NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs

Similar documents
NPA-CP Pendant Control Station

NPA-CP. Pendant control station OPTIONS FEATURES CERTIFICATIONS

Charlie Pendant Control Station

BASE Rotary Limit Switch

PF2C Rotary Limit Switch. PF2C Rotary Limit Switch

50A. Slip ring collector OPTIONS FEATURES CERTIFICATIONS

10A/30A. Slip ring collector OPTIONS FEATURES CERTIFICATIONS

50A Slip Ring Collector

Position Limit Switches PLTA

FOX. Rotary limit switch. OptiOns. FeatuRes. CeRtiFiCatiOns

OSCAR. Rotary limit switch. OptiOnS. FeAtuReS. CeRtiFiCAtiOnS

7551 Position Limit Switch

GF4C. Rotary limit switch. business partner. Product description. General technical specifications. Technical specifications of the microswitches

Pendant control stations 6

Rotary Limit Switches Driver FRM Series

Rotary Limit Switches Driver FRS Series

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

XACA871 pendant control station XAC-A - 8 pushbuttons

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

TAE pole Contactors

Pendant control stations

Microswitches M series

Industrial Contactors CTX 3 3P 185A - 800A

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Operating instructions Solenoid interlock EX-AZM About this document. Content

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

XACA871 pendant control station XAC-A - 8 pushbuttons

LK Position Switches TECHNICAL DATASHEET.

SWITCHGEAR. 4G cam switches

ype UP T Busplugs Low Voltage Switchboard Equipment

XACA871 pendant control station XAC-A - 8 pushbuttons

FL series position switches

Safety rope switches with reset for emergency stop

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control Buttons / Switches for Panel Mounting Series 8003

ASL09..S 3-pole Contactors - Spring Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Safety switches for hinged doors

Safety switches with separate actuator

MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5

Switches with manual reset

Switch Disconnectors

For many applications

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

Safety switches for hinges

Single foot switches - PX and PA series

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

AE 9... AE 40 Contactors NE... Contactor Relays

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Installation Contactors RIC, RAC

Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls.

Single foot switches PX and PA series

General_technical_data Series

Safety switches with separate actuator

Safety rope switch without reset for simple stop

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

CAUTION CM-SE CM-S21 CM-S41

Safety switches for hinged doors

FOOT SWITCHES

Safety rope switch with reset for emergency stop

Voltage/ Color Coding. 3ø480. 3ø250. 3ø600. 3øY277/408. 3øY120/208. 3øY347/600

vertical fuse switch disconnectors

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

AF40... AF96 3-pole contactors Technical data

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

K50H004UP cam changeover switch - 4-pole A - screw mounting

Position switches FR series

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

WAYBOX Series. Junction boxes for galleries and tunnels

Safety switches with solenoid and separate actuator

Pilot devices. General construction

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

SENTRON Switching and Protection Devices Switch Disconnectors

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Installation and Operating Instructions

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Position switches FD series

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

For Info: Phone: Fax:

K30H001YP cam star-delta switch - 3-pole A - screw mounting

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Limit Switches FCN Series

Transcription:

Pendant control station NPA-CP Pendant station for direct control of industrial machines. Sturdy and handy, NPA-CP is speciically designed for heavy duty in industrial environments. FeAtures The cable sleeve can be angled up to 0 to give the operator the best view of all the control elements and enable a natural, comfortable working position. Rubber s with symbol disks to ensure protection against dust and prevent jamming when the control station is used in harsh environments. Two-colour moulded disks to guarantee clear reading and wear resistance The emergency stop complies with standard EN 8. Positive opening NC contacts for safety functions. Mechanical life of switches: 1 million operations. IP protection degree: NPA-CP is classiied IP65. Extreme temperature resistance: -5 C to +70 C. All materials and components used are wear resistant and guarantee protection of the unit against water and dust. OPtiONs Available in coniguration from to 8 actuators. 1 or speed switches or three-pole switches, with or without brake contact, for direct control. Mechanical interlock to prevent simultaneous operation of opposite functions. CertiFiCAtiONs CE marking and EAC certiication. The data and the products illustrated in this brochure may be modiied without notice. Under no circumstances can their description have a contractual value. 1

CertiFiCAtiONs Conformity to Community Directives Conformity to CE Standards Markings and homologations 006/95/CE Low Voltage Directive 006/4/CE Machinery Directive EN 6004-1 Safety of machinery - Electrical equipment of machines EN 60947-1 Low-voltage switchgear and controlgear EN 60947-3 Low-voltage switchgear and controlgear - Switches, disconnectors, switch-disconnectors and fuse-combination units EN 6059 Degrees of protection provided by enclosures EN 8 Safety of machinery - Emergency stop equipment, functional C GeNerAl technical specifications Storage -40 C/+70 C Ambient temperature Operational -5 C/+70 C IP protection degree IP 65 Insulation category Class II 6 buttons: rubber cable sleeve (Ø 10 18 mm) Cable entry 8 buttons: rubber cable sleeve (Ø 17 6 mm) Operating positions Any position technical specifications OF the microswitches Code PRSL0458PI PRSL0459PI PRSL0460PI Utilisation category AC 3 - AC 4 AC 3 - AC 4 AC 3 - AC 4 Rated operational current Rated operational voltage Rated operational power Rated thermal current Rated insulation voltage 10 A 400 Vac. kw 0 A 660 Vac Brake operating contact - 100 Vac, 0.7 A, L/R=100 ms - Mechanical life Connections 1x10 6 operations Screw-type terminals with self-lifting pads Wires 1x.5 mm, x1.5 mm Tightening torque Microswitch type One speed, double switch 0.8 Nm One speed, double switch, with brake contact Two speeds, double switch 83 Scheme 84 73 74 4 Markings and homologations C

Code PRSL0461PI PRSL0471PI Utilisation category AC 3 - AC 4 AC 3 - AC 4 Rated operational current Rated operational voltage Rated operational power Rated thermal current Rated insulation voltage 10 A 400 Vac. kw 0 A 660 Vac Brake operating contact 100 Vac, 0.7 A, L/R=100 ms - Mechanical life Connections 1x10 6 operations Screw-type terminals with self-lifting pads Wires 1x.5 mm, x1.5 mm Tightening torque Microswitch type Two speeds, double switch, with brake contact 0.8 Nm One speed, three-pole double switch NPA-CP 83 Scheme 84 73 4 4 74 Markings and homologations C Code PRSL047PI Utilisation category AC 3 - AC 4 AC B Rated operational current Rated operational voltage Rated operational power Rated thermal current Rated insulation voltage 10 A 400 Vac. kw 0 A 660 Vac Brake operating contact 100 Vac, 0.7 A, L/R=100 ms - Mechanical life Connections 1x10 6 operations Screw-type terminals with self-lifting pads Wires 1x.5 mm, x1.5 mm Tightening torque Microswitch type One speed, three-pole double switch, with brake contact 0.8 Nm One speed, three-pole single switch 83 1 Scheme 4 84 73 1 74 Markings and homologations C 3

OverAll dimensions (mm) D B A C 99 70 No. of buttons Overall dimensions (mm) A B C D 9 0 76 87 3 333 181 76 87 4 37 76 87 6 459 307 76 87 8 605 393 83 6 4

exploded drawing NPA-CP 35 38 37 36 39 33 1 30 9 7 6 3 4 7 8 5 6 8 5 9 1 10 0 19 18 17 1 16 15 5

standard CONtrOl stations Standard pendant stations are equipped with cable sleeve, hook and mechanical interlock between opposite functions s. 3 actuators PF30030001 PF30030003 1 1 1 1 4 PRSL0471PI three-pole PRSL0460PI speeds 4 PF30030004 1 1 PRSL0458PI 6 actuators PF3006000 PF30060004 1 1 1 1 - - Blanking plug - - Blanking plug PRSL0460PI speeds 4 PRSL0471PI three-pole 4 PRSL0460PI speeds 4 PRSL0471PI three-pole 4 6

PF30060019 1 1 - - Blanking plug PRSL0458PI PRSL0458PI 8 actuators PF30080001 PF30080010 1 1 1 1 - - Blanking plug - - Blanking plug PRSL0460PI speeds 4 PRSL0471PI three-pole 4 PRSL0460PI speeds 4 PRSL0471PI three-pole 4 PRSL0460PI speeds 4 PRSL0471PI three-pole 4 7

PF300800 1 1 - - Blanking plug PRSL0458PI PRSL0458PI PRSL0458PI 8

AssemBlY drawing NPA-CP A8 A10 A A1 A1 A A7 A3 A4 A5 A6 A9 9

COmPONeNts switches Ref. Drawing Description Scheme Code One speed, double switch PRSL0458PI 83 One speed, double switch, with brake contact 84 73 PRSL0459PI 74 Two speeds, double switch PRSL0460PI 4 A1 83 Two speeds, double switch, with brake contact 84 73 PRSL0461PI 4 74 One speed, three-pole double switch 4 PRSL0471PI 83 One speed, three-pole double switch, with brake contact 4 84 73 PRSL047PI 74 1 A One speed, three-pole single switch, for 1 Actuators Ref. Drawing Description Code A6 Blanking plug PRSL0517PI A5 Disk for dust-tight PRTA See standard disk A4 Dust-tight PRSL0550PI 10

s Ref. Drawing Description Code A1 for emergency stop PRSL0600PI A Key PRSL050PI A3 Impulse PRSL051PI Accessories Ref. Drawing Description Code A7 Mechanical interlock PRSL7817P A8 Cable sleeve for - 6 button units Cable sleeve for 8 button units PRGO0100PE PRGO0105PE A9 Wire ixing PRTO666PE A10 Hook PRGA0001PE standard disks RED PRTA00XPI PRTA005XPI PRTA006XPI PRTA007XPI PRTA008XPI PRTA0XPI PRTA01XPI PRTA015XPI PRTA016XPI PRTA018XPI YELLOW WHITE BLACK PRTA019XPI PRTA0XPI PRTA0XPI PRTA06XPI PRTA07XPI PRTA097XPI PRTA098XPI PRTA099XPI

NPA-CP - request FOrm FOr NON standard PeNdANt station Control elements switches 3 actuators 1 5 6 3 7 4 8 A B PRSL0458PI Two-pole switch PRSL0459PI Two-pole switch with brake contact Hook Cable sleeve Control elements 9 10 WHITE 1 BLACK C PRSL0471PI Three-pole switch 17 YELLOW 18 RED 15 16 D PRSL047PI Three-pole switch with brake contact Switch MI 19 PRSL0517PI Blanking plug speed switches E PRSL0460PI Two-pole switch 0 1 PRSL0600PI Emergency stop PRSL051PI Impulse PRSL050PI Key Mushroom s are itted with switches ( ). F PRSL0461PI Two-pole switch with brake contact Hook Cable sleeve -4-6-8 actuators Hook Cable sleeve Switches Control elements MI instructions - Fill in the pendant station scheme for the number of control elements required (, 3, 4, 6, or 8 actuators). - Write the number corresponding to the blanking plug, or symbol required (broken line box). Mark the direction of the arrow into the corresponding circle. - Into the unbroken box, write the letter corresponding to the switches required for the s. - Tick the rectangular box between the s when the mechanical interlock (MI) is required. - Tick the appropriate box to show where the cable sleeve and the hook must be assembled (top or bottom). MI remarks MI MI Hook Cable sleeve 1

use ANd maintenance instructions The NPA-CP Pendant Control Station is an electromechanical device for low voltage control circuits (EN 60947-3) to be used as electrical equipment on machines (EN 6004-1) in compliance with the fundamental requirements of the Low Voltage Directive 006/95/CE and of the Machine Directive 006/4/CE. The pendant station is designed for industrial use and also for use under particularly severe climatic conditions (operational temperature from 5 C to +70 C, suitable for use in tropical environment). The equipment is not suitable for use in environments with potentially explosive atmosphere, corrosive agents or a high percentage of sodium chloride (saline fog). Oils, acids or solvents may damage the equipment; avoid using them for cleaning. The switches (10) are designed for direct control of contactors or electromagnetic loads. Do not connect more than one phase to each switch (10, 18). Do not oil or grease the control elements (, 35, 37, 39) or the switches 10, 18). The installation of the pendant station shall be carried out by an expert and trained personnel. Wiring shall be properly done according to the current instructions. Prior to the installation and the maintenance of the pendant station, the main power of the machinery shall be turned off. steps for the proper installation of the pendant station - Remove the screws (15) on the lower cover () to open the pendant station. - Cut the variable section rubber cable sleeve () and insert the cable tight enough to guarantee protection against water and/or dust. - Fix the cable to the cable sleeve () using a cable tie (not supplied). - Strip the cable to a length suitable for wiring the switches (0, 8). - Tape the stripped part of the cable. - Fix the cable inside the pendant station using the cable clamp (1). - Connect all the switches (10, 18) according to the contact scheme printed on the switches (tighten the terminal screws with a torque of 0.8 Nm; insertability of wires into the terminals 1x.5 mm - x1.5mm ). - Close the pendant station checking the proper positioning of the rubber (1) in the cover (1) and of the O rings (17). - Put the rubber caps for the screws () into the holes in the lower cover (). Periodic maintenance steps - Check the proper tightening of the screws (15) of the enclosure (1, 8, ). - Check the proper tightening of the switch (10, 18) terminal screws. - Check all wiring (in particular where wires clamp into the switches). - Check the conditions of the rubber (1) it into the lower cover (), of the rubber of the control elements (39) and of the cable sleeve (). - Check that the plastic enclosure (1, 8, ) of the pendant station is not broken. In case any component of the pendant station is modiied, the validity of the markings and the guarantee on the equipment are annulled. Should any component need replacement, use original spare parts only. TER declines all responsibility for damages caused by the improper use or installation of the equipment. * Please refer to the exploded drawing in the catalogue. NPA-CP

direct control circuits for three-phase reversing motors Circuits for motors Circuits for brake wiring Circuits for brake and wiring direct control circuits for speed three-phase reversing motors Circuits for speed motors Circuits for brake wiring Circuits for brake and wiring