2435 AVR model: MX321-MX341 Number of reconnectable wires: 12 Voltage stability: ±1% Winding: 311 BEDPLATE The engine-alternator set is coupled to the bedplate by means of anti-vibration shock mounts that absorb almost all the vibrations. The bedplate is made of a phosphate, passivity steel profile with polyester dust paint that guarantees a resistance of at least 500 hours in a saline fog chamber in accordance with standard ASM B-117-09. The fuel tank is integrated and welded into the base frame, includes level sensor with low fuel alarm signal that indicates the amount of fuel available in the tank. Page 5 of 8

ELECTRIC PANEL Electrical panel integrated in the generator set with DEEP SEA digital control plate, quick switching of the grounding system (TT, TN or IT) and emergency shutdown pushbutton. As an option, it may include a single-pole circuit breaker, manually actuated, with thermal-magnetic protection against overloads and short-circuits. In addition, it has a Mitsubishi brand circuit breaker, manually actuated, with thermal-magnetic protection against overloads and Short-circuits. Circuit Breaker rated current (A) 3P 3200A Battery charger DSE 9470-24V SA Has a DEEP SEA battery charge maintainer, designed to be permanently connected to the battery and maintains it charged to its maximum capacity. Has no moving part. The charger switches to floating mode when the charge is complete. Dimensions And Weight Length (mm) 6000 Height (mm) 2850 Width (mm) 2180 Weight (Kg) 18350 Page 6 of 8

Electric Panel DEEP SEA control plate, DSE 7310 with grid monitor that starts-up the generator set when it detects a failure in the electrical power supply from the grid and sends a signal to the switching panel to switch from the grid position to the group position. Once the power supply has been re-established, it sends an order to the switching panel to transfer the generator set power to the grid and shuts-down the generator set once it has cooled down. It also starts-up the generator set using an external signal. Also, control plate DSE 7310 checks a large number of parameters of the generator set which allows it to display information, statuses and alarms. If required, it will shutdown the generator set: due to high coolant fluid temperature, low oil pressure, low coolant fluid level,etc. Includes a 132*64 pixel LCD screen with lighting,5 navigation menu buttons, independent operational mode buttons, and alarms and status indicating LED s. Communications via USB, RS232, RS485, as well as DSE net for system upgrade. Possibility of Ethernet connection (requires a separate module).modbus protocol available for client software. Completely configurable using a PC in Windows environment and free Scada type software in real time. Includes reading and displaying of parameters with RMS values, real time clock, events history log up to 250 events and programming of alarms, events, start-ups and shutdowns. Operating modes: START-UP,SHUTDOWN,AUTO,and MANUAL. Generator Generator voltage (L-N) Generator voltage (L-L) Generator frequency Generator current kw kva kwh kva Power factor Grid Grid voltage (L-N) Grid voltage (L-L) Grid frequency Engine Turn speed Cooling fluid temperature Oil pressure Hour meter Battery voltage No. of start-ups Fuel level Page 7 of 8

ATS Protections Start-up fault (generator set shutdown) High coolant temperature(alarm and generator set shutdown) Low oil pressure (alarm and generator set shutdown) Low fuel level (alarm) Low cooling fluid level (generator set shutdown) Overload (alarm and generator set shutdown) Battery voltage high (alarm) Battery voltage low (alarm) Battery charge alternator failure (alarm) Generator low frequency (alarm and shutdown) Generator high frequency (alarm and shutdown) Generator low voltage (alarm and shutdown) Generator high voltage (alarm and shutdown) External emergency shutdown (shutdown) Engine over speed (shutdown) Optional cabinet for switching between the grid and the generator set by means of a Socomec brand motorized switch with an integrated mechanical and electrical interlocking device, allows for the padlock locking function includes Manual /Automatic mode selector and emergency manual control. Safety switching for isolating the loads. High dynamic resistance against short-circuits. Position indicator with fully visualized cut-off. Stable positions not affected by changes in voltage and mechanical vibrations. External electrical control of the positions and test sequences High number of operations. IP54 protection. Connections: Lower/lower ATS 3P 3200A 277/480V Performance Class Execution class in accordance with ISO 8528/5(2005) taking into account the behavior of the behavior of the generator set in a permanent mode of operation with different load levels, as well as in a temporary mode of operation due to shocks in the load. Performance class G3 REGULATION The generator set has a CE Marking that includes the following directives: Machinery Directive / Directive 98/37/EC Low Voltage Directive / Directive 2006/95/EC EMC Directive / Directive 2004/108/EC Applicable international regulations: ISO 8528 IEC 529 BS 60034 Page 8 of 8