technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

Similar documents
technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Fan Coil Units. Technical Data

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

Air Conditioning. Technical Data EEDEN RXZ-N

Outdoor Units R-410A ARX-GV1B

Air Conditioners. Technical Data UATYQ-CY1

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Air Conditioners Technical Data

technical data air conditioning systems MXS-B Multi Application Split Sky Air

Split-Sky Air RMX-JZ Super Multi Plus

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

Air Conditioning. Technical Data EEDEN RXJ-L

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

Technical Data. Air Conditioners

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Air Conditioning Technical Data RZQSG-L3/9V1

EWAD-CZ EWAD-CZ. Inverter driven air-cooled chiller. ESEER up to 5.4. Inverter driven single screw compressor. Multiple efficiency and sound versions

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

High Wall Type ( 2 Series )

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

Technical Service Manual

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Compact Four-way Cassette Type

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Service manual MIV V4+ Indoor units

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Air Conditioning Technical Data RZQG-L(8)Y1

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Digital Inverter 4 series

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Four-way Cassette Type

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Low Static Pressure Duct(V shape evaporator)

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Ventilation. Technical Data. Heat reclaim ventilation, humidification and air processing EEDEN VKM-GBM

Applied Systems. Technical Data. Concealed ceiling unit EEDEN FWP-AT

Product. ortfolio RESIDENTIAL & LIGHT COMMERCIAL

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

SERVICE MANUAL OUTDOOR UNIT. No. OB386

Commercial and Technical Data

Air Conditioning. Technical Data. Round flow cassette EEDEN FXFQ-A

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Vertical Air Handling Unit type

Low Static Pressure Duct (V shape evaporator)

VHIA High-Static Ducted Indoor Units - 60HZ

SERVICE MANUAL OUTDOOR UNIT. No. OB387

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

CENTRIFUGAL FAN COIL UNIT VCE

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

FFQN-C, FCRN-E, FFRN-C

WCA4**4. Product Specifications

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

Transcription:

technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems

technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems

Indoor Units 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B TABLE OF CONTENTS FXZQ-M9V1B 1 Specifications....................................................... 2 Technical Specifications............................................. 2 Electrical Specifications (50Hz)...................................... 3 2 Safety device settings............................................. 4 3 Options.............................................................. 4 4 Capacity tables..................................................... 5 Cooling capacity tables.............................................. 5 Heating capacity tables.............................................. 6 5 Dimensional drawing & centre of gravity........................ 7 Dimensional drawing................................................. 7 Centre of gravity..................................................... 8 6 Piping diagram...................................................... 9 7 Wiring diagram..................................................... 10 Wiring diagram...................................................... 10 8 Sound data......................................................... 11 Sound level data.................................................... 11 Sound pressure spectrum........................................... 12 9 Air flow pattern..................................................... 13 VRV Systems Indoor Units 1

s t - i e 4 n t 1 s 0 y 9 0r 6o - xo 0d Z n0 IF 1 Specifications W m B U V S M Q V RX V6 1-1 TECHNICAL SPECIFICATIONS FXZQ20M9V1B FXZQ25M9V1B FXZQ32M9V1B FXZQ40M9V1B FXZQ50M9V1B Capacity Cooling kw 2.2 2.8 3.6 4.5 5.6 Heating kw 2.5 3.2 4.0 5.0 6.3 Power Input (50Hz) Cooling kw 0.073 0.073 0.076 0.089 0.115 Heating kw 0.064 0.064 0.068 0.080 0.107 Casing Material Galvanised steel Dimensions Unit Height mm 286 Width mm 575 Depth mm 575 Weight Unit kg 18 Heat Exchanger Dimensions Nr of Rows 2 Fin Pitch mm 1.5 Face Area m² 0.269 Nr of Stages 10 Fan Type Turbo fan Quantity 1 Cooling High m³/min 9.0 9.0 9.5 11.0 14.0 Low m³/min 7.0 7.0 7.5 8.0 10.0 Fan Motor Quantity 1 Model QTS32C15M Output (high) W 55 Drive Direct drive Refrigerant Name R-410A Sound level Cooling Sound power dba 47 47 49 53 58 (nominal) Cooling Sound Pressure High dba 30 30 32 36 41 Low dba 25 25 26 28 33 Piping connections Liquid (OD) Type Flare connection Diameter mm 6.35 Gas Type Flare connection Diameter mm 12.7 Drain Diameter mm 26 Heat Insulation Foamed polystyrene/foamed polyethylene Decoration Panel Model BYFQ60B7W1 Colour White (Ral 9010) Dimensions Height mm 55 Width mm 700 Depth mm 700 Weight kg 2.7 Air Filter Resin net with mold resistance Refrigerant control Electronic expansion valve Temperature control Microprocessor thermostat for cooling and heating Safety devices PC board fuse Fan motor thermal protector Standard Accessories Installation and operation manual Paper pattern for installation Drain hose Clamp metal Washer fixing plate Sealing pads Clamps Screws Washer for hanger bracket Insulation for fitting Notes Nominal cooling capacities are based on : indoor temperature : 27 CDB, 19 CWB, outdoor temperature : 35 CDB, equivalent refrigerant piping : 7,5m (horizontal) Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent refrigerant piping : 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 2 VRV Systems Indoor Units

1 Specifications 1-2 ELECTRICAL SPECIFICATIONS (50HZ) FXZQ20M9V1B FXZQ25M9V1B FXZQ32M9V1B FXZQ40M9V1B FXZQ50M9V1B Power Supply Name V1 Phase 1~ Frequency Hz 50 Voltage V 220-240 Current Minimum circuit amps (MCA) A 0.8 0.8 0.8 0.8 0.9 Maximum fuse amps (MFA) A 15 Full load amps (FLA) A 0.6 0.6 0.6 0.6 0.7 Voltage range Minimum V -10% Maximum V +10% Notes Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits. Maximum allowable voltage range variation between phases is 2%. MCA/MFA : MCA = 1.25 x FLA MFA is smaller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse, use a circuit breaker VRV Systems Indoor Units 3

2 Safety device settings FXZQ20M9 FXZQ25M9 FXZQ32M9 FXZQ40M9 FXZQ50M9 PC BOARD FUSE 250V 5A FAN MOTOR THERMAL PROTECTOR C OFF: 130 ±5 / ON: 80 ±20 3D006691K 3 Options FXZQ20-50 Options Item Model FXZQ20M9 FXZQ25M9 FXZQ32M9 FXZQ40M9 FXZQ50M9 1 Decoration panel BYFQ60B 2 Sealing member of air discharge outlet KDBH44BA60 3 Panel spacer KDBQ44B60 4 Long-life filter KAFQ441BA60 5 Fresh air intake kit Direct installation type KDDQ44XA60 Control System Item Model FXZQ20M9 FXZQ25M9 FXZQ32M9 FXZQ40M9 FXZQ50M9 1 Remote control H/P BRC7E530 Wireless C/O BRC7E531 Wired For Europe BRC1D52 2 Central remote control DCS302C51 2.1 Electrical box with earth terminal (3 blocks) KJB311A 3 Unified on/off controller For Europe DCS301B51 3.1 Electrical box with earth terminal (2 blocks) KJB212A 3.2 Noise filter (for electromagnetic interface use only) KEK28-1A 4 Schedule timer DST301B51 5 Adapter for wiring * KRP1B57 6.1 Wiring adapter for electrical appendices (1) (Note 2) For Europe KRP2A52 6.2 Wiring adapter for electrical appendices (2) (Note 2) KRP4A53 7 Installation box for adapter PCB KRP1BA101 8 Remote sensor KRCS01-1 9 External control adapter For Europe DTA104A52 10 Multi tenant (Note 3) EKMTAC NOTES 1 All options are supplied as kit 2 The installation box for adapter PCB is required. 3 This kit contains parts to connect with 1ulti tenant indoor units. 3TW31619-1 4 VRV Systems Indoor Units

4 Capacity tables 4-1 Cooling capacity tables FXZQ-M9 Unit size Nominal Capacity Outdoor CDB Indoor air temp.b 14.0WB 16.0WB 18.0WB 19.0WB 20.0 WB 22.0WB 24.0WB 20.0DB 23.0DB 26.0DB 27.0DB 28.0DB 30.0DB 32.0DB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 20 2.2 10.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.6 2.9 1.7 12.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.6 2.9 1.6 14.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.6 2.8 1.6 16.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.8 2.8 1.7 18.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.8 2.7 1.7 20.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.8 2.7 1.7 21.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.8 2.7 1.6 23.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.7 2.6 1.6 25.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.6 1.7 2.6 1.6 27.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.5 1.7 2.6 1.6 29.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.5 1.7 2.5 1.6 31.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.4 1.7 2.5 1.6 33.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.4 1.6 2.5 1.5 35.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.4 1.6 2.4 1.5 37.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.3 1.6 2.3 1.6 2.4 1.5 39.0 1.5 1.3 1.8 1.5 2.1 1.7 2.2 1.7 2.2 1.6 2.3 1.6 2.3 1.5 25 2.8 10.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1 12.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1 14.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1 16.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0 18.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0 20.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0 21.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0 23.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.4 1.9 25.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.0 3.3 1.9 27.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.3 1.9 29.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9 31.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.9 33.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8 35.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8 37.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8 39.0 1.9 1.5 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8 32 3.6 10.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.7 2.6 12.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.7 2.5 14.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.6 2.5 16.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.6 2.5 18.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.5 2.5 20.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.4 2.4 21.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.3 2.5 4.4 2.4 23.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.2 2.5 4.3 2.4 25.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.2 2.5 4.3 2.4 27.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.1 2.4 4.2 2.3 29.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.1 2.4 4.2 2.3 31.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 4.0 2.4 4.1 2.3 33.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 3.9 2.4 4.0 2.3 35.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.8 2.4 3.9 2.3 4.0 2.2 37.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.7 2.4 3.8 2.3 3.9 2.2 39.0 2.4 1.9 2.9 2.1 3.4 2.4 3.6 2.4 3.7 2.4 3.8 2.3 3.8 2.2 40 4.5 10.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.9 3.5 12.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.8 3.4 14.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.8 3.4 16.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.7 3.4 18.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.6 3.3 20.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.5 3.3 21.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.4 3.4 5.5 3.3 23.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.3 3.3 5.4 3.2 25.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.2 3.3 5.3 3.2 27.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.2 3.3 5.3 3.2 29.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.1 3.2 5.2 3.1 31.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 5.0 3.2.5.1 3.1 33.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.8 3.3 4.9 3.2 5.0 3.1 35.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.3 4.7 3.3 4.9 3.1 5.0 3.0 37.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.2 4.7 3.2 4.8 3.1 4.9 3.0 39.0 3.0 2.5 3.6 2.9 4.2 3.2 4.5 3.2 4.6 3.2 4.7 3.1 4.8 3.0 50 5.6 10.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.4 4.4 12.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.4 14.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.2 4.3 16.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.1 4.3 18.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.0 4.2 20.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.2 21.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.8 4.2 23.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.6 4.3 6.7 4.1 25.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.5 4.3 6.6 4.1 27.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.6 4.0 29.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.3 4.2 6.5 4.0 31.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.2 4.1 6.4 4.0 33.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 6.0 4.2 6.1 4.1 6.3 3.9 35.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 5.9 4.2 6.0 4.0 6.2 3.9 37.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 5.8 4.1 5.9 4.0 6.1 3.8 39.0 3.8 3.1 4.5 3.6 5.2 4.0 5.6 4.1 5.7 4.1 5.8 3.9 6.0 3.8 3TW28662-1 VRV Systems Indoor Units 5

4 Capacity tables 4-2 Heating capacity tables FXZQ-M9 Unit size Nominal Capacity Indoor air temp.: CDB Outdoor air temp 16.0 18.0 20.0 21.0 22.0 24.0 ( CDB) ( CWB) KW KW KW KW KW KW 20 2.5-19.8-20.0 1.5 1.5 1.5 1.5 1.5 1.5-18.8-19.0 1.5 1.5 1.5 1.5 1.5 1.5-16.7-17.0 1.6 1.6 1.6 1.6 1.6 1.6-14.7-15.0 1.7 1.7 1.7 1.7 1.7 1.7-12.6-13.0 1.8 1.8 1.8 1.8 1.8 1.8-10.5-11.0 1.9 1.9 1.9 1.9 1.9 1.9-9.5-10.0 1.9 1.9 1.9 1.9 1.9 1.9-8.5-9.1 2.0 2.0 1.9 1.9 1.9 1.9-7.0-7.6 2.0 2.0 2.0 2.0 2.0 2.0-5.0-5.6 2.1 2.1 2.1 2.1 2.1 2.1-3.0-3.7 2.2 2.2 2.2 2.2 2.2 2.2 0.0-0.7 2.3 2.3 2.3 2.3 2.3 2.2 3.0 2.2 2.5 2.5 2.4 2.4 2.3 2.2 5.0 4.1 2.5 2.5 2.5 2.4 2.3 2.2 7.0 6.0 2.6 2.6 2.5 2.4 2.3 2.2 9.0 7.9 2.7 2.7 2.5 2.4 2.3 2.2 11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2 13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2 15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2 25 3.2-19.8-20.0 1.9 1.9 1.9 1.9 1.9 1.9-18.8-19.0 1.9 1.9 1.9 1.9 1.9 1.9-16.7-17.0 2.1 2.1 2.0 2.0 2.0 2.0-14.7-15.0 2.2 2.2 2.2 2.2 2.2 2.1-12.6-13.0 2.3 2.3 2.3 2.3 2.3 2.3-10.5-11.0 2.4 2.4 2.4 2.4 2.4 2.4-9.5-10.0 2.5 2.4 2.4 2.4 2.4 2.4-8.5-9.1 2.5 2.5 2.5 2.5 2.5 2.5-7.0-7.6 2.6 2.6 2.6 2.6 2.6 2.6-5.0-5.6 2.7 2.7 2.7 2.7 2.7 2.7-3.0-3.7 2.8 2.8 2.8 2.8 2.8 2.8 0.0-0.7 3.0 3.0 3.0 3.0 3.0 2.8 3.0 2.2 3.1 3.1 3.1 3.1 3.0 2.8 5.0 4.1 3.3 3.2 3.2 3.1 3.0 2.8 7.0 6.0 3.4 3.4 3.2 3.1 3.0 2.8 9.0 7.9 3.5 3.4 3.2 3.1 3.0 2.8 11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8 13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8 15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8 32 4.0-19.8-20.0 2.4 2.4 2.3 2.3 2.3 2.3-18.8-19.0 2.4 2.4 2.4 2.4 2.4 2.4-16.7-17.0 2.6 2.6 2.6 2.6 2.6 2.5-14.7-15.0 2.7 2.7 2.7 2.7 2.7 2.7-12.6-13.0 2.9 2.8 2.8 2.8 2.8 2.8-10.5-11.0 3.0 3.0 3.0 3.0 3.0 3.0-9.5-10.0 3.1 3.1 3.1 3.1 3.0 3.0-8.5-9.1 3.1 3.1 3.1 3.1 3.1 3.1-7.0-7.6 3.2 3.2 3.2 3.2 3.2 3.2-5.0-5.6 3.4 3.4 3.4 3.4 3.4 3.4-3.0-3.7 3.5 3.5 3.5 3.5 3.5 3.5 0.0-0.7 3.7 3.7 3.7 3.7 3.7 3.5 3.0 2.2 3.9 3.9 3.9 3.9 3.7 3.5 5.0 4.1 4.1 4.1 4.0 3.9 3.7 3.5 7.0 6.0 4.2 4.2 4.0 3.9 3.7 3.5 9.0 7.9 4.3 4.3 4.0 3.9 3.7 3.5 11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5 13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5 15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5 40 5.0-19.8-20.0 3.0 2.9 2.9 2.9 2.9 2.9-18.8-19.0 3.0 3.0 3.0 3.0 3.0 3.0-16.7-17.0 3.2 3.2 3.2 3.2 3.2 3.2-14.7-15.0 3.4 3.4 3.4 3.4 3.4 3.4-12.6-13.0 3.6 3.6 3.6 3.5 3.5 3.5-10.5-11.0 3.7 3.7 3.7 3.7 3.7 3.7-9.5-10.0 3.8 3.8 3.8 3.8 3.8 3.8-8.5-9.1 3.9 3.9 3.9 3.9 3.9 3.9-7.0-7.6 4.0 4.0 4.0 4.0 4.0 4.0-5.0-5.6 4.2 4.2 4.2 4.2 4.2 4.2-3.0-3.7 4.4 4.4 4.4 4.4 4.4 4.4 0.0-0.7 4.7 4.6 4.6 4.6 4.6 4.4 3.0 2.2 4.9 4.9 4.9 4.8 4.7 4.4 5.0 4.1 5.1 5.1 5.0 4.8 4.7 4.4 7.0 6.0 5.2 5.2 5.0 4.8 4.7 4.4 9.0 7.9 5.4 5.3 5.0 4.8 4.7 4.4 11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4 13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4 15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4 50 6.3-19.8-20.0 3.7 3.7 3.7 3.7 3.7 3.7-18.8-19.0 3.8 3.8 3.8 3.8 3.8 3.8-16.7-17.0 4.1 4.0 4.0 4.0 4.0 4.0-14.7-15.0 4.3 4.3 4.3 4.2 4.2 4.2-12.6-13.0 4.5 4.5 4.5 4.5 4.5 4.5-10.5-11.0 4.7 4.7 4.7 4.7 4.7 4.7-9.5-10.0 4.8 4.8 4.8 4.8 4.8 4.8-8.5-9.1 4.9 4.9 4.9 4.9 4.9 4.9-7.0-7.6 5.1 5.1 5.1 5.1 5.1 5.1-5.0-5.6 5.3 5.3 5.3 5.3 5.3 5.3-3.0-3.7 5.5 5.5 5.5 5.5 5.5 5.5 0.0-0.7 5.9 5.9 5.8 5.8 5.8 5.5 3.0 2.2 6.2 6.2 6.2 6.1 5.9 5.5 5.0 4.1 6.4 6.4 6.3 6.1 5.9 5.5 7.0 6.0 6.6 6.6 6.3 6.1 5.9 5.5 9.0 7.9 6.8 6.7 6.3 6.1 5.9 5.5 11.0 9.8 7.0 6.7 6.3 6.1 5.9 5.5 13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5 15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5 3TW25512-2A 6 VRV Systems Indoor Units

5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing FXZQ-M9 Ceiling Required space 1,500mm or more* 1,500mm or more* 1,500mm or more* Note 2 300 or less 585~660 (Ceiling opening space) 533 (Suspention position) 4-M4 Hole Arrow view Outdoor air intake (Direct connection) 1,500mm or more* * When the discharge grill is closeout the required space is 200mm or more Adjustable (0~545) Arrow view Drain connection side Pipe connection side 533 (Suspention position) 585~660 (Ceiling opening space) Nr Part name Description 1 Liquid pipe connection ø6.4 Flare connection 2 Gas pipe connection ø12.7 Flare connection 3 Drain pipe connection VP25 (O.D. ø32) 4 Wire intake 5 Interunit wiring connection 6 Grounding terminal Inside switch box (M4) 7 Discharge 8 Air suction grille 9 Long life filter 10 Suspension bolt Suspention bolt Decoration panel BYFQ60B7W1 White Ral 9010 45 or less 45 or less Note 4 180 295 or more 1,500 or more (Required space) From the floor side 2,500 or more For height installation NOTES 1 Location of manufacturer s label Indoor unit: on the bell mouth, inside suction panel Decoration panel: on the inner frame, inside suction grille 2 When using an infrared remote control, this position will be a signal receiver. Refer to the drawing of the infrared remote control for more details 3 When the temperature and humidity in the ceiling exceed 30 C and RH is 80 %, or the fresh air is inducted into the ceiling, or the unit continues 24 hour operation, an additional insulation is required (thickness 10mm or more or glass wool or polyethylene foam) 4 Though the installation is acceptable up to maximum 660mm square ceiling opening, keep the clearance of 45mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured. 3D039005B FXZQ-M9 700 1 700 A Arrow view 62.5 575 62.5 62.5 575 62.5 255 or more 105 143 245 (140) 2 Nr Name Description 1 Indoor unit 2 Decoration panel 3 Panel spacer 3 A 15 Dimension between the bottom surface of indoor unit and the surface of ceiling 40 Thickness of panel spacer 3D041038 VRV Systems Indoor Units 7

5 Dimensional drawing & centre of gravity 5-2 Centre of gravity FXZQ-M9 4D040158 8 VRV Systems Indoor Units

6 Piping diagram FXZQ-M9 Heat exchanger Gas pipe connection port Flare connection Th3 Th1 Fan Th2 Liquid pipe connection port Flare connection Filter Filter Electronic expansion valve 4D040157 VRV Systems Indoor Units 9

7 Wiring diagram 7-1 Wiring diagram FXZQ-M9 Power supply 220-240V - 50Hz See note 3 Input from outside (See note 4) Transmission wiring central remote control (See note 2) Wired remote control Switch box (See note 3) A1P Printed circuit board R2T Thermistor (coil-liquid) BS1 Push button (on/off) C1 Capacitor (M1F) R3T Transformer (220-240V/22V) H1P Light emitting diode (on-red) F1U Fuse( B, 5a, 250V) V1TR Triac H2P Light emitting diode (timer-green) F2U Field fuse X1M Terminal strip H2P Light emitting diode (filter sign-red) HAP Light emitting diode (service monitor green) X2M Terminal strip H3P Light emitting diode (defrost-orange) KPR Magnetic relay (M1P) Y3E Electronic expansion valve SS1 Selector switch (main/sub) M1F Motor (indoor fan) Wired remote control SS2 Selecter switch (wireless address set) M1P Motor (drain pump) R1T Thermistor (air) connector for optional parts M1S Motor (swing flap) SS1 Selector switch (main/sub) X16A Connector (adapter for wire) Q1DI Field earth leak dedector (max. 300mA) Infrared remote control (receiver/display unit) X18A Connector (on/off) (wiring adapter for Q1M Therminal protector (M1F embedded) A3P Printed circuit board electrical appendices R1T Thermistor (air) A4P Printed circuit board NOTES : Terminal Colors: RED Red PNK pink : Connector BLK Black ORG Orange : Wire clamp WHT White GRN Green : Field wiring YLW Yellow BLU Blue 1 In case of using a remote control, connect it to unit in accordance to the attached installation manual. 2 X23A is connected when the wireless remote control kit is being used. 3 When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control. In details, refer to the installation manual attached the unit. 4 Remote control model varies according to the combination system. See technical data and catalogs. Etc. before connecting. 3TW26426-1B 10 VRV Systems Indoor Units

8 Sound data 8-1 Sound level data FXZQ-M9 Model Sound pressure level H L Measuring location Sound power level FXZQ20M9 30 25 47 FXZQ25M9 30 25 47 FXZQ32M9 32 26 49 1.5 m FXZQ40M9 36 28 53 FXZQ50M9 41 33 Microphone 58 NOTES 1 Measuring place: anechoic chamber 2 Operation noise differs with operation and ambient conditions 3 Operating conditions: Power source: 230V, 50 Hz Cooling: Indoor air temperature: 27 CDB, 19 CWB Outdoor air temperature: 35 CDB, 24 CWB Heating: Indoor air temperature: 20 CDB, 15 CWB Outdoor air temperature: 7 CDB, 6 CWB VRV Systems Indoor Units 11

8 Sound data 8-2 Sound pressure spectrum FXZQ20,25M9 4D040274A FXZQ32M9 4D040285A Octave band pressure level db (0dB=0.002μbar) Hi Low Octave band pressure level db (0dB=0.002μbar) Hi Low Approximate treshold hearing for continuous noise Octave band center frequency (Hz) Approximate treshold hearing for continuous noise Octave band center frequency (Hz) FXZQ40M9 4D040286A FXZQ50M9 4D040287A Octave band pressure level db (0dB=0.002μbar) Hi Low Octave band pressure level db (0dB=0.002μbar) Hi Low Approximate treshold hearing for continuous noise Octave band center frequency (Hz) Approximate treshold hearing for continuous noise Octave band center frequency (Hz) 12 VRV Systems Indoor Units

9 Air flow pattern FXZQ20,25M9 Cooling air velocity distribution 4-way discharge, air flow direction: horizontal 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Cooling air temperature distribution 4-way discharge, air flow direction: horizontal 20 C 22 C 24 C 26 C 4 m 3 m 3 m 4 m 4D039738A FXZQ32M9 Cooling air velocity distribution 4-way discharge, air flow direction: horizontal 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Cooling air temperature distribution 4-way discharge, air flow direction: horizontal 20 C 22 C 24 C 26 C 4 m 3 m 3 m 4 m 4D040188 VRV Systems Indoor Units 13

9 Air flow pattern FXZQ40M9 Cooling air velocity distribution 4-way discharge, air flow direction: horizontal 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Cooling air temperature distribution 4-way discharge, air flow direction: horizontal 20 C 22 C 24 C 26 C 4 m 3 m 3 m 4 m 4D040189 FXZQ50M9 Cooling air velocity distribution 4-way discharge, air flow direction: horizontal 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Cooling air temperature distribution 4-way discharge, air flow direction: horizontal 20 C 22 C 24 C 26 C 4 m 3 m 3 m 4 m 4D040190 14 VRV Systems Indoor Units

9 Air flow pattern FXZQ20,25M9 Heating air velocity distribution 4-way discharge, air flow direction: down 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Heating air temperature distribution 4-way discharge, air flow direction: down 30 C 28 C 26 C 24 C 22 C 4 m 3 m 3 m 4 m 4D039820A FXZQ32M9 Heating air velocity distribution 4-way discharge, air flow direction: down 2,5 m/s 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Heating air temperature distribution 4-way discharge, air flow direction: down 30 C 28 C 26 C 24 C 22 C 4 m 3 m 3 m 4 m 4D040191 VRV Systems Indoor Units 15

9 Air flow pattern FXZQ40M9 Heating air velocity distribution 4-way discharge, air flow direction: down 2,5 m/s 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Heating air temperature distribution 4-way discharge, air flow direction: down 30 C 28 C 26 C 24 C 22 C 4 m 3 m 3 m 4 m 4D040192 FXZQ50M9 Heating air velocity distribution 4-way discharge, air flow direction: down 2,5 m/s 2,/s 1,5 m/s 1,/s 0,5 m/s 4 m 3 m 3 m 4 m Heating air temperature distribution 4-way discharge, air flow direction: down 30 C 28 C 26 C 24 C 22 C 4 m 3 m 3 m 4 m 4D040193 16 VRV Systems Indoor Units

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intension to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. VRV products are not within the scope of the Eurovent certification programme. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Printed in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environmont is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende